| Plan Review Stops For Permit 04021353 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2005-04-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-04-22 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-04-22 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2005-04-22 00:00:00 | REVISED ROOF SHINGLES TO CERTAINTEED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-03-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-18 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-18 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2005-03-18 00:00:00 | REVISION FROM "A" TO "B" ELEVATION IS OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-08 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-08 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2005-03-08 00:00:00 | SLAB AND FILLED CELL COMPRESSION TESTS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-09-22 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-09-22 |
Time |
14:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-06-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-14 |
Time |
15:27 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2004-06-29 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2004-06-29 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04021353 | | | ADD: 1750 MISSION COURT | | | CONT: WCI | | | TEL: (561)951-2226 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) CORRECT AND RERECORD NOC> | | | | | | 2) PROVISO: PROVIDE INFO FOR THE FIRE | | | RATED GLASS BLOCK. | | | | | | 3)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-03-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-03-23 |
Time |
10:49 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
2004-03-23 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2004-03-23 00:00:00 | 03/23/04 DENIED SEE MASTER 04021355 | | | FOR COMMENTSJW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-03-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-24 |
Time |
09:24 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-03-24 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2005-03-24 00:00:00 | FEEDERS REVISED TO SHOW SE CABLE, | | | HOWEVER PLANS/RISER STILLS SHOWS BEING | | | INSTALLED IN CONDUIT. CALLED ELECTRICAL | | | ENGINEER,CONDUIT IS NOT BEING USED. THIS | | | IS A MISPRINT ON PLANS. | | | CONDUIT CROSSED OUT ON PLANS PER | | | ENGINEER'S REQUEST. | | | | | | | | | WASHER VA REDLINED, SHOULD BE 1500VA | | | 220.16 | | | | | | IF PLANS ARE REVISED FOR ANY FUTURE | | | ITEMS, PLEASE ADJUST THE ABOVE AT THAT | | | TIME. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-09-22 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-09-22 00:00:00 | PASSED UNDER MASTER #04010005 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-07-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-07-14 |
Time |
09:38 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-07-12 |
Time |
07:46 |
Sent To |
|
|
| Notes |
| 2004-07-14 00:00:00 | | | | SEE PERMIT # 04021345 FOR COMMENTS. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-04-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-04-06 |
Time |
07:10 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-04-06 |
Time |
07:10 |
Sent To |
|
|
| Notes |
| 2004-04-06 00:00:00 | | | | PLEASE SEE COMMENTS ON #04021355. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2004-04-12 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-04-12 |
Time |
14:41 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-04-12 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2004-04-12 00:00:00 | PASSED : | | | 1. SEE # 03101412 FOR UNDERGROUND | | | UTILITIES AND SITE WORK. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2004-03-08 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-03-08 |
Time |
16:17 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2004-03-08 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2004-03-08 00:00:00 | FAILED: | | | 1. PLEASE SUBMIT CIVIL PLANS FOR | | | PERMITTING, NOTE THAT CIVIL PLANS WERE | | | REVIEWED UNDER # 03101412 (PLAN REVIEW), | | | AT YOUR OPTION UNDERGROUND UTILITIES & | | | SITE WORK COULD BE UNDER SEPARATE PERMIT | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R, AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-09-22 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-09-22 00:00:00 | PASSED UNDER MASTER#04010005 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-07-20 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-07-20 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-07-20 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2004-07-20 00:00:00 | DENIED********************************** | | | PLEASE SEE COMMENTS ON PERMIT 04021355 | | | | | | NATE MCCRAY, CAPTAIN | | | 561-835-2910 OR 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-05-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-13 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-13 |
Time |
13:08 |
Sent To |
M |
|
| Notes |
| 2005-05-13 00:00:00 | TO "PKRAUSS" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-04-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-13 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-13 |
Time |
10:17 |
Sent To |
B |
|
| Notes |
| 2005-04-13 00:00:00 | TO "RMCDOUGAL" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-03-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-11 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-11 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2005-03-11 00:00:00 | TO "COMM" BD#24/SFR |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-09-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-14 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-14 |
Time |
15:26 |
Sent To |
B |
|
| Notes |
| 2004-09-14 00:00:00 | TO RM DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-06-15 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-06-15 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2004-06-15 00:00:00 | TO COMM BD #28 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-07 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-07 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2004-06-07 00:00:00 | TO COMM BD#28 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-04-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-07 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-03 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2004-03-03 00:00:00 | TO COMM BD#48/ROLLS ON RACK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-03-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-03-26 |
Time |
12:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-09-22 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-03-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-29 |
Time |
12:55 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-03-29 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2004-03-29 00:00:00 | DENIED: | | | 1.PLANS SHALL BE SIGNED WITH ENGINEERS | | | ORIGINAL SIGNATURE AND NOT STAMPED PER | | | FS 471.025. | | | | | | 2.FIRE DAMPERS INDICATED ON PLAN SHEET | | | M-1 UNIT A, RATING APPEARS TO BE AT THE | | | WALL AND CEILING, THE WALL DOES NOT | | | CONTINUE ABOVE THE CEILING.FIRE DAMPER | | | NOT REQUIRED. | | | | | | 3.PLAN SHEET A-21 INDICATES THE | | | FLOOR/CEILING AS A 1HR FIRE RATED | | | ASSEMBLY.UL LISTING FOR L528 DOES NOT | | | INDICATE PENETRATIONS (DUCT) THROUGH | | | RATED ASSEMBLY.PLEASE PROVIDE UL | | | LISTING FOR PENETRATIONS (DUCT). | | | INDICATE IF RADIATION CEILING DAMPER | | | ARE REQUIRED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2005-06-04 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-06-04 |
Time |
08:21 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-06-04 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2005-06-04 00:00:00 | REVISION; | | | ADDED WATER METER TO PLAN |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-03-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-03-26 |
Time |
13:40 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-03-26 |
Time |
13:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-09-22 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-06-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-06-29 |
Time |
12:32 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-06-29 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2004-06-29 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | A) COMMENTS FROM PREVIOUS REVIEWS HAVE | | | NOT BEEN ADDRESSED PROPERLY. COMMENT | | | NUMBER TO STAY THE SAME TO AVOID CONFUS- | | | ION. | | | 3) SHT A-15 GRAB BAR BLOCKING DETAILS | | | SHALL REFLECT BACKING IN CHAPTER 6 OF | | | THE FHA DESIGN MANUAL. - RESPONSE NOTED | | | BUT ONLY THE MEASUREMENTS FOR THE GRAB | | | BARS ARE SHOWN. NO MEASUREMENTS FOR THE | | | BACKING IS SHOWN. PLEASE SEE DESIGN MAN- | | | UAL FOR BACKING FOR THE GRAB BARS FOR | | | THE W/C'S AND SHOWERS. | | | 8)ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | | SHEET. IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | | EERS SHALL LEGIBLY INDICATE THEIR NAME | | | AND LICENSE NUMBER, AS WELL AS, THE NAME | | | ADDRESS AND CERTIFICATE OF AUTHORIZATION | | | NUMBER OF THE ENGINEERING BUSINESS ON | | | EACH SHEET. A TITLE BLOCK WILL SATISFY | | | THIS REQUIREMENT. FAC 61G15-23.002(2) | | | AND FS 471.025. | | | ***************NEW COMMENTS************* | | | 1C) SHT P-1 DOMESTIC WATER SUPPLY DETAIL | | | SHOWS THE WATER SUPPLY UNDER THE SLAB & | | | SHOWS AN ADAPTOR FROM PVC TO COPPER. | | | SUBMIT A DETAIL SHOWING TYPE OF FITTING | | | AND MANUF. SPECIFICATION SHOWING APPROV- | | | AL FOR UNDER SLAB INSTALLATION FOR THE | | | ADAPTOR. SECTION 104.2.1 | | | 2C) SHP P-1 SHOWS MAIN SHUTOFF VALVE IN- | | | SIDE THE GARAGE, BUT PLUMBING GENERAL | | | NOTES #13 INDICATES THAT VALVE SHALL BE | | | LOCATED OUTSIDE OF THE BUILDING. PLEASE | | | CLARIFY AND CORRELATE PLANS AND NOTES. | | | SECTION 104.2.1 | | | 3C) SHT P-1 PLUMBING GENERAL NOTES #19 | | | HAS BEEN DELETED WITH WHITE-OUT. THIS IS | | | NOT APPROVED. PLEASE DELETE NOTE ON PLAN | | | PROPERLY. SECTION 104.2.1.3 | | | 4C) SEE ATTACHED SHEET IN REFERENCE TO | | | FS 553.80(2)(B). FOUT TIMES THE FEE FOR | | | THE PLAN REVIEW PORTION OF THE PERMIT | | | SHALL BE IMPOSED IF THE SAME COMMENTS | | | ARE NOT ADDRESSED PER FLA. STATUTE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-03-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-15 |
Time |
12:40 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-03-15 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2004-03-15 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | A) COMMENTS FROM PREVIOUS REVIEW NOT | | | ADDRESSED. COMMENT NUMBER TO STAY THE | | | SAME AS FIRST REVIEW TO AVOID CONFUSION. | | | 1) INDICATE SPECIFICATION "A" OR "B" AS | | | REQUIRED IN FHA DESIGN MANUAL REQUIRE- | | | MENT 7B PAGES 7.34 & 7.35. - RESPONSE | | | NOTED, BUT SPECIFICATION NOT FOUND ON | | | SHEET A-3 AS INDICATED. | | | 2) SHOW LAV HEIGHT PER FHA DESIGN MANUAL | | | PAGE 9512 SECTION "V". RESPONSE NOTED, | | | BUT 36" IS INCORRECT. 34" IS MAX. HEIGHT | | | 3) SHT A-15 GRAB BAR BLOCKING DETAILS | | | SHALL REFLECT BACKING IN CHAPTER 6 OF | | | THE FHA DESIGN MANUAL. - RESPONSE NOTED, | | | BUT SHEET A-19 DETAIL DOES NOT REFLECT | | | THE DESIGN MANUAL REQUIREMENTS. | | | 4) A SANITARY AND A WATER RISER DIAGRAM | | | ARE REQURED PER SECTION 104.3.1.1. - RE- | | | SPONSE NOTED, BUT NO WATER RISER DIAGRAM | | | HAS BEEN SUBMITTED, | | | 8) PLANS HAVE STAMPED WITH A SIGNATURE | | | STAMP. A WET SIGNATURE IS REQUIRED ON | | | THE SEAL. NO CERTIFICATE OF AUTHORIZAT- | | | ION IS SHOWN ON THE TITLE BLOCK. | | | A PROFESSIONAL ENGINEER SHALL SIGN HIS | | | NAME AND AFFIX HIS SEAL TO ALL PLANS, | | | SPECIFICATIONS, REPORTS AND FINAL BID | | | DOCUMENTS PROVIDED TO THE OWNER OR THE | | | OWNER'S REPRESENTATIVE, OR OTHER DOCU- | | | MENTS PREPARED OR ISSUED BY SAID REGIS- | | | TRANT AND BEING FILED FOR PUBLIC RECORD. | | | THE DATE THAT THE SIGNATURE AND SEAL IS | | | AFFIXED AS PROVIDED HEREIN SHALL BE EN- | | | TERED ON SAID PLANS, SPECIFICATIONS, RE- | | | PORTS, OR OTHER DOCUMENTS IMMEDIATELY | | | UNDER THE SIGNATURE OF THE PROFESSIONAL | | | ENGINEER, FAC 61G15-23.002(1) | | | FS 471.025 | | | EACH SHEET OF PLANS AND PRINTS WHICH | | | MUST BE SEALED UNDER THE PROVISIONS OF | | | CHAPTER 471 SHALL BE SEALED, SIGNED AND | | | DATED BY THE PROFESSIONAL ENGINEER IN | | | RESPONSIBLE CHARGE. FAC 61G15-23.002(2) | | | FS 471.025 | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | | SHEET. IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | | EERS, ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME AND LICENSE NUMBER, AS WELL | | | AS, THE NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. A TITLE BLOCK | | | WILL SATISFY THIS REQUIREMENT. FAC | | | 61G15-23.002(2) - FS 471.025 | | | **************NEW COMMENT*************** | | | 1B) CLEAR FLOOR SPACE SHALL BE APPLIED | | | OR SUPERIMPOSED OVER A PLAN DURING THE | | | DESIGN PROCESS TO DETERMINE IF SPACE RE- | | | QUIREMENTS ARE BEING MET. PAGE 7.43 OF | | | THE DESIGN MANUAL. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-07-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-21 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-07-21 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2004-07-21 00:00:00 | APPROVED BY ERIC SCHNEIDER, SENIOR | | | PLANNER |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2004-03-22 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-03-22 00:00:00 | 1.NEED SITE & LANDSCAPE PLANS. | | | 2. AREA TABULATION INCORRECT | | | UNIT#2 TOTAL A/C | | | UNIT#3 TOTAL A/C & UNIT TOTAL | | | 3. BUILDINGS LARGER THAN ORIGINALLY | | | APPROVED-SETBACKS MUST BE MET IN | | | SITE PLAN | | | 4. SHEET A-6 INCORRECT SCALE SHOWN | | | 5. MUST SHOW BUILDING HEIGHT MEETS CODE | | | REQUIREMENTS ON ELEVATIONS SHEETS | | | A-7,A-8 |
|
|