Plan Review Details - Permit 04020440
Plan Review Stops For Permit 04020440
Review Stop B BUILDING (STRUCTURAL)
Rev No 11 Status F Date 2005-05-19 Cont ID  
Sent By shill Date 2005-05-19 Time 14:21 Rev Time 0.50
Received By shill Date 2005-05-19 Time 14:21 Sent To Z
Notes
2005-05-19 00:00:00****CORRECTIONS****
 REVISION, ES1
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)PLEASE RESUBMIT WITH CALCS.
  
 2.)SUBJECT TO ZONING APPROVAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 10 Status P Date 2005-05-16 Cont ID  
Sent By shill Date 2005-05-16 Time 17:02 Rev Time 0.50
Received By shill Date 2005-05-16 Time 17:02 Sent To PC
Notes
2005-05-16 00:00:00DOOR/HARDWARE SUBMITTALS - PROVISO, IN
 ACCORDANCE WITH APPROVED PLAN AND FBC

Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status F Date 2005-05-16 Cont ID  
Sent By shill Date 2005-05-16 Time 11:22 Rev Time 0.50
Received By shill Date 2005-05-16 Time 11:22 Sent To  
Notes
2005-05-16 00:00:00****CORRECTIONS****
 SITE LIGHTING SHOP SUBMITTALS
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)DOCUMENTS PREPARED BY AN ENGINEER
 SUBMITTED FOR PUBLIC RECORD ARE TO BE
 SIGNED AND SEALED, FAC61G15-23.002.THE
 PRINTED NAME AND LICENSE NUMBER OF THE
 INDIVIDUAL SEALING THE DOCUMENT IS TO BE
 ON THE PLAN (COVER LETTER FROM TSENG).
  
 2.)THE CALCS PREPARED BY HARDY
 ENGINEERING (PAGE 6) NEED A TITLE BLOCK
 IN COMPLIANCE WITH FAC61G15-23.002.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2005-02-24 00:00:002-24-05 BLDG 3 2 SUBMITTALS:
 SOIL PRE-TREATMENT
 CONCRETE MIX DESIGN
 ALTERNATE CONCRETE MIX DESIGN
 NON SHRINKING HS GROUT
 FORM RELEASE
 TRUSS ANCHORS
 INSULATION
 STUCCO & ACCESSORIES
 EXTERIOR CAULKING
 EXTERIOR WALL SHEATHING
 BONDING AGENT
 STEEL COLULMNS
 CONSTRUCTION & SUB-FLOOR SEALENT
 TUNNEL TIE CONNECTORS
 ROOFING MATERIALS
 TRUSS SHOP DRAWINGS
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2004-11-22 Cont ID  
Sent By jwitmer Date 2004-11-22 Time 08:48 Rev Time 0.55
Received By jwitmer Date 2004-11-22 Time 08:48 Sent To  
Notes
2004-11-22 00:00:0011-22-04 SUBMITTALS PRODUCT APPROVALS
 EXTERIOR METAL FRAMING SHOP DRAWINGS

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2004-05-19 Cont ID  
Sent By csiegber Date 2004-08-23 Time 14:31 Rev Time 0.33
Received By jwitmer Date   Time   Sent To  
Notes
2004-05-19 00:00:00RELOCATION OF GAZEBO

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2004-05-10 Cont ID  
Sent By jwitmer Date 2004-05-10 Time 10:59 Rev Time 0.25
Received By jwitmer Date 2004-05-10 Time 10:59 Sent To  
Notes
2004-05-10 00:00:00NEW SITE PLAN WITH NEW LOCATION OF THE
 GAZEBO NEXT TO THE TOT LOT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-04-13 Cont ID  
Sent By jwitmer Date 2004-04-13 Time 13:36 Rev Time 1.00
Received By jwitmer Date 2004-04-13 Time 13:36 Sent To  
Notes
2004-04-13 00:00:00BUILDING PROVISO:PROVIDE PRODUCT TESTING
 REPORTS FOR THE 4'-0"X6'-8" DOORS ELEC
 ROOM, WIND AND FIRE 45 MIN

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-03-16 Cont ID  
Sent By mmclean Date 2004-03-17 Time 14:12 Rev Time 2.00
Received By jwitmer Date 2004-03-16 Time 14:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-03-05 Cont ID  
Sent By jwitmer Date 2004-03-05 Time 16:18 Rev Time 2.00
Received By jwitmer Date 2004-03-05 Time 16:18 Sent To  
Notes
2004-03-05 00:00:00PERMIT: 04020440
 790 MALIBU BAY
 BUILDING# 2
 TYPE 1-A BLD
  
 2ND REVIEW
 ACTION: DENIED
  
 MISSING PRODUCT APPROVAL REPORTS:
 A) FRENCH DOORS 45 MIN FIRE RATING
 B) SLIDING GLASS DOORS 45 MIN FIRE RAT
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-02-25 Cont ID  
Sent By csiegber Date 2004-02-12 Time 15:04 Rev Time 3.30
Received By jwitmer Date 2004-02-25 Time 08:14 Sent To  
Notes
2004-02-25 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04020440
 ADD: 790 MALIBU BAY DR BUILD# 2
 CONT: MILLENNIUM GENERAL CONTRACTOR
 TEL: (305)218-7895
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 PERMIT 1ST REVIEW
 ACTION: DENIED
  
 1) PROVIDE A COPY OF THE VARIANCE,
 APPROVED BY THE BOARD OF ADJUSTMENT &
 APPEAL. 1014.1.1
  
 2) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) FRENCH DOORS 45MIN FIRE RATING PLUS
 APPROVAL FOR 140 MPH, RULE 9B-72
 B) SLIDING GLASS DOORS 45 MIN FIRE RAT-
 ING PLUS 140 WIND ZONE, RULE 9B-72.
 C) LOUVER (FUSIBLE LINK) RULE 9B-72
 D) ALL TRUSS ANCHORS THAT ARE TO BE USED
 PROVIDE PROTECT APPROVALS PLUS STATE
 APPROVAL, RULE 9B-72
  
 3) THE REPORT SUBMITTED FORM D. V. FRYE-
 TEC FOR A 45 MINUTE HORIZONTZL SLIDERS
 HAS LIMITATIONS LISTED UNDER THE UL
 LISTING REPORT R 13157. A LIMITTATION
 OF 670 SQ IN PER PANEL WITH A MAXIMUM
 GLASS WIDTH OF 32 IN. AND HEIGHT OF 42IN
 NOTE: 32X42= 1344 SQ IN OVER THE 670
 ALLOWABLE!!
  
 4) INDICATE ON THE FIRE RATED WINDOWS &
 DOORS HOW THEY WILL BE SELF CLOSING OR
 IF THE FIRE RATED PANEL IS TO BE FIXED
 IN PLACE XO, OX.
  
 5) DELETE ALL REFRENCES TO SEMCO TRUSS
 ANCHORS, THIS PRODUCT WAS BOUGHT OUT
 IN 1999. THERE IS NO STATE LISTING FOR
 THESE PRODUCTS!!! SHEET AT.1, A.DT3.
  
 6) REVISION A.DT3 INDICATES THE USE OF
 MONIER ROOF TILE VS PRODUCT APPROVALS
 FOR ENTEGRA ROOF TILE?
  
 7) UNITS 2108, 2208 & 2308 WHERE WALLS
 ARE LESS THAN 15'-0" FROM THE PROPERTY
 LINE WALL OPENINGS WILL BE REQUIRED TO
 BE FIRE RATED 705.1.1.2/ TABLE 600
 1 HR PROTECTED EXT WALL 10'-20' FROM
 PROPERTY LINE.*************************
 ****TABLE 600 I HR PROTECTED TYPE VI BLD
 REQUIRES FOR BEARING OR NON-BEARING
 WALLS 10'-20' FROM PROPERTY LINE TO BE
 1 HR RATED/ OPENING PROTECTIVES 45MIN
 FOR 40% OPENINGS OR LESS. OVER 40% THE
 REMAINDER WOULD NEED TO MEET 1 HR RATING
 THIS BUILD IS UNDER THE 40% PERCENT
 REQUIRING 45 MIN OPENING PROTECTIVES!!!!
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 9 Status P Date 2005-05-18 Cont ID  
Sent By dpalmer Date 2005-05-18 Time 12:33 Rev Time 0.25
Received By dpalmer Date 2005-05-18 Time 12:33 Sent To B
Notes
2005-05-18 00:00:00ELEC REV.OK.
 REV #15 FOR LT POLES SENT TO BLDG.

Review Stop E ELECTRICAL
Rev No 8 Status P Date 2005-02-28 Cont ID  
Sent By dpalmer Date 2005-02-28 Time 17:25 Rev Time 0.25
Received By dpalmer Date 2005-02-28 Time 17:25 Sent To FIRE
Notes
2005-02-28 00:00:00SUBMITTALS FOR ELECTRICAL
 EQUIPMENT/DEVICES , STRAPS, BOXES ETC

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2005-02-28 Cont ID  
Sent By dpalmer Date 2005-02-28 Time 13:37 Rev Time  
Received By dpalmer Date 2005-02-28 Time 13:36 Sent To B
Notes
2005-02-28 00:00:00SITE LIGHTING FIX
 WIND LOADING TO BLDG.

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2005-02-28 Cont ID  
Sent By dpalmer Date 2005-02-28 Time 11:50 Rev Time 0.20
Received By dpalmer Date 2005-02-28 Time 11:49 Sent To B
Notes
2005-02-28 00:00:00*** SITE LIGHTING AND LTPOLES.
 FIXTURES OK, POLES AND WIND-LOADING TO
 BE REVIEWED BY BLDG.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2004-09-22 Cont ID  
Sent By dpalmer Date 2004-09-22 Time 15:13 Rev Time 0.33
Received By dpalmer Date 2004-09-22 Time 15:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-04-27 Cont ID  
Sent By csiegber Date 2004-09-15 Time 09:56 Rev Time 0.33
Received By dpalmer Date 2004-04-27 Time 21:17 Sent To  
Notes
2004-04-27 00:00:00REDLINED THE SAME ITEM,,,AGAIN.
 THERE IS NO EQUIPMENT GROUNDING CONDUCT-
 -OR INSTALLED FROM METER TO MAIN.
 THIS HAS BEEN REDLINED ON ATLEAST 20 SET
 -S OF PLANS. ALL FUTURE PLANS WILL BE
 DENIED UNTIL ALL REDLINES ARE CORRECTED.
 PLEASE SEE 250.6, 250.24

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-04-21 Cont ID  
Sent By dpalmer Date 2004-04-21 Time 19:47 Rev Time 0.33
Received By dpalmer Date 2004-04-21 Time 19:47 Sent To  
Notes
2004-04-21 00:00:00REDLINED NO EQUIPMENT GRNDING COND FROM
 METER TO MAIN. 250.24/250.6
 ROMEX PER 2002 NEC
 STAMPED PLANS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-03-09 Cont ID  
Sent By dpalmer Date 2004-03-09 Time 13:35 Rev Time 0.75
Received By dpalmer Date 2004-03-09 Time 13:35 Sent To  
Notes
2004-03-09 00:00:00PASSED PENDING FIRE REVIEW.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-02-26 Cont ID  
Sent By dpalmer Date 2004-02-26 Time 13:18 Rev Time 1.00
Received By dpalmer Date 2004-02-26 Time 12:51 Sent To  
Notes
2004-02-26 00:00:00REDLINED 250.24 FOR NO EQUIPMENT
 GROUNDING FROM METER TO PANEL.
  
 REDLINED, ANY "LOCK OFF " DEVICES ARE
 TO BE APPOROVED BY CEI.

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2005-04-13 Cont ID  
Sent By nmccray Date 2005-04-13 Time 15:57 Rev Time 0.00
Received By nmccray Date 2005-04-13 Time 15:57 Sent To  
Notes
2005-04-13 00:00:00FIRE ALARM SUBMITTIAL

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2004-04-07 Cont ID  
Sent By mcarsill Date 2004-04-07 Time 14:38 Rev Time 0.00
Received By mcarsill Date 2004-04-07 Time 14:38 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2004-03-12 Cont ID  
Sent By mcarsill Date 2004-03-12 Time 18:43 Rev Time 0.00
Received By mcarsill Date 2004-03-12 Time 18:43 Sent To  
Notes
2004-03-12 00:00:00APPROVED PROVISO:
  
 1) THE FIRE ALARM SYSTEM IS TO BE
 CLASS A OR FULLY ADDRESSABLE NOT CLASS
 B AS INDICATED PER VALUE ENGINEERING
 STATEMENT.
  
 2) THE FIRE EXTINGUISHERS ARE PLANNED
 TO BE MOUNTED ON HOOKS PER VALUE
 ENGINEERING STATEMENT. THESE
 EXTINGUISHERS MIGHT POSSIBLY BE
 STOLEN AND ADDITIONAL COSTS INCURRED.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-02-25 Cont ID  
Sent By mcarsill Date 2004-02-25 Time 13:54 Rev Time 0.00
Received By mcarsill Date 2004-02-25 Time 13:54 Sent To  
Notes
2004-02-25 00:00:001) PLEASE SUBMIT PRODUCT APPROVALS FOR
 THE 45 MINUTE RATED SLIDING GLASS DOORS
 AND THE 45 MINUTE RATED FRENCH DOORS.
 PLEASE PROVIDE SELF-CLOSING DEVICE
 INFORMATION FOR THE 45 MINUTE FIRE
 RATED DOORS.
  
 2) BUILDING ADDRESS REQUIRED ON PROPER
 ELEVATION.
  
 3) ALL NEW FIRE ALARM SYSTEMS SHALL BE
 UL LISTED FOR CENTRAL STATION SERVICE.
  
 4) FIRE ALARM AUDIO AND VISUAL DEVICES
 ARE TO BE INSTALLED IN UNITS DESIGNED
 FOR THE HANDICAP.
  
 5) FDC SHALL BE A SINGLE 2 1/2 NOT A
 SINGLE 1 1/2 AS SHOWN ON THE PLANS.
  
 6) ENTRY DOOR JAMB SHALL BE B LABEL
 NOT C LABEL AS SHOWN ON ENTRY DOOR
 HEAD JAMB DETAIL.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop HIST HISTORICAL
Rev No 1 Status N Date 2005-04-14 Cont ID  
Sent By adarroug Date 2005-04-14 Time 16:04 Rev Time 0.00
Received By adarroug Date 2005-04-14 Time 16:04 Sent To B
Notes
2005-04-14 00:00:00TO "JWITMER"DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 32 Status N Date 2005-04-19 Cont ID  
Sent By adarroug Date 2005-04-19 Time 15:44 Rev Time 0.00
Received By adarroug Date 2005-04-19 Time 15:44 Sent To B
Notes
2005-04-19 00:00:00TO "JWITMER"DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 31 Status N Date 2005-03-25 Cont ID  
Sent By adarroug Date 2005-03-25 Time 15:50 Rev Time 0.00
Received By adarroug Date 2005-03-25 Time 15:50 Sent To B
Notes
2005-03-25 00:00:00TO "JWITMER" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 30 Status N Date 2005-02-14 Cont ID  
Sent By adarroug Date 2005-02-14 Time 13:12 Rev Time 0.00
Received By adarroug Date 2005-02-14 Time 13:12 Sent To B
Notes
2005-02-14 00:00:00TO JWITMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 29 Status N Date 2005-02-14 Cont ID  
Sent By adarroug Date 2005-02-14 Time 13:12 Rev Time 0.00
Received By adarroug Date 2005-02-14 Time 13:12 Sent To B
Notes
2005-02-14 00:00:00TO JWITMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 28 Status N Date 2005-02-14 Cont ID  
Sent By adarroug Date 2005-02-14 Time 13:10 Rev Time 0.00
Received By adarroug Date 2005-02-14 Time 13:10 Sent To B
Notes
2005-02-14 00:00:00TO JWITMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 27 Status N Date 2005-02-11 Cont ID  
Sent By adarroug Date 2005-02-11 Time 12:58 Rev Time 0.00
Received By adarroug Date 2005-02-11 Time 12:58 Sent To B
Notes
2005-02-11 00:00:00TO JWITMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 26 Status N Date 2005-02-11 Cont ID  
Sent By adarroug Date 2005-02-11 Time 12:57 Rev Time 0.00
Received By adarroug Date 2005-02-11 Time 12:57 Sent To B
Notes
2005-02-11 00:00:00TO JWITMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 25 Status N Date 2005-02-11 Cont ID  
Sent By adarroug Date 2005-02-11 Time 11:05 Rev Time 0.00
Received By adarroug Date 2005-02-11 Time 11:05 Sent To B
Notes
2005-02-11 00:00:00TO JWITMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 24 Status N Date 2005-02-09 Cont ID  
Sent By adarroug Date 2005-02-09 Time 15:43 Rev Time 0.00
Received By adarroug Date 2005-02-09 Time 15:43 Sent To B
Notes
2005-02-09 00:00:00TO JWITMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 23 Status N Date 2005-02-09 Cont ID  
Sent By adarroug Date 2005-02-09 Time 15:42 Rev Time 0.00
Received By adarroug Date 2005-02-09 Time 15:42 Sent To B
Notes
2005-02-09 00:00:00TO JWITMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 22 Status N Date 2005-02-09 Cont ID  
Sent By adarroug Date 2005-02-09 Time 15:41 Rev Time 0.00
Received By adarroug Date 2005-02-09 Time 15:41 Sent To B
Notes
2005-02-09 00:00:00TO JWITMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 21 Status N Date 2005-02-09 Cont ID  
Sent By adarroug Date 2005-02-09 Time 15:40 Rev Time 0.00
Received By adarroug Date 2005-02-09 Time 15:40 Sent To B
Notes
2005-02-09 00:00:00TO JWITMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 20 Status N Date 2005-02-09 Cont ID  
Sent By adarroug Date 2005-02-09 Time 15:39 Rev Time 0.00
Received By adarroug Date 2005-02-09 Time 15:39 Sent To B
Notes
2005-02-09 00:00:00TO JWITMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 19 Status N Date 2005-02-09 Cont ID  
Sent By adarroug Date 2005-02-09 Time 15:37 Rev Time 0.00
Received By adarroug Date 2005-02-09 Time 15:37 Sent To B
Notes
2005-02-09 00:00:00TO JWITMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 18 Status N Date 2005-02-09 Cont ID  
Sent By adarroug Date 2005-02-09 Time 15:35 Rev Time 0.00
Received By adarroug Date 2005-02-09 Time 15:35 Sent To B
Notes
2005-02-09 00:00:00TO JWITMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 17 Status N Date 2005-02-08 Cont ID  
Sent By adarroug Date 2005-02-08 Time 11:32 Rev Time 0.00
Received By adarroug Date 2005-02-08 Time 11:32 Sent To I
Notes
2005-02-08 00:00:00TO DPALMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 16 Status N Date 2005-02-08 Cont ID  
Sent By adarroug Date 2005-02-08 Time 11:27 Rev Time 0.00
Received By adarroug Date 2005-02-08 Time 11:27 Sent To B
Notes
2005-02-08 00:00:00TO JWITMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 15 Status N Date 2005-02-08 Cont ID  
Sent By adarroug Date 2005-02-08 Time 11:20 Rev Time 0.00
Received By adarroug Date 2005-02-08 Time 11:20 Sent To B
Notes
2005-02-08 00:00:00TO JWITMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2005-02-08 Cont ID  
Sent By mjacobs Date 2005-02-08 Time 11:18 Rev Time 0.00
Received By mjacobs Date 2005-02-08 Time 11:18 Sent To  
Notes
2005-02-08 00:00:00TO "M/AC" BOX/SUBMITTALS.

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2005-02-08 Cont ID  
Sent By adarroug Date 2005-02-08 Time 11:13 Rev Time 0.00
Received By adarroug Date 2005-02-08 Time 11:11 Sent To P
Notes
2005-02-08 00:00:00TO "P" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2005-02-08 Cont ID  
Sent By adarroug Date 2005-02-08 Time 10:50 Rev Time 0.00
Received By adarroug Date 2005-02-08 Time 10:47 Sent To B
Notes
2005-02-08 00:00:00TO JWITMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2005-02-08 Cont ID  
Sent By adarroug Date 2005-02-08 Time 10:30 Rev Time 0.00
Received By adarroug Date 2005-02-08 Time 10:29 Sent To E
Notes
2005-02-08 00:00:00TO DPALMER DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2004-11-18 Cont ID  
Sent By csiegber Date 2004-11-18 Time 16:36 Rev Time 0.00
Received By csiegber Date 2004-11-18 Time 16:36 Sent To B
Notes
2004-11-18 00:00:00TO JW DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2004-11-10 Cont ID  
Sent By csiegber Date 2004-11-10 Time 13:25 Rev Time 0.00
Received By csiegber Date 2004-11-10 Time 13:25 Sent To B
Notes
2004-11-10 00:00:00TO JW DESK/SUBMITTAL/EXTERIOR METAL
 FRAMING SHOW DRAWINGS

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2004-09-15 Cont ID  
Sent By csiegber Date 2004-09-15 Time 09:55 Rev Time 0.00
Received By csiegber Date 2004-09-15 Time 09:55 Sent To E
Notes
2004-09-15 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2004-08-23 Cont ID  
Sent By csiegber Date 2004-08-23 Time 14:31 Rev Time 0.00
Received By csiegber Date 2004-08-23 Time 14:31 Sent To B
Notes
2004-08-23 00:00:00TO JW DESK/SUBMITTAL/SHOP DRAWS

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-05-13 Cont ID  
Sent By csiegber Date 2004-05-13 Time 08:50 Rev Time 0.00
Received By csiegber Date 2004-05-13 Time 08:49 Sent To  
Notes
2004-05-13 00:00:00TO COMM BD#38

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-04-26 Cont ID  
Sent By csiegber Date 2004-04-26 Time 13:40 Rev Time 0.00
Received By csiegber Date 2004-04-26 Time 13:40 Sent To  
Notes
2004-04-26 00:00:00TO COMM BD#33

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-04-26 Cont ID  
Sent By csiegber Date 2004-04-26 Time 11:29 Rev Time 0.00
Received By csiegber Date 2004-04-26 Time 11:29 Sent To P
Notes
2004-04-26 00:00:00TO KS BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-04-06 Cont ID  
Sent By csiegber Date 2004-04-06 Time 11:07 Rev Time 0.00
Received By csiegber Date 2004-04-06 Time 11:07 Sent To  
Notes
2004-04-06 00:00:00TO COMM BD#8

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-04 Cont ID  
Sent By dpalmer Date 2004-03-04 Time 13:36 Rev Time 0.00
Received By dpalmer Date 2004-03-04 Time 13:36 Sent To  
Notes
2004-03-09 00:00:00TO COMM BOARD #49

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-12 Cont ID  
Sent By csiegber Date 2004-02-12 Time 15:04 Rev Time 0.00
Received By csiegber Date 2004-02-12 Time 15:04 Sent To B
Notes
2004-02-12 00:00:00TO JW DESK/MASTERED

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2004-04-21 Cont ID  
Sent By pkrauss Date 2004-04-21 Time 08:27 Rev Time 0.55
Received By pkrauss Date 2004-04-21 Time 07:25 Sent To  
Notes
2004-04-21 00:00:00PROVISO:
 TOILET EXHAUST TERMINATING AT THE WALL
 SHALL BE SCREENED.BACKDRAFT DAMPER
 SHOULD BE A PART OF THE FAN ASSEMBLY.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-03-05 Cont ID  
Sent By pkrauss Date 2004-03-05 Time 14:24 Rev Time 0.33
Received By pkrauss Date 2004-03-05 Time 14:24 Sent To  
Notes
2004-03-05 00:00:00SEE PROVISO ON PERMIT 04020434

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-02-27 Cont ID  
Sent By pkrauss Date 2004-02-27 Time 14:00 Rev Time 0.55
Received By pkrauss Date 2004-02-27 Time 14:00 Sent To  
Notes
2004-02-27 00:00:00DENIED:
 SEE ATTACHED COMMENTS FROM PERMIT
 04020446

Review Stop P PLUMBING
Rev No 6 Status P Date 2005-02-19 Cont ID  
Sent By jleech Date 2005-02-19 Time 11:17 Rev Time 2.00
Received By jleech Date 2005-02-19 Time 11:17 Sent To  
Notes
2005-02-19 00:00:00SUBMITTAL FOR PLUMBING FIXTURES.

Review Stop P PLUMBING
Rev No 5 Status P Date 2004-05-15 Cont ID  
Sent By kstevens Date 2004-05-15 Time 12:50 Rev Time 0.50
Received By kstevens Date 2004-05-15 Time 12:50 Sent To  
Notes
2004-05-15 00:00:00REVISION OK

Review Stop P PLUMBING
Rev No 4 Status F Date 2004-05-12 Cont ID  
Sent By csiegber Date 2004-04-26 Time 11:29 Rev Time 1.00
Received By kstevens Date 2004-05-12 Time 13:44 Sent To  
Notes
2004-05-12 00:00:00REVISION DENIED
 REFERENCE: FBC-2001 CHAPTER 1
  
 1) SHT PT1A.3 CHANGES TO SANITARY RISER
 P/3 AND TO SANITARY BLDG DRAIN RISER
 DIAGRAM HAVE NOT BEEN CLOUDED AND NO
 REVISION NUMBER SHOWN FOR THESE REVIS-
 IONS.SECTION 104.2.1
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 3 Status F Date 2004-04-19 Cont ID  
Sent By kstevens Date 2004-04-19 Time 11:38 Rev Time 1.50
Received By kstevens Date 2004-04-17 Time 18:57 Sent To  
Notes
2004-04-19 00:00:00REVISION DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SHT P-U1 WATER HAMMER ARRESTOR REQUI-
 RED ON WATER LINE TO REFRIGERATOR. SEC
 604.9 - THIS WAS ON STAMPED/ISSUED PLANS
 BUT WAS DELETED ON REVISION. PLEASE
 CLARIFY.
 2) SHT PT1A.1 CHANGES TO BLDG DRAIN AND
 WATER SERVICE SHOW ON REVISION NUMBER,
 NOR ARE THESE REVISIONS CLOUDED. PLEASE
 CLARIFY.
 3) SHT PT1A.3 CHANGED TO SANITARY BLDG
 RISER AND WATER SERVICE AND RISER HAVE
 NOT BEEN NUMBERED OR CLOUDED. PLEASE
 CLARIFY.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-03-13 Cont ID  
Sent By kstevens Date 2004-03-13 Time 10:09 Rev Time 0.33
Received By kstevens Date 2004-03-13 Time 10:09 Sent To  
Notes
2004-03-13 00:00:00NEW SHEETS

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-02-24 Cont ID  
Sent By kstevens Date 2004-02-24 Time 15:47 Rev Time 1.00
Received By kstevens Date 2004-02-24 Time 13:23 Sent To  
Notes
2004-02-24 00:00:00PASSED/PROVISO
  
 WATER HAMMER ARRESTOR SHALL BE LOCATED
 AT REFRIDGERATOR. SHT P-U1

Review Stop Z ZONING
Rev No 3 Status F Date 2005-05-26 Cont ID  
Sent By dkanning Date 2005-05-26 Time 10:40 Rev Time 0.00
Received By dkanning Date 2005-05-26 Time 10:40 Sent To  
Notes
2005-05-26 00:00:00PHOTOMETRIC READINGS SHALL NOT EXCEED
 0.5 FOOT CANDLES ACROSS PROPERTY LINES.

Review Stop Z ZONING
Rev No 2 Status P Date 2004-05-18 Cont ID  
Sent By gjoyce Date 2004-05-18 Time 12:20 Rev Time 0.10
Received By gjoyce Date 2004-05-18 Time 12:19 Sent To  
Notes
2004-05-18 00:00:00REV PASS

Review Stop Z ZONING
Rev No 1 Status P Date 2004-03-17 Cont ID  
Sent By mmclean Date 2004-03-17 Time 14:12 Rev Time 0.00
Received By mmclean Date 2004-03-17 Time 14:12 Sent To B
Notes
2004-03-17 00:00:00APPROVED BY DAVID KANNING, PLANNER
 659-8031.PROVISO: SIGNED & SEALED
 LANDSCAPE PLANS MUST BE APPROVED PRIOR
 TO LANDSCAPE INSPECTION.