Plan Review Details - Permit 04021098
Plan Review Stops For Permit 04021098
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-07-21 Cont ID  
Sent By alange Date 2004-07-21 Time 15:27 Rev Time 0.66
Received By alange Date 2004-07-21 Time 15:27 Sent To  
Notes
2004-07-21 00:00:00REVISION OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-05-05 Cont ID  
Sent By csiegber Date 2004-07-19 Time 09:38 Rev Time 1.00
Received By alange Date 2004-05-05 Time 14:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-04-26 Cont ID  
Sent By dpalmer Date 2004-05-04 Time 12:38 Rev Time 0.75
Received By alange Date 2004-04-26 Time 09:23 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-03-17 Cont ID  
Sent By kstevens Date 2004-04-24 Time 16:27 Rev Time 2.50
Received By alange Date 2004-03-17 Time 14:45 Sent To  
Notes
2004-03-17 00:00:00DENIED
  
 1.IMPACT PROTECTION REQUIRED ON ALL
 OPENINGS.
  
 2.PRODUCT APPROVALS FOR "CONSTRUCTION
 GLASS INDUSTRIES" NOT LISTED ON THE
 FBC PRODUCT APPROVAL SITE.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATIONPLEASE SEE THE STATE WEBSITE
 AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 3.2 COPIES OF ALL PRODUCT APPROVALS
 REQUIRED.
  
 4.NO PRODUCT APPROVALS SUBMITTED FOR
 SINGE EXTERIOR DOORS.
  
 5.VERIFY FINISH FLOOR ELEVATION OF
 UTILITY ROOM IS A MINIMUM 4" ABOVE
 FINISH GRADE WPB AMMENDMENTS 1804.17
  
 6. SECTION 5/A7 USP-AD52 ANCHOR IS NOT
 AVALID USP ANCHOR.
  
 7.WINDOW #9 SHALL COMPLY WITH SECTION
 FBC 2405.2.1 SAFTEY GLAZING.
  
 8.SHOW ATTIC ACCESS COMPLYING WITH
 FBC 2309.6 20 X 36" OPENING
  
 9.FIRST AND SECOND FLOOR SLEEPING ROOM
 EGRESS WINDOWS SHALL COMPLY WITH
 FBC 1005.4SUBMIT A WINDOW SHEDULE
 FOR SECOND FLOOR SHOWING SLEEPING ROOMS.
  
 10.PROJECT VALUATION TOO LOW. BASED
 UPON SBCCI BUILDING VALUATION DATA
 THE ROOM ADDITION ALONE WILL BE
 $143,992 PLUS THE ADDITION WORK ON THE
 EXISTING BUILDING.SUBMIT AN ACCURATE
 REVISED PROJECT VALUE.
  
 PLEASE ADDRESS THE ABOVE COMMENTS
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2004-10-05 Cont ID  
Sent By dpalmer Date 2004-10-05 Time 19:51 Rev Time 0.25
Received By dpalmer Date 2004-10-05 Time 19:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2004-09-22 Cont ID  
Sent By csiegber Date 2004-10-05 Time 10:52 Rev Time 0.50
Received By dpalmer Date 2004-09-22 Time 16:53 Sent To  
Notes
2004-09-22 00:00:00******* UNSAT **********
  
 1)NOTE: PLEASE SEE REVISED RISER DIAGRAM
 , MAINS ARE NOT GROUPED AS REQUIRED
 UNDER 230.72. SHOWS A MCB INSIDE AND
 A MAIN DISC OUTSIDE FOR THE OTHER.
  
 2 )NOTE: PLEASE SEE 220.3B4.
 PLEASE SHOW ALL RECESSED LTS BASED ON
 MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT
 BE FIGURED IN W/ 3W/PER SQ FT.
 PLEASE PROVIDE FIXTURE INFORMATION ON
 LEGEND.
 PLEASE SEE TOTAL # OF RECESSED LTS.
  
 3)NOTE: LT REQUIRED IN DINING ROOM.
 210.70
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-05-04 Cont ID  
Sent By csiegber Date 2004-09-17 Time 09:09 Rev Time 0.75
Received By dpalmer Date 2004-05-04 Time 12:29 Sent To B
Notes
2004-05-04 00:00:00******* PLANS REDLINED ****
  
 1)NOTE: PLEASE SEE NOW SOME OF THE EXIST
 -ING LAYOUT IS SHOWN.
 PLEASE SEE ALL EXISTING ELECTRICAL MUST
 BE BROUGHT UP TO CODE.
 NO MEANS OF EGRESS LIGHTING OR CONTROL
 IS SHOWN FOR EXISTING STAIRWAY.210.70
 NO CONTROL FOR MEANS OF EGRESS TO OUT-
 -SIDE. 210.70
  
 2)NOTE: PLEASE SEE 210.52E FOR REQ'D
 OUTSIDE RECEPT.
  
 3)NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ON EACH LEVEL OF A MULTI-LEVEL DWELLING
 UNIT.
 IN CLOSE PROXIMITY OF STAIRWAYS LEADING
 TO FLOORS ABOVE AND IN THE VICINITY OF
 BEDROOMS.
 PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE
 A MIN OF 3' FROM BATHROOM DOORS AND
 KITCHENS.
 ABOVE PER:FBC 905.2, NFPA-72 8-1.4
 PLEASE SEE MISSING SD ON FIRST FLR
 LEADING TO THE FLR ABOVE.
  
 OWES 2ND RESUB FEE. SEE BZ ATTACHED.
 SOME NOTES WERE FROM FIRST REVIEW ALSO.
  
 ALL REVISIONS TO BE SUBMITTED BEFORE
 ROUGH.
  
 IF THERE ARE ANY QUESTIONS,PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-04-20 Cont ID  
Sent By csiegber Date 2004-04-30 Time 16:13 Rev Time 0.33
Received By dpalmer Date 2004-04-20 Time 06:03 Sent To P
Notes
2004-04-20 00:00:00************* UNSAT ************
  
 PLEASE SEE SOME NOTES FROM THE FIRST
 REVIEW STILL NEED TO BE ADDRESSED.
  
 1)NOTE: PLEASE SEE 250.66 FOR SIZING
 OF GEC. MIN #2.
  
 2)NOTE: PLEASE SEE SD NOTE, IT HAS NOW
 BEEN CHANGED TO REFLECTA AND NOTE AFCI
 PROTECTION FOR RECEPTS AND LTS. PLEASE
 SEE 210.12 OF THE 2002 NEC. AFCI IS
 REQ'D FOR ALL "OUTLETS". THIS WOULD
 INCLUDE SD'S.
  
 NEW COMMENTS.
  
 3)NOTE: PLANS SHOW ONE PANEL BEING
 INSTALLED IN LAUNDRY RM AND THE OTHER
 IS NOT SHOWN?
 PLEASE SEE 230.72 FOR GROUPING OF MAINS,
 RISER SHOWS 2-150A MCB PANELS?
 THERE MAY NOT BE MORETHAN 8' OF UNPRO-
 -TECTED CONDUCTORS INSIDE THE BLDG.
 230.70 LOCAL AMENDMENTS. IF SO, MAINS
 ARE REQ'D W/ OCP OUTSIDE.
  
 4)NOTE: PLEASE SHOW A LAYOUT OF EXSITNG
 DWELLING RMS SHOWING EITHER EXISTING
 MEETING CODE COMPLIANCE OR NEW TO BE
 INSTALLED. PLEASE SEE FBC CHAPTER 34
 3401.7.1.1 PLEASE SEE THAT THE ENTIRE
 EXISITNG DWELLING WOULD NEED TO BE
 BROUGHT UP TO CODE FOR ELECTRICAL.
 PLEASE SEE OTHER REVIEWS.
  
 5)NOTE: THIS IS ONLY A NOTE AND MUST BE
 GIVEN ON ANY REVIEWS WITH COMMENTS ON
 SECOND REVIEW WHERE ANY COMMENTS FROM
 FIRST REVIEW WERE NOT ADDRESSED.
 PLEASE SEE COPY OF ATTACHED SHEET FOR
 FS 553.80(2)(B). THIS IS ONLY A NOTE
 AND NOTICE MUST BE GIVEN AT THIS TIME.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-03-05 Cont ID  
Sent By pkrauss Date 2004-04-19 Time 12:39 Rev Time 0.50
Received By btrobaug Date 2004-03-04 Time 13:44 Sent To P
Notes
2004-03-05 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE GROUNDING ELECTRODE CONDUCTOR IS
 INCORRECT PER 250.66, SHOULD BE A
 MINIMUM OF #2 CU.
  
 2} THE SMALL APPLIANCE CALCULATION ON
 THE PANEL SCHEDULE IS NOT IN COMPLIANCE
 WITH 220.16(A), 1500 VA PER CIRCUIT.
  
 3} THERE IS NO LAUNDRY CIRCUIT IN THE
 CALCULATION. SEE 220.16(B).
  
 4} PLEASE LIST ALL THE REQUIRED
 DEDICATED BATH(S) CIRCUIT(S) ON PANEL
 SCHEDULE PER 210.11(C)(3).
  
 5} THE NOTE REGARDING ARC FAULT
 PROTECTION SHOULD INCLUDE ALL OUTLETS
 IN THE BEDROOM, NOT JUST RECEPTACLES.
 SEE 210.12.
  
 6} SERVICE RECEPTACLES ARE REQUIRED TO
 COMPLY WITH 210.63.(A/C UNITS).
  
 7} A RECEPTACLE IS REQUIRED ON THE REAR
 OF THE ADDITION TO COMPLY WITH 210.52(E)
  
 8} THE RECEPTACLE IN THE LAUNDRY AT THE
 SINK MUST BE GFI PROTECTED PER 210.8.
  
 9} THE SMOKE DETECTOR IN THE KITCHEN
 MUST COMPLY WITH 8-1.4.2 NFPA-72.
  
 10} THE OUTLET SUPPLYING THE WHIRLPOOL
 MUST COMPLY WITH 680.71.(GFI).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2004-10-05 Cont ID  
Sent By csiegber Date 2004-10-05 Time 10:52 Rev Time 0.00
Received By csiegber Date 2004-10-05 Time 10:52 Sent To E
Notes
2004-10-05 00:00:00TO DP DESK/REV/AS BUILTS

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2004-09-17 Cont ID  
Sent By csiegber Date 2004-09-17 Time 09:09 Rev Time 0.00
Received By csiegber Date 2004-09-17 Time 09:09 Sent To E
Notes
2004-09-17 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-08-26 Cont ID  
Sent By csiegber Date 2004-08-26 Time 13:23 Rev Time 0.00
Received By csiegber Date 2004-08-26 Time 13:23 Sent To M
Notes
2004-08-26 00:00:00TO PK BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-07-19 Cont ID  
Sent By csiegber Date 2004-07-19 Time 09:38 Rev Time 0.00
Received By csiegber Date 2004-07-19 Time 09:38 Sent To B
Notes
2004-07-19 00:00:00TO AL DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-04-30 Cont ID  
Sent By csiegber Date 2004-04-30 Time 16:13 Rev Time 0.00
Received By csiegber Date 2004-04-30 Time 16:13 Sent To E
Notes
2004-04-30 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-04-14 Cont ID  
Sent By csiegber Date 2004-04-14 Time 10:39 Rev Time 0.00
Received By csiegber Date 2004-04-14 Time 10:39 Sent To M
Notes
2004-04-14 00:00:00TO PK BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-02 Cont ID  
Sent By csiegber Date 2004-03-02 Time 08:34 Rev Time 0.00
Received By csiegber Date 2004-03-02 Time 08:34 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-25 Cont ID  
Sent By mmclean Date 2004-03-01 Time 16:50 Rev Time 0.00
Received By csiegber Date 2004-02-25 Time 13:44 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2004-09-16 Cont ID  
Sent By pkrauss Date 2004-09-16 Time 10:38 Rev Time 0.30
Received By pkrauss Date 2004-09-16 Time 09:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-04-19 Cont ID  
Sent By csiegber Date 2004-08-26 Time 13:23 Rev Time 0.30
Received By pkrauss Date 2004-04-19 Time 12:20 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-03-10 Cont ID  
Sent By csiegber Date 2004-04-14 Time 10:39 Rev Time 0.33
Received By pkrauss Date 2004-03-10 Time 09:00 Sent To B
Notes
2004-03-10 00:00:00DENIED:
 PLEASE PROVIDE THE FOLLOWING INFORMATION
 1.RETURN AIR - PLAN INDICATES A RETURN
 AIR GRILLE IN THE HALLWAY BETWEEN HIS
 WALK-IN CLOSET AND THE SITTING ROOM,
 INDICATE IF THERE WILL BE A PLENUM BACK
 TO THE AHU.INDICATE HOW RETURN WILL
 BE TRANSFERED BACK TO THE UNIT.PROVIDE
 DUCT & GRILLE SIZES.SHOW COMPLIANCE
 WITH 2001 FBC(M) 601.4 (REV. EFFECTIVE
 JUNE 30, 2003).
  
 2.PLEASE CLARIFY IF THE A/C EQUIPMENT
 LISTED ON PLAN IS TO SERVE THE ADDITION
 ONLY OR WILL IT ALSO SERVE ANY EXISTING
 AREA.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-04-24 Cont ID  
Sent By kstevens Date 2004-04-24 Time 16:27 Rev Time 0.50
Received By kstevens Date 2004-04-24 Time 16:27 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-03-09 Cont ID  
Sent By dpalmer Date 2004-04-20 Time 06:18 Rev Time 0.50
Received By kstevens Date 2004-03-09 Time 12:41 Sent To M
Notes
2004-03-09 00:00:00DENIED
 REFERENCE: FLORIDA STATUTES
 FLORIDA ADMIN. CODE
  
 SIGNATURE ON SEAL DOES NOT MATCH SIGNA-
 TURE RECORDED AS THAT OF ARCHITECT.
 ONE SET OF PLANS SHALL BE RETAINED ON
 FILE FOR REVIEW BY STATE.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-03-01 Cont ID  
Sent By csiegber Date 2004-02-25 Time 13:44 Rev Time 0.00
Received By mmclean Date 2004-03-01 Time 16:49 Sent To I
Notes
***NONE***