Plan Review Details - Permit 04020751
Plan Review Stops For Permit 04020751
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-04-19 Cont ID  
Sent By rmcdouga Date 2004-04-19 Time 07:31 Rev Time 2.00
Received By rmcdouga Date 2004-04-19 Time 07:31 Sent To  
Notes
2004-04-19 00:00:00BUILDING PROVISO
  
 SUBMIT STATE PRODUCT APPROVALS FOR THE
 ARCHED TOP (DESIGNER) FIXED GLASS
 WINDOWS. THE ONE SUBMITTED IS INCORRECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-03-25 Cont ID  
Sent By csiegber Date 2004-04-15 Time 14:05 Rev Time 3.00
Received By rmcdouga Date 2004-03-25 Time 10:14 Sent To  
Notes
2004-03-25 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) SPECIFY THE BOTTOM CORD LIVE LOAD ON
 THE PLANS. SEE FBC TABLE 1604.1.
  
 3) SPECIFY ON THE PLANS THAT THE DOOR
 FROM THE GARAGE TO THE CONDITIONED SPACE
 IS REQUIRED TO BE INSULATED OR SOLID
 CORE AS REQUIRED BY FBC CHAPTER 13.
  
 4) REVISE THE SLIDING GLASS DOOR DETAIL
 ON A4 TO STATE THE FRAME IS FASTENED
 THROUGH THE BUCK NOT TO IT PER FBC
 1707.4.4.2.
  
 5) SUBMIT THE MANUFACTURER'S SPECS. AND
 LISTING FOR THE PREFAB FIREPLACE AND
 CHIMNEY.
  
 6) SUBMIT THE MANUFACTURER'S SPECS. AND
 LISTING FOR THE GAS BBQ AND HOOD.
  
 7) FBC 2804.2.4 REQUIRES CHIMNEYS TO
 EXTEND AT LEAST THREE FEET ABOVE THE
 HIGHEST POINT WHERE THEY PASS THROUGH
 THE ROOF AND AT LEAST 2 FEET HIGHER THAN
 ANY PORTION OF THE OF THE ROOF OR
 BUILDING LOCATED WITHIN 10 FEET
 HORIZONTALLY OF SUCH CHIMNEY. PLEASE
 CLARIFY THIS ON THE PLANS.
  
 8) SPECIFY THE CHIMNEY DIMENSIONS.
 PROVIDE CONSTRUCTION DETAILS OF THE
 OPENINGS, COLUMNS AND HEADERS SUPPORTING
 THE ROOF.
  
 9)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72.
  
 10) SUBMIT PRODUCT APPROVALS FOR THE
 9' AND 12' WIDE SLIDING GLASS DOORS.
 THE ONE SUBMITTED IS FOR A MAXIMUM DOOR
 SIZE OF 8'X 8'.
  
 11) SUBMIT PRODUCT APPROVALS FOR THE
 FOLLOWING ITEMS:
 -SINGLE OUTSWING EXTERIOR DOOR AT THE
 GARAGE
 - CASEMENT WINDOWS IN THE DEN AND DINING
 ROOM
 - ARCHED TOP FIXED GLASS WINDOW ABOVE
 THE ENTRY DOORS
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-07-08 Cont ID  
Sent By btrobaug Date 2005-07-08 Time 13:18 Rev Time 0.50
Received By btrobaug Date 2005-07-08 Time 12:17 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-02-25 Cont ID  
Sent By btrobaug Date 2004-02-25 Time 11:39 Rev Time 0.75
Received By btrobaug Date 2004-02-25 Time 10:56 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-07-08 Cont ID  
Sent By adarroug Date 2005-07-08 Time 11:40 Rev Time 0.00
Received By adarroug Date 2005-07-08 Time 11:40 Sent To E
Notes
2005-07-08 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-04-15 Cont ID  
Sent By csiegber Date 2004-04-15 Time 14:05 Rev Time 0.00
Received By csiegber Date 2004-04-15 Time 14:04 Sent To B
Notes
2004-04-15 00:00:00TO RM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-03-25 Cont ID  
Sent By mmclean Date 2004-02-19 Time 10:06 Rev Time 0.00
Received By rmcdouga Date 2004-02-17 Time 16:33 Sent To  
Notes
2004-02-19 00:00:00TO SFD RACK/E
2004-02-17 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-02-26 Cont ID  
Sent By btrobaug Date 2004-02-25 Time 11:39 Rev Time 0.75
Received By hmoser Date 2004-02-26 Time 18:25 Sent To P
Notes
2004-02-26 00:00:00PASS PROVISO
 REFER TO SECTION 303.2.3 AUXILIARY DRAIN
 PANS,RETURN AIR IN BILLARD ROOM MUST BE
 12IN.
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-02-28 Cont ID  
Sent By hmoser Date 2004-02-26 Time 18:25 Rev Time 0.33
Received By jleech Date 2004-02-28 Time 09:59 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-02-19 Cont ID  
Sent By mmclean Date 2004-02-19 Time 10:06 Rev Time 0.00
Received By mmclean Date 2004-02-19 Time 10:06 Sent To I
Notes
***NONE***