| Plan Review Stops For Permit 04021360 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2005-10-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-10-06 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-10-06 |
Time |
07:22 |
Sent To |
|
|
| Notes |
| 2005-10-06 00:00:00 | REVISED SHEET A-13.1 IS OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-05-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-05-24 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-05-24 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2005-05-24 00:00:00 | REVISED ROOF SHINGLES TO CERTAINTEED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-03-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-24 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-24 |
Time |
09:18 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-03-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-18 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-18 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2005-03-18 00:00:00 | DENIED | | | | | | 1) THE SURVEY INCORRECTLY SPECIFIES THE | | | STRUCTURE AS TWO STORY. | | | | | | 2) THE ENERGY CALC. FORM IS NOT SIGNED | | | BY THE OWNER/AGENT. | | | | | | 3) THERE IS AN ADDITIONAL ENERGY CALC. | | | FORM LISTING A 4TON UNIT FOR THE 2215 | | | SQFT MID UNIT THAT WAS NOT SUBMITTED | | | WITH THE MASTER. | | | | | | 4) SHEETS A6, A7 AND A8 HAVE BEEN | | | REVISED AND DO NOT MATCH THE MASTER | | | PLAN. THE STEP IN THE ROOF HAS BEEN | | | CHANGED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-07-29 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-07-29 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2004-07-29 00:00:00 | NOTE: BEFORE THE CERTIFICATE OF | | | OCCUPANCY IS ISSUED THE RECORDED | | | DECLARATION OF CONDOMINIUM WILL BE | | | REQUIRED. | | | | | | 1) ENERGY CALCS. ARE REQUIRED FOR EACH | | | UNIT TYPE AND LOCATION (EXTERIOR AND | | | INTERIOR). THE CONDITIONED SPACE ON THE | | | FORMS DIFFERS FROM THE ONES LISTED ON | | | THE PLANS. PLEASE CORRECT. | | | | | | 2) MASTERED PLANS ARE NOT ALLOWED TO BE | | | REDLINED. SEE SHEETS A10, S7 AND S5. | | | PLEASE CORRECT SEPIAS. | | | | | | 3) DETAIL 4 ON S1 IS INCORRECT. IT | | | SHOULD BE A SECTION OF THE EXTERIOR WALL | | | AND FOOTING. | | | | | | 4) THE FOUNDATION NOTES #3,4,& 5 ON S1 | | | REFER TO SHEETS S3 AND S4 FOR DETAILS. | | | HOWEVER, THERE ARE NO FOUNDATION NOTES | | | ON S3 OR S4. PLEASE CORRECT. | | | | | | 5) ON SHEET A12, DETAIL #2 IS MISSING | | | THE FIRESTOP BETWEEN THE VERTICAL AND | | | HORIZONTAL AREAS. WALL SHEATHING SHOULD | | | EXTEND TO BOTTOM OF FLOOR TRUSSES. | | | PLEASE CORRECT. | | | | | | 6) FIRESTOP IS ALSO MISSING AT CONCEALED | | | SPACES WHERE HORIZONTAL AND VERTICAL | | | SPACES INTERSECT AT SECTIONS 11 AND 13 | | | ON S7. SEE FBC 2305.1.4. | | | | | | 7) SHEET S2 HAS AN ID MARK FOR A DETAIL | | | #17 ON S7. THERE IS NO SUCH DETAIL. | | | PLEASE CORRECT. | | | | | | 8) THE PRODUCT APPROVAL SUBMITTED FOR | | | THE FRONT DOOR INDICATES THAT THE DOOR | | | IS NOT RATED FOR IMPACT AND IS REQUIRED | | | TO BE SHUTTERED. PLANS SPECIFY THIS DOOR | | | IS REQUIRED FOR EGRESS AND IS NOT TO BE | | | SHUTTERED. PLEASE CORRECT. | | | | | | 9) REVISE THE UPLIFT VALUE LISTED IN THE | | | SCHEDULE ON S4 FOR THE SIMPSON HETAL 20. | | | THE MAXIMUM UPLIFT VALUE IS 1810# IN THE | | | 2004 SIMPSON CATALOG, WHICH DOES NOT | | | INCLUDE A ONE-THIRD INCREASE IN THE | | | STEEL CALCULATIONS. | | | | | | 10) REVIEW THE TRUSS DRAWINGS AND REVISE | | | THE CONNECTORS SPECIFIED FOR TRUSSES | | | THAT EXCEED THE UPLIFT VALUES GIVEN IN | | | SCHEDULE FOR THE SPECIFIED CONNECTOR. | | | MARK (F) AN H10 IS NOT ADEQUATE FOR | | | TRUSSES T4B, T4, T3, T2, T1, H2, AND H1. | | | MARK (H) AN H3 AND MARK (A) A HETAL 12 | | | ARE ALSO INADEQUATE FOR SOME OF THE | | | TRUSS UPLIFTS FOR WHICH THEY ARE | | | SPECIFIED. PLEASE CORRECT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-03-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-03-31 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-07-29 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2004-03-31 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04021360 | | | ADD: 960 MILLBRAE COURT | | | CONT:WCI | | | TEL: (561)775-2120 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | | | | | ACTION: DENIED | | | | | | NOTE: A SIGNED & SEALED LETTER FROM THE | | | ARCHITECT OF RECORD INDICATING THE PLANS | | | SUBMITTED ARE OCCUPANCY TYPE: (R2). | | | WITH THE VARIOUS PLANS AND GEO REPORTS | | | STATING TOWNHOMES AS PART OF THE NAME, | | | IT IS TO BE MADE CLEAR THAT THE REVIEWS | | | AND PERMITS WILL BE ISSUED "R2" FOR | | | CONDOMINIUM. BEFORE THE CERTIFICATE OF | | | OCCUPANCY IS ISSUED THE RECORDED | | | DECLARATION OF CONDOMINIUM WILL BE | | | REQUIRED. | | | | | | 1) 105.3 CITY ADMINISTRATIVE CODE, | | | RESIDENT INSPECTOR TO BE REQUIRED. | | | CONTACT HAROLD PISKURA @ 805-6711, FOR | | | MORE INFORMATION AS TO COMPLETED UNITS | | | VS CONSTRUCTION AREAS, REQUIRED STRUC- | | | TURAL INSPECTORS AND PHASING. | | | | | | 2) SITE PLAN INDICATING ALL SITE AMENIT- | | | ITIES WITH DIMENSIONS BETWEEN BUILDINGS | | | INDICATING THE ASSUMED PROPERTY LINE | | | BETWEEN BUILDINGS, TO CALCULATE ALLOW- | | | ABLE OPENING SIZES, VERIFY WITH TABLE | | | 600. | | | | | | 3) SOILS REPORT: | | | PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 4)FBC 13-103.1.2 BEFORE A BUILDING | | | PERMIT CAN BE ISSUED, THE SUBMITTED | | | ENERGY CODE COMPLIANCE FORMS SHALL BE | | | SIGNED BY THE BUILDING OWNER, THE | | | OWNER'S ARCHETECT OR OTHER AUTHORIZED | | | AGENT LEGALLY DESIGNATED BY THE OWNER. | | | | | | 5) WHEN THE ENERGY FORMS ARE FILLED OUT | | | BY THE ENGINEER OF RECORD THIS IS FOR | | | PUBLIC RECORD, MUST BE SIGNED& SEALED. | | | | | | 6) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 7)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 8) FAIR HOUSING FOR THE COMMON AREAS, | | | PROVIDE A SITE PLAN INDICATING THE | | | ACCESSIBLE ROUTE TO ALL ELEMENTS, INCLUD | | | ING THE CLUBHOUSE, GAZEBOES,DUMPSTERS, | | | POOLS, PARKING AND THE PATH OF TRAVEL | | | TO PUBLIC TRANSPORTATION. | | | | | | 9) SEE S-5 | | | CORRECT DOOR AND WINDOW PRESSURE SCHED- | | | ULE, WALL AREAS INTERIOR ZONES SHOULD BE | | | REPRESENTED BY ZONE (4) NOT ZONE(1),AND | | | THE END ZONES SHOULD BE REPRESENTED BY | | | ZONE(5) NOT (2). | | | B) ROOF NAILING ZONES,ZONE (3) NOTE DIF | | | FICULT TO UNDERSTAND, IT CAN BE PRECEVED | | | THAT THE ZONE (3) MAY BE NAILED THE | | | SAME AS ZONE# 2. | | | C) ROOF NAILING CHART IS ONLY GOOD TO | | | 35' ABOVE GRADE. THE TRUE HEIGHT OF THE | | | BUILDING IS > 35', THE ENGINEER OF | | | RECORD SHALL PROVIDE THE ADDITIONAL | | | INFORMATION REQUIRED FOR THE NAILING | | | REQUIREMENTS FOR THE EFFECTED NAILING | | | ZONES. | | | | | | 10) AMARR GARAGE DOORS DO NOT MEET THE | | | NEGITIVE PRESSURES FOR A BUILDING >35' | | | TALL WITH THE ADJUSTMENT COEFFICIENT | | | OF 1.09 SEE 1606.2D & 1606.2E. | | | | | | 11) SHEET A-12 DETAIL# 2, IS MISSING THE | | | FIRE STOP BETWEEN THE VERTICAL & HORIZON | | | TAL AREAS 2ND & 3RD FLOOR WALL SHEATHING | | | CUT SHORT, ALSO MISSING FOR THE WALL | | | DIAPHRAM. | | | | | | 12)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | 2ND REQUEST: | | | FOR THE PRODUCT TESTING REPORTS FOR THE | | | STRUCTURAL COMPONENTS- TRUSS ANCHORS, | | | CONCRETE TO WOOD, WOOD TO WOOD. | | | | | | 13) SHEET M-1, M-2 : | | | 1503.4.4 PROTECTION AGAINST DECAY & | | | TERMITES. CONDENSATE LINES & ROOF DOWN | | | SPOUTS SHALL DISCHARGE AT LEAST 1 FT. | | | AWAY FROM THE STRUCTURE SIDEWALL, | | | WHETHER BY UNDERGROUND PIPING, TAIL EX- | | | TENSIONS, OR SPLASH BLOCKS. | | | | | | 14) 2ND REQUEST, PROVIDE TRUSS ENGINEER- | | | ING SHEETS WITH ALL LOADING CASES, VER- | | | TICAL, HORIZONTAL AND GRAVITY LOADS. THE | | | PLANS DO NOT INDICATE THE LOADING, ONLY | | | THE ALLOWABLE VALUES FOR ANCHORS. | | | | | | 15) GARAGE TO LIVING QUARTERS, THE | | | GARAGE DOOR IS NOT LISTED ON THE DOOR | | | SCHEDULE. A 3/4HR RATED DOOR IS REQUIRED | | | 4.1.2.6/ 705.1.3.5, THS DOOR SHALL ALSO | | | BE EQUIPED WITH AN APPROVED CLOSER. | | | | | | 16) SHEET S-2 MASONARY WALLS, ARE DESIGN | | | EDAS MW-1, S-5 MASONARY WALL SCHEDULE IS | | | #5@48" O.C., NO MENTION ABOUT REINFORC- | | | ING AT WINDOWS NOR CORNERS. | | | | | | 17) GARAGE BEAMS AT OVERHEAD DOORS, NO | | | INFORMATION IN THEBEAM SCHEDULE NOR IS A | | | LENTAL SCHEDULE PROVIDED WITH THE SAFE | | | ALLOWABLE LOADS. | | | | | | 18) S-3 VS S-7 DETAIL# 8 INDICATES THIS | | | IS TO BE A 2X6 WALL NO DETAILS FOR FAST- | | | ENING THE WALL TO THE STRUCTURE BELOW. | | | VERSES THE SHEET S-3 INDICATING A BLOCK | | | WALL NO BEAM INFORMATION ? | | | | | | 19) S-7 DETAIL 11: | | | A) THIS DETAIL IS MISSING STRAPING FOR | | | THE WALL TO FLOOR TRUSSES. | | | B) MISSING LEDGER ON THE LOWER WALL | | | FOR NAILING OF THE DRYWALL CEILING. | | | C) MISSING FIRESTOP LOWER WALL WHERE | | | THE MISSING LEDGER IS LOCATED. | | | | | | 20) S-7 DETAIL 13: | | | A) MISSING FIRESTOP VERTICAL TO HORIZON- | | | TAL LOCATIONS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-03-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-24 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-24 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2005-03-24 00:00:00 | PASSED UNDER MASTER # 04071171 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-07-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-07-08 |
Time |
14:03 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-07-06 |
Time |
07:03 |
Sent To |
|
|
| Notes |
| 2004-07-08 00:00:00 | | | | PLEASE INCLUDE THE ENGINEERING FIRMS | | | AUTHORIZATION NUMBER ON THE TITLE BLOCK | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | PER 61G15-23.002 FAC. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-04-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-04-01 |
Time |
18:14 |
Rev Time |
2.00 |
| Received By |
btrobaug |
Date |
2004-04-01 |
Time |
17:08 |
Sent To |
|
|
| Notes |
| 2004-04-01 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} INDICATE THE EQUIPMENT GND CONDUCTOR | | | SIZE ON THE RISER DIAGRAM PER 250.122. | | | | | | 2} THE DRAWING SHOWS A MAIN DISCONNECT | | | AND 8 "METERS AND DISCONNECTS". THE | | | RISER INDICATES A 6GANG METER CENTER | | | WITH NO MAIN. PLEASE CORRELATE. | | | | | | 3} THE LAUNDRY CIRCUIT CALCULATION MUST | | | COMPLY WITH 220.16.(1500 VA). | | | | | | 4} PLEASE LABEL ROOMS ON THE ELECTRIC | | | PLANS TO CORRESPOND WITH THE | | | ARCHITECTURAL PLANS. | | | | | | 5} PLEASE PROVIDE PLANS FOR ALL UNITS, | | | INCLUDING REVERSED MODELS. | | | | | | 6} NOTE THAT THE "NOOK" 7 DINING ROOM | | | MUST COMPLY WITH 210.52(B). | | | | | | 7} THE DINING ROOMIN UNIT "2203" MUST | | | HAVE 2 RECEPTACLES ADDED TO COMPLY WITH | | | 210.52(A). | | | | | | 8} THE PANEL SCHEDULE REFERS TO | | | "LIVING/BREAKFAST" ROOM, THE BREAKFAST | | | ROOM | | | MUST BE ON A 20 AMP CIRCUIT TO COMPLY | | | WITH 210.52(B), HOWEVER THERE IS NO | | | ROOM LABLED LIKE THAT ON THE | | | ARCHITECTURAL PLANS. | | | | | | 9} SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | | UNIT. | | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | | TO FLOORS ABOVE AND IN THE VICINITY OF | | | BEDROOMS. | | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | | A MIN OF 3' FROM BATHROOM DOORS AND | | | KITCHENS. | | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4 | | | | | | 10} NOTE THAT THE SIGNATURE OF THE EN- | | | GINEER IS REQUIRED ON HIS/HER SEAL PER | | | 61G15-23.002 FLORIDA ADMINISTRATIVE | | | CODESTAMPED SIGNATURES ARE NOT | | | ACCEPTABLE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2004-04-12 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-04-12 |
Time |
14:57 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-04-12 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2004-04-12 00:00:00 | PASSED : | | | 1. SEE # 03101412 FOR UNDERGROUND | | | UTILITIES AND SITE WORK. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2004-03-08 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-03-08 |
Time |
15:43 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2004-03-08 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2004-03-08 00:00:00 | FAILED: | | | 1. PLEASE SUBMIT CIVIL PLANS FOR | | | PERMITTING, NOTE THAT CIVIL PLANS WERE | | | REVIEWED UNDER #03101412 (PLAN REVIEW), | | | AT YOUR OPTION UNDERGROUND UTILITIES & | | | SITE WORK COULD BE UNDER SEPARATE PERMIT | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2005-03-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-24 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-24 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2005-03-24 00:00:00 | PASSED UNDER MASTER # 04071171 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2004-06-16 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-06-16 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-06-16 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2004-06-16 00:00:00 | 870 MARINA DEL RAY | | | 883 MILLBRAE COURT | | | 840 MARINA DEL RAY | | | 845 MILLBRAE COURT | | | | | | 1) PLEASE INDICATE WHAT FIRE HYDRANTS | | | WILL BE AVAILABLE WHEN THE BUILDINGS | | | ARE UNDER CONSTRUCTION. | | | | | | 2) YOUR PERMIT RESPONSE FOR WALLS AND | | | CEILINGS ARE INCORRECT. CLASS A, B, | | | OR C NOT PAINTED RESPONSE IS REQUIRED. | | | | | | 3) THE REQUIRED FIRE SPRINKLER | | | SYSTEM SHALL BE MONITORED BY A UL | | | LISTED CENTRAL STATION APPROVED FOR | | | CENTRAL STATION SERVICE. "STATION | | | LOCATED AT GATEHOUSE DOES NOT MEET | | | THIS REQUIREMENT. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-04-07 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-04-07 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-04-07 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2004-04-07 00:00:00 | SEE PREVIOUS PLAN REVIEW COMMENTS | | | FOR OTHER BUILDINGS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-10-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-10-05 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-10-05 |
Time |
10:29 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-09-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-26 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-26 |
Time |
17:40 |
Sent To |
P |
|
| Notes |
| 2005-09-26 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
F |
Date |
2005-09-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-21 |
Time |
19:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-21 |
Time |
19:40 |
Sent To |
B |
|
| Notes |
| 2005-09-21 00:00:00 | TO "RMCDOUGAL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-09-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-15 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-15 |
Time |
17:09 |
Sent To |
M |
|
| Notes |
| 2005-09-15 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-05-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-27 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-27 |
Time |
14:42 |
Sent To |
P |
|
| Notes |
| 2005-05-27 00:00:00 | TO "KSTEVENS" BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-18 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-18 |
Time |
16:13 |
Sent To |
B |
|
| Notes |
| 2005-05-18 00:00:00 | TO "RMCDOUGAL" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-22 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-22 |
Time |
12:01 |
Sent To |
B |
|
| Notes |
| 2005-03-22 00:00:00 | TO "RMCDOUGAL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-03-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-15 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-15 |
Time |
10:01 |
Sent To |
Z |
|
| Notes |
| 2005-03-15 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-06-15 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-06-15 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2004-06-15 00:00:00 | TO COMM BD #28 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-04-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-10 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-03 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2004-03-03 00:00:00 | TO COMM BD#48/ROLLS ON RACK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2005-10-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-10-05 |
Time |
10:30 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2005-10-05 |
Time |
10:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-09-28 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2005-09-28 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2005-09-28 |
Time |
16:04 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-07-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-07-02 |
Time |
11:38 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-07-02 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2004-07-02 00:00:00 | MASTER FOR ROWHOUSE 6 UNITS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-03-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-26 |
Time |
06:56 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2004-03-25 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2004-03-26 00:00:00 | DENIED: | | | 1.PLEASE NOTE, DETAIL OF UL DESIGN | | | L528, IN THE UL DIRECTORY DOES NOT | | | INDICATE ANY PENETRATIONS THROUGH THIS | | | ASSEMBLY.PLEASE PROVIDE UL LISITING | | | FOR THE PENETRATIONS THROUGH THE RATED | | | ASSEMBLY. | | | | | | 2.PLEASE CLARIFY RATING ON PLAN SHEET | | | A-10 DETAIL #4, THE 1HR RATING IS AT THE | | | PARTITION WALL TO THE UNDERSIDE OF THE | | | CEILING CORRECT?IF THIS IS CORRECT, | | | THE FIRE DAMPER INDICATED ON PLAN SHEET | | | M-1 IS NOT REQUIRED BECAUSE THE WALL | | | DOES NOT CONTINUE ABOVE THE CEILING. | | | | | | 3.CLARIFY O.A. DUCT, IT APPEARS TO BE | | | ABOVE THE CEILING AND DOES NOT PENETRATE | | | AT THE POINT OF ENTRY, FIRE DAMPER IS | | | NOT REQUIRED. | | | | | | 4.PER 2001 FBC 705.2.2 EXCEPTION #1, | | | A SHAFT ENCLOSURE IS NOT REQUIRED FOR | | | OPENINGS TOTALLY WITHIN A DWELLING UNIT | | | & CONNECTING FOUR STORIES OR LESS. | | | | | | 5.PLANS SHALL BE SIGNED BY THE | | | ENGINEER NOT STAMPED WITH THEIR | | | SIGNATURE PER FS 471.025. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2005-10-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-10-07 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2005-10-07 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2005-10-07 00:00:00 | REVISED PLUMBING PAGES P-1 & P-2 ONLY | | | PAGE P-3 NOT CLOUDED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-06-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-06-14 |
Time |
13:27 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-06-14 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2005-06-14 00:00:00 | ADDED WATER METER IN EACH UNIT |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-03-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-24 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-24 |
Time |
09:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-07-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-20 |
Time |
07:05 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-07-20 |
Time |
07:04 |
Sent To |
|
|
| Notes |
| 2004-07-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | A) COMMENTS FROM PREVIOUS REVIEWS HAVE | | | NOT BEEN ADDRESSED PROPERLY. COMMENT | | | NUMBER TO STAY THE SAME TO AVOID CONFUS- | | | ION. | | | 8)ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | | SHEET. IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | | EERS SHALL LEGIBLY INDICATE THEIR NAME | | | AND LICENSE NUMBER, AS WELL AS, THE NAME | | | ADDRESS AND CERTIFICATE OF AUTHORIZATION | | | NUMBER OF THE ENGINEERING BUSINESS ON | | | EACH SHEET. A TITLE BLOCK WILL SATISFY | | | THIS REQUIREMENT. FAC 61G15-23.002(2) | | | AND FS 471.025. | | | ***************NEW COMMENTS************* | | | 1C) SHT P-1 PLUMBING GENERAL NOTES #19 | | | HAS BEEN DELETED WITH WHITE-OUT. THIS IS | | | NOT APPROVED. PLEASE DELETE NOTE ON PLAN | | | PROPERLY. SECTION 104.2.1.3 | | | 2C) SHT P-1 PLUMBING GENERAL NOTES #16 | | | WHITE OUT USED ON NOTE TO DELETE INFOR- | | | MATION. THIS IS NOT APPROVED. 104.2.3 | | | 3) WATER RISER DIAGRAMS ARE UNCLEAR AND | | | HARD TO READ. THE WATER RISER DIAGRAM ON | | | SHT P-2 DOES NOT REFLECT THE FLOOR PLAN. | | | THE BATHROOM ON THE FIRST FLOOR AND THE | | | BATHROOM ON THE SECOND FLOOR SHOWN ON | | | THE FLOOR PLAN ARE NOT SHOWN ON THE | | | WATER RISER DIAGRAM. | | | 4)ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | | SHEET. IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | | EERS, ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME AND LICENSE NUMBER, AS WELL | | | AS, THE NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. A TITLE BLOCK | | | WILL SATISFY THIS REQUIREMENT. FAC | | | 61G15-23.002(2) - FS 471.025 | | | 5C) SEE ATTACHED SHEET IN REFERENCE TO | | | FS 553.80(2)(B). FOUR TIMES THE FEE FOR | | | THE PLAN REVIEW PORTION OF THE PERMIT | | | SHALL BE IMPOSED IF THE SAME COMMENTS | | | ARE NOT ADDRESSED PER FLA. STATUTE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-03-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-15 |
Time |
15:31 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-03-15 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2004-03-15 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) A WATER RISER DIAGRAM IS REQUIRED FOR | | | ALL UNIT TYPES. SECTION 104.3.1.1 | | | 2) SHTS P-1 & P-2 SIGNATURE REQUIRED ON | | | SEAL, SIGNATURE STAMP NOT ACCEPTABLE. | | | A PROFESSIONAL ENGINEER SHALL SIGN HIS | | | NAME AND AFFIX HIS SEAL TO ALL PLANS, | | | SPECIFICATIONS, REPORTS AND FINAL BID | | | DOCUMENTS PROVIDED TO THE OWNER OR THE | | | OWNER'S REPRESENTATIVE, OR OTHER DOCU- | | | MENTS PREPARED OR ISSUED BY SAID REGIS- | | | TRANT AND BEING FILED FOR PUBLIC RECORD. | | | THE DATE THAT THE SIGNATURE AND SEAL IS | | | AFFIXED AS PROVIDED HEREIN SHALL BE EN- | | | TERED ON SAID PLANS, SPECIFICATIONS, RE- | | | PORTS, OR OTHER DOCUMENTS IMMEDIATELY | | | UNDER THE SIGNATURE OF THE PROFESSIONAL | | | ENGINEER, FAC 61G15-23.002(1) | | | FS 471.025 | | | EACH SHEET OF PLANS AND PRINTS WHICH | | | MUST BE SEALED UNDER THE PROVISIONS OF | | | CHAPTER 471 SHALL BE SEALED, SIGNED AND | | | DATED BY THE PROFESSIONAL ENGINEER IN | | | RESPONSIBLE CHARGE. FAC 61G15-23.002(2) | | | FS 471.025 | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | | SHEET. IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | | EERS, ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME AND LICENSE NUMBER, AS WELL | | | AS, THE NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. A TITLE BLOCK | | | WILL SATISFY THIS REQUIREMENT. FAC | | | 61G15-23.002(2) - FS 471.025 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2005-03-24 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2005-03-24 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2005-03-24 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2005-03-17 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2005-03-17 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2005-03-17 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2005-03-17 00:00:00 | 1) THE SURVEY DOES NOT MATCH THE | | | SUBMITTED PLANS. SURVEY CALLS OUT A 2 | | | STORY BUILDING, WHILE PLANS ARE FOR A 3 | | | STORY BUILDING. | | | 2) SETBACK DISTANCE FROM THE BUILDING TO | | | THE EAST PROPERTY LINE SHALL BE SHOWN. | | | ERIC SCHNEIDER (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2004-03-22 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |