Plan Review Details - Permit 04020670
Plan Review Stops For Permit 04020670
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-05-19 Cont ID  
Sent By rmcdouga Date 2004-05-19 Time 16:42 Rev Time 1.00
Received By rmcdouga Date 2004-05-19 Time 16:42 Sent To  
Notes
2004-05-19 00:00:00REVISION TO SHEETS A3,A4 AND A6 ARE OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-03-24 Cont ID  
Sent By rmcdouga Date 2004-03-24 Time 12:57 Rev Time 2.00
Received By rmcdouga Date 2004-03-24 Time 12:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-03-15 Cont ID  
Sent By csiegber Date 2004-03-23 Time 14:35 Rev Time 2.50
Received By rmcdouga Date 2004-03-15 Time 14:42 Sent To  
Notes
2004-03-15 00:00:00DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) SUBMIT 2 COPIES OF SOIL BORING TEST
 REPORT AS REQUIRED BY FBC 1804.2.2.
  
 4) THE REDLINED CHANGES TO THE WINDLOAD
 PRESSURES FOR THE GARAGE DOOR IN THE
 SCHEDULE ON A1, ARE REQUIRED TO BE
 SIGNED AND DATED BY THE DESIGNER OF
 RECORD.
  
 5) SUBMIT THE MANUFACTURER'S SPECS. AND
 UL LISTING INFORMATION FOR THE ONE HOUR
 FIRE RATED GLASS BLOCK.
  
 6) SUBMIT STATE OR LOCAL PRODUCT
 APPROVALS FOR THE FOLLOWING:
 - OUTSWING GLAZED DOOR (G)
 - STRUCTURAL WINDOW MULLIONS
 - ROOFING MATERIAL
  
 7) CLARIFY ON SHEET A4 THAT THE 2" STR.
 MULLIONS SPECIFIED BETWEEN THE SGDS AND
 THE TRANSOM AND THE WINDOWS AND TRANSOMS
 IS THE 2X6 STEEL HEADER THAT IS DETAILED
 ON SHEET A8. IF THIS IS NOT THE CASE,
 SUBMIT PRODUCT APPROVAL FOR MULLIONS
 CAPABLE OF THE SPANS AND LOADS INDICATED
  
 8)THE 112"X 96" FIXED WINDOW (M) EXCEEDS
 THE MAXIMUM SIZE IN THE PRODUCT APPROVAL
 THE LEFT ELEVATION SHOWS THREE PANELS IN
 THIS OPENING, WHICH WOULD BE ACCEPTABLE.
 PLEASE CLARIFY AND CHANGE SCHEDULE OR
 DRAWING AND SUBMIT APPROPRIATE PRODUCT
 APPROVAL.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-04-27 Cont ID  
Sent By dpalmer Date 2004-04-27 Time 19:23 Rev Time 0.25
Received By dpalmer Date 2004-04-27 Time 19:22 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-03-12 Cont ID  
Sent By csiegber Date 2004-04-26 Time 09:11 Rev Time 0.50
Received By btrobaug Date 2004-03-12 Time 07:00 Sent To B
Notes
2004-03-12 00:00:00TO LUIS./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-04-26 Cont ID  
Sent By csiegber Date 2004-04-26 Time 09:10 Rev Time 0.00
Received By csiegber Date 2004-04-26 Time 09:10 Sent To E
Notes
2004-04-26 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-23 Cont ID  
Sent By csiegber Date 2004-03-23 Time 14:35 Rev Time 0.00
Received By csiegber Date 2004-03-23 Time 14:35 Sent To B
Notes
2004-03-23 00:00:00TO RM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-03-15 Cont ID  
Sent By mmclean Date 2004-03-15 Time 13:05 Rev Time 0.00
Received By csiegber Date 2004-02-13 Time 12:34 Sent To  
Notes
2004-03-11 00:00:00TO LM TO PROCESS ASAP
2004-03-10 00:00:00CONTR CALLED NO REVIEWS AS OF 3/10 ON
 KM DESK/DEE

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-05-17 Cont ID  
Sent By hmoser Date 2004-05-17 Time 18:25 Rev Time 0.25
Received By hmoser Date 2004-05-17 Time 18:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-03-11 Cont ID  
Sent By pschmitz Date 2004-05-12 Time 13:11 Rev Time 0.33
Received By pkrauss Date 2004-03-11 Time 13:42 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-05-12 Cont ID  
Sent By pschmitz Date 2004-05-12 Time 13:11 Rev Time 1.00
Received By pschmitz Date   Time   Sent To M
Notes
2004-05-12 00:00:00PLUMBING REVISIONS, OK

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-03-12 Cont ID  
Sent By dpalmer Date 2004-04-27 Time 19:23 Rev Time 0.33
Received By kstevens Date 2004-03-12 Time 08:50 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-03-10 Cont ID  
Sent By csiegber Date 2004-03-10 Time 14:34 Rev Time 0.00
Received By mmclean Date 2004-03-10 Time 16:53 Sent To I
Notes
***NONE***