Plan Review Details - Permit 04021018
Plan Review Stops For Permit 04021018
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-04-19 Cont ID  
Sent By alange Date 2004-04-19 Time 15:59 Rev Time 1.00
Received By alange Date 2004-04-19 Time 15:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-03-16 Cont ID  
Sent By pkrauss Date 2004-04-19 Time 07:06 Rev Time 2.00
Received By alange Date 2004-03-16 Time 10:28 Sent To  
Notes
2004-03-16 00:00:00DENIED
 1. THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSEAND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.NO PRODUCT APPROVALS SUBMITTED.
 SUBMIT 2 COPIES OF PRODUCT APPROVALS
 FOR EXTERIOR DOORS, WINDOWS, ROOFING
 AND IMPACT PROTECTION.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATIONPLEASE SEE THE STATE WEBSITE
 AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 4.WINDOW AND DOOR BUCKS SHALL COMPLY
 WITH FBC 1707.4.4.2BUCKS SHALL EXTEND
 BEYOND THE INTERIOR FACE OF THE WINDOW
 OR DOOR FRAME SUCH THAT FULL SUPPORT IS
 PROVIDED.
  
 5.SHOW ROOF AND WALL SHEATHING
 FASTENING METHOD AND SPACING.
  
 6.SUBMIT ENERGY CALCULATIONS
  
 7.PAGE A-2 NOT SIGNED FS 61G1-16.003
  
 8.BUILDING VALUATION TOO LOW.IT HAS
 BEEN ADJUSTED ACCORDING TO THE SBCCI
 BUILDING VALUATION TABLE TO $82,270
 ADDITIONAL PERMIT FEES ARE DUE.
  
 9.FBC 3401.8.2.3.1 WHEN ADDITIONS,
 OR ALTERATIONS INCREASING FLOOR AREA,
 ARE MADE TO AN EXISTING BUILDING AND
 THE ADDITION CONSTITUTES 25 % OR MORE
 OF THE AREA OF THE EXISTING BUILDING
 THE EXISTING BUILDING SHALL COMPLY WITH
 THIS SECTION.
  
 PLEASE MAKE THESE CORRECTIONS AND
 RESUBMIT PLANS.THANKYOU
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-06-14 Cont ID  
Sent By btrobaug Date 2005-06-14 Time 16:46 Rev Time 0.50
Received By btrobaug Date 2005-06-14 Time 15:36 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-03-03 Cont ID  
Sent By csiegber Date 2004-03-02 Time 08:35 Rev Time 0.50
Received By btrobaug Date 2004-03-02 Time 13:09 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-06-02 Cont ID  
Sent By adarroug Date 2005-06-02 Time 16:56 Rev Time 0.00
Received By adarroug Date 2005-06-02 Time 16:56 Sent To E
Notes
2005-06-02 00:00:00TO "BTROBAUG" DESK/REVSION

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-04-12 Cont ID  
Sent By csiegber Date 2004-04-12 Time 12:03 Rev Time 0.00
Received By csiegber Date 2004-04-12 Time 12:04 Sent To M
Notes
2004-04-12 00:00:00TO PK DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-02 Cont ID  
Sent By csiegber Date 2004-03-02 Time 08:35 Rev Time 0.00
Received By csiegber Date 2004-03-02 Time 08:35 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-25 Cont ID  
Sent By mmclean Date 2004-03-01 Time 16:35 Rev Time 0.00
Received By csiegber Date 2004-02-25 Time 12:15 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-04-19 Cont ID  
Sent By pkrauss Date 2004-04-19 Time 07:06 Rev Time 0.30
Received By pkrauss Date 2004-04-19 Time 07:01 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-03-08 Cont ID  
Sent By csiegber Date 2004-04-12 Time 12:04 Rev Time 0.25
Received By pkrauss Date 2004-03-08 Time 10:22 Sent To B
Notes
2004-03-08 00:00:00DENIED:
 1.PER REVISION TO THE 2001 FBC(M)601.4
 EFFECTIVE JUNE 30, 2003; RETURN AIR
 REQUIRED FROM THE BEDROOM AREAS.PLEASE
 REVISE PLANS TO INDICATE DUCT/GRILLE
 SIZE, MATERIAL, AND LAYOUT.SEE THE
 ATTACHED SCHEDULE FOR PROPER SIZING.
  
 2.PROVIDE ENERGY AND MANUAL J CALCS
 FOR THE ADDITION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-03-04 Cont ID  
Sent By btrobaug Date 2004-03-03 Time 13:55 Rev Time 0.33
Received By kstevens Date 2004-03-04 Time 17:24 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-03-01 Cont ID  
Sent By csiegber Date 2004-02-25 Time 12:15 Rev Time 0.00
Received By mmclean Date 2004-03-01 Time 16:35 Sent To I
Notes
***NONE***