| Plan Review Stops For Permit 04021098 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-07-21 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-07-21 |
Time |
15:27 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2004-07-21 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2004-07-21 00:00:00 | REVISION OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-05-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-19 |
Time |
09:38 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2004-05-05 |
Time |
14:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-04-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-04 |
Time |
12:38 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2004-04-26 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-03-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-24 |
Time |
16:27 |
Rev Time |
2.50 |
| Received By |
alange |
Date |
2004-03-17 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2004-03-17 00:00:00 | DENIED | | | | | | 1.IMPACT PROTECTION REQUIRED ON ALL | | | OPENINGS. | | | | | | 2.PRODUCT APPROVALS FOR "CONSTRUCTION | | | GLASS INDUSTRIES" NOT LISTED ON THE | | | FBC PRODUCT APPROVAL SITE. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | | AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 3.2 COPIES OF ALL PRODUCT APPROVALS | | | REQUIRED. | | | | | | 4.NO PRODUCT APPROVALS SUBMITTED FOR | | | SINGE EXTERIOR DOORS. | | | | | | 5.VERIFY FINISH FLOOR ELEVATION OF | | | UTILITY ROOM IS A MINIMUM 4" ABOVE | | | FINISH GRADE WPB AMMENDMENTS 1804.17 | | | | | | 6. SECTION 5/A7 USP-AD52 ANCHOR IS NOT | | | AVALID USP ANCHOR. | | | | | | 7.WINDOW #9 SHALL COMPLY WITH SECTION | | | FBC 2405.2.1 SAFTEY GLAZING. | | | | | | 8.SHOW ATTIC ACCESS COMPLYING WITH | | | FBC 2309.6 20 X 36" OPENING | | | | | | 9.FIRST AND SECOND FLOOR SLEEPING ROOM | | | EGRESS WINDOWS SHALL COMPLY WITH | | | FBC 1005.4SUBMIT A WINDOW SHEDULE | | | FOR SECOND FLOOR SHOWING SLEEPING ROOMS. | | | | | | 10.PROJECT VALUATION TOO LOW. BASED | | | UPON SBCCI BUILDING VALUATION DATA | | | THE ROOM ADDITION ALONE WILL BE | | | $143,992 PLUS THE ADDITION WORK ON THE | | | EXISTING BUILDING.SUBMIT AN ACCURATE | | | REVISED PROJECT VALUE. | | | | | | PLEASE ADDRESS THE ABOVE COMMENTS | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2004-10-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-05 |
Time |
19:51 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-10-05 |
Time |
19:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2004-09-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-05 |
Time |
10:52 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-09-22 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2004-09-22 00:00:00 | ******* UNSAT ********** | | | | | | 1)NOTE: PLEASE SEE REVISED RISER DIAGRAM | | | , MAINS ARE NOT GROUPED AS REQUIRED | | | UNDER 230.72. SHOWS A MCB INSIDE AND | | | A MAIN DISC OUTSIDE FOR THE OTHER. | | | | | | 2 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | PLEASE SEE TOTAL # OF RECESSED LTS. | | | | | | 3)NOTE: LT REQUIRED IN DINING ROOM. | | | 210.70 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-17 |
Time |
09:09 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-05-04 |
Time |
12:29 |
Sent To |
B |
|
| Notes |
| 2004-05-04 00:00:00 | ******* PLANS REDLINED **** | | | | | | 1)NOTE: PLEASE SEE NOW SOME OF THE EXIST | | | -ING LAYOUT IS SHOWN. | | | PLEASE SEE ALL EXISTING ELECTRICAL MUST | | | BE BROUGHT UP TO CODE. | | | NO MEANS OF EGRESS LIGHTING OR CONTROL | | | IS SHOWN FOR EXISTING STAIRWAY.210.70 | | | NO CONTROL FOR MEANS OF EGRESS TO OUT- | | | -SIDE. 210.70 | | | | | | 2)NOTE: PLEASE SEE 210.52E FOR REQ'D | | | OUTSIDE RECEPT. | | | | | | 3)NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | | UNIT. | | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | | TO FLOORS ABOVE AND IN THE VICINITY OF | | | BEDROOMS. | | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | | A MIN OF 3' FROM BATHROOM DOORS AND | | | KITCHENS. | | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4 | | | PLEASE SEE MISSING SD ON FIRST FLR | | | LEADING TO THE FLR ABOVE. | | | | | | OWES 2ND RESUB FEE. SEE BZ ATTACHED. | | | SOME NOTES WERE FROM FIRST REVIEW ALSO. | | | | | | ALL REVISIONS TO BE SUBMITTED BEFORE | | | ROUGH. | | | | | | IF THERE ARE ANY QUESTIONS,PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-04-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-30 |
Time |
16:13 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-04-20 |
Time |
06:03 |
Sent To |
P |
|
| Notes |
| 2004-04-20 00:00:00 | ************* UNSAT ************ | | | | | | PLEASE SEE SOME NOTES FROM THE FIRST | | | REVIEW STILL NEED TO BE ADDRESSED. | | | | | | 1)NOTE: PLEASE SEE 250.66 FOR SIZING | | | OF GEC. MIN #2. | | | | | | 2)NOTE: PLEASE SEE SD NOTE, IT HAS NOW | | | BEEN CHANGED TO REFLECTA AND NOTE AFCI | | | PROTECTION FOR RECEPTS AND LTS. PLEASE | | | SEE 210.12 OF THE 2002 NEC. AFCI IS | | | REQ'D FOR ALL "OUTLETS". THIS WOULD | | | INCLUDE SD'S. | | | | | | NEW COMMENTS. | | | | | | 3)NOTE: PLANS SHOW ONE PANEL BEING | | | INSTALLED IN LAUNDRY RM AND THE OTHER | | | IS NOT SHOWN? | | | PLEASE SEE 230.72 FOR GROUPING OF MAINS, | | | RISER SHOWS 2-150A MCB PANELS? | | | THERE MAY NOT BE MORETHAN 8' OF UNPRO- | | | -TECTED CONDUCTORS INSIDE THE BLDG. | | | 230.70 LOCAL AMENDMENTS. IF SO, MAINS | | | ARE REQ'D W/ OCP OUTSIDE. | | | | | | 4)NOTE: PLEASE SHOW A LAYOUT OF EXSITNG | | | DWELLING RMS SHOWING EITHER EXISTING | | | MEETING CODE COMPLIANCE OR NEW TO BE | | | INSTALLED. PLEASE SEE FBC CHAPTER 34 | | | 3401.7.1.1 PLEASE SEE THAT THE ENTIRE | | | EXISITNG DWELLING WOULD NEED TO BE | | | BROUGHT UP TO CODE FOR ELECTRICAL. | | | PLEASE SEE OTHER REVIEWS. | | | | | | 5)NOTE: THIS IS ONLY A NOTE AND MUST BE | | | GIVEN ON ANY REVIEWS WITH COMMENTS ON | | | SECOND REVIEW WHERE ANY COMMENTS FROM | | | FIRST REVIEW WERE NOT ADDRESSED. | | | PLEASE SEE COPY OF ATTACHED SHEET FOR | | | FS 553.80(2)(B). THIS IS ONLY A NOTE | | | AND NOTICE MUST BE GIVEN AT THIS TIME. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-03-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-19 |
Time |
12:39 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-03-04 |
Time |
13:44 |
Sent To |
P |
|
| Notes |
| 2004-03-05 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE GROUNDING ELECTRODE CONDUCTOR IS | | | INCORRECT PER 250.66, SHOULD BE A | | | MINIMUM OF #2 CU. | | | | | | 2} THE SMALL APPLIANCE CALCULATION ON | | | THE PANEL SCHEDULE IS NOT IN COMPLIANCE | | | WITH 220.16(A), 1500 VA PER CIRCUIT. | | | | | | 3} THERE IS NO LAUNDRY CIRCUIT IN THE | | | CALCULATION. SEE 220.16(B). | | | | | | 4} PLEASE LIST ALL THE REQUIRED | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE PER 210.11(C)(3). | | | | | | 5} THE NOTE REGARDING ARC FAULT | | | PROTECTION SHOULD INCLUDE ALL OUTLETS | | | IN THE BEDROOM, NOT JUST RECEPTACLES. | | | SEE 210.12. | | | | | | 6} SERVICE RECEPTACLES ARE REQUIRED TO | | | COMPLY WITH 210.63.(A/C UNITS). | | | | | | 7} A RECEPTACLE IS REQUIRED ON THE REAR | | | OF THE ADDITION TO COMPLY WITH 210.52(E) | | | | | | 8} THE RECEPTACLE IN THE LAUNDRY AT THE | | | SINK MUST BE GFI PROTECTED PER 210.8. | | | | | | 9} THE SMOKE DETECTOR IN THE KITCHEN | | | MUST COMPLY WITH 8-1.4.2 NFPA-72. | | | | | | 10} THE OUTLET SUPPLYING THE WHIRLPOOL | | | MUST COMPLY WITH 680.71.(GFI). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-10-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-05 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-05 |
Time |
10:52 |
Sent To |
E |
|
| Notes |
| 2004-10-05 00:00:00 | TO DP DESK/REV/AS BUILTS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-09-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-17 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-17 |
Time |
09:09 |
Sent To |
E |
|
| Notes |
| 2004-09-17 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-08-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-26 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-26 |
Time |
13:23 |
Sent To |
M |
|
| Notes |
| 2004-08-26 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-07-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-19 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-19 |
Time |
09:38 |
Sent To |
B |
|
| Notes |
| 2004-07-19 00:00:00 | TO AL DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-04-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-30 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-30 |
Time |
16:13 |
Sent To |
E |
|
| Notes |
| 2004-04-30 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-04-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-14 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-14 |
Time |
10:39 |
Sent To |
M |
|
| Notes |
| 2004-04-14 00:00:00 | TO PK BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-03-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-02 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-02 |
Time |
08:34 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-02-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-03-01 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-25 |
Time |
13:44 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-09-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-09-16 |
Time |
10:38 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-09-16 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-04-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-26 |
Time |
13:23 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-04-19 |
Time |
12:20 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-03-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-14 |
Time |
10:39 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2004-03-10 |
Time |
09:00 |
Sent To |
B |
|
| Notes |
| 2004-03-10 00:00:00 | DENIED: | | | PLEASE PROVIDE THE FOLLOWING INFORMATION | | | 1.RETURN AIR - PLAN INDICATES A RETURN | | | AIR GRILLE IN THE HALLWAY BETWEEN HIS | | | WALK-IN CLOSET AND THE SITTING ROOM, | | | INDICATE IF THERE WILL BE A PLENUM BACK | | | TO THE AHU.INDICATE HOW RETURN WILL | | | BE TRANSFERED BACK TO THE UNIT.PROVIDE | | | DUCT & GRILLE SIZES.SHOW COMPLIANCE | | | WITH 2001 FBC(M) 601.4 (REV. EFFECTIVE | | | JUNE 30, 2003). | | | | | | 2.PLEASE CLARIFY IF THE A/C EQUIPMENT | | | LISTED ON PLAN IS TO SERVE THE ADDITION | | | ONLY OR WILL IT ALSO SERVE ANY EXISTING | | | AREA. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-04-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-24 |
Time |
16:27 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-04-24 |
Time |
16:27 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-20 |
Time |
06:18 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-03-09 |
Time |
12:41 |
Sent To |
M |
|
| Notes |
| 2004-03-09 00:00:00 | DENIED | | | REFERENCE: FLORIDA STATUTES | | | FLORIDA ADMIN. CODE | | | | | | SIGNATURE ON SEAL DOES NOT MATCH SIGNA- | | | TURE RECORDED AS THAT OF ARCHITECT. | | | ONE SET OF PLANS SHALL BE RETAINED ON | | | FILE FOR REVIEW BY STATE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|