| Plan Review Stops For Permit 04020827 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-03-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-03-15 |
Time |
11:21 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2005-03-15 |
Time |
11:21 |
Sent To |
PC |
|
| Notes |
| 2005-03-15 00:00:00 | REVISED KITCHEN LAYOUT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-11-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-12-01 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2004-11-05 |
Time |
14:58 |
Sent To |
PC |
|
| Notes |
| 2004-11-05 00:00:00 | BUILDING PROVISO: | | | 1-DRAWING A1: ARCHITECT SPECIFIES 2X | | | MULLION. PROVIDE PRODUCT APPROVAL FOR | | | THIS SIZE MULLION. | | | AND, CLEARLY INDICATE FASTENERS AND | | | ATTACHMENT OF DOORS AND WINDOWS TO THIS | | | STRUCTURAL MULLION. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 2-PROVIDE PRODUCT APPROVAL FOR ENTRY | | | DOORS WITH MISSILE IMPACT GLAZING AS | | | SPECIFIED ON ARCHITECTURAL PLANS. | | | | | | 3-PROVIDE COMPLETE SECTIONS AND DETAILS | | | OF FRAMING AT ENTRY PORCH THAT MATCH | | | ROOF FRAMING PLANS. SPECIFY ALL | | | FASTENERS, SPECIALLY AT THE ENDS. | | | CLARIFY HOW ARE BOTTOM 2X12'S ATTACHED | | | TO STEEL COLUMN AND TO MASONRY. SECTION | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-09-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-09-15 |
Time |
16:24 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2004-09-16 |
Time |
09:20 |
Sent To |
PC |
|
| Notes |
| 2004-09-15 00:00:00 | CHECKLIST: | | | 1-MODEL WAS CHANGED. NEED SURVEY SHOWING | | | NEW MODEL LAYOUT FOR ZONING APPROVAL. | | | 2-NOTICE OF COMMENCEMENT IS EXPIRED. | | | NEED RENEWED ONE. | | | 3-A)NEED FLORIDA/LOCALPRODUCT APPROVAL | | | FOR FIXED WINDOWS WITH SIZES AS SHOWN | | | ON PLAN. EG: SEE LENGTH OF WINDOW AT | | | KITCHEN AREA. | | | B)NEED FLORIDA/LOCAL PRODUCT APPROVAL | | | FOR SINGLE HUNG WINDOWS. | | | 4-A)MULLION PRODUCT APPROVAL: | | | CLEARLY INDICATE SIZE OF MULLIONS AND | | | ANCHOR TYPE AND SPACING TO BE USED IN | | | ORDER TO CHECK IF IT WILL MEET THE | | | DESIGN PRESSURES CALCULATED ON PLANS. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | 5-CLEARLY SPECIFY HOW ARE FIXED WINDOWS | | | AND DOORS ATTACHED TO THE STRUCTURAL | | | MULLIONS. SECTION 104.2.1.2 OF CITY | | | AMENDMENTS TO FBC 2001. | | | 6-STORM SHUTTERS NOTE ON PAGE A1 CALLS | | | FOR SHUTTERS ON GLAZED OPENINGS AND | | | HURRICANE MISSILE IMPACT GLAZING ON | | | ENTRY DOOR. PRODUCT APPROVAL PACKAGE | | | SUBMITTED IS FOR MISSILE IMPACT GLASS | | | IN ALL DOORS AND WINDOWS EXCEPT ENTRY | | | DOOR. ARCHITECT'S NOTE AND PRODUCT | | | APPROVAL SUBMITTAL NEED TO MATCH. | | | AND, IF ENTRY DOORS WILL NOT HAVE | | | IMPACT GLASS, THEN PROVIDE COMPLETE | | | INFO. FOR STORM SHUTTERS (FL. PRODUCT | | | APPROVAL AND INSTALLATION SCHEDULE). | | | 7-DETAIL C/7 DOESN'T MATCH CONDITIONS | | | SHOWN ON ROOF FRAMING. PROVIDE DETAIL | | | THAT SHOWS ACTUAL CORNER CONDITION AND | | | SPECIFY ALL FASTENERS. SEC. 104.2.1.2 | | | CITY AMENDMENTS TO FBC 2001. | | | 8-DETAIL G/7:SPECIFY HOW IS 2X4 BLOCKING | | | ATTACHED TO TRUSSES. SEC. 104.2.1.2 | | | CITY AMENDMENTS TO FBC 2001. | | | 9-PROVIDE COMPLETE SECTION DETAIL AT | | | ENTRY PORCH SHOWING HOW IS FRONT WALL | | | FRAMED. SPECIFY ALL FASTENERS TOP AND | | | BOTTOM AND FRAMING AROUND OPENINGS. | | | SEE FRONT ELEVATION. SEC. 104.2.1.2 | | | CITY AMENDMENTS TO FBC 2001. | | | 10-SHEET A7: CROSS SECTIONS DRAWINGS FOR | | | BEAMS AND LINTELS HAVE THE COPY OF THE | | | ENGINEER'S SEAL. NEED ORIGINAL SEAL, | | | SIGNATURE AND DATE FROM THE ENGINEER | | | AS REQUIRED BY CHAPTER 471 FLORIDA | | | STATUTES WHEN SUBMITTING DOCUMENTS FOR | | | PUBLIC RECORDS. | | | B)CROSS SECTIONS DRAWINGS AREN'T LEGIBLE | | | NEED LEGIBLE DRAWINGS. | | | 11-OWES $2258.84 FOR UPDATE VALUATION | | | WITH CHANGE OF MODEL, RESUBMITTAL FEE | | | AND BALANCE DUE BECAUSE ONLY PARTIAL | | | PAYMENT WAS PAID AT TIME OF PERMIT | | | APPLICATION. ALSO, RE-SUBMITTAL FEES | | | WILL BE CHARGED AT TIME OF RESUBMITTAL | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-04-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-26 |
Time |
13:37 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2004-04-26 |
Time |
09:32 |
Sent To |
PC |
|
| Notes |
| 2004-04-26 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1-NOTICE OF COMMENCEMENT IS EXPIRED.NEED | | | TO RENEW IT. | | | 2-REVISE/CLARIFY SHEET A1: | | | A)STORM SHUTTERS NOTE AND WINDOW GLAZING | | | NOTE ARE CONFLICTING. CLARIFY IF USING | | | STORM SHUTTERS OR MISSILE IMPACT GLASS | | | B)NORTH ARROW IS POINTING TO THE WRONG | | | ORIENTATION. SEE SURVEY AND REVISE | | | AS REQUIRED. | | | **NOTE: SAME THING ABOUT NORTH ARROW | | | APPLIES TO SITE PLAN ON SHEET A5. | | | 3-ACCORDING TO CLARIFICATION REGARDING | | | MISSILE IMPACT PROTECTION AT GLAZED | | | OPENINGS PROVIDE COMPLETE INFORMATION | | | FOR EITHER OPTION. | | | 4-PROVIDE COMPLETE SECTION DETAIL THRU | | | ENTRY PORCH THAT MATCHES ROOF FRAMING | | | PLAN. DETAILS ON SHEET A6 FOR KNEE | | | WALL AND ENTRY PORCH SEC. DON'T MATCH. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | WHERE IS DETAIL E/6 TAKEN AT?. | | | 5-CLEARLY SPECIFY ON PLANS IF ATTIC | | | SPACE ABOVE GARAGE IS TO BE USED FOR | | | STORAGE OR NOT. SEE TABLE 1604.1 FBC | | | 2001. FOR REQUIRED DESIGN CRITERIA. | | | 6-PROVIDE ATTIC ACCESS AT GUEST HOUSE. | | | SEC. 2309.6 FBC 2001. | | | 7-PROVIDE COMPLETE SECTION THRU BAY | | | WINDOW. SEC. 104.2.1.2 CITY AMENDMENTS | | | TO FBC 2001. | | | 8-PLEASE PROVIDE ONLY THE DETAILS THAT | | | APPLY TO THIS HOUSE TO EXPEDITE THE | | | REVIEW PROCESS. | | | 9-PRODUCT APPROVAL PACKAGE: A)FIXED | | | WINDOWS NEED NOA AND DWGS THAT MATCH | | | FLORIDA PRODUCT APPROVAL REPORT. | | | B)PROVIDE PRODUCT APPROVAL FOR ENTRY | | | DOORS WITH IMPACT GLAZING IF THIS | | | OPTION IS TAKEN ON PLANS. | | | C)PROVIDE COMPLETE PRODUCT APPROVAL FOR | | | FRENCH DOORS WITH SIDELITES & TRANSOM | | | ABOVE SINGLE ASSEMBLY AS SHOWN ON | | | PLANS. CLEARLY SPECIFY ALL CONNECTIONS | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-03-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-21 |
Time |
19:15 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2004-03-31 |
Time |
17:04 |
Sent To |
PC |
|
| Notes |
| 2004-03-31 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1-NEED RECORDED NOTICE OF COMMENCEMENT. | | | 2-PROVIDE STRUCTURAL BUCK DETAIL @ ENTRY | | | DOORS SHOWING SIZE OF BUCK REQUIRED TO | | | CLOSE GAP ACCORDING TO MASONRY OPENING | | | SHOWN. SEC. 104.2.1.2 CITY AMENDMENTS | | | TO FBC 2001. | | | 3-ENERGY CALCULATIONS: A)SINCE THIS IS | | | NOT A WORST CASE SCENARIO CALCS, THEN | | | ORIENTATION OF OPENINGS NEED TO MATCH | | | PLANS. ALSO, OPENINGS TO MATCH PLANS. | | | B)REVISE OVERHANG LENGTH AND HEIGHT TO | | | MATCH FLOOR PLANS. | | | 4-PROVIDE COMPLETE FLORIDA OR LOCAL | | | PRODUCT APPROVAL FOR: | | | A)ALL STRUCTURAL CONNECTORS. | | | B)FRENCH DOORS WITH TRANSOM ABOVE SINGLE | | | ASSEMBLY AS SHOWN ON PLANS. | | | C)FIXED WINDOWS FOR BIG SIZES AS SHOWN | | | ON PLANS. | | | D)ROOF TILE | | | E)WINDOW MULLIONS. | | | F)GLASS BLOCK. 2 COPIES. | | | | | | 5-PROVIDE APROVAL AND SPECS FOR BBQ AS | | | REQUIRED BY SEC. 2808 FBC 2001. | | | 6-CLARIFY IF USING MISSILE IMPACT GLASS | | | OR SHUTTERS. SEE NOTE ON SHEET A1 AND | | | PROVIDE COMPLETE INFORMATION OF EITHER | | | OPTION. | | | 7-SPECIFY FASTENERS FOR 2X4 BLOCKING AT | | | ARCHED OPENINGS. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | 8-PROVIDE COMPLETE KNEE WALL DETAIL AT | | | ENTRY PORCH. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | 9-SPECIFY 7/8" MIN. STUCCO THICKNESS AT | | | FRAMED WALLS AS REQ'D BY ASTM C-926. | | | 10-SPECIFY SAFETY GLASS AS REQUIRED BY | | | SEC. 2405.2(IF NOT USING IMPACT GLASS) | | | B)GLASS BLOCK TO HAVE SAFETY GLASS ALSO | | | IF FACE THICKNESS IS LESS THAN 0.25". | | | SPECIFY FACE THICKNESS TO BE USED. | | | 11-SHEET A3: A)CLARIFY IF ATTIC ABOVE | | | GARAGE AREA IS DESIGNEDFOR STORAGE | | | OR NOT STORAGE. ATTIC ACCESS W/ LADDER | | | SUGGESTS ATTIC TO BE USED FOR STORAGE. | | | IF SO, THEN PROVIDE SPECIFICATIONS. | | | SEE TABLE 1604.1 FBC 2001. | | | B)ATTIC LIVE LOAD IS MEASURED IN PSF, | | | NOT PSI. REVISE NOTE AS REQUIRED. | | | 12-DRAWINGS ON SHEET A1 ARE NOT LEGIBLE. | | | 13-PROVIDE ATTIC ACCESS AT GUEST HOUSE. | | | SEC. 2309.6 FBC 2001. | | | 14-PROVIDE COMPLETE SECTION THRU BAY | | | WINDOW. SEC. 104.2.1.2 CITY AMENDMENTS | | | TO FBC 2001. | | | 15-PROVIDE COMPLETE LEDGER DETAIL FOR | | | ROOF TRUSSES @ ENTRY PORCH. SEE PLANS. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | 16-PLEASE PROVIDE ONLY THE DETAILS THAT | | | APPLY TO THIS HOUSE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | BACK AT 805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2005-08-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-12 |
Time |
07:25 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-08-12 |
Time |
07:16 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2005-03-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-03-02 |
Time |
15:58 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-03-02 |
Time |
15:17 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-11 |
Time |
17:02 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-01-11 |
Time |
16:45 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-12-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-12-01 |
Time |
14:00 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-12-01 |
Time |
13:17 |
Sent To |
B |
|
| Notes |
| 2004-12-01 00:00:00 | | | | PROVIS0 | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW PRIOR TO ROUGH INSPECTION. | | | | | | 1} PLEASE SEE THAT A #2 EQUIPMENT | | | GROUND IS SHOWN BEING RAN WITH THE | | | FEEDERS TO THE PANELS FROMTHE | | | DISCONNECTS.VERIFY THE SIZE OF SAME. A | | | #6 IS REQUIRED PER 250.122. | | | | | | 2} THE #2 EQUIPMENT GROUND RUNNING | | | BETWEEN DISCONNECTS IS IN VIOLATION OF | | | 250.6(B) AND MUST NOT BE INSTALLED. | | | | | | 3} THERE IS A POOL PUMP SHOWN ON THE | | | DRAWINGS BUT NONE LISTED IN THE | | | CALCULATIONS.ALSO IF THE POOL IS TO BE | | | HEATED PLEASE SHOW THAT CALCULATION. | | | | | | 4} AIR HANDLER #2 IS SHOWN ON THE | | | CALCULATIONS @ 7.5 KW AND LISTED ON THE | | | MECHANICAL PLANS AS 10KW. PLEASE | | | CORRELATE. | | | | | | 5} THE LOAD CALCULATIONS MUST CONTAIN A | | | CALCULATION FOR THE DRYER PER 220.18. | | | | | | 6} PLEASE SHOW THE RECEPTACLE LOCATION | | | FOR THE "WHIRL-TUB" AND SHOW GFI | | | COMPLIANCE PER 680.62(A). | | | | | | 7} RECEPTACLES NEED TO BE ADDED | | | TO BEDROOM #4 TO COMPLY WITH | | | 210.52(A)(2). | | | | | | ONE SET OF REVIEWED PLANS ARE MARKED TO | | | INDICATE THE AREAS OF COMMENTS.PLEASE | | | SEE THIS SET AND CALL IF THERE ARE ANY | | | QUESTIONS. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-08-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-19 |
Time |
08:42 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-08-19 |
Time |
08:42 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-04-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-13 |
Time |
12:44 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-04-21 |
Time |
19:14 |
Sent To |
B |
|
| Notes |
| 2004-04-21 00:00:00 | REDLINED PLANS, | | | REVISE BEFORE ROUGH. | | | | | | EQUIPMENT GRNDS ARE MISSING BETWEEN MAIN | | | -S AND PANELS. 250.110, 250.122 | | | | | | PLEASE SEE KW HAS NOW BEEN CHANGED TO | | | 10KW, HOWEVER, OCP WAS NOT INCREASED | | | PER 424.3B | | | | | | PLEASE SEE 250.66 FOR #2 MIN GEC FOR | | | 300A SERVICE. BASED ON MIN SEC'S IN | | | 310.15B6 | | | PLEASE ADJUST. | | | | | | PLEASE SUBMIT REVISED PLANS BEFORE ROUGH |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-03-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-20 |
Time |
16:32 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-03-02 |
Time |
08:40 |
Sent To |
M |
|
| Notes |
| 2004-03-02 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE SEE THAT A #2 EQUIPMENT | | | GROUND | | | IS SHOWN BEING RAN WITH THE FEEDERS TO | | | THE PANELS FROMTHE DISCONNECTS.VERIFY | | | THE SIZE OF SAME. A # 6 IS REQUIRED PER | | | 250.122. | | | | | | 2} THE #2 EQUIPMENT GROUND RUNNING | | | BETWEEN DISCONNECTS IS IN VIOLATION OF | | | 250.6(B) AND MUST NOT BE INSTALLED. | | | | | | 3} THE LAUNDRY CIRCUIT MUST BE | | | CALCULATED AT 1500 VA PER 220.16(B) | | | | | | 4} THERE IS A POOL PUMP SHOWN ON THE | | | DRAWINGS BUT NONE LISTED IN THE | | | CALCULATIONS.ALSO IF THE POOL IS TO BE | | | HEATED PLEASE SHOW THAT CALCULATION. | | | | | | 5} AIR HANDLER #2 IS SHOWN ON THE | | | CALCULATIONS @ 7.5 KW AND LISTED ON THE | | | MECHANICAL PLANS AS 10KW. PLEASE | | | CORRELATE. | | | | | | 6} THE LOAD CALCULATIONS MUST CONTAIN A | | | CALCULATION FOR THE DRYER PER 220.18. | | | | | | 7} PLEASE ADD A RECEPTACLE AT THE FRONT | | | OF THE HOUSE PER 220.52(E). | | | | | | 8} PLEASE SHOW THE RECEPTACLE LOCATION | | | FOR THE "WHIRL-TUB" AND SHOW GFI | | | COMPLIANCE PER 680.62(A). | | | | | | 9} RECEPTACLES NEED TO BE ADDED | | | TO BEDROOMS #3 & #4 TO COMPLY WITH | | | 210.52(A)(2). | | | | | | ONE SET OF REVIEWED PLANS ARE MARKED TO | | | INDICATE THE AREAS OF COMMENTS.PLEASE | | | SEE THIS SET AND CALL IF THERE ARE ANY | | | QUESTIONS. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-08-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-08 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-08 |
Time |
10:58 |
Sent To |
E |
|
| Notes |
| 2005-08-08 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-02-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-25 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-25 |
Time |
16:48 |
Sent To |
E |
|
| Notes |
| 2005-02-25 00:00:00 | TO "BT" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-03 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-03 |
Time |
15:22 |
Sent To |
E |
|
| Notes |
| 2005-01-03 00:00:00 | TO "BT" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-11-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-19 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-19 |
Time |
14:33 |
Sent To |
P |
|
| Notes |
| 2004-11-19 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-10-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-20 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-20 |
Time |
16:43 |
Sent To |
P |
|
| Notes |
| 2004-10-20 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-08-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-13 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-13 |
Time |
12:44 |
Sent To |
E |
|
| Notes |
| 2004-08-13 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-04-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-20 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-20 |
Time |
16:32 |
Sent To |
E |
|
| Notes |
| 2004-04-20 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-03-31 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-19 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2004-02-19 |
Time |
12:17 |
Sent To |
PC |
|
| Notes |
| 2004-02-20 00:00:00 | TO SFD RACK/E | | 2004-02-19 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-02-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-02-08 |
Time |
11:27 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-02-08 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2005-02-08 00:00:00 | REVISION APPROVED BY PAT RAFTER 1-13-05 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-08-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-21 |
Time |
13:36 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-08-26 |
Time |
13:36 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-03-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-02 |
Time |
10:58 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-03-05 |
Time |
06:26 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2005-03-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-03-09 |
Time |
16:33 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-03-09 |
Time |
16:33 |
Sent To |
B |
|
| Notes |
| 2005-03-09 00:00:00 | REVISED RISER DIAGRAM ADDED BAR SINK TO | | | RISER DIAGRAM PER KEN STEVEN'S PROVISO. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-01-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-12 |
Time |
10:29 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-01-12 |
Time |
10:29 |
Sent To |
M |
|
| Notes |
| 2005-01-12 00:00:00 | REVISION; BAR SINK ADDED TO RISER | | | DIAGRAM AS REQUESTED BY KEN STEVENS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-11 |
Time |
17:04 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-11-30 |
Time |
18:31 |
Sent To |
E |
|
| Notes |
| 2004-11-30 00:00:00 | PASSED/PROVISO - REVISION REQUIRED. NO | | | BAR SINK SHOWN ON THE RISER DIAGRAM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-08-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-20 |
Time |
16:43 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-08-21 |
Time |
13:36 |
Sent To |
M |
|
| Notes |
| 2004-08-21 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | | | | 1) SHT A4 SANITARY RISER DIAGRAM DOES | | | NOT REFLECT THE FLOOR PLAN AT THE MASTER | | | BATH. SHOWS A DRY HORIZONTAL VENT NEXT | | | TO THE W/C AND SHOWS 2 LAVS ON RISER AND | | | ONLY ONE LAV ON THE FLOOR PLAN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-03-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-19 |
Time |
08:42 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-03-08 |
Time |
17:29 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-11-05 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2004-11-05 00:00:00 | RESTAMP PLANS MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-02-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-09-15 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-02-19 |
Time |
16:27 |
Sent To |
I |
|
| Notes |
|
|