Plan Review Details - Permit 04020698
Plan Review Stops For Permit 04020698
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-06-21 Cont ID  
Sent By jgomez Date 2004-06-21 Time 16:49 Rev Time 0.50
Received By jgomez Date 2004-06-21 Time 16:49 Sent To E
Notes
2004-06-21 00:00:00SUBMITTAL CHECKLIST:
 FROM PREVIOUS PROVISO DATED 5-11-04
 1-PROVIDE COMPLETE PRODUCT APPROVAL
 INFORMATION FOR FRENCH DOORS WITH
 SIDELITES AND TRANSOM ABOVE SINGLE
 ASSEMBLY AS SHOWN ON PLANS, ENTRY
 DOORS, OVAL AND ARCHED WINDOWS UNDER
 A SEPARATE PERMIT AS AGREED UPON BY
 MRS. HOLLY ON 5-11-04 BY PHONE.
 2-DETAIL E/6 STILL HAS NOT SPECS FOR
 FASTENERS. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 3-REVISE NOTE ON SHEET A1:
 SPECIFY IF USING STORM SHUTTERS OR
 DOORS AND WINDOWS WITH IMPACT GLAZING.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-05-11 Cont ID  
Sent By mjacobs Date 2004-06-14 Time 14:15 Rev Time 2.00
Received By jgomez Date 2004-05-11 Time 15:52 Sent To PC
Notes
2004-05-11 00:00:00BUILDING REVIEW PROVISO:
 1-PROVIDE COMPLETE PRODUCT APPROVAL FOR
 FRENCH DOORS WITH SIDELITES & TRANSOM
 ABOVE SINGLE ASSEMBLY AS SHOWN ON
 PLANS UNDER A SEPARATE PERMIT AS
 AGREED UPON WITH MRS. HOLLY FROM
 DREAMSTAR HOMES (5-11-04 BY PHONE).
 B)ALSO, PROVIDE PRODUCT APPROVAL INFORMA
 TION FOR ENTRY DOORS, OVAL AND ARCHED
 WINDOWS AS SHOWN ON PLANS UNDER THIS
 NEW MISCELANEOUS PERMIT.
 2-PROVIDE COMPLETE DETAIL FOR STRUCTURAL
 FASCIA AT REAR PORCH BY CANTILEVERED
 TRUSSES. SPECIFY ALL FASTENERS. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 **PROVIDE DETAIL THAT MATCHES ACTUAL
 CONDITIONS. SEE CANTILEVERED TRUSSES.
 3-PROVIDE COMPLETE DETAIL SHOWING
 INSTALLATION OF (2)B1 CONNECTORS AT
 ENDS OF GIRDER TRUSSES AT ENTRY PORCH.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 4-PROVIDE COMPLETE KNEE WALL SECTION/DET
 AT ENTRY PORCH. SEE ROOF FRAMING PLAN
 AND PROVIDE ALSO A DETAIL SHOWING HOW
 IS 2X4 KNEE WALL ATTACHED TO TRUSSES
 BELOW THAT ARE RUNNING PARALLEL TO
 KNEE WALL. SPECIFY ALL FASTENERS. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 5-CLARIFY/REVISE NOTE ON SHEET A1. ARE
 STORM SHUTTERS TO BE USED OR NOT. IF
 SO, THEN APPLY FOR SEPARATE PERMIT.
 6-REVISE STRUCTURAL BUCK DETAIL FOR
 ENTRY DOOR TO MATCH ACTUAL CONDITIONS
 SHOWN ON PLAN. SEE SIZE OF MASONRY
 OPENING SPECIFIED ON PLANS. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 7-CLARIFY SPECS FOR CEILING INSTALLATION
 AT REAR AND ENTRY PORCH. CLARIFY WHAT
 IS A 1"X2" 16 PNEUMATIC FASTENER. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 8-COMPLETE SPECS ON DETAIL E/6. SPECIFY
 BASE SIZE AND FASTENERS. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-03-19 Cont ID  
Sent By pschmitz Date 2004-05-06 Time 17:09 Rev Time 2.50
Received By jgomez Date 2004-03-19 Time 14:42 Sent To PC
Notes
2004-03-19 00:00:00BUILDING REVIEW CHECKLIST:
 1-NEED RECORDED NOTICE OF COMMENCEMENT.
 2-PROVIDE STRUCTURAL BUCK DETAIL FOR
 ENTRY DOORS SHOWING SIZE OF BUCK REQ'D
 TO CLOSE GAP ACCORDING TO THE OPENING
 SIZE SPECIFIED ON PLANS. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 3-PROVIDE DETAIL/SPECS FOR CEILING INSTA
 LLATION AT ENTRY AND REAR PORCHES. SEE
 ASTM C-926 AND ASTM C-1063. SPECIFY
 ALL FASTENERS.
 4-ENERGY CALCULATIONS: A)REVISE CARDINAL
 ORIENTATION TO MATCH PLANS.
 B)REVISE OVERHANG LENGTH AND HEIGHT TO
 MATCH PLANS.
 5-PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR: A)STRUCTURAL CONNECTORS.
 B)FRENCH DOORS WITH TRANSOM ABOVE SINGLE
 ASSEMBLY AS SHOWN ON PLANS.
 C)IF USING NON IMPACT SINGLE HUNG WINDOW
 THEN, PROVIDE DRAWINGS THAT MATCH
 NOA SUBMITTED FOR FLORIDA APPROVAL.
 6-CLARIFY IF USING STORM SHUTTERS OR
 MISSILE IMPACT GLAZING ON DOORS AND
 WINDOWS. PRODUCT APPROVAL PACKAGE
 SUBMITTED IF FOR IMPACT AND NON IMPACT
 WINDOWS AND DOORS. PROVIDE COMPLETE
 PACKAGE FOR EITHER OPTION.
 7-SPECIFY ROOF TILE FASTENERS AS REQ'D
 BY SEC. 104.2.1.1 CITY AMENDMENTS TO
 FBC 2001 AND SEC. 1606.3 FBC 2001.
 8-PROVIDE UPLIFT CALCS FOR CONCRETE PAD
 SIZE SHOWN FOR REAR PORCH. SECTION
 2103.1(7.1) FBC 2001 AND SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 9-PROVIDE COMPLETE DETAIL FOR ENTRY AND
 REAR CONCRETE PAD FOOTING SHOWING HOW
 DEEP THE FOOTER NEED TO BE BELOW GRADE
 TO HELP SUPPORT FOR UPLIFT. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 10-SPECIFY FASTENERS FOR 2X4 BLOCKING AT
 ARCHED AND OVAL FRAMING DETAIL. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 11-SPECIFY 7/8" MIN. STUCCO THICKNESS AT
 FRAMED WALLS. SEE ASTM C-926.
 12-SPECIFY SAFETY GLASS IN MASTER BATH
 WINDOW (IF NOT USING IMPACT GLASS).
 SEC. 2405.2 FBC 2001.
 13-CAP ON DETAIL F/6 FOR STEEL COLUMNS
 AT ENTRY PORCH DON'T WORK. PROVIDE
 DETAIL THAT MATCHES ACTUAL CONDITIONS.
 14-SPECIFY CONNECTORS FOR BEAMS AT ENTRY
 PORCH THAT ARE RESTING ON MASONRY WALL
 SEE PLANS FOR COMMENTS. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 15-CLARIFY HOW ARE TRUSSES AT REAR PORCH
 SUPPORTED IF THERE IS NOT BEAM FOR
 THEM TO REST ON.SEE COMMENTS ON PLANS
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 16-SHEET A3: LIVE LOAD NOTE FOR ATTIC IS
 MEASURED ON PSF NOT PSI. REVISE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2005-01-26 Cont ID  
Sent By dpalmer Date 2005-01-26 Time 14:44 Rev Time 0.50
Received By dpalmer Date 2005-01-26 Time 14:44 Sent To  
Notes
2005-01-26 00:00:00CONTRACTOR STILL NEEDS TO BRING IN NEW
 SIGNED APPLICATION.

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2005-01-24 Cont ID  
Sent By dpalmer Date 2005-01-24 Time 19:42 Rev Time 0.50
Received By dpalmer Date 2005-01-24 Time 19:42 Sent To  
Notes
2005-01-24 00:00:00************ UNSAT ****************
  
 1)NOTE: PLEASE SEE PERMIT APPLICATION
 ON FILE IS A COPY OF CONTRACTORS
 SIGNATURES WHICH ARE REQUIRED TO BE
 ORIGINAL SIGNATURES.
 THIS HAS BEEN MENTIONED ON PREVIOUS
 REVIEW AND ALL APPLICATIONS FOR
 CONTRACTOR ARE TO BE UPDATED.
  
 2)NOTE: PLEASE CORRELATE PLANS WITH
 RISER DIAGRAM SUBMITTED.
 RISER INDICATES BOTH PANELS AS POOL
 PANELS.
 PLEASE ALSO SEE A/C COMP SUB PANEL
 COULD NOT BE LOCATED ON PLANS.
  
 3)NOTE: PLEASE SEE HAND WRITTEN CHANGES
 MAY NOT BE DONE ON PLANS WHICH ARE
 SIGNED AND SEALED.
 PLEASE SEE RECEPT/GFI ADDED.
 PLEASE ALSO SEE ITEM ADDED IN GARAGE.
 PLEASE SEE ALSO LV ITEMS ADDED.
  
 4 )NOTE: PLEASE SEE 220.3B4.
 PLEASE SHOW ALL RECESSED LTS BASED ON
 MAX WATTAGE FOR FIXTURE(S). THIS MAY
 NOT
 BE FIGURED IN W/ 3W/PER SQ FT.
 PLEASE PROVIDE FIXTURE INFORMATION ON
 LEGEND.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2004-06-23 Cont ID  
Sent By dpalmer Date 2004-06-23 Time 13:55 Rev Time 0.33
Received By dpalmer Date 2004-06-23 Time 13:55 Sent To P
Notes
2004-06-23 00:00:00************** UNSAT *************
  
 1)NOTE: PLEASE SEE PLANS ARE SEALED
 COPIES AND DO NOT CONTAIN ORIGINAL
 SIGNATURE. PLEASE SEE FS 481.221
  
  
 2)NOTE: PLEASE SEE PLANS CAME IN W/OUT
 FEE BEING PAID. PLEASE VERIFY IF THESE
 ARE RE-STAMPS OR REVISIONS?
 PLANS DO NOT CONATIN ANY REV'S FROM
 LAST REVIEWED SET?
  
 3 )NOTE: PLEASE SEE 220.3B4.
 PLEASE SHOW ALL RECESSED LTS BASED ON
 MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT
 BE FIGURED IN W/ 3W/PER SQ FT.
 PLEASE PROVIDE FIXTURE INFORMATION ON
 LEGEND.
  
 PLEASE SEE BZ ATTACHED. FEE TO BE PAID
 BEFORE PICKING UP.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-04-26 Cont ID  
Sent By jgomez Date 2004-06-21 Time 16:49 Rev Time 0.33
Received By dpalmer Date 2004-04-26 Time 06:12 Sent To P
Notes
2004-04-26 00:00:00NEW ELECTRICAL SHEET. STAMPED.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-02-25 Cont ID  
Sent By alange Date 2004-04-22 Time 13:57 Rev Time 0.50
Received By btrobaug Date 2004-02-25 Time 12:17 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-01-21 Cont ID  
Sent By mjacobs Date 2005-01-21 Time 16:27 Rev Time 0.00
Received By mjacobs Date 2005-01-21 Time 16:27 Sent To E
Notes
2005-01-21 00:00:00TO "DP" DESK/REV.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-06-14 Cont ID  
Sent By mjacobs Date 2004-06-14 Time 14:15 Rev Time 0.00
Received By mjacobs Date 2004-06-14 Time 14:14 Sent To B
Notes
2004-06-14 00:00:00TO JG DESK/SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-04-22 Cont ID  
Sent By alange Date 2004-04-22 Time 13:57 Rev Time 0.00
Received By alange Date 2004-04-22 Time 13:57 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-03-19 Cont ID  
Sent By mmclean Date 2004-02-19 Time 09:34 Rev Time 0.00
Received By jgomez Date 2004-02-17 Time 16:03 Sent To PC
Notes
2004-02-19 00:00:00TO SFD RACK/E
2004-02-17 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-02-26 Cont ID  
Sent By btrobaug Date 2004-02-25 Time 12:38 Rev Time 0.50
Received By hmoser Date 2004-02-26 Time 17:35 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2004-06-29 Cont ID  
Sent By kstevens Date 2004-06-29 Time 08:08 Rev Time 0.33
Received By kstevens Date 2004-06-29 Time 08:08 Sent To  
Notes
2004-06-29 00:00:00DENIED
 REFERENCE: FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 SIGNATURES ON PLANS ARE COPIES. ORIGINAL
 WET SIGNATURES ARE REQUIRED. G1G1-16.003
 & FS 481.2055
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-05-06 Cont ID  
Sent By dpalmer Date 2004-06-23 Time 13:55 Rev Time 1.00
Received By pschmitz Date   Time   Sent To B
Notes
2004-05-06 00:00:00RE-SUB,PES

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-02-28 Cont ID  
Sent By dpalmer Date 2004-04-26 Time 06:12 Rev Time 0.33
Received By jleech Date 2004-02-28 Time 10:14 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-02-19 Cont ID  
Sent By csiegber Date 2004-02-17 Time 16:03 Rev Time 0.00
Received By mmclean Date 2004-02-19 Time 09:34 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved