Plan Review Details - Permit 04020747
Plan Review Stops For Permit 04020747
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-07-27 Cont ID  
Sent By btrobaug Date 2004-04-03 Time 07:35 Rev Time 0.25
Received By vmahle Date 2004-07-12 Time 14:06 Sent To  
Notes
2004-07-12 00:00:00PERMIT # DOES NOT MATCH ADDRESS AND LOT
 #. PLEASE MAKE CORRECTIONS/CHANGES
 ON SUBMITTAL FORM.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-03-23 Cont ID  
Sent By csiegber Date 2004-04-01 Time 13:13 Rev Time 2.00
Received By rmcdouga Date 2004-03-23 Time 15:48 Sent To  
Notes
2004-03-23 00:00:00DENIED
  
 1) SPECIFY THE BOTTOM CORD LIVE LOAD ON
 THE PLANS. SEE FBC TABLE 1604.1.
  
 2) THE COFFERED CEILING AREA IS NOT
 INCLUDED IN THE ATTIC AREA LISTED IN THE
 ENERGY CALCS. AS REQUIRED BY FBC CHAPTER
 13. PLEASE REVISE. ENERGY CALCS. ARE
 REQUIRED TO BE SIGNED BY THE OWNER/AGENT
  
 3) REVISE THE SLIDING GLASS DOOR BUCK
 DETAIL ON A4 TO STATE THAT THEY ARE
 FASTENED THROUGH THE BUCK AND NOT TO THE
 BUCK. SEE FBC 1707.4.4.2.
  
 4) SPECIFY ON THE PLANS THAT THE DOOR
 FROM THE GARAGE TO THE CONDITIONED SPACE
 IS INSULATED OR SOLID CORE AS REQUIRED
 BY FBC CHAPTER 13 SECTION 603.
  
 5) THE MASONRY OPENING HEIGHTS LISTED
 FOR WINDOWS (12) & (13) ON THE LEFT
 ELEVATION ON A4 ARE INCORRECT (SHOULD BE
 64"). PLEASE CORRECT.
  
 6) UPDATE THE SEMCO TRUSS CONNECTOR
 SPECIFIED IN DETAIL 9 ON A5 TO A CURRENT
 ANCHOR WITH STATE OR LOCAL APPROVAL.
  
 7)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72.
  
 8) SUBMIT PRODUCT APPROVALS FOR THE 16'
 LONG MULLION BETWEEN THE SLIDING GLASS
 DOOR AND THE TRANSOM AT THE GREAT ROOM.
 THE ONE SUBMITTED ONLY LISTS UP TO A 12'
 MULL LENGTH.
  
 9) SUBMIT PRODUCT APPROVALS FOR THE
 CASEMENT WINDOWS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-10-12 Cont ID  
Sent By btrobaug Date 2004-10-12 Time 09:16 Rev Time 0.50
Received By btrobaug Date 2004-10-12 Time 09:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2004-09-21 Cont ID  
Sent By csiegber Date 2004-10-04 Time 13:01 Rev Time 0.50
Received By btrobaug Date 2004-09-21 Time 09:49 Sent To  
Notes
2004-09-21 00:00:00 
 PLEASE SHOW THE LOCATION OF SUB-PANEL
 "B" ON THE PLAN.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-04-03 Cont ID  
Sent By csiegber Date 2004-09-14 Time 09:25 Rev Time 0.50
Received By btrobaug Date 2004-04-03 Time 07:29 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-02-23 Cont ID  
Sent By btrobaug Date 2004-02-23 Time 16:42 Rev Time 0.50
Received By btrobaug Date 2004-02-23 Time 16:42 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-10-04 Cont ID  
Sent By csiegber Date 2004-10-04 Time 13:01 Rev Time 0.00
Received By csiegber Date 2004-10-04 Time 13:01 Sent To E
Notes
2004-10-04 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-09-14 Cont ID  
Sent By csiegber Date 2004-09-14 Time 09:25 Rev Time 0.00
Received By csiegber Date 2004-09-14 Time 09:25 Sent To E
Notes
2004-09-14 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-04-01 Cont ID  
Sent By csiegber Date 2004-04-01 Time 13:12 Rev Time 0.00
Received By csiegber Date 2004-04-01 Time 13:12 Sent To B
Notes
2004-04-01 00:00:00TO RM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-03-23 Cont ID  
Sent By mmclean Date 2004-02-19 Time 10:39 Rev Time 0.00
Received By rmcdouga Date 2004-02-18 Time 09:04 Sent To  
Notes
2004-02-19 00:00:00TO SFD RACK/E
2004-02-18 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-02-28 Cont ID  
Sent By btrobaug Date 2004-02-23 Time 16:42 Rev Time 0.50
Received By hmoser Date 2004-02-28 Time 08:10 Sent To P
Notes
2004-02-28 00:00:00PASS PRIVISO
 PLESE REFER TO SECTION 601.4 BALANCED
 RETURN AIR
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-03-08 Cont ID  
Sent By hmoser Date 2004-02-28 Time 08:11 Rev Time 0.25
Received By jleech Date 2004-03-08 Time 16:47 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-02-19 Cont ID  
Sent By mmclean Date 2004-02-19 Time 10:39 Rev Time 0.00
Received By mmclean Date 2004-02-19 Time 10:39 Sent To I
Notes
***NONE***