| Plan Review Stops For Permit 04021143 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-07 |
Time |
15:16 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2004-04-28 |
Time |
12:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-04-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-28 |
Time |
06:07 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2004-04-06 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2004-04-06 00:00:00 | DENIED | | | 1.PRODUCT APPROVAL FOR ENTRY DOOR | | | MISSING.SUBMIT 2 COPIES. | | | APPICATIONS FOR LOCAL AND OR STATE | | | SITE SPECIFIC PRODUCT APPROVAL NOT | | | REQUIRED IF THE PRODUCT IS LISTED ON | | | THEFBC PRODUCT APPROVAL SITE.ALL | | | PRODUCT APPROVALS SUBMITTED ARE ON THE | | | FBC SITE.PLEASE REMOVE APPLICATIONS. | | | | | | 2.VALUATION OF $166,800 IS TO LOW | | | BASED UPON SBCCI BUILDING VALUATION | | | DATA.BUILDING VALUE HAS BEEN CHANGED | | | TO $233,750.ADDITIONAL PERMIT FEES | | | OF $676.20 AREW DUE BEFORE A PERMIT MAY | | | BE ISSUED. | | | | | | 3.WINDOW BUCKS SHALL COMPLY WITH | | | FBC 1707.4.4.2 BUCKS SHALL EXTEND | | | BEYOND THE INTERIOR FACE OF THE WINDOW | | | OR DOOR FRAME SUCH THAT FULL SUPPORT OF | | | THE FRAME IS PROVIDED. | | | SHOW ON DETAIL. | | | | | | 4.BALISTERS ON GUARD RAILS AND STAIR | | | RAILINGS SHALL BE SPACED THAT A 4" | | | DIAMETER SHERE CANNOT PASS THROUGH. | | | FBC 1015.3SHOW ON DETAIL. | | | | | | 5.SUBMIT A SECOND COPY OF ENERGY CALCS | | | | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-10 |
Time |
11:07 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-01-10 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-05-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-07 |
Time |
15:15 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-05-07 |
Time |
15:14 |
Sent To |
B |
|
| Notes |
| 2004-05-07 00:00:00 | PLANS SENT TO BLDG FOR PROCESSING. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-04 |
Time |
18:05 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-05-04 |
Time |
18:05 |
Sent To |
|
|
| Notes |
| 2004-05-04 00:00:00 | *********** RESPONSE ************** | | | | | | THIS IS IN RESPONSE FROM STUART BRENNER | | | DATED 4/28/04 | | | WE HAVE BEEN INSTRUCTED BY THE STATE | | | DBPR, FBPE'S THAT A LEGAL SIGNATURE | | | IS REQ'D AS PER FS 481.221, 471.025, | | | FAC 61G1-16.004, 61G15-23.002 | | | WE DO NOT HAVE THE AUTHORITY TO AUTHO- | | | -RIZE INITIALS AS AN ALTERNATIVE. | | | DBPR AND FBPE'S HAS MENTIONED, LEGAL | | | SIGNATURE MAY NOT BE ADJUSTED DUE TO | | | TIME IT MAY OR MAY NOT TAKE TO SIGN | | | PLANS. | | | ANY VARIATION IN LEAGAL SIGNATURE MUST | | | BE REVIEWED AND ACCEPTED BY DBPR/ BOARD | | | OF ARCHS. | | | | | | IF DESIRED, PLANS CAN BE SENT OFF FOR | | | VERIFICATION OF THIS. THIS WOULD UNFORT- | | | -UNATELY DELAY THE PERMIT FOR CONSTRUCT- | | | -ION. | | | WE ARE IN THE PROCESS OF HAVING FILES | | | AND LETTERS BEING SENT TO THE STATE FOR | | | REVIEW OF MANY OF THESE ITEMS, NOT ONLY | | | SIGNATURE ISSUES. | | | | | | PLEASE SUBMIT PLANS WITH ABOVE. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-03 |
Time |
10:25 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-04-28 |
Time |
06:07 |
Sent To |
B |
|
| Notes |
| 2004-04-28 00:00:00 | **** UNSAT *** | | | | | | 1)NOTE: PLEASE HAVE ARCH SIGN PLANS | | | WITH COMPLETE SIGNATURE AS SHOWN ON | | | LICENSE/RAISED SEAL ERP FS 481.221 | | | PLEASE SEE PLANS APPEAR TO SHOW INITIALS | | | OF SOME SORT? | | | PLEASE SUBMIT COPY OF LICENSE TO VERIFY | | | LEAGAL "SIGNATURE". THIS SHOULD BE A | | | DRIVER'S LICENSE/ ARCH LICENSE. | | | PER RECENT CONVERSATION WITH STATE, | | | A MIN OF FIRST AND LAST NAME IS REQ'D | | | OR AS SHOWN ON ARCH LICENSE. | | | THIS IS REQ'D FOR ALL TRADES AND ALL | | | SHEETS. FAC 61G1-16.004 | | | IF PLANS ONLY COME BACK FOR THIS COMMENT | | | ARESUB WILL NOT BE DUE,DUE TO LACK | | | OF COMMENT ON FIRST REVIEW BY INITIAL | | | REVIEWER. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-03-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-27 |
Time |
15:19 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-03-10 |
Time |
07:54 |
Sent To |
M |
|
| Notes |
| 2004-03-10 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CIRCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED, | | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | | | | 2} THE DOWNSTAIR BEDROOM LABLED #3 (SAME | | | AS UPSTAIR #3) NEEDS AN ADDED | | | RECEPTACLE PER 210.52(A)(1). | | | | | | 3} THE DISCONNECTS AT THE A/C UNITS DO | | | NOT COMPLY WITH 110.26 CLEARANCE | | | REQUIREMENTS. PLEASE INDICATE, ON THE | | | DRAWING, PLACEMENT FOR COMPLIANCE. | | | | | | 4} PLEASE SEE THE MECHANICAL PLANS TO | | | INSURE PLACEMENT OF THE SMOKE DETECTORS | | | IS IN COMPLIANCE WITH THE CLEARANCE | | | REQUIREMENTS OF NFPA-72, 1999 ED., CH | | | #8. | | | | | | 5} NOTE #15 REFERENCES THE 1997 SBC. | | | THIS PLAN IS BEING REVIEWED UNDER THE | | | 2001 FLORIDA BUILDING CODE. ALSO IT | | | SHOULD BE NOTED THAT SMOKE DETECTORS IN | | | BEDROOMS MUST COMPLY WITH 210.12 AND BE | | | ARC FAULT PROTECTED. | | | | | | 6} PLEASE INDICATE THE AMPERAGE RATING | | | OF THE FUSE OR BREAKER IN THE MAIN | | | DISCONNECT, ALSO THE AIC RATING OF SAME. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-07 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-07 |
Time |
14:29 |
Sent To |
E |
|
| Notes |
| 2005-01-07 00:00:00 | TO "BT" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-05-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-03 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-03 |
Time |
10:25 |
Sent To |
E |
|
| Notes |
| 2004-05-03 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-04-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-27 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-27 |
Time |
15:19 |
Sent To |
E |
|
| Notes |
| 2004-04-27 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-04-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-27 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-25 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2004-03-01 00:00:00 | TO SFD RACK/E | | 2004-02-25 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-03-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-10 |
Time |
10:37 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-03-10 |
Time |
15:19 |
Sent To |
P |
|
| Notes |
| 2004-03-10 00:00:00 | PROVISO: | | | PROVIDE CALCULATIONS FOR COMBUSTION AIR | | | IN THE LAUNDRY ROOM IN REFERENCE TO THE | | | GAS DRYER. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-03-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-10 |
Time |
15:30 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2004-03-13 |
Time |
09:45 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-02-27 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-27 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-02-27 |
Time |
12:45 |
Sent To |
I |
|
| Notes |
|
|