| Plan Review Stops For Permit 04021148 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-12-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-12-08 |
Time |
07:40 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2004-12-08 |
Time |
07:40 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-07-14 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-07-14 |
Time |
14:11 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2004-07-14 |
Time |
14:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-06-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-06-19 |
Time |
15:28 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2004-06-19 |
Time |
15:28 |
Sent To |
PC |
|
| Notes |
| 2004-06-19 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04021148 | | | ADD: 2421 OKEECHOBEE BLVD | | | CONT: SOUTHEAST CONSTRUCTION | | | TEL: (561)282-7610 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | PLANS ARE FOUND TO BE CODE COMPLIANT: | | | **************************************** | | | BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-05-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-05-13 |
Time |
11:20 |
Rev Time |
0.99 |
| Received By |
jwitmer |
Date |
2004-05-13 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2004-05-13 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04021148 | | | ADD: 2421 OKEECHOBEE BLVD | | | CONT: SOUTHEAST CONSTRUCTION | | | TEL: (561)282-7610 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-04-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-04-02 |
Time |
15:38 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2004-04-02 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2004-04-02 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04021148 | | | ADD: 2421 OKEECHOBEE BLVD | | | CONT: SOUTHEAST CONSTRUCTION | | | TEL: (813)251-6802 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | WHERE THE BEARING CAPACITY OF THE SOIL I | | | S NOT DEFINITEY KNOWN, OR IS IN QUESTION | | | THE BUILDING OFFICIAL MAY REQUIRE EXPLOR | | | ATIONS, TEST OR OTHER ADEQUATE PROOF AS | | | TO THE PERMISSIBLE SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | | NICALREPORT FROM A DESIGN PROFESSIONAL P | | | ROPERLY LICENSED IN THE STATE OF | | | FLORIDA. | | | | | | 3) FL BLD CODE CHAP 13 ENERGY EFFICENCY | | | PROVIDE ENERGY CALS/ W MANUAL "J" | | | | | | 4) BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH CO.,THE PERMIT PLANS STAMPED BY | | | THEM AND THE RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. | | | | | | 5)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | PROVIDE THE MINIMUM BUILDING TYPE: | | | | | | 6) BUILDING IS LOCATED IN THE "FIRE | | | DISTRICT", SEE REQUIREMENTS FOR "FIRE | | | DISTRICT", NO TYPE VI BUILDINGS ALLOWED, | | | EXTERIOR WALLS NOT TO COMBUSTIBLE, SEE | | | PLYWOOD SHEATHING. | | | | | | 7) ADD INFO PLANS INDICATE THE USE OF | | | 6" 16 GA STEEL STUDS BUT THE CONNENCTION | | | OF THE TOP AND BOTTOM PLATES TO VARIOUS | | | MATERIALS IS NOT GIVEN , SEE A3 DETAIL | | | # 2, SHEET# 3A DETAIL 1 ALSO. | | | | | | 8) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) FIXED WINDOWS | | | B) MULLIONS, HORIZONTAL/ VERTICAL | | | C) SWING DOOR | | | D) ROOFING ASSEMBLIES | | | E) STORM PANELS | | | **************IMPORTANT************** | | | 9)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 10) 1707.4.5.1 MULLIONS OCCURRING | | | BETWEEN INDIVIDUAL WINDOW AND GLASS | | | DOOR ASSEMBLIES. TESTING REPORTS ARE | | | REQUIRED BY AN APPROVED TESTING | | | LABORATORY OR BE ENGINEERED. | | | | | | 11) 1707.4.5.2 MULLIONS SHALL BE DESIGN- | | | ED TO TRANSFER THE DESIGN PRESSURE LOADS | | | APPLIED BY THE WINDOW OR DOOR ASSEMBLIES | | | TO THE ROUGH OPENING SUBTRATE. | | | | | | 12) CHECK WINDOW AND DOOR PRESSURES TO | | | TABLE 1606.2B, BOTH POSITIVE & NEGITIVE | | | PRESSURES ARE LOW. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2004-11-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-18 |
Time |
18:03 |
Rev Time |
0.20 |
| Received By |
dpalmer |
Date |
2004-11-18 |
Time |
18:03 |
Sent To |
|
|
| Notes |
| 2004-11-18 00:00:00 | NO ELECTRICAL COULD BE LOCATED ON PLANS | | | SUBMITTED. | | | REV COVER SHEET WAS CHECKED OFF FOR AN | | | ELECTRICAL REVIEW?? |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-03-09 |
Time |
09:04 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-03-09 |
Time |
07:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-05-04 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-05-04 |
Time |
11:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-03-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-03-02 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-03-02 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2004-03-02 00:00:00 | 1) PLEASE INDICATE ANY AND ALL | | | SAFEGUARDS THAT WILL BE TAKEN FOR | | | SAFETY. WILL THE EXISTING RESTAURANT | | | REMAIN OPEN OR CLOSED DURING THE | | | RENOVATIONS. PLEASE ADVISE. | | | | | | 2) PLEASE INDICATE NEW OCCUPANT LOAD | | | BASED ON NEW SEATS PLANNED FOR THE | | | ADDITION. | | | | | | 3) PANIC HARDWARE REQUIRED ON EXIT DOORS | | | IF DOORS ARE SUBJECT TO 100 OR MORE | | | PERSONS. | | | | | | 4) PLEASE INDICATE SEATING LOCATIONS | | | FOR THE HANDICAPPED IN THE EXISTING | | | OR NEW CONSTRUCTION AREAS. | | | | | | 5) ALL CONSTRUCTION, DEMOLITITON, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-11-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-11-16 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-11-16 |
Time |
13:19 |
Sent To |
E |
|
| Notes |
| 2004-11-16 00:00:00 | SENT TO COMM BD#9 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-03 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-03 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2004-06-03 00:00:00 | TO COMM BD#19 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-04-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-30 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-30 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2004-04-30 00:00:00 | TO COMM BD#17 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-02-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-25 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-25 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2004-02-25 00:00:00 | TO COMM BD#36 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-06-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-10 |
Time |
07:21 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-06-10 |
Time |
07:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-05-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-05-05 |
Time |
07:19 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-05-05 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2004-05-05 00:00:00 | DENIED: | | | RESPONSE TO COMMENT #1 FROM REVIEW | | | DATED 3-24-04: | | | CONDENSATE FROM THE ROOFTOP UNIT IS TO | | | DISCHARAGE ONTO ROOF. | | | | | | 1.PLEASE CLARIFY, WILL CONDENSATE BE | | | PIPED FROM THE UNIT TO THE GENERAL | | | VICINITY OF THE SCUPPER OR IS IT THE | | | INTENT TO JUST LET IT RUN DOWN THE ROOF | | | & GRAVITY TO DIRECT WATER TO SCUPPER? | | | PLEASE NOTE, PER 2001 FBC(M) 307.2.1.#3, | | | DISCHARGE SHALL NOT CAUSE A NUISANCE. | | | | | | 2.WHERE DOES THE SCUPPER TERMINATE? | | | PLAN SHEET A0 INDICATES A SIDEWALK. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-03-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-24 |
Time |
12:25 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2004-03-24 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2004-03-24 00:00:00 | DENIED: | | | 1.PROVIDE ADDITIONAL INFORMATION ON | | | THE CONDENSATE.PER CITY CODE SEC. | | | 90-125 (5), CONDENSATE SHALL TERMINATE | | | INTO THE STORM DRAIN.PER 2001 FBC(M) | | | 307.2.1. #1, UNITS LARGER THAN 6 TON, | | | CONDENSATE SHALL TERMINATE INTO STORM | | | DRAIN OR AN APPROVED DRY WELL. | | | | | | 2.PLEASE PROVIDE ENERGY CALCULATIONS | | | PER 2001 FBC CHAPTER 13 SUB-CHAPTER 400. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-06-18 |
Time |
16:49 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-06-18 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2004-06-18 00:00:00 | NO PLUMBING PLANS SUBMITTED - ALL ROOF | | | COMMENTS ADDRESSED EXCEPT PROVISO ON | | | SLOPE OF GUTTER. GUTTER SHALL SLOPE @ | | | 1/4" PER FT. KSTEVENS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-05-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-05-15 |
Time |
17:41 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-05-15 |
Time |
17:41 |
Sent To |
|
|
| Notes |
| 2004-05-15 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | | | | 1) CALCULATIONS FOR UPPER ROOF DO NOT | | | SHOW 1/2 AREA OF VERITCAL WALLS AS REQ- | | | QUESTED. THE ROOF AREA AS SCALED OUT IS | | | THE SAME AS INDICATED ON CALCULATIONS | | | WITH VERTICAL WALLS, (PARAPETS), ADDED. | | | SHOW DIMENSIONS OF ROOF AREA AND SHOW | | | HEIGHT OF PARAPETS TO CONFIRM CALCULAT- | | | IONS. | | | 2) SUBMIT THE SAME INFORMATION FOR LOW- | | | ER ROOF. SUBMIT A DETAIL FOR LOWER ROOF | | | SHOWING GUTTER AND DOWNSPOUT INDICATED | | | IN CALCULATIONS ON SHT A4. 5" GUTTER IS | | | NOT SUFFICIENT FOR THE ROOF AREA TO BE | | | DRAINED PER TABLE 1106.6. SHOW SLOPE OF | | | GUTTER AND SHOW HIGH POINT OF GUTTER AND | | | LOCATION OF DOWNSPOUT. INDICATE SLOPE OF | | | GUTTER. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-03-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-06 |
Time |
08:24 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-03-06 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2004-03-06 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | FBC-2001 CHAPTER 1 | | | | | | 1) ROUTE PLANS TO THE DEPT. OF BUSINESS | | | REGULATION HOTEL AND RESTAURANT DIVISION | | | FOR REVIEW. 201 W BROWARD BLVD. SUITE | | | 104 FT. LAUDERDALE FLA. (954) 958-5520 | | | SECTION 104.1.7 | | | 2) SHT A1A IF BEVERAGE BAR HAS WATER | | | SUPPLY, A WATER RISER DIAGRAM SHALL BE | | | REQUIRED PER SECTION 104.3.1.1 | | | 3) SHT A4 ROOF PLAN, SUBMIT CALCULATIONS | | | FOR UPPER ROOF PRIMARY AND SECONDARY | | | ROOF DRAINS PER SECTIONS 1106 & 1107 | | | AND ALL SUBSECTIONS. SHOW SQUARE FEET OF | | | ROOF & 1/2 AREA OF ALL VERTICAL WALLS | | | INCLUDING PARAPETS. | | | 4) SHT A4 ROOF PLAN, SUBMIT CALCULATIONS | | | FOR LOWER ROOF. SHOW LOCATION AND SIZE | | | OF PRIMARY AND SECONDARY ROOF DRAINS. | | | SHOW SQUARE FEET OF LOWER ROOF AND SHOW | | | 1/2 AREA OF ALL VERTICAL WALLS INCLUDING | | | PARAPETS. SHOW SQUARE FEET OF UPPER ROOF | | | BEING ADDED TO LOWER ROOF. SHOW SIZE OF | | | ALL RWL PIPING AND OR DOWNSPOUTS FOR | | | EXISTING ROOF. IF LOWER ROOF IS SLOPED, | | | INDICATE SLOPE ON PLANS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-04-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-04-05 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-04-05 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2004-04-05 00:00:00 | APPROVED BY JOSH LONG PLANNER 659-8031 M | | | M |
|
|