Plan Review Details - Permit 04021371
Plan Review Stops For Permit 04021371
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-10-06 Cont ID  
Sent By rmcdouga Date 2005-10-06 Time 14:04 Rev Time 0.00
Received By rmcdouga Date 2005-10-06 Time 14:04 Sent To  
Notes
2005-10-06 00:00:00REVISED SHEET A-13.1 IS OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-05-24 Cont ID  
Sent By rmcdouga Date 2005-05-24 Time 13:58 Rev Time 0.00
Received By rmcdouga Date 2005-05-24 Time 13:58 Sent To  
Notes
2005-05-24 00:00:00REVISED ROOF SHINGLES TO CERTAINTEED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-04-13 Cont ID  
Sent By rmcdouga Date 2005-04-13 Time 10:33 Rev Time 0.00
Received By rmcdouga Date 2005-04-13 Time 07:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-04-01 Cont ID  
Sent By jwitmer Date 2004-04-01 Time 15:14 Rev Time 4.00
Received By jwitmer Date 2004-04-01 Time 15:14 Sent To  
Notes
2004-04-01 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04021371
 ADD: 930 MILLBRAE COURT
 CONT: WCI COMMUNITIES
 TEL: (561)775-2120
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 2ND REVIEW8 UNIT/ 3 STORY
  
 ACTION: DENIED
  
 THE COMMENTS FOR THIS REVIEW ARE THE
 SAME AS FOR THE 6 UNIT/ 3 STORY UNIT
 COMMENTS LISTED UNDER 04021360.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-04-13 Cont ID  
Sent By rmcdouga Date 2005-04-13 Time 10:32 Rev Time 0.00
Received By rmcdouga Date 2005-04-13 Time 10:32 Sent To  
Notes
2005-04-13 00:00:00PASSED UNDER MASTER

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-07-14 Cont ID  
Sent By btrobaug Date 2004-07-14 Time 11:59 Rev Time 1.00
Received By btrobaug Date 2004-07-14 Time 10:55 Sent To  
Notes
2004-07-14 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE GEC ON THE RISER DIAGRAM IS 1/0
 IT MUST BE 3/0 PER 250.66.
  
 2} THE RISER DIAGRAM INDICATES A 50 AMP
 RANGE RECER AND THE SCEDULE INDICATES A
 60 AMP FEEDER. PLEASE CORRELATE.
  
 3} THE LOW VOLTAGE SYMBOLS IN THE LEGEND
 DO NOT MATCH THE ONES USED ON THE
 DRAWING.
  
 4} UNIT 1424 NEEDS A RECEPTACLE IN THE
 DINING ROOM ON THE 2ND FLOOR TO COMPLY
 WITH 210.52(A)(1).
  
 5} THERE IS NO DISCONNECT SHOWN FOR THE
 CONDENSING UNIT FOR 1424. PLEASE SHOW
 LOCATION.
  
 6} A CERTIFICATE OF AUTHORIZATION NUMBER
 IS REQUIRED ON THE TITLE BLOCK PER FAC
 61G15-23.002.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-03-29 Cont ID  
Sent By btrobaug Date 2004-03-29 Time 13:30 Rev Time 1.00
Received By btrobaug Date 2004-03-29 Time 10:17 Sent To  
Notes
2004-03-29 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE PROVIDE ELECTRICAL PLANS FOR
 ALL UNIT TYPES, INCLUDING REVERSE
 TYPE'S.
  
 2} PLEASE PUT ROOM LABELS ON ELECTRICAL
 PLANS.(DEN,BEDROOM, ETC.)
  
 3} THE LAUNDRY CALCULATION MUST BE
 1500 VA PER 220.16(B).
  
 4} THE 1VA PER OUTLET CALCULATION IS
 ONLY USED FOR BANKS AND OFFICE
 BUILDINGS, IT IS NOT NECESSARY AND
 CANNOT BE USED FOR DWELLINGS PER
 220.3(B).
  
 5} PLEASE INCLUDE THE HEATING OR AIR
 CONDITIONING LOAD IN THE CALCULATION
 PER 220.30(C).
  
 6} THE PANEL SCHEDULE INDICATES A
 BREAKFAST ROOM. PLEASE SEE 210.52(C)
 FOR WIRE AND OCP SIZE.(#12/20 AMP.)
  
 7} THE RISER DIAGRAM INDICATES A 50 AMP
 OUTLET FOR THE RANGE, THE PANEL SCHEDULE
 INDICATES A 60 AMP BREAKER. PLEASE
 CORRELATE.
  
 8} UNIT 1424 2ND FLOOR NEEDS A
 RECEPTACLE ADDED TO COMPLY WITH
 210.52(A)(1).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2004-04-12 Cont ID  
Sent By mamini Date 2004-04-12 Time 14:54 Rev Time 1.00
Received By mamini Date 2004-04-12 Time 14:54 Sent To  
Notes
2004-04-12 00:00:00PASSED :
 1. SEE # 03101412 FOR UNDERGROUND
 UTILITIES AND SITE WORK.
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2004-03-08 Cont ID  
Sent By mamini Date 2004-03-08 Time 15:50 Rev Time 0.50
Received By mamini Date 2004-03-08 Time 15:49 Sent To  
Notes
2004-03-08 00:00:00FAILED:
 1. PLEASE SUBMIT CIVIL PLANS FOR
 PERMITTING, NOTE THAT CIVIL PLANS WERE
 REVIEWED UNDER # 03101412 (PLAN REVIEW),
 AT YOUR OPTION UNDERGROUND UTILITIES &
 SITE WORK COULD BE UNDER SEPARATE PERMIT
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2005-04-13 Cont ID  
Sent By rmcdouga Date 2005-04-13 Time 10:29 Rev Time 0.00
Received By rmcdouga Date 2005-04-13 Time 10:29 Sent To  
Notes
2005-04-13 00:00:00PASSED UNDER MASTER #05011400

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2004-06-16 Cont ID  
Sent By mcarsill Date 2004-06-16 Time 15:20 Rev Time 0.00
Received By mcarsill Date 2004-06-16 Time 15:20 Sent To  
Notes
2004-06-16 00:00:001) PLEASE INDICATE WHAT FIRE HYDRANTS
 WILL BE AVAILABLE WHEN THE BUILDING
 IS UNDER CONSTRUCTION.
  
 2) YOUR PERMIT RESPONSE FOR WALLS
 AND CEILINGS ARE INCORRECT. CLASS A,
 B, OR C IS THE RESPONSE REQUIRED NOT
 PAINTED FINISH.
  
 3) THE REQUIRED FIRE SPRINKLER SYSTEM
 SHALL BE MONITORED BY A UL LISTED
 COMPANY APPROVED FOR CENTRAL STATION
 SERVICE. "STATION LOCATED AT GATEHOUSE
 DOES NOT MEET THIS REQUIREMENT".
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-04-07 Cont ID  
Sent By mcarsill Date 2004-04-07 Time 13:25 Rev Time 0.00
Received By mcarsill Date 2004-04-07 Time 13:25 Sent To  
Notes
2004-04-07 00:00:00PLANS REVIEW PERFORMED ON 3/4/03
  
 1) ALL SMOKE DETECTORS ARE TO BE
 INSTALLED A MINIMUM OF THREE FEET
 FROM AC DIFFUSERS.
  
 2) PORTABLE FIRE EXTINGUISHERS REQUIRED.
  
 3) THE REQUIRED FIRE SPRINKLER
 SYSTEM SHALL BE MONITORED BY A UL
 LISTED CENTRAL STATION APPROVED FOR
 CENTRAL STATION SERVICE.
  
 4) BUILDING ADDRESSES NOT SHOWN ON
 ELEVATION DRAWINGS. IF THE FRONT DOORS
 DO NOT FRONT A STREET, ADDRESSES WILL
 BE REQUIRED ON BOTH SIDES FOR FIRE
 AND PARAMEDICAL AND POLICE.
  
 5) ALL NEW STAIRS SHALL HAVE HANDRAILS
 ON BOTH SIDES.
  
 6) PLEASE INDICATE INTERIOR FINISH
 FOR WALLS AND CEILINGS.
  
 7) PLEASE EXPLAIN EXITING RATIONALE
 FROM INSIDE THE UNITS.
  
 8) EMERGENCY INSTRUCTIONS FOR
 RESIDENTS SHALL BE PROVIDED.
  
 9) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO, DURING AND AFTER CONSTRUCTION.
  
 10) SUITABLE ROADS ARE TO BE PROVIDED
 DURING CONSTRUCTION.
  
 11) PLEASE INDICATE IF GARAGE DOOR
 IS RATED.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 10 Status   Date 2005-10-05 Cont ID  
Sent By pkrauss Date 2005-10-05 Time 10:05 Rev Time 0.00
Received By pkrauss Date 2005-10-05 Time 10:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2005-09-26 Cont ID  
Sent By adarroug Date 2005-09-26 Time 17:25 Rev Time 0.00
Received By adarroug Date 2005-09-26 Time 17:25 Sent To P
Notes
2005-09-26 00:00:00TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2005-09-21 Cont ID  
Sent By adarroug Date 2005-09-21 Time 19:46 Rev Time 0.00
Received By adarroug Date 2005-09-21 Time 19:46 Sent To B
Notes
2005-09-21 00:00:00TO "RMCDOUGAL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-09-15 Cont ID  
Sent By adarroug Date 2005-09-15 Time 17:20 Rev Time 0.00
Received By adarroug Date 2005-09-15 Time 17:20 Sent To M
Notes
2005-09-15 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-06-07 Cont ID  
Sent By shill Date 2005-06-07 Time 16:08 Rev Time 0.00
Received By shill Date 2005-06-07 Time 16:08 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-05-18 Cont ID  
Sent By adarroug Date 2005-05-18 Time 16:11 Rev Time 0.00
Received By adarroug Date 2005-05-18 Time 16:11 Sent To B
Notes
2005-05-18 00:00:00TO "RMCDOUGAL" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-04-12 Cont ID  
Sent By adarroug Date 2005-04-12 Time 11:08 Rev Time 0.00
Received By adarroug Date 2005-04-12 Time 11:08 Sent To B
Notes
2005-04-12 00:00:00TO "RMCDOUGAL" DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-03-31 Cont ID  
Sent By adarroug Date 2005-03-31 Time 14:42 Rev Time 0.00
Received By adarroug Date 2005-03-31 Time 14:42 Sent To Z
Notes
2005-03-31 00:00:00TO "Z" BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-06-15 Cont ID  
Sent By mjacobs Date 2004-06-15 Time 10:42 Rev Time 0.00
Received By mjacobs Date 2004-06-15 Time 10:42 Sent To  
Notes
2004-06-15 00:00:00TO COMM BD #28

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-07 Cont ID  
Sent By csiegber Date 2004-05-10 Time 10:10 Rev Time 0.00
Received By csiegber Date 2004-03-03 Time 10:35 Sent To  
Notes
2004-03-03 00:00:00TO COMM BD#48/ROLLS ON RACK

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2005-10-05 Cont ID  
Sent By pkrauss Date 2005-10-05 Time 09:35 Rev Time 0.30
Received By pkrauss Date 2005-10-05 Time 09:35 Sent To  
Notes
2005-10-05 00:00:00MECH REVISION

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2005-09-28 Cont ID  
Sent By rregueir Date 2005-09-28 Time 18:51 Rev Time 0.00
Received By rregueir Date 2005-09-28 Time 18:32 Sent To PC
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-07-06 Cont ID  
Sent By pkrauss Date 2004-07-06 Time 07:33 Rev Time 0.45
Received By pkrauss Date 2004-07-06 Time 07:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-03-25 Cont ID  
Sent By pkrauss Date 2004-03-25 Time 14:45 Rev Time 2.25
Received By pkrauss Date 2004-03-25 Time 10:12 Sent To  
Notes
2004-03-25 00:00:00DENIED:
 1.PLEASE NOTE, DETAIL OF UL DESIGN
 L528 IN THE UL DIRECTORY DOES NOT
 INDICATE ANY PENETRATIONS THROUGH THIS
 ASSEMBLY.PLEASE PROVIDE UL LISTING
 FOR THE PENETRATIONS THROUGH THE RATED
 ASSEMBLY.
  
 2.PLEASE CLARIFY RATING ON PLAN SHEET
 A-10 DETAIL #4, THE 1HR RATING IS AT THE
 PARTITION WALL TO THE UNDERSIDE OF THE
 CEILING CORRECT?IF THIS IS CORRECT,
 THE FIRE DAMPER INDICATED ON PLAN SHEET
 M-1 IS NOT REQUIRED BECAUSE THE WALL
 DOES NOT CONTINUE ABOVE THE CEILING.
  
 3.CLARIFY O.A. DUCT, IT APPEARS TO BE
 ABOVE THE CEILING AND DOES NOT PENETRATE
 THE BOTTOM MEMBRANE OF THE ASSEMBLY OR
 AT THE POINT OF ENTRY, FIRE DAMPER IS
 NOT REQUIRED.
  
 4.PER 2001 FBC 705.2.2 EXCEPTION #1,
 A SHAFT ENCLOSURE IS NOT REQUIRED FOR
 OPENING TOTALLY WITHIN A DWELLING UNIT
 & CONNECTING FOUR STORIES OR LESS.
  
 5.PLANS SHALL BE SIGNED BY THE
 ENGINEER NOT STAMPED WITH THEIR
 SIGNATURE PER FS 471.025.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.
  
  
  
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 5 Status P Date 2005-10-07 Cont ID  
Sent By jleech Date 2005-10-07 Time 13:50 Rev Time 0.00
Received By jleech Date 2005-10-07 Time 13:49 Sent To  
Notes
2005-10-07 00:00:00REVISED PLUMBING PAGES P-1 & P-2 OK PAGE
 P-3 NOT CLOUDED

Review Stop P PLUMBING
Rev No 4 Status P Date 2005-06-25 Cont ID  
Sent By jleech Date 2005-06-25 Time 10:17 Rev Time 0.33
Received By jleech Date 2005-06-25 Time 10:17 Sent To  
Notes
2005-06-25 00:00:00REVISION ADDED WATER METERS TO EACH UNIT

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-04-13 Cont ID  
Sent By rmcdouga Date 2005-04-13 Time 10:29 Rev Time 0.00
Received By rmcdouga Date 2005-04-13 Time 10:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-06-21 Cont ID  
Sent By kstevens Date 2004-06-21 Time 17:49 Rev Time 1.00
Received By kstevens Date 2004-06-21 Time 17:49 Sent To  
Notes
2004-06-21 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) SHT P-1 WATER RISER DIAGRAM UNCLEAR
 AND HARD TO READ. SOME INFORMATION IS
 NOT READABLE. SECTION 104.2.1
 2) SHT P-1 WHITE OUT IS USED ON SOME
 PLUMBING NOTES. THIS IS NOT APPROVED.
 NOTES SHALL BE DELETED.
 3) SHT P-2 WATER RISER DIAGRAM IS UN-
 CLEAR AND HARD TO READ. RISER DOES NOT
 REFLECT THE FLOOR PLAN. FIRST FLOOR BATH
 ROOM IS NOT SHOWN ON RISER DIAGRAM.
 SECTION 104.2.1
 4) CERTIFICATE OF AUTHORIZATION IS NOT
 IN TITLE BLOCK AS REQUIRED. SEE BELOW
 ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS 471.025
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-03-15 Cont ID  
Sent By kstevens Date 2004-03-15 Time 14:39 Rev Time 1.00
Received By kstevens Date 2004-03-15 Time 14:39 Sent To  
Notes
2004-03-15 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) A WATER RISER DIAGRAM IS REQUIRED FOR
 ALL UNIT TYPES. SECTION 104.3.1.1.
 2) SHTS P-1 & P-2 SIGNATURE REQUIRED ON
 SEAL, SIGNATURE STAMP NOT ACCEPTABLE.
 CERTIFICATION OF AUTHORIZATION REQUIRED.
 A PROFESSIONAL ENGINEER SHALL SIGN HIS
 NAME AND AFFIX HIS SEAL TO ALL PLANS,
 SPECIFICATIONS, REPORTS AND FINAL BID
 DOCUMENTS PROVIDED TO THE OWNER OR THE
 OWNER'S REPRESENTATIVE, OR OTHER DOCU-
 MENTS PREPARED OR ISSUED BY SAID REGIS-
 TRANT AND BEING FILED FOR PUBLIC RECORD.
 THE DATE THAT THE SIGNATURE AND SEAL IS
 AFFIXED AS PROVIDED HEREIN SHALL BE EN-
 TERED ON SAID PLANS, SPECIFICATIONS, RE-
 PORTS, OR OTHER DOCUMENTS IMMEDIATELY
 UNDER THE SIGNATURE OF THE PROFESSIONAL
 ENGINEER, FAC 61G15-23.002(1)
 FS 471.025
 EACH SHEET OF PLANS AND PRINTS WHICH
 MUST BE SEALED UNDER THE PROVISIONS OF
 CHAPTER 471 SHALL BE SEALED, SIGNED AND
 DATED BY THE PROFESSIONAL ENGINEER IN
 RESPONSIBLE CHARGE. FAC 61G15-23.002(2)
 FS 471.025
 ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS 471.025
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2005-04-07 Cont ID  
Sent By eschneid Date 2005-04-07 Time 13:20 Rev Time 0.00
Received By eschneid Date 2005-04-07 Time 13:20 Sent To  
Notes
2005-04-07 00:00:00PASSED BASED ON THE APRIL 6, 2005
 REVISION TO THE B ELEVATION MASTER
 (PERMIT NO. 05011400).

Review Stop Z ZONING
Rev No 1 Status F Date 2004-03-22 Cont ID  
Sent By sgraham Date 2004-03-22 Time 09:15 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
2004-03-22 00:00:001. NO SITE & LANDSCAPE PLANS INCLUDED.
 2. MUST SHOW BUILDING HEIGHT MEETS CODE
 REQUIREMENTS ON ELEVATION SHEETS
 A-7,A-8
 3. FALSE CHIMNEY EXCEEDS HEIGHT
 EXCEPTION