| 2004-03-23 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 04021355 |
| | ADD: 1770MISSION COURT |
| | CONT: WCI COMMUNITIES |
| | TEL: (561)775-2120 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | 1ST PERMIT REVIEW |
| | PLAN REVIEW: 04010005 |
| | |
| | ACTION: DENIED |
| | |
| | NOTE: A SIGNED & SEALED LETTER FROM THE |
| | ARCHITECT OF RECORD INDICATING THE PLANS |
| | SUBMITTED ARE OCCUPANCY TYPE: (R2). |
| | WITH THE PLANS STATING "TOWNHOUSE" AS |
| | PART OF THE NAME IT IS TO BE MADE CLEAR |
| | THAT ALL DOCUMENTS INCLUDING THE SOILS |
| | REPORTS SHOULD NOT STATE TOWNHOMES. |
| | FOR THESE UNITS TO BE SOLD AS CONDOMIN |
| | IUMS A RECORDED DECLARATION OF CONDOMIN- |
| | IUM SHALL BE REQUIRED BEFORE A CERTIFI- |
| | CATE OF OCCUPANCY WILL BE ISSUED. |
| | |
| | 1) 105.3 CITY ADMINISTRATIVE CODE, |
| | RESIDENT INSPECTOR TO BE REQUIRED. |
| | CONTACT HAROLD PISKURA)@ 805-6711 FOR |
| | MORE INFORMATION AS TO THE REQUIREMENTS |
| | OF COMPLETED UNITS VS CONSTRUCTION AREAS |
| | REQUIRED STRUCTURAL INSPECTIONS AND |
| | PHASING. |
| | |
| | 2)FL BLD CODE 104.2.1.2 |
| | ADDITIONAL INFORMATION REQUIRED, |
| | 2ND REQUEST!!!!!!!!!!!!!!!!! |
| | A SITE PLAN INDICATING ALL SITE AMENIT- |
| | IES WITH DIMENSIONS BETWEEN BUILDINGS |
| | INDICATING THE ASSUMED PROPERTY LINE |
| | BETWEEN BUILDINGS, TO CALCULATE ALLOW- |
| | ABLE OPENING SIZES TABLE 600. UNABLE TO |
| | VARIFY COMPLIANCE WITH TABLE 600. |
| | " 2ND REQUEST". HIGHLIGHT WHICH BUILDING |
| | IS PERMITTED UNDER THIS PERMIT! |
| | |
| | 3) FL BLD CODE 1804.2.2 QUESTIONABLE |
| | SOILS, WHERE THE BEARING CAPACITY IS |
| | NOT DEFINETLY KNOWN OR IS IN QUESTION. |
| | WHERE THE BEARING CAPACITY OF THE SOIL I |
| | S NOT DEFINITEY KNOWN, OR IS IN QUESTION |
| | THE BUILDING OFFICIAL MAY REQUIRE EXPLOR |
| | ATIONS, TEST OR OTHER ADEQUATE PROOF AS |
| | TO THE PERMISSIBLE SAFE BEARING |
| | CAPACITY. REQUIRED TEST AND RECOMMENDA- |
| | TIONS SUBMITTED TO VERIFY BEARING CAPA- |
| | CITY SHALL BE CERTIFIED BY A GEOTECH- |
| | NICALREPORT FROM A DESIGN PROFESSIONAL P |
| | ROPERLY LICENSED IN THE STATE OF |
| | FLORIDA. |
| | PLANS, SPECIFICATIONS,REPORTS OR |
| | OTHER DOCUMENTS PREPARED BY THE DESIGN |
| | PROFESSIONAL AND BEING FILED FOR PUBLIC |
| | RECORD SHALL HAVE THE SIGNATURE AND |
| | SEAL OF THE DESIGN PROFESSIONAL AFFIXED |
| | TO THE DOCUMENT. |
| | FL STATE STAT: 61G15-23.002 ENGINEERS |
| | FL ATATE STAT: 61G16.003 ARCHITECTS |
| | 2ND REQUEST, THE SOILS REPORT |
| | PROVIDED IS NOT THE ORIGINAL RAISED SEAL |
| | WITH ORIGINAL SIGNATURE. |
| | |
| | 4)FBC 13-103.1.2 BEFORE A BUILDING |
| | PERMIT CAN BE ISSUED, THE SUBMITTED |
| | ENERGY CODE COMPLIANCE FORMS SHALL BE |
| | SIGNED BY THE BUILDING OWNER, THE |
| | OWNER'S ARCHETECT OR OTHER AUTHORIZED |
| | AGENT LEGALLY DESIGNATED BY THE OWNER. |
| | |
| | 5) PROVIDE NOC RECORDED WITH THE CLERK |
| | OF COURT BEFORE A PERMIT CAN BE ISSUED. |
| | 2ND REQUEST!!!!!!!! |
| | |
| | 6)BEFORE A PERMIT TO CONSTRUCT, MAY |
| | BE ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 7) FAIR HOUSING, 1. ACCESSIBLE ROUTE, |
| | INDICATE ON THE SITE PLAN, THE ACCESS- |
| | IBLE ROUTE TO ALL ELEMENTS, INCLUDING |
| | THE CLUBHOUSE,GAZEBOES,DUMPSTER, POOLS, |
| | PARKING AND PATH OF TRAVEL TO PUBLIC |
| | TRANSPORTATION. |
| | |
| | 8) SHEET A-11 TYP 2 STORY DETAIL AT THE |
| | GARAGE MISSING FLOOR INSULATION OVER THE |
| | GARAGE. SEPERATION OF A/C VS NON. |
| | 2ND REQUEST!!!!!!!! |
| | |
| | 9) SHEET A-11 SECTION 3 & 4 INDICATE THE |
| | USE OF WIRE LATH ON THE SOFFIT, ADD INFO |
| | REQUIRED FOR INSTALLATION. I PROVIDED |
| | THE CODE ARTICLE FOR THE FASTENING TO |
| | HORIZONTAL FRAMING MEMBERS( 2504.2.2) |
| | FOR A REFRENCE ONLY PLEASE INDICATE |
| | FASTENING ON PLAN. |
| | 104.2.1 W.P.B. ADMINISTRATIVE CODE |
| | DRAWINGS & SPECIFICATIONS SHALL CONTAIN |
| | INFORMATION, IN THE FORM OF NOTES OR |
| | OTHERWISE, AS TO THE QUALITY OF |
| | MATERIALS, WHERE QUALITY IS ESSENTIAL TO |
| | CONFORMITY WITH THE TECHNICAL CODES. |
| | SUCH INFORMATION SHALL BE SPECIFIC |
| | AND THE TECHNICAL CODES "SHALL NOT BE |
| | CITED AS A WHOLE OR IN PART, NOR THE |
| | TERM "LEGAL" OR ITS RQUIVALENT BE USED |
| | AS A SUBSTITUTE FOR SPECIFIC |
| | INFORMATION". |
| | |
| | 10) FLORIDA STATEWIDE PRODUCT APPROVALS: |
| | A COVERSHEET FOR EACH PRODUCT APPROVAL |
| | SUBMITTED WAS PULLED FROM THE WEBSITE, |
| | COPY AND PROVIDE WITH EVERY PRODUCT |
| | APRROVAL SUBMITTED!!!!!!!!!!!!!!!!!!! |
| | |
| | 11) PRODUCT APPROVALS SUBMITTED: |
| | AMARR GARAGE DOORS, SEE TABLE 1606.2B |
| | COMPONENTS & CLADDING WIND LOADS FOR A |
| | BUILDING WITH A MEAN ROOF HEIGHT OF < |
| | 30' LOCATED IN EXPOSURE "B" |
| | |
| | BOTH THE 9' & 16' DOORS OK FOR 2STORY |
| | USE!!!!!!! LOW PRESSURE FOR 3 STORY USE |
| | WITH 1.09 MULTIPLIER 1606.2 D & E. |
| | |
| | 12) PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 2ND REQUEST FOR PRODUCT TESTING REPORTS |
| | FOR THE (G) STRUCTURAL COMPONENTS- |
| | WOOD CONNECTORS!!!!!!!!!!!!!!! |
| | |
| | 13) 2ND REQUEST!!!!PROVIDE THE TRUSS |
| | ENGINEERING SHEETS WITH ALL LOADING |
| | CASES, VERTICAL, HORIZONTAL & GRAVITY |
| | LOADS. PLANS DO NOT INDICATE LOADING, |
| | ONLY THE ALLOWABLE VALUES FOR THE ANCHOR |
| | |
| | 14) 2ND REQUEST: NOT ADDRESSED, |
| | 1503.4.4 PROTECTION AGAINST DECAY & |
| | TERMITES. CONDENSATE LINES & ROOF DOWN |
| | SPOUTS SHALL DISCHARGE AT LEAST 1 FT. |
| | AWAY FROM THE STRUCTURE SIDEWALL, |
| | WHETHER BY UNDERGROUND PIPING, TAIL EX- |
| | TENSIONS, OR SPLASH BLOCKS. |
| | |
| | 15) 2ND REQUEST: GARAGE SWING DOOR, |
| | NOT LISTED ON DOOR SCHEDULE, A 3/4 HR |
| | RATING IS REQUIRED 411.2.6, 705.1.3.5, |
| | DOOR SHALL BE EQUIPPED WITH AN APPROVED |
| | CLOSER. |
| | A) THE FLORIDA BUILDING CODE UNDER |
| | THE ABOVE CODE ARTICLES DOES NOT INDI- |
| | CATE A "C" LABELED DOOR, IT IS A 45 MIN |
| | DOOR. |
| | B) PROVIDE THE CLOSER INFORMATION |
| | REQUIRED. |
| | |
| | LOOK FOR COMMENTS BY THE OTHER PLAN |
| | REVIEW DISCIPLINES THAT MAY BE WRITTEN |
| | ON THE APPLICATION, PLANS, OR ATTACHED |
| | SEPARATELY. WHEN RESUBMITTING PLANS |
| | PLEASE CLEARLY INDICATE THE REVISION AND |
| | REMOVE AND REPLACE ANY PAGES AS NECESS- |
| | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH |
| | THE PLANS WHEN RESUBMITTING PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN |
| | BE FOUND, WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | JIM WITMER |
| | BUILDING PLAN REVIEW |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |