| Plan Review Stops For Permit 04021074 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-05-12 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-05-12 |
Time |
12:58 |
Rev Time |
1.33 |
| Received By |
alange |
Date |
2004-05-12 |
Time |
12:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-04-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-27 |
Time |
15:20 |
Rev Time |
2.50 |
| Received By |
alange |
Date |
2004-04-06 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2004-04-06 00:00:00 | DENIED | | | 1.PRODUCT APPROVAL FOR ENTRY DOOR | | | MISSING.SUBMIT 2 COPIES. | | | APPLICATIONS FOR LOCAL AND OR STATE | | | SITE SPECIFIC PRODUCT APPROVAL NOT | | | REQUIRED IF PRODUCT IS LISTED ON THE | | | FBC PRODUCT APPROVAL SITE.ALL | | | PRODUCTSSUBMITTED ARE ON THE FBC SITE. | | | PLEASE REMOVE APPLICATIONS. | | | | | | 2.VALUATION OF $166,800 IS TO LOW | | | BASED UPON SBCCI BUILDING VALUATION | | | DATA. BUILDING VALUE HAS BEEN CHANGED | | | TO $233,750ADDITION PERMIT FEES OF | | | $676.20 ARE DUE BEFORE A PERMIT MAY BE | | | ISSUED. | | | | | | 3. WINDOW BUCKS SHALL COMPLY WITH | | | FBC 1707.4.4.2BUCKS SHALL EXTEND | | | BEYOND THE INTERIOR OR FACE OF THE | | | WINDOW OR DOOR FRAME SUCH THAT FULL | | | SUPPORT OF THE FRAME IS PROVIDED. | | | SHOW ON DETAIL. | | | | | | 4.BALISTERS ON GUARD RAILS AND STAIR | | | RAILINGS SHALL BE SPACED THAT A 4" | | | DIAMETER SPHERE CANNOT PAS THROUGH. | | | FBC 1015.3PLEASE REVISE DETAIL. | | | | | | 5.SUBMIT A SECOND COPY OF ENERY CALC'S | | | | | | | | | ANY QUESTIONS CONTACT ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-01-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-19 |
Time |
09:59 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-01-19 |
Time |
07:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-12-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-12-10 |
Time |
14:51 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-12-10 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-03-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-16 |
Time |
07:12 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-03-16 |
Time |
06:22 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-01-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-14 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-14 |
Time |
09:10 |
Sent To |
E |
|
| Notes |
| 2005-01-14 00:00:00 | TO "BT" DESK"/AS BUILTS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-12-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-06 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-06 |
Time |
07:51 |
Sent To |
E |
|
| Notes |
| 2004-12-06 00:00:00 | SENT T "BT" DESK./ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-04-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-27 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-27 |
Time |
15:20 |
Sent To |
B |
|
| Notes |
| 2004-04-27 00:00:00 | TO RM DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-04-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-27 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-26 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2004-03-01 00:00:00 | TO SFD RACK/E | | 2004-02-26 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-03-20 |
Time |
08:52 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2004-03-22 |
Time |
09:12 |
Sent To |
B |
|
| Notes |
| 2004-03-22 00:00:00 | PROVISO: | | | 1.AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 FBC 307.2.3 | | | | | | 2.PLAN INDICATES WALL MOUNT FOR THE | | | AHU.PER 2001 FBC(M) 603.1.3, A | | | MINIMUM OF 4" CLEARANCE AROUND THE AHU | | | IS REQUIRED FOR SEALING, INSPECTION, | | | CLEANING & MAINTENANCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-03-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-03-20 |
Time |
08:52 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-03-20 |
Time |
08:52 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-02-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-27 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-02-25 |
Time |
12:23 |
Sent To |
I |
|
| Notes |
|
|