Plan Review Details - Permit 04021243
Plan Review Stops For Permit 04021243
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-12-15 Cont ID  
Sent By rmcdouga Date 2005-12-15 Time 10:19 Rev Time 0.00
Received By rmcdouga Date 2005-12-15 Time 10:19 Sent To  
Notes
2005-12-15 00:00:00REVISION TO CHANGE ROOF TILE
 MANUFACTURER. SUBMITTED NEW PRODUCT
 APPROVAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-09-20 Cont ID  
Sent By rmcdouga Date 2004-09-20 Time 13:33 Rev Time 0.00
Received By rmcdouga Date 2004-09-20 Time 13:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-07-20 Cont ID  
Sent By jleech Date 2004-09-16 Time 18:37 Rev Time 2.50
Received By rmcdouga Date 2004-07-20 Time 09:22 Sent To  
Notes
2004-07-20 00:00:00DENIED
  
 1) THE TWO HOUR FIRE RATED WALLS ARE
 NOT REQUIRED FOR TYPE VI CONSTRUCTION.
 PLEASE REMOVE THE NOTE ON SHEET A1
 SPECIFYING A 2 HOUR RATED WALL WITHIN
 20 FEET OF THE PROPERTY LINE.
  
 2) REVISE THE ATTIC ACCESS NOTE ON SHEET
 A4 FROM 97 FBC TO 2001 FBC.
  
 3) ON SHEET A8 A SIMPSON SUR/L 210 IS
 SPECIFIED ATTACHED TO MASONRY WALL. THE
 PROPER CONNECTOR FOR ATTACHING TO
 MASONRY WITH TITEN SCREWS IS THE SIMPSON
 HUSUL/R 26-2.
  
 4) THE BUILDING SECTION ON A9 SPECIFIES
 LATH AND STUCCO OVER PLYWOOD AND WOOD
 FRAME AT THE SECOND FLOOR. THE PLANS
 SHOW THE SECOND FLOOR IS MASONRY. THE
 H3 CONNECTOR SPECIFIED SHOULD BE A
 HETAL 16. PLEASE CORRECT.
  
 5)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72.
 PLEASE ATTACH COVER SHEETS FROM THE FL
 PRODUCT APPROVAL WEB SITE WITH THE STATE
 FL #. IF THE PRODUCT DOES NOT HAVE STATE
 PRODUCT APPROVAL, SUBMIT APPLICATION FOR
 LOCAL PRODUCT APPROVAL.
  
 6) SUBMIT ENERGY CALCULATION FORMS FOR
 EACH OF THE TWO CONDITIONED BUILDINGS ON
 THE PERMIT. SEE FBC 13-101.2.5.1 AND
 101.2.5.2. THE PLAYROOM IN THE DETACHED
 GARAGE MUST USE SUB-CHAPTER 4 TO
 DEMONSTRATE COMPLIANCE.
  
 7) THERE IS NO WINDOW AND DOOR SCHEDULE
 FOR THE DETACHED GARAGE AND THE ID
 MARKS DO NOT CORRESPOND WITH THE
 SCHEDULE ON A3. PLEASE CORRECT.
  
 IF YOU HAVE QUESTIONS PLEASE CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-05-18 Cont ID  
Sent By jleech Date 2004-07-10 Time 10:28 Rev Time 4.00
Received By rmcdouga Date 2004-05-17 Time 15:11 Sent To  
Notes
2004-05-17 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) FIRM LICENSE NUMBER IS MISSING FROM
 THE TITLE BLOCK. SEE FAC 61G1-16.04.
  
 3) REVISE CONSTRUCTION TYPE ON SHEET A1
 TO TYPE VI UNPROTECTED. FBC TABLE 600
 REQUIRES EXTERIOR BEARING WALLS WITHIN
 20 FEET OF THE PROPERTY LINE TO HAVE A
 2 HOUR FIRE RATING.
  
 4) PROVIDE A CLEAR SECTION DETAIL OF THE
 PARAPET WALLS.
  
 5) SPECIFY ON THE PLAN THAT THE WWM IN
 THE SLAB WILL BE SUPPORTED AT 3'OC AS
 REQUIRED BY FBC 1909.3.
  
 6)FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
 SPECIFY THE ABOVE INFORMATION FOR THE
 RESIDENCE AND THE DETACHED GARAGE.
  
 7) SPECIFY THE BOTTOM CORD LIVE LOAD FOR
 THE ATTIC SPACE. SEE FBC TABLE 1604.1.
  
 8) THERE IS A DISCREPANCY IN THE
 DIMENSIONS AT THE REAR OF THE STRUCTURE
 BETWEEN THE FOUNDATION PLAN AND THE
 FIRST FLOOR PLAN. PLEASE CORRECT.
  
 9) IN THE FIREBLOCKING NOTE ON A3 CHANGE
 THE CODE REFERENCED FROM SBC TO 2001 FBC
 REVISE SCHEDULE NOTE 5 TO 2001 FBC.
  
 10) ON SHEET A4 REVISE HANDRAIL NOTES
 AND ATTIC ACCESS NOTE TO FBC.
  
 11) SCUPPERS, OVERFLOW SCUPPERS AND
 LEADERS SHALL BE SIZED AND DISCHARGED IN
 ACCORDANCE WITH THE 2001 FBC PLUMBING
 PER FBC 1503.4.4 AND 1503.4.2. SPECIFY
 SIZES ON THE PLAN.
  
 12) ON SHEET A5 THE LEFT SIDE ELEVATION
 IS LESS THAN 10 FEET FROM THE PROPERTY
 LINE, FBC TABLE 600 ALLOWS 20% OF THE
 WALL AREA AS OPENINGS. PLEASE CORRECT
 THE CALCULATIONS.
  
 13)NOTE 6 ON A3 SPECIFIES IMPACT RESIST-
 ANT GLAZING AND THE NOTE ON A5 REFERS TO
 HURRICANE PANELS. PLEASE CLARIFY.
  
 14) REVISE THE DRAFTSTOP NOTE ON A7 TO
 REFERENCE THE FBC.
  
 15) CORRECT THE TYPO IN THE BEAM
 SCHEDULE ON A7 TO B10 FROM B0.
  
 16) REVISE THE SEMCO STRAPS SPECIFIED ON
 A7 TO A CURRENT STRAP WITH STATE PRODUCT
 APPROVAL.
  
 17)1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23. REVISE THE UPLIFT VALUE OF
 THE SIMPSON HETAL 20 TO 1810#, WHICH IS
 THE VALUE GIVEN IN THE CURRENT CATALOG
 THAT DOESN'T INCLUDE A ONE THIRD
 INCREASE IN THE STEEL CALCULATIONS.
  
 18) UPDATE THE NOTES ON A9 TO REFERENCE
 THE 2001 FLORIDA BUILDING CODE.
  
 19) REVISE THE ROOF NOTES ON DETAILS 2
 AND 3 ON A12 TO REFERENCE 2001 FBC.
  
 20) SPECIFY THE LENGTH/EMBED DEPTH OF
 THE 3/16" DIA. TAP CONS IN DETAIL 10 ON
 A12.
  
 21) SPECIFY THE LENGTH/EMBED DEPTH OF
 THE 5/8" DIA. EXPANSION ANCHORS AT THE
 2X8 LEDGER IN DETAIL 3 ON A12.
  
 22) SPECIFY THE LENGTH/EMBED DEPTH OF
 THE EXPANSION ANCHORS FOR LEDGERS.
  
 23) THE ID TAG AT THE GARAGE DOOR ON THE
 FLOOR PLAN ON A14 IS INCORRECT. IT
 SHOULD READ 1 ON A13.
  
 24) THE TWO FRONT WINDOWS ON THE SECOND
 FLOOR PLAN ON A14 DO NOT HAVE ID TAGS.
  
 25) SPECIFY ON THE PLANS IF DETACHED
 GARAGE IS TO HAVE IMPACT RESISTANT
 WINDOWS OR STORM PANELS.
  
 26) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SUBMIT
 STATE OR LOCAL PRODUCT APPROVAL
 INFORMATION IN ADDITION TO PRODUCT NOAS.
  
 27) SUBMIT STATE/LOCAL PRODUCT APPROVAL
 FOR THE FOLLOWING ITEMS SHOWN ON PLANS:
 - ARCHED TOP INSWING ENTRY DOOR
 - ARCHED TOP WINDOW
  
 28) SUBMIT ENERGY CALCULATIONS FOR THE
 HOUSE WITH 2592 SQFT OF CONDITIONED
 SPACE AND DETACHED GARAGE WITH 372 SQFT
 OF CONDITIONED SPACE. EACH STRUCTURE IS
 REQUIRED TO HAVE A FORM AND CALCS.
  
 29) SPECIFY ON THE PLANS THE INSULATION
 FOR THE WALLS, FLOORS AND CEILING OF THE
 PLAYROOM IN THE DETACHED GARAGE.
  
 30) THE TWO STORY WALL SECTION 3 ON A12
 SPECS. R19 BATT INSULATION AND THE
 ENERGY CALCS. SPECIFY R30 INSULATION.
 PLEASE CORRECT.
  
 31) SEE ADDITIONAL NOTES ON THE REVIEWED
 PLANS.
  
 32)PLEASE RETURN ONE SET OF OLD DRAWINGS
 WITH NEW PLANS IN ORDER TO EXPEDIATE
 PLAN REVIEW.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-12-29 Cont ID  
Sent By dpalmer Date 2005-12-29 Time 09:35 Rev Time 0.00
Received By dpalmer Date 2005-12-29 Time 08:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-08-27 Cont ID  
Sent By dpalmer Date 2004-08-27 Time 07:11 Rev Time 0.33
Received By dpalmer Date 2004-08-27 Time 06:57 Sent To P
Notes
2004-08-27 00:00:00REDLINED NOTE FOR SECOND FLR PLAYRM.
 RECEPTS ARE ALL SHOWN AS GFI?
 ONLY RECEPTS IN GARAGE ARE REQUIRED TO
 BE GFI/GFI PROTECTED.210.8
 IF GFI PROTECTION IS DESIRED ON 2ND FLR
 PLAYRM, IT IS PERMITTED.
  
 ** THIS IS ONLY A NOTE **

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-07-06 Cont ID  
Sent By csiegber Date 2004-08-24 Time 14:39 Rev Time 0.75
Received By dpalmer Date 2004-07-06 Time 14:59 Sent To P
Notes
2004-07-06 00:00:00************* UNSAT *****************8
  
 1)NOTE: PLEASE SEE A NEW TITLE BLOCK
 HAS BEEN ADDED FOR "HILLERS ENGINEERING"
 PLEASE PROVIDE ALL LICENSE #'S AS
 REQUIRED UNDER FAC 61G15-23.002. FS 471.
 023. PLEASE ALSO SEE "LEGAL SIGNATURE"
 MUST BE SIGNED. PLEASE VERIFY IF INITIAL
 AS SIGNED IS LEGAL SIGNATURE.
 PLEASE PROVIDE A SIGNED,DATED AND SEALED
 NOTORIZED LETTER FOR SIGNATURE.
  
 2)NOTE: PLEASE SHOW GROUNDING AT DETACH-
 -ED BLDG PER 250.32. PLEASE ALSO SEE
 250.50 FOR GROUNDING ELECTRODE SYSTEM TO
 BE SHOWN TO CWP, FOOTER STEEL.
  
 3)NOTE: PLEASE SEE A/C SYSTEM FOR GARAGE
 WHICH IS NOW SHOWN ON PANEL SCHEDULE.
 SHOWS CU AS 2-POLE AND AHU AS 1-POLE?
 THIS SYSTEM IS NOT SHOWN IN ANY LOAD
 CALCS.
  
 4)NOTE: PANEL "A" IS NOT SHOWN ON MDP.
 OCP? 200A?
  
 NOTES 1,2,3 PREVIOUS NOTES.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-04-26 Cont ID  
Sent By csiegber Date 2004-07-02 Time 11:29 Rev Time 0.75
Received By dpalmer Date 2004-04-26 Time 07:13 Sent To M
Notes
2004-04-26 00:00:00************ UNSAT ************
  
 1)NOTE: PLEASE SEE FAC 61G15-23.002,
 FAC 61G1-16.004, FS 471.023 AND FS 481.
 219. PLANS ARE REQ'D TO HAVE ALL INFOR-
 -MATION ON TITLE BLOCKS AS REQ'D PER
 ABOVE. PLANS ARE REQ'D TO HAVE TITLE BLK
 PLEASE ALSO SEE MISSING REQ'D LICENSE
 #'(S).
 PLEASE SEE THIS COMMENT STANDS FOR ALL
 PLANS AND FOR ALL TRADES WEATHER OR NOT
 COMMENT IS MADE BY OTHER REVIEWER.
  
 2)NOTE: PLEASE GARAGE NEEDS MORE INFOR-
 -MATION FOR THE FOLLOWING.
 MEANS OF DISC TO BE INDICATED,PER 225.31
 GROUNDING ELECTRODE PER 250.32
 LTS PER 210.70. NONE SHOWN FOR FRIST
 AND SECOND FLR?
 PLEASE ALSO SEE SWITCH IN MAIN HOUSE
 MENTIONS TO SW LT IN GARAGE? THIS MAY
 NOT BE PERMITTED UNLESS MEETING 225.31
 250.32,230.72 ETC.
 A/C UNTI NOT SHOWN ON ROOF W/ REQ'D
 GFI RECEPT PER 210.63,DISC PER 440.11.
 SD'S WILL BE REQ'D ON FIRST AND SECOND
 FLR. PER NFPA-72 8-1.4.2
  
 3)NOTE: PLEASE SEE 210.52C 1-5 FOR SPAC-
 -ING OF KITCHEN COUNTERSPACE RECEPTS.
 PLEASE SHOW ALL MIN REQ'D, INCLUDING
 PENINSULAR.
  
 4)NOTE: PLEASE SEE 210.8A6 FOR ALL RECEP
 -TS SERVING COUNTERSPACE TO BE GFI/GFI
 PROTECTED.
  
 5)NOTE: PLEASE SEE AHU'S ARE MISSING
 FROM PANEL SCHEDULE. PLEASE PROVIDE KW
 RATING FOR EACH UNIT. LOAD CALCS SHOW
 10KW TOTAL LOAD FOR BOTH?
 PLEASE CORRELATE WITH MECH PLANS. SHOW
 TWO 10KW UNITS. PLEASE ADJUST LOAD CALCS
 TO REFLECT LOADS.
  
 6)NOTE: PLEASE SEE LOAD SHOWN FOR MICRO-
 -WAVE ON LOADS CALCS. SHOWS 7.5KW FOR
 MICRO?
  
 7)NOTE: PLEASE SEE GARAGE A/C UNIT NOT
 LISTED ON GARAGE PANEL?
 PLEASE ALSO VERIFY IN LOAD CALCS.
  
 8)NOTE: PLEASE SEE NOTES BELOW RISER
 DIAGRAM. MENTIONS "ONE AMP BRANCH CIR-
 -CUIT" PLEASE ADJUST, MISPRINT?
  
 9)NOTE: PLEASE PROVIDE ROOM DESINATIONS
 ON PLANS.
  
 10)NOTE: PLEASE SEE RISER, SHOWS TWO
 PANEL "A"S.
  
 11)NOTE: PLEASE SHOW LT ETC REQ'D FOR
 AHU SHOWN TO BE IN ATTIC. 210.70
  
 12)NOTE: PLEASE CLARIFY, PLANS SHOW
 ELECTRIC WATER HEATER, YET LOAD CALCS
 INDICATE GAS?
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2005-12-28 Cont ID  
Sent By adarroug Date 2005-12-28 Time 09:45 Rev Time 0.00
Received By adarroug Date 2005-12-28 Time 09:45 Sent To E
Notes
2005-12-28 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-12-14 Cont ID  
Sent By adarroug Date 2005-12-14 Time 16:27 Rev Time 0.00
Received By adarroug Date 2005-12-14 Time 16:27 Sent To B
Notes
2005-12-14 00:00:00TO "RMCDOUGAL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-04-28 Cont ID  
Sent By adarroug Date 2005-04-28 Time 16:29 Rev Time 0.00
Received By adarroug Date 2005-04-28 Time 16:29 Sent To M
Notes
2005-04-28 00:00:00TO "PKRAUSS" BOX/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-04-18 Cont ID  
Sent By adarroug Date 2005-04-18 Time 09:00 Rev Time 0.00
Received By adarroug Date 2005-04-18 Time 09:00 Sent To M
Notes
2005-04-18 00:00:00TO "PKRAUSS" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-08-24 Cont ID  
Sent By csiegber Date 2004-08-24 Time 14:39 Rev Time 0.00
Received By csiegber Date 2004-08-24 Time 14:39 Sent To E
Notes
2004-08-24 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-07-02 Cont ID  
Sent By csiegber Date 2004-07-02 Time 11:29 Rev Time 0.00
Received By csiegber Date 2004-07-02 Time 11:29 Sent To E
Notes
2004-07-02 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-04-22 Cont ID  
Sent By alange Date 2004-04-22 Time 13:54 Rev Time 0.00
Received By alange Date 2004-04-22 Time 13:54 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-05-18 Cont ID  
Sent By rmcdouga Date 2004-05-18 Time 07:28 Rev Time 0.00
Received By rmcdouga Date 2004-04-16 Time 14:44 Sent To  
Notes
2004-04-16 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2005-05-03 Cont ID  
Sent By prafter Date 2005-05-03 Time 11:13 Rev Time 0.50
Received By prafter Date 2005-05-03 Time 11:13 Sent To  
Notes
2005-05-03 00:00:00SECOND REV. PLAN REVIEW:
  
 NEW A/C PLANS WITH SIZING MARKED.
  
 PR.5/3/05

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-04-22 Cont ID  
Sent By pkrauss Date 2005-04-22 Time 15:03 Rev Time 0.30
Received By pkrauss Date 2005-04-22 Time 15:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-05-17 Cont ID  
Sent By dpalmer Date 2004-04-26 Time 07:13 Rev Time 0.00
Received By rmcdouga Date 2004-05-17 Time 15:11 Sent To  
Notes
2004-05-17 00:00:00OK PER P. KRAUSS 4-28-04RM

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-09-16 Cont ID  
Sent By jleech Date 2004-09-16 Time 18:37 Rev Time 0.50
Received By jleech Date 2004-09-16 Time 18:37 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-07-10 Cont ID  
Sent By dpalmer Date 2004-08-27 Time 07:11 Rev Time 0.50
Received By jleech Date 2004-07-10 Time 10:28 Sent To B
Notes
2004-07-10 00:00:00PLEASE SEE ELECTRICAL PLAN REVIEW NOTE 1
 ALL INFORMATION ON PAGE 9 SHOULD BE ON
 ONE PAGE NOT TWO.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-05-08 Cont ID  
Sent By dpalmer Date 2004-07-06 Time 16:09 Rev Time 0.33
Received By jleech Date 2004-05-08 Time 06:29 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-04-22 Cont ID  
Sent By sgraham Date 2004-04-22 Time 10:20 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***