| Plan Review Stops For Permit 04021070 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2004-06-29 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-06-29 |
Time |
13:28 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2004-06-29 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2004-06-29 00:00:00 | DENIED | | | SEE TABLE 600 FBC NO OPENINGS PERMITTED | | | FOR ZERO LOT SIDE.UNDER 3 FT. FROM | | | PROPERTY LINE. | | | | | | SUBMIT PRODUCT APPROVAL. | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
12:51 |
Rev Time |
0.25 |
| Received By |
alange |
Date |
2004-06-17 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2004-06-17 00:00:00 | REVISION OK ONLY |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-05-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-11 |
Time |
10:49 |
Rev Time |
2.00 |
| Received By |
lsmith |
Date |
2004-05-18 |
Time |
07:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2004-05-17 |
Time |
17:08 |
Rev Time |
2.50 |
| Received By |
lsmith |
Date |
2004-05-04 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2004-05-04 00:00:00 | BUILDING PLAN REVIEW FAILED: | | | | | | 1. IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | A COPY OF THE PAID RECEIIPT SUBMITTED | | | TO THE CITY BEFORE A PERMIT CAN BE | | | ISSUED. | | | | | | 2. A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3. SUBMIT A SIGNED & SEALED COPY OF THE | | | SOIL REPORT INCLUDING THE BORING LOG. | | | | | | 4. HIGHLIGHT THE GLASS BLOCK BEING USED | | | TO SHOW THICKNESS AND FIRE RATING. | | | | | | 5.PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | | AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | SUBMIT STATE PRODUCT APPROVALS AS | | | REQUESTED IN FIRST REVIEW NOTES. | | | | | | 6. BUTT GLASS SUBMITTALS STILL INCLUDED | | | BUT NO BUTT GLASS SHOWN ON PLANS. | | | | | | 7. SUBMIT MANUFACTURER'S SPECIFICATIONS | | | ON GAS HOOD FOR BBQ. | | | | | | 8. SUBMIT A SURVEY WITH THE PROPOSED | | | HOUSE SHOWN AND FLOOD ZONE. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-04-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-03-13 |
Time |
07:13 |
Rev Time |
3.00 |
| Received By |
lsmith |
Date |
2004-04-01 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2004-04-01 00:00:00 | BUILDING PLAN REVIEW FAILED: | | | | | | 1. IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | A COPY OF THE PAID RECEIPT SUBMITTED TO | | | THE CITY BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2. A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3. SUBMIT A SIGNED & SEALED COPY OF THE | | | SOIL REPORT INCLUDING THE BORING LOG. | | | | | | 4. THE GLASS BLOCK IN THE EXTERIORWALL | | | THAT IS WITHIN 3 FEET OF THE PROPERTY | | | LINE IS REQUIRED TOHAVE | | | A ONE HOUR FIRE RATING PER FBC TABLE | | | 600. SPECIFY ON PLANS. | | | | | | 5. THE GLASS BLOCK AT THE TUBS IN THE | | | MASTER BATH & BATH #2 IS REQUIRED TO | | | HAVE A MINIMUM UNIFORM FACE THICKNESS | | | OF 0.25. SEE FBC 2405.2.2 (5) | | | | | | 6. THE WINDOW IN BATH #3 IS WITHIN 3' | | | OF SHOWER IS REQUIRED TO HAVE SAFETY | | | GLAZING PER 2405.2. | | | | | | 7.PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE | | | ATWWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | SUBMIT STATE OR LOCAL PRODUCT APPROVALS | | | FOR THE FOLLOWING: | | | ROOF TILE | | | DOUBLE INSWING ENTRY DOORS | | | DOUBLE OUTSWING GLAZED DOORS WITH AND | | | WITHOUT SIDELIGHTS. | | | SINGLE OUTSWING PANEL DOORS | | | SINGLE HUNG WINDOWS | | | FIXED GLASS WINDOWS (CIRCULAR, ARCHED, | | | ETC. | | | GLASS BLOCK ( FIRE RATED) | | | STRUCTURAL MULLIONS | | | OVERHEAD GARAGE DOORS | | | STORM PANELS | | | TRUSS ANCHORS & CONNECTORS. | | | | | | 8. SUBMIT MANUFACTURER'S INSTALLATION | | | SPECIFICATIONS AND LISTING FOR ONE HOUR | | | GLASS BLOCK ASSEMBLY. | | | | | | 9. SUBMIT A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS.SPECIFY | | | THE MOUNT TYPE, ANCHOR TYPE AND SPACING | | | ON THE INSTALLATION DRAWINGS. | | | | | | 10. 2 DIFFERENT PRODUCT APPROVALS (DADE | | | COUNTY) WERE SUBMITTED FOR THE ROOF. | | | PLEASE REMOVE ONE. A SEPARATE | | | PERMIT WILL BE REQUIRED FOR THE ROOF. | | | | | | 11. SUBMITTALS FOR BUTT GLASS WAS | | | SUBMITTED.PLANS DO NOT SHOW ANY BUTT | | | GLASS WINDOWS IN THIS HOUSE. | | | | | | 12. SUBMIT 2 COPIES OF THE | | | MANUFACTURER'S SPECIFICATIONS AND UL | | | LISTING FOR THE GAS BBQ AND HOOD.A | | | SEPARATE GAS PERMIT WILL BE REQUIRED. | | | | | | 13. KITCHEN WINDOW DIMENSIONS NOT SHOWN | | | ON PLANS. (ONLY TRANSOM SHOWN) | | | | | | 14. THE FBC TABLE 600 CALCULATIONS FOR | | | THE EXTERIOR WALL AT THE DINING ROOM AND | | | DEN/STUDY ARE INCORRECT. ONLY 20% OF | | | THE WALL AREA IS ALLOWED AS OPENINGS. | | | PLEASE CORRECT. | | | | | | 15. SPECIFY THE FOOTING DETAIL FOR THE | | | 5' WALL IN THE GARDEN COURT. | | | | | | 16. THE STATEDVALUE OF THE HOUSE IS | | | UNDERSTATED.VALUE HAS BEEN ADJUSTED | | | TO $290,601. PER SBCCI BUILDING | | | VALUATION DATA. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-02-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-23 |
Time |
10:24 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-02-23 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2005-02-23 00:00:00 | REDLINED CONDUCTORS FOR SUB PANEL. | | | REDLINED 2-P BRKR INSTEAD OF 1-P SHOWN. | | | STAMPED OK FOR PARTIAL FINAL. | | | NEED TO BRING IN REPRINTED CORRECTED | | | SHEET BEFORE CO. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-02-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-17 |
Time |
07:18 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-02-17 |
Time |
07:07 |
Sent To |
|
|
| Notes |
| 2005-02-17 00:00:00 | *********UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE RISER INDICATES BOTH | | | PANELS AS MLO AND NO MAIN IS SHOWN? | | | PLEASE SEE PLANS SHOWS A SEPARATE MAIN? | | | PLEASE CORRELATE. MAIN REQUIRED | | | 225.31,225.32,240.4 ETC | | | | | | 2)NOTE: PLEASE SEE RISER SHOWS SUB PANEL | | | AS 60A'S YET PANEL SHOWS @ 100A'S. | | | PLEASE ALSO SEE PANEL "A" SHOWS A SINGLE | | | POLE 15A BRKR FEEDING PANEL "B". | | | PLEASE ALSO SEE RISER INDICATES A 100A | | | BRKR FEEDING THE 60A PANEL? | | | PLEASE ADJUST. | | | | | | 3)NOTE: PLEASE PANEL"A" INDICATES FOUR | | | 10KW AHU'S. NO COND UNITS SHOWN? | | | PLEASE VERIFY AND CORRECT. | | | | | | 4)NOTE: PLEASE SEE GFI RECEPT SPACING IN | | | KITCHEN TO BE PER 210.52C1. MISSING ON | | | MORE THAN ONE COUNTERSPACE. | | | | | | 5)NOTE: PLEASE SEE 210.52D FOR GFI | | | RECEPTS TO BE W/IN 3' OF BATH RM SINKS | | | EDGE. | | | | | | 6)NOTE: PLEASE SEE PLANS DO NOT INDICATE | | | LOACTION OF PANEL "B". | | | | | | 7 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | 8)NOTE: PLEASE SEE MISSING HALLWAY | | | RECEPT PER 210.52H | | | | | | 9)NOTE: PLEASE SEE GROUNDING ELECTRODE | | | SYSTEM TO INCLUDE FOOTER STEEL PER | | | 250.50. | | | | | | ** PLEASE SEE ONE COPY OF PLANS ARE | | | BEING RETAINED. PLEASE SEE OTHER COPY | | | HAS MOST OF THESE ITEMS REDLINED AT | | | LOCATIONS FOR ABOVE NOTES. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-05-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-13 |
Time |
07:41 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-05-13 |
Time |
07:41 |
Sent To |
M |
|
| Notes |
| 2004-05-13 00:00:00 | *** NOTED *** | | | 220.3B4 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-04-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-12 |
Time |
16:57 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-04-23 |
Time |
20:32 |
Sent To |
P |
|
| Notes |
| 2004-04-23 00:00:00 | ************** UNSAT 2ND TIME ********* | | | | | | PLEASE SEE MOST COMMENTS FROM FIRST | | | REVIEW HAVE NOT BEEN ADRESSED FOR CODE | | | COMPLIANCE. | | | | | | 1) NOTE: PLEASE SHOW ALL RECEPTS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | | -ED PER 210.8A-6 | | | | | | 2 ) NOTE: PLEASE SEE MISSING RECEPTS FOR | | | FRONT AND/OR REAR OF DWELLING. | | | 210.52E PLANS SHOW TWO SEPARATE GFI | | | RECEPTS FOR A/C COND UNITS?? | | | MISSING FRONT OF DWELLING. | | | | | | 3 )NOTE: PLEASE SEE RECEPTS SERVING | | | KITCHEN COUNTERSPACE TO MEET 210.52C- | | | SEC'S 1,2,3,4 AND 5 | | | PLANS STILL MISSING ONES FROM FIRST | | | REVIEW. | | | | | | 4)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | SHOWN FOR SUB PANELS, BUT NOT FOR MAIN. | | | | | | 5)NOTE: PLEASE SEE RISER, PLEASE SEE | | | 250.6, 250.24. AN EQUIPMENT GROUDING | | | CONDUCTOR AS SHOWN SHALL NOT BE INSTALL- | | | ED AND MUST BE REMOVED. | | | | | | 6)NOTE: PLEASE SEE PANEL SCHEDULES. | | | THERE ARE MANY 220V/2-POLE ITEMS SHOWN | | | AS 1-POLE BRKRS? MISPRINT? | | | | | | 7)NOTE: PLEASE SEE PLANS NOW REFERENCE | | | THE FBC FOR ARC FAULT PROTECTION. | | | 210.12 FOR ARC FAULT PROETCTION IS FROM | | | THE 2002 NEC. | | | | | | 8 )NOTE: PLEASE CORRELATE RISER DIGRAM(S | | | WITH PANEL SCHEDULE(S). | | | RISER SHOWS #3 FOR CONDUCTORS TO SUB | | | PANEL. PLEASE INDICATE # OF #3'S. | | | | | | 9)NOTE: PLEASE SEE NOTE #9 MENTIONS: | | | ALL CONDUCTORS TO BE #12, YET PANEL | | | SCHEDULES INDICATE #14'S???? | | | | | | 10)NOTE: PLEASE SEE RECEPT IN MASTERBATH | | | DOES NOT MEET 210.52D. | | | | | | 11)NOTE: PLEASE SEE FS 481.219 AND | | | FAC 61G1-16.004. PLEASE INCLUDE ALL | | | LICENSE #'S REQ'D IN TITLE BLOCK. | | | PLEASE SEE MISSING CERTIFICATE OF AUTH- | | | -ORIZATION #. | | | | | | 12) NOTE: PLEASE SHOW LOAD CALCS AS | | | REQ'D UNDER NEC 220. PLEASE SHOW ALL MIN | | | CIRCUITS AND LOADS. 215.5 | | | | | | 13)NOTE: PLEASE SEE NOTICE IS NOW GIVEN | | | FOR FS 553.80(2)(B). | | | IF PLANS COME BACK FOR 3RD REVIEW AND | | | ANY OF THE SAME COMMENTS FROM THE FIRST | | | TWO REVIEWS FOR CODE COMPLIANCE ARE NOT | | | ADDRESSED, A 4X FEE WILL BE ACCESSED | | | FOR PLAN REVIEW PORTION. | | | | | | 14)NOTE: PLEASE SHOW SUB PANEL "B" ON | | | PLANS. ONLY PANEL "A" IS SHOWN. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-03-01 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-04-22 |
Time |
14:04 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-03-01 |
Time |
12:35 |
Sent To |
P |
|
| Notes |
| 2004-03-01 00:00:00 | DENIED | | | ~~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE FEEDER FROM PANEL "A" TO PANEL | | | "B"ON THE RISER DIAGRAM IS 3/0 AND | | | #3 ON THE PANEL SCHEDULE.PLEASE | | | CORRELATE. | | | | | | 2} PANEL "B"IS MARKED PANEL"A" ON THE | | | RISER DIAGRAM. | | | | | | 3} PLEASE NOTE THAT THE SMOKE DETECTORS | | | MUST BE ON AN ARC FAULT BREAKER PER | | | 210.12, SEE DEFINITION OF OUTLETS" IN | | | ARTICLE 100 NEC. | | | | | | 4} THE RECEPTACLE IN THE MASTER BATH | | | DOES NOT COMPLY WITH 210.52(D),IT'S | | | MORE THAN 3' FROM THE BASIN. | | | | | | 5} THERE ARE 2 PLACES ON THE KITCHEN | | | COUNTERTOP THAT NEED ANOTHER | | | RECEPTACLE PER 210.52(C)(1). | | | | | | 6} THE ISLAND IN THE KITCHEN NEEDS A | | | RECEPTACLE PER 210.52(C)(2). | | | | | | 7) THE LOCATION OF THE A/C DISCONNECTS | | | DO NOT COMPLY WITH 110.26 FOR CLEARANCE. | | | | | | 8} A RECEPTACLE AT THE FRONT OF THE | | | DWELLING MUST BE ADDED PER 210.52(E). | | | | | | 9} PLEASE NOTE THAT THE ARCHITECTS | | | SIGNATURE IS REQUIRED ON HIS/HER SEAL | | | PER 61G116.003.INITIALS ARE NOT | | | ACCEPTABLE. | | | | | | ONE SET OF THE PLANS SUBMITTED HAVE BEEN | | | REVIEWED AND CODE ARTICLES PER COMMENTS | | | ARE MARKED ON THE PLANS. IF THERE ARE | | | ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-02-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-15 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-15 |
Time |
14:36 |
Sent To |
P |
|
| Notes |
| 2005-02-15 00:00:00 | TO P BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-02-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-11 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-11 |
Time |
10:45 |
Sent To |
E |
|
| Notes |
| 2005-02-11 00:00:00 | TO DPALMER DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-12-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-20 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-20 |
Time |
15:44 |
Sent To |
G |
|
| Notes |
| 2004-12-20 00:00:00 | SENT TO "GAS" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-25 |
Time |
12:51 |
Sent To |
B |
|
| Notes |
| 2004-06-25 00:00:00 | TO AL DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-06-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-11 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-11 |
Time |
10:49 |
Sent To |
B |
|
| Notes |
| 2004-06-11 00:00:00 | TO LS DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-05-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-12 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-12 |
Time |
16:57 |
Sent To |
E |
|
| Notes |
| 2004-05-12 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-04-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-04-22 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-04-22 |
Time |
14:04 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-04-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-04-21 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-20 |
Time |
12:33 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-04-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-20 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-24 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2004-02-25 00:00:00 | TO Z | | | TO SFD RACK/E |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-05-17 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2004-05-17 |
Time |
17:19 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2004-05-17 |
Time |
17:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-05-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-13 |
Time |
07:41 |
Rev Time |
0.35 |
| Received By |
hmoser |
Date |
2004-05-03 |
Time |
16:16 |
Sent To |
B |
|
| Notes |
| 2004-05-03 00:00:00 | DENIED: | | | 2ND REQUEST: | | | 1.PROVIDE ENERGY AND MANUAL J | | | CALCULATIONS PER 2001 FBC CHAPTER 13. | | | | | | 1ST REQUEST: | | | 1.BEDROOM #2 MISSING RETURN AIR DUCT | | | & GRILLE SIZE & LAYOUT. | | | | | | 2.SUPPLY DUCT TO BEDROOM #3 IS NOT | | | SIZED.PLEASE REVISE. | | | | | | 3.AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 FBC(M) | | | 307.2.3. | | | | | | 4.PROVIDE OUTSIDE AIR CALCULATIONS PER | | | 2001 FBC(M) 402.2 OR 403.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-02-28 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2004-02-28 |
Time |
13:25 |
Rev Time |
0.25 |
| Received By |
hmoser |
Date |
2004-02-28 |
Time |
13:24 |
Sent To |
E |
|
| Notes |
| 2004-02-28 00:00:00 | MECHANICAL CONTRACTOR MUST SUBMIT | | | MANUAL (J) ENERGY CALCULATIONS AND PLANS | | | AT TIME OF APPLICATION | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-02-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-02-26 |
Time |
08:59 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-02-26 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-05-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-23 |
Time |
20:38 |
Rev Time |
1.50 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
M |
|
| Notes |
| 2004-05-03 00:00:00 | PROVISO: PLUMBING, GAS PLAN REVIEW. | | | SHT P-1 SEE RED LINED ITEMS, PLUMBING | | | PLAN VIEW. | | | SHT P-1 GAS, SEPERATE PLANS & PERMIT,NO | | | PIPING SHOWN. | | | QUESTIONS 561-805-6692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-03-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-01 |
Time |
14:20 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2004-03-13 |
Time |
07:13 |
Sent To |
B |
|
| Notes |
| 2004-03-13 00:00:00 | DENIED; | | | ARCHITECTS SIGNITURE IS REQUIRED ON SEAL | | | PER 61G116.003. | | | PLUMBING DRAWINGS ARE NOT TO CODE. SEE | | | SEE RED COMMENTS MARKED ON PLANS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-04-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-04-21 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-04-21 |
Time |
11:26 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-02-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-20 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-02-24 |
Time |
13:01 |
Sent To |
I |
|
| Notes |
| 2004-02-24 00:00:00 | DENIED, SIDE ENTRY GARAGE SHOULD BE 15FT | | | CALLED PETER (PERMIT RUNNER) |
|
|