Plan Review Details - Permit 04020849
Plan Review Stops For Permit 04020849
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-04-16 Cont ID  
Sent By btrobaug Date 2004-04-09 Time 10:59 Rev Time 3.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-06-30 Cont ID  
Sent By jleahy Date 2004-06-30 Time 10:06 Rev Time 0.30
Received By jleahy Date 2004-06-30 Time 10:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2004-06-16 Cont ID  
Sent By csiegber Date 2004-06-25 Time 09:16 Rev Time 0.75
Received By btrobaug Date 2004-06-16 Time 17:11 Sent To  
Notes
2004-06-16 00:00:00 
 THE ARCHITECT MUST MAKE ALL
 CHANGES/REVISIONS TO THE PLAN, LEGIBLY,
 INCLUDING THE REDLINED ITEMS FROM THE
 PREVIOUS REVIEW.
  
 NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-04-09 Cont ID  
Sent By csiegber Date 2004-06-11 Time 15:55 Rev Time 0.75
Received By btrobaug Date 2004-04-09 Time 10:07 Sent To B
Notes
2004-04-09 00:00:00 
 PROVISO
 ~~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 THIS PROVISO IS BEING ISSUED TO ALLOW
 THE ELECTRICAL WORK TO BEGIN WITHOUT
 DELAY. THERE ARE THE FOLLOWING ISSUES
 HOWEVER,THAT NEED TO BE ADDRESSED PRIOR
 TO ROUGH INSPECTION.
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW AS A REVISION TO THIS PERMIT.
  
 1} PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
  
 2} PLEASE SEE MISSING RECEPTS FOR
 FRONT AND/OR REAR OF DWELLING.
 210.52E
  
 3} PLEASE SEE RECEPTS SERVING
 KITCHEN COUNTERSPACE TO MEET 210.52C-
 SEC'S 1,2,3,4 AND 5. SUBMIT COUNTER LOCA
 TION PLAN ON THE DRAWING TO BE REVIEWED
 FOR COMPLIANCE. SEE 210.8(A)(6) ALSO.
  
 4} PLEASE LIST ALL THE REQ'D
 DEDICATED BATH(S) CIRCUIT(S) ON PANEL
 SCHEDULE. PER 210.52D, 210.11C3
  
 5} PLEASE SHOW OUTLET SPACING PER
 210.52. 2',6`,12`. SEE REDLINED PLANS,
 REDRAW PER ACTUAL LOCATIONS.
  
 6} SEE NFPA-72, 1999 EDITION FOR SMOKE D
 ETECTOR LOCATION. (3' FROM BATH DOORS).
  
 7} PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CURCUIT(S) ON PANEL
 SCHEDULE. PLEASE SEE THAT ALL "OUTLETS"
 IN BEDROOMS ARE TO BE PROTECTED ,
 INCLUDING, LTS, RECEPTS, SD'S ETC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-02-20 Cont ID  
Sent By csiegber Date 2004-04-06 Time 07:58 Rev Time 0.50
Received By btrobaug Date 2004-02-20 Time 12:49 Sent To M
Notes
2004-02-20 00:00:00 
 PLEASE SUBMIT PLANS FOR REVIEW PER 215.5
 NEC, AND 104.21 FBC AS AMMENDED BY
 THE CITY OF WEST PALM BEACH.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-06-25 Cont ID  
Sent By csiegber Date 2004-06-25 Time 09:16 Rev Time 0.00
Received By csiegber Date 2004-06-25 Time 09:16 Sent To E
Notes
2004-06-25 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-06-11 Cont ID  
Sent By csiegber Date 2004-06-11 Time 15:55 Rev Time 0.00
Received By csiegber Date 2004-06-11 Time 15:55 Sent To E
Notes
2004-06-11 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-04-06 Cont ID  
Sent By csiegber Date 2004-04-06 Time 07:56 Rev Time 0.00
Received By csiegber Date 2004-04-06 Time 07:56 Sent To E
Notes
2004-04-06 00:00:00TO BT BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-18 Cont ID  
Sent By csiegber Date 2004-02-18 Time 15:40 Rev Time 0.00
Received By csiegber Date 2004-02-18 Time 15:40 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2004-02-24 Cont ID  
Sent By csiegber Date 2004-04-06 Time 07:56 Rev Time 0.35
Received By pkrauss Date 2004-02-24 Time 10:33 Sent To P
Notes
2004-02-24 00:00:00NO MECHANICAL PLANS SUBMITTED FOR REVIEW
 PERMIT APPLICATION INDICATES ALL TRADES
 TO SUBMIT SEPARATELY.PLEASE PROVIDE
 SCOPE OF WORK, PLANS AND EQUIPMENT
 INFORMATION WITH MECHANICAL PERMIT
 APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status N Date 2004-04-16 Cont ID  
Sent By pkrauss Date 2004-02-24 Time 10:36 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2004-04-16 00:00:00SEPERATE PERMIT MAYBE REQUIREDLM