| Plan Review Stops For Permit 04021066 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2004-07-26 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-07-26 |
Time |
16:24 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2004-07-26 |
Time |
16:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2004-07-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-26 |
Time |
15:57 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2004-07-23 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2004-07-23 00:00:00 | DENIED | | | SAME COMMENT 5TH REVIEW: | | | | | | PRODUCT APPROVAL FOR TOWN AND COUNTRY | | | SHUTTERS STILL MISSING STATE APPROVAL | | | COVER SHEET. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2004-07-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-22 |
Time |
12:46 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2004-07-21 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2004-07-21 00:00:00 | DENIED | | | THIS IS THE 5TH REPETITIVE COMMENT | | | FOR PRODUCT APPROVALS. | | | I SORTED THROUGH THE STATE APPROVALS YOU | | | SUBMITTED AND ATTACHED THEM TO THE | | | PRODUCT APPROVALS. | | | I AM STILL MISSING 8 COMPLETED SETS WITH | | | STATE APPROVALS AND AM MISSING ALL | | | APPROVALS FOR SIMPSON FASTENERS USED. | | | | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-07-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-19 |
Time |
17:07 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2004-07-16 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2004-07-21 00:00:00 | DENIED | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 | | 2004-07-16 00:00:00 | DENIED | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-07-15 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-07-15 |
Time |
08:35 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2004-07-15 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2004-07-15 00:00:00 | DENIED | | | 1. BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 2.PRODUCT APPROVALS:ONE COPY OF | | | ROOFING PRODUCT APPROVALS MISSING. | | | SUBMIT TWO COPIES OF TRUSS CONNECTOR | | | PRODUCT APPROVALS. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | | AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 3. THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | 4.ADDITIONAL PERMIT FEES ARE STILL DUE | | | $124.54. | | | | | | ANY QUESTIONS CALL ME | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-07-14 |
Time |
15:00 |
Rev Time |
1.75 |
| Received By |
alange |
Date |
2004-06-17 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2004-06-17 00:00:00 | DENIED | | | COMMENTS NOT ADDRESSED FROM FIRST REVIEW | | | | | | 1. BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 2. PROVIDE AT LEAST ONE BATHROOM WITH | | | A DOOR THAT HAS A 29 INCH CLEAR OPENING | | | AS REQUIRED.A 32" WIDE DOOR IS NEEDED. | | | | | | 3.PRODUCT APPROVALS: | | | 1 COPY OF ROOF PRODUCT APPROVALS MISSING | | | GARAGE OVERHEAD DOOR PRODUCT APPROVAL | | | MISSING.NO TRUSS CONNECTOR PRODUCT | | | APPROVAL SUBMITTED. | | | BUTT GLASS PRODUCT APPROVAL SUBMITTED | | | BUT NOT SHOWN ON PLAN. | | | | | | 4. BASED ON SBCCI BUILDING VALUATION | | | DATA THE REVISED VALUE IS $287,331 | | | ADDITIONAL PERMIT FEES OF $124.54 ARE | | | DUE. | | | | | | 5.SUBMIT SIGNED AND SEALED COPY OF | | | SOIL REPORT. | | | | | | 6. THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | ANY QUESTIONS CALL ME | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-03-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-06-14 |
Time |
09:03 |
Rev Time |
3.00 |
| Received By |
lsmith |
Date |
2004-03-31 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2004-03-31 00:00:00 | BUILDING PLANS REVIEW: FAILED | | | | | | 1. BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO | | | PALMBEACH COUNTY.THE ACTUAL PERMIT | | | PLANS | | | MUST BE STAMPED BY THAT OFFICE, AND A | | | COPY OF THE PAID RECEIPT ATTACHED TO | | | THE PERMIT APPLICATION.PLEASE CALL | | | (561) 233-5025 FOR MORE INFORMATION. | | | | | | 2. PROVIDE AT LEAST ONE BATHROOM WITH | | | DOOR THAT HAS A 29 INCH CLEAR OPENING, | | | AS REQUIRED BY THE 1997 FLORIDA | | | BUILDING CODE CHAPTER 11. A 32" WIDE | | | DOOR IS NEEDED. | | | | | | 3. TWO PRODUCT APPROVALS FOR THE ROOF | | | TILE WAS SUBMITTED. PLEASE CLARIFY | | | WHICH ONE IS BEING USED.ALSO NEED | | | FLORIDA PRODUCT APPROVAL FOR ROOF TILE. | | | | | | 4. PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | | ATWWW.FLORIDABUILDING.ORG. PRODUCTS | | | WITHSTATEWIDE APPROVAL ARE REQUIRED TO | | | BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | WWW.FLORIDABUILDING.ORG. SUBMIT PRODUCT | | | APPROVAL FOR THE FOLLOWING: | | | GLASS BLOCK | | | SINGLE HUNG WINDOWS | | | FIXED WINDOWS | | | ARCHED TOP WINDOWS, TRANSOM, ETC. | | | MULLIONS | | | OVERHEAD GARAGE DOORS | | | DOUBLE INSWING ENTRY DOOR | | | SINGLE OUTSWING PANEL DOOR | | | SLIDING GLASS DOORS | | | TRUSS CONNECTORS | | | HURRICANE PANELS. | | | THE APPROPRIATE DADE COUNTY OR SBCCI | | | APPROVALS MUST ACCOMPANY THE FLORIDA | | | APPROVALS. | | | | | | 5. SUBMIT KEY PLAN AND INSTALLATION | | | SCHEDULES FOR HURRICANE PANELS. | | | SPECIFY THE MOUNT TYPE, FASTENER TYPE | | | AND SPACING. | | | | | | 6. SUBMIT INFORMATION FOR GAS BBQ. MFGR | | | SPECS. | | | | | | 7. THE VALUE OF THE HOUSE IS | | | UNDERSTATED ACCORDING TO SBCCI BUIDING | | | VALUATION THE NEW VALUE IS:$287,331. | | | | | | 8. SUBMIT THE MEASUREMENTS FOR THE | | | GLASSBLOCK SHOWN ON THE RIGHT ELEVATION. | | | | | | 9. SUBMIT A SIGNED & SEALED COPY OF THE | | | SOILREPORT. | | | | | | 10. A SEPARATE PERMIT WILL BE REQUIRED | | | FOR THE ROOF. | | | | | | 11. SUBMITALS FOR A BUTT GLASS BAY | | | WINDOW WAS INCLUDED BUT PLANS DO NOT | | | SHOW A BAY WINDOW IN THIS HOUSE. | | | | | | 12. A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE FILED AT THE | | | COUNTY CLERKS OFFICE AND A COPY | | | SUBMITTED BEFORE A PERMIT CAN BE ISSUED. | | | | | | 13. THE WINDOW IN BATH #3 IS WITHIN 3' | | | OF SHOWER AND MUST HAVE SAFETY GLAZING | | | PER FBC 2405.2. | | | | | | 14. THE WINDOWS IN THE TUB/SHOWER BATH | | | AND THE MASTER BATH MUST HAVE SAFETY | | | GLAZING. | | | | | | 15. SHOW SIZE OF ATTIC ACCESS ON PLANS. | | | | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-08 |
Time |
17:17 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-06-08 |
Time |
16:49 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-05-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-05-06 |
Time |
07:41 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-05-06 |
Time |
07:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-07-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-07-14 |
Time |
15:00 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-07-14 |
Time |
14:42 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-06-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-07-13 |
Time |
17:28 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-06-14 |
Time |
07:11 |
Sent To |
B |
|
| Notes |
| 2004-06-14 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} BEDROOM #2 NEEDS A RECEPTACLE TO | | | COMPLY WITH 210.52(A)(2). | | | | | | 2} A SMOKE DETECTOR IS REQUIRED OUTSIDE | | | BEDROOM #3 PER 8-1.4.1.6.2(1) NFPA-72. | | | | | | 3} THE DISCONNECT LOCATION FOR CU #2 | | | STILL WILL NOT COMPLY WITH 110.26 | | | CLEARANCE DUE TO THE WALL LOCATION | | | ENCLOSING THE UNITS. | | | | | | 4} THE ARCHITECTS AA NUMBER IN THE TITLE | | | BLOCK IS NOT LISTED WITH THE DBPR. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-03-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-08 |
Time |
15:20 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-03-01 |
Time |
09:51 |
Sent To |
P |
|
| Notes |
| 2004-03-01 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE RISER DIAGRAM INDICATES #3/0 | | | FEEDERS TO THE 100 AMP PANEL(MARKED | | | "A"ON THE RISER) AND #3'S ON THE PANEL | | | SCHEDULE, PLEASE CORRELATE. | | | | | | 2} THE "BREAKFAST" AND "BEDROOM #3 NEED | | | RECEPTACLES ADDED TO COMPLY WITH | | | 210.52(A)(2). | | | | | | 3} THE KITCHEN COUNTERTOP NEEDS A | | | RECEPTACLE TO COMPLY WITH 210.52(C)(1). | | | | | | 4} THE GUEST BEDROOM(LABLED BEDROOM#3 | | | ON ELECTRICAL PLAN) NEEDS A SMOKE | | | DETECTOR IN THE HALLWAY OUTSIDE IN THE | | | "IMMIDIATE VICINITY" TO COMPLY WITH | | | 8-1.4.1.6.2 NFPA-72. | | | | | | 5} THE A/C DISCONNECT LOCATIONS DO NOT | | | COMPLY WITH 110.26. | | | | | | 6} PLEASE SEE 210.12 WHICH INDICATES | | | THAT THE SMOKE DETECTORS MUST ALSO BE | | | ARC FAULT PROTECTED.SEE THE DEFINITION | | | OF "OUTLET" IN ARTICLE 100,NEC. | | | | | | ALL OF THE ABOVE CORRECTIONS ARE MARKED | | | ON ONE SET OF REVIEWED PLANS FOR | | | REFERENCE. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | PLEASE NOTE THAT THE ARCHITECTS | | | SIGNATURE IS REQUIRED ON HIS/HER SEAL | | | PER 61G116.003.INITIALS ARE NOT | | | ACCEPTABLE. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-08 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-08 |
Time |
10:20 |
Sent To |
E |
|
| Notes |
| 2005-06-08 00:00:00 | TO BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-01 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-01 |
Time |
08:20 |
Sent To |
P |
|
| Notes |
| 2005-06-01 00:00:00 | TO "KSTEVENS" BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-05-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-25 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-25 |
Time |
14:00 |
Sent To |
P |
|
| Notes |
| 2005-05-25 00:00:00 | TO "P" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-04-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-29 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-29 |
Time |
11:22 |
Sent To |
E |
|
| Notes |
| 2005-04-29 00:00:00 | TO "BTROBAUG" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-07-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-26 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-26 |
Time |
15:57 |
Sent To |
B |
|
| Notes |
| 2004-07-26 00:00:00 | TO AL DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-07-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-22 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-22 |
Time |
12:45 |
Sent To |
B |
|
| Notes |
| 2004-07-22 00:00:00 | TO AL DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-07-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-19 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-19 |
Time |
17:07 |
Sent To |
B |
|
| Notes |
| 2004-07-19 00:00:00 | TO AL DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-07-16 |
|
|
Cont ID |
|
| Sent By |
ptjomsto |
Date |
2004-07-16 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
ptjomsto |
Date |
2004-07-16 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2004-07-16 00:00:00 | 3RD RESUB GIVEN TO ART LANGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-25 |
Time |
12:53 |
Sent To |
M |
|
| Notes |
| 2004-06-25 00:00:00 | TO PK BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-08 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-08 |
Time |
15:20 |
Sent To |
E |
|
| Notes |
| 2004-06-08 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-08 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-07 |
Time |
09:55 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-03-31 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-06 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-24 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2004-02-25 00:00:00 | TO Z | | | TO SFD RACK/E |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-30 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-30 |
Time |
15:03 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-06-30 |
Time |
15:03 |
Sent To |
P |
|
| Notes |
| 2004-06-30 00:00:00 | PROVISO: | | | 1. RETURN AIR REQUIRED FROM THE DEN | | | AREA PER 2001 FBC(M) 601.4. | | | | | | 2. AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 FBC(M) | | | 307.2.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-02-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
12:53 |
Rev Time |
0.25 |
| Received By |
hmoser |
Date |
2004-02-28 |
Time |
13:13 |
Sent To |
E |
|
| Notes |
| 2004-02-28 00:00:00 | MECHANICAL CONTRACTOR MUST SUBMIT | | | ENERGY CALCELATIONS,MANUAL (J) AND PLANS | | | WHEN THEY SUBMIT APPLICATION | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-06-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-06-13 |
Time |
13:07 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-06-13 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2005-06-13 00:00:00 | PLUMBING REVISION OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-07-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-07-13 |
Time |
17:27 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-07-13 |
Time |
17:27 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-03-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-30 |
Time |
15:04 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2004-03-13 |
Time |
07:37 |
Sent To |
B |
|
| Notes |
| 2004-03-13 00:00:00 | DENIED; | | | 1.ARCHITECTS SIGNATURE REQUIRED. | | | 2.PLUMBING CODE VIOLATIONS SEE PLUMBING | | | DRAWINGS. VIOLATIONS MARKED IN RED. | | | PLUMBING PLAN REVIEW BY | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-06-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-08 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-06-08 |
Time |
12:43 |
Sent To |
I |
|
| Notes |
| 2004-06-08 00:00:00 | APPROVED BY GRACE JOYCE, PLANNER | | | 659-8031 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-02-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-07 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-02-24 |
Time |
13:05 |
Sent To |
I |
|
| Notes |
| 2004-02-24 00:00:00 | DENIED, SIDE LOAD GARAGE SHOULD BE 15FT | | | CALLED PETER (PERMIT RUNNER) |
|
|