| Plan Review Stops For Permit 04020849 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-04-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-04-09 |
Time |
10:59 |
Rev Time |
3.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-06-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2004-06-30 |
Time |
10:06 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2004-06-30 |
Time |
10:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-06-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
09:16 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-06-16 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2004-06-16 00:00:00 | | | | THE ARCHITECT MUST MAKE ALL | | | CHANGES/REVISIONS TO THE PLAN, LEGIBLY, | | | INCLUDING THE REDLINED ITEMS FROM THE | | | PREVIOUS REVIEW. | | | | | | NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-04-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-11 |
Time |
15:55 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-04-09 |
Time |
10:07 |
Sent To |
B |
|
| Notes |
| 2004-04-09 00:00:00 | | | | PROVISO | | | ~~~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | THIS PROVISO IS BEING ISSUED TO ALLOW | | | THE ELECTRICAL WORK TO BEGIN WITHOUT | | | DELAY. THERE ARE THE FOLLOWING ISSUES | | | HOWEVER,THAT NEED TO BE ADDRESSED PRIOR | | | TO ROUGH INSPECTION. | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW AS A REVISION TO THIS PERMIT. | | | | | | 1} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 2} PLEASE SEE MISSING RECEPTS FOR | | | FRONT AND/OR REAR OF DWELLING. | | | 210.52E | | | | | | 3} PLEASE SEE RECEPTS SERVING | | | KITCHEN COUNTERSPACE TO MEET 210.52C- | | | SEC'S 1,2,3,4 AND 5. SUBMIT COUNTER LOCA | | | TION PLAN ON THE DRAWING TO BE REVIEWED | | | FOR COMPLIANCE. SEE 210.8(A)(6) ALSO. | | | | | | 4} PLEASE LIST ALL THE REQ'D | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE. PER 210.52D, 210.11C3 | | | | | | 5} PLEASE SHOW OUTLET SPACING PER | | | 210.52. 2',6`,12`. SEE REDLINED PLANS, | | | REDRAW PER ACTUAL LOCATIONS. | | | | | | 6} SEE NFPA-72, 1999 EDITION FOR SMOKE D | | | ETECTOR LOCATION. (3' FROM BATH DOORS). | | | | | | 7} PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CURCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED , | | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-02-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-06 |
Time |
07:58 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-02-20 |
Time |
12:49 |
Sent To |
M |
|
| Notes |
| 2004-02-20 00:00:00 | | | | PLEASE SUBMIT PLANS FOR REVIEW PER 215.5 | | | NEC, AND 104.21 FBC AS AMMENDED BY | | | THE CITY OF WEST PALM BEACH. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-25 |
Time |
09:16 |
Sent To |
E |
|
| Notes |
| 2004-06-25 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-11 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-11 |
Time |
15:55 |
Sent To |
E |
|
| Notes |
| 2004-06-11 00:00:00 | TO BT DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-04-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-06 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-06 |
Time |
07:56 |
Sent To |
E |
|
| Notes |
| 2004-04-06 00:00:00 | TO BT BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-02-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-18 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-18 |
Time |
15:40 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-02-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-06 |
Time |
07:56 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-02-24 |
Time |
10:33 |
Sent To |
P |
|
| Notes |
| 2004-02-24 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR REVIEW | | | PERMIT APPLICATION INDICATES ALL TRADES | | | TO SUBMIT SEPARATELY.PLEASE PROVIDE | | | SCOPE OF WORK, PLANS AND EQUIPMENT | | | INFORMATION WITH MECHANICAL PERMIT | | | APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2004-04-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-02-24 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-04-16 00:00:00 | SEPERATE PERMIT MAYBE REQUIREDLM |
|
|