Plan Review Details - Permit 04021308
Plan Review Stops For Permit 04021308
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-05-24 Cont ID  
Sent By jwitmer Date 2004-05-24 Time 15:37 Rev Time 0.00
Received By jwitmer Date 2004-05-24 Time 15:37 Sent To  
Notes
2004-05-24 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04021308
 ADD: N CONGRESS
 CONT: CONTRAVEST
 TEL: (407)509-9701
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1ST REVIEW
 ACTION: DENIED
  
 PLANS ARE INCOMPLETE, THERE ARE DESIGN
 PROBLEMS, SEE COMMENTS FROM BLDG# 1,
 04021300.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-05-04 Cont ID  
Sent By dpalmer Date 2004-05-04 Time 20:35 Rev Time 0.00
Received By dpalmer Date 2004-05-04 Time 20:35 Sent To  
Notes
2004-05-04 00:00:00UNSAT
  
 PLEASE SEE NOTES UNDER, 04021300

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2004-03-04 Cont ID  
Sent By mamini Date 2004-03-04 Time 13:24 Rev Time 1.00
Received By mamini Date 2004-03-04 Time 13:24 Sent To  
Notes
2004-03-04 00:00:00FAILED:
 1. PLEASE PROVIDE SITE ASSESSMENT REPORT
 AND REMEDIAL ACTION PLAN IF ANY,
 ENVIRONMENTAL PROBLEMS HAVE BEEN DICOVER
 IN ADJACENT DEVELOPMENTS.
 2. PLEASE INCLUDE POLLUTION/EROSION AND
 DUST CONTROL IN CIVIL PLANS, IT MUST BE
 INSTALLED IN THE FIELD PRIOR TO ANY
 EARTH/EXCAVATION WORK.
 3. PLEASE PROVIDE STORM WATER CALC. FOR
 OUR REVIEW.
 4. PLEASE PROVIDE CALCULATION FOR THE
 PROPOSED LIFT STATION.
 5. COPY OF THE SFWMD PERMIT MUST ALSO
 BE SUBMITTED.
 6. PLEASE SHOW DUMPSTERS LOCATION, IF
 CITY PICK UP, THEN SIZE PER CITY
 REQUIRMENTS.
 7. PARKING STALLS MUST BE PAINTED WITH
 DOUBLE 4" STRIPES, PER CITY REQUIRMENT.
 8. DRIVEWAY APPROACHES MUST BE CONSTR.
 WITH 6" CONCRETE FROM THE EDGES OF
 PAVEMENT TO THE PROPERTY LINE.
 9. WORK WITHIN PUBLIC R.O.W REQUIRES
 SEPARATE PERMIT FROM CITY ENGINEER'
 OFFICE, NOTE TO G.C., 659-8040.
 10. PLEASE SUBMIT CIVIL PLANS ONLY TO
 PUBLIC UTILITIES & ENGINEERING FOR ALL
 THE CONNECTION TO CITY SERVICES, ATT;
 MANNY GONZALEZ, 659-8040 EXT. 2306.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-05-10 Cont ID  
Sent By pkrauss Date 2004-05-10 Time 11:10 Rev Time 0.00
Received By pkrauss Date 2004-05-10 Time 11:10 Sent To  
Notes
2004-05-10 00:00:00SEE COMMENTS ON PERMIT 04021300

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-06-02 Cont ID  
Sent By kstevens Date 2004-06-02 Time 08:24 Rev Time 3.00
Received By kstevens Date 2004-06-02 Time 08:24 Sent To  
Notes
2004-06-02 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FBC-2001 BUILDING
 FHA-98 AMEND. DESIGN MANUAL
  
 SEE COMMENTS ON PERMIT NUMBER 04021300
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-06-07 Cont ID  
Sent By mmclean Date 2004-06-07 Time 16:43 Rev Time 0.00
Received By mmclean Date 2004-06-07 Time 16:43 Sent To  
Notes
2004-06-07 00:00:00APPROVED BY JOSH LONG, PLANNER 659-8031