| Plan Review Stops For Permit 04020394 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-07-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-07-12 |
Time |
09:13 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2004-07-12 |
Time |
09:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-07 |
Time |
16:42 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
2004-06-15 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2004-06-15 00:00:00 | DENIED | | | | | | 1) THE NOC SUBMITTED DOES NOT COMPLY | | | WITH FS 713.13. PROPERTY NOT IDENTIFIED. | | | SEE ATTACHED. | | | | | | 2) PRIVACY WALL EXCEEDS MAXIMUM HEIGHT | | | ALLOWED BY ZONING. CHECK WITH THE ZONING | | | DEPARTMENT. A SEPARATE PERMIT WILL BE | | | REQUIRED. REVISE SHEETS A1 AND A5. | | | | | | 3) THE PRODUCT APPROVAL DRAWINGS FOR THE | | | CLOPAY GARAGE DOORS DOES NOT CONCUR WITH | | | PLANS. THE WIDTH AND PRESSURES EXCEED | | | LIMITS ON PROD. APPROVAL DRAWINGS. | | | | | | 4) THERE ARE NO CASEMENT WINDOWS SHOWN | | | ON THE ARCHITECTURAL PLANS. REMOVE THIS | | | PRODUCT APPROVAL FROM SUBMITTAL. | | | | | | 5) NO STATE OF FL PRODUCT APPROVAL #S | | | WERE SUBMITTED FOR THE FOLLOWING ITEMS: | | | - FRENCH DOORS WITH SIDELITES | | | - FRENCH DOORS | | | - SINGLE HUNG WINDOWS | | | - STRUCTURAL MULLIONS | | | | | | 6) NO INSTALLATION INSTRUCTIONS WERE | | | SUBMITTED FOR FL 328 SLIDING GLASS DOORS | | | | | | 7) THE NOA NUMBER FOR THE PW 701 FIXED | | | WINDOWS DOES NOT MATCH THE NOA #S LISTED | | | ON THE FL 243 STATE PROD. APP. | | | | | | 8) SUBMIT STATE PRODUCT APPROVAL FOR THE | | | WINDOWS IN THE BREAKFAST ROOM, BAR AND | | | MASTER BATH. INDICATE WHAT TYPE OF | | | ASSEMBLY WILL BE INSTALLED IN THESE | | | AREAS (STOREFRONTS, BUTT GLASS, ETC.). | | | | | | 9) THE PRODUCT APPROVALS SUBMITTED FOR | | | THE MULLIONS WILL NOT WORK BETWEEN THE | | | WINDOWS AT THE LIVING ROOM OR THE 16'SGD | | | AND THE TRANSOM AT THE FAMILY ROOM. | | | SUBMIT APPROPRIATE PRODUCT APPROVAL OR | | | ADD LINTEL BETWEEN. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-05-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-06-12 |
Time |
11:10 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2004-05-20 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2004-05-20 00:00:00 | DENIED | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) OWNER OR AGENT IS REQUIRED TO SIGN | | | AND DATE THE ENERGY CALC. FORM. | | | | | | 3)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. | | | IN ADDITION TO THE STATE PRODUCT | | | APPROVAL COVER SHEET (WITH FL#), THE | | | CORRESPONDING EVALUATION REPORT, NOA, | | | TEST REPORT,ETC. CONTAINING INSTALLATION | | | INSTRUCTIONS, LIMITATIONS, ETC. IS | | | REQUIRED TO BE SUBMITTED FOR EACH ITEM. | | | | | | 4) CLARIFY WHAT SYSTEM IS BEING USED FOR | | | THE WINDOWS ON ANGLES AT THE BREAKFAST | | | ROOM, BAR AND MASTER BATH. | | | | | | IF YOU HAVE QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-04-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-05-17 |
Time |
15:28 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2004-04-22 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2004-04-22 00:00:00 | DENIED | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) THE A/C AREA LISTED ON THE PLANS IS | | | 5783 SQFT AND THE ENERGY CALC. FORM | | | LISTS 5779 SQFT. PLEASE CORRECT. | | | | | | 3) IN ADDITION TO THE STATE PRODUCT | | | APPROVAL COVER SHEET, THE CORRESPONDING | | | EVALUATION REPORT, NOA, TEST REPORT, ETC | | | CONTAINING INSTALLATION INSTRUCTIONS, | | | DESIGN PRESSURES, LIMITATIONS, ETC. IS | | | REQUIRED TO BE SUBMITTED. | | | | | | 4) SUBMIT STATE PRODUCT APPROVAL WITH | | | INSTALLATION INSTRUCTIONS, LIMITS, ETC. | | | FOR THE FOLLOWING: | | | - SINGLE HUNG WINDOWS | | | - OUTSWING GLAZED DOORS | | | - OUTSWING DOUBLE DOORS WITH SIDELITES | | | - ARCHED TOP FIXED GLASS WINDOWS | | | (DESIGNER SHAPES) | | | - RECTANGULAR FIXED GLASS WINDOWS | | | - STRUCTURAL MULLIONS | | | - STOREFRONT WINDOWS AT BREAKFAST ROOM, | | | BAR AND MASTER BATH | | | - ALL EXTERIOR WINDOWS AND DOORS USED IN | | | THIS STRUCTURE | | | | | | 5) SUBMIT ADDITIONAL COPIES OF THE BBQ | | | AND HOOD INFORMATION THAT WAS SUBMITTED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-21 |
Time |
09:02 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
2004-03-22 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2004-03-22 00:00:00 | DENIED | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) SPECIFY ON PLANS THAT WIRE MESH IN | | | SLAB IS TO BE SUPPORTED ON APPROVED | | | MATERIAL AT 3'O.C. PER FBC 1909.3. | | | | | | 4) INDICATE THE APPLICABLE ENCLOSURE | | | CLASSIFICATION AND,IF DESIGNING BY ASCE | | | 7-98, THE INTERNAL PRESSURE COEFFICENT | | | PER FBC 1606.1.7. | | | | | | 5) SPECIFY THE SIZE OF THE ATTIC | | | ACCESSES ON THE PLANS. THE MINIMUM SIZE | | | IS 20 X 36 INCHES PER FBC 2309.6. | | | | | | 6) THE A/C AREA LISTED ON THE PLANS DOES | | | NOT MATCH THE CONDITIONED AREA ON THE | | | ENERGY CALC. FORM. PLEASE CORRECT. | | | | | | 7) SPECIFY THE AREA OF THE COVERED | | | PORCHES AND GARAGE ON THE AREA CALCS. ON | | | SHEET A3. | | | | | | 8) SPECIFY ON THE PLANS THAT THE DOOR TO | | | THE GARAGE FROM THE CONDITIONED SPACE IS | | | INSULATED OR SOLID CORE AS REQUIRED BY | | | FBC 13-603. | | | | | | 9) REVISE THE ROOF SHEATHING FASTENING | | | SCHEDULE ON A8. FOR A MEAN ROOF HEIGHT | | | LESS THAN 25'FASTENERS ARE REQUIRED TO | | | BE SPACED 4"OC AT THE EDGES AND 6"OC | | | INTERMEDIATE IN ZONE 3 AND FOR A MEAN | | | ROOF HEIGHT 25'TO 35' FASTENERS ARE | | | REQUIRED TO BE 8D RING SHANK NAILS | | | SPACED 4"OC EDGES AND 6"OC INTERMEDIATE | | | IN ZONE 3. SEE CITY AMENDMENTS TO FBC | | | TABLE 2306.1. | | | | | | 10) IN THE TRUSS ANCHOR SCHEDULE ON A8 | | | THE (I) HETA 16 W/10- 10D X 1-1/2 NAILS | | | IS LISTED WITH UPLIFT OF 810#. THE | | | SIMPSON CATALOG LISTS 1810#. PLEASE | | | CORRECT. | | | | | | 11) SOME OF THE TRUSSES ON THE TRUSS | | | LAYOUT ON A7 DO NOT HAVE AN ANCHOR | | | SPECIFIED. PLEASE SPECIFY ANCHORS FOR | | | ALL TRUSS TO WALL CONNECTIONS. | | | | | | 12) PROVIDE A DETAIL OF THE 2X4 FRAME | | | WALLS AT THE TOWER. SPECIFY THE SPACING | | | OF THE 2X4S AND STRAPPING REQUIRED TO | | | ACHIEVE A CONTINOUS LOAD PATH FROM THE | | | TOWER ROOF TO THE GIRDER TRUSSES BELOW. | | | | | | 13) PROVIDE DETAILS AND PRODUCT APPROVAL | | | FOR THE ANGLED FIXED GLASS WINDOW | | | ASSEMBLIES AT THE MASTER BATH AND | | | BREAKFAST/BAR AREA. | | | | | | 14) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. | | | | | | 15) THE DRAWING SUBMITTED FOR THE CLOPAY | | | GARAGE DOORS ARE LIMITED TO A MAXIMUM | | | WIDTH OF 9'. THE DOORS ON THE PLANS ARE | | | 10' WIDE. SUBMIT APPROPRIATE DRAWINGS. | | | | | | 16) SUBMIT MANUFACTURER'S SPECIFICATIONS | | | AND UL LISTING FOR THE GAS BBQ AND HOOD. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2005-06-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-29 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2005-06-29 00:00:00 | NEEDS NEW SHEETS, NO REVIEW DONE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-21 |
Time |
08:08 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-06-21 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2005-06-21 00:00:00 | ************* UNSAT ************* | | | | | | | | | 1)NOTE: PLEASE SHOW ALL SERVICE | | | EQUIPMENT/ PANELS ON PLANS. PLEASE | | | CORRELATE PANELS WITH RISER. | | | MISSING D, E ETC. | | | 215.5 | | | | | | | | | 2)NOTE: PLEASELOADS SHOWN ON MAIN | | | PANEL SCHEDULES. PLEASE SEE SOME ARE NOT | | | CLEAR AND NEED TO DARKER. | | | | | | | | | 3)NOTE: PLEASE SEE MISSING KITCHEN | | | COUTERSPACE RECEPT PER 210.52C1 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-06-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-15 |
Time |
17:41 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-06-15 |
Time |
17:37 |
Sent To |
|
|
| Notes |
| 2005-06-15 00:00:00 | ************* UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE PLANS SUBMITTED MUST | | | BE REVISED BY THE ARCH OF RECORD. PLANS | | | MUST BE SIGNED, DATED AND SEALED BY | | | ARCH. FS 481.221 | | | PLANS MUST ALL TITLE BLOCKS AS REQUIRED | | | UDNER FAC 61G1-16.004. | | | | | | 2)NOTE: PLEASE SHOW ALL SERVICE | | | EQUIPMENT/ PANELS ON PLANS. | | | MISSING D, E ETC. | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE 230.72. 225.24 FOR | | | GROUPING OF DISCONNECTING MEANS. | | | PLEASE SEE GEN SUB PANEL APPEARS TO BE | | | SHOWN AS MLO, WHERE ARE MCB IS REQUIRED. | | | | | | 4)NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | | ON PANEL SCHEDULES AND FOR SERVICE WHICH | | | MEET 2002 NEC 220.31. PLEASE SEE THE | | | SAME LOAD OF 41 A'S IS INDICATED AND | | | SHOWN ON EACH PANEL LOAD CALC.??? | | | 215.5 | | | | | | 5)NOTE: PLEASE SEE EQUIPMENT GROUNDING | | | CONDUCTORS SHOWN BEFORE THE FIRST MEANS | | | OF DISCONNECT. PLEASE SEE 250.6,250.24 | | | THESE ARE ONLY INSTALLED AFTER THE FIRST | | | MEANS OF DISCONNECT. | | | | | | 6)NOTE: PLEASE SEE MISSING KITCHEN | | | COUTERSPACE RECEPT PER 210.52C1 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-04-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-18 |
Time |
08:17 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-04-18 |
Time |
08:17 |
Sent To |
P |
|
| Notes |
| 2004-04-18 00:00:00 | CORRECTIONS MADE, PLANS STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-02-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-16 |
Time |
15:42 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-02-23 |
Time |
12:33 |
Sent To |
M |
|
| Notes |
| 2004-02-23 00:00:00 | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE FEEDER FOR PANEL "C" IS #3 ON | | | THERISER.IT IS LISTED AS #6 ON PANEL | | | SCHEDULE "B". PLEASE CORRELATE | | | | | | 2} PLEASE NOTE THE #6 CONDUCTORS WITH | | | 100 AMP OCP IS IN VIOLATION OF | | | 310.16,CKTS 20 & 22, PANEL "B". | | | | | | 3} THE KW RATING FOR PANEL "C" IS LISTED | | | @ 20KW IN PANEL "B" AND 18 KW ON PANEL | | | "C".PLEASE CORRELATE. | | | | | | 4} NOTE THAT PANEL "B" READS "VA" | | | INSTEAD OF "KW". | | | | | | 5} THE REFRIGERATOR IN PANEL "A" IS | | | LISTED @ 3KW. THAT WUOLD BE 25 AMPS ON | | | THE 20 BREAKER THAT IS SHOWN. | | | | | | 6} THE HEAT STRIPS ON THE MECHANICAL | | | PLAN THE ONES ON THE ELECTRICAL PLAN | | | ARE NOT THE SAME. PLEASE CORRELATE AND | | | RECALCULATE THE LOAD ACCORDINGLY. | | | | | | 7} PLEASE INDICATE THE LOCATION OF "C" | | | PANEL. | | | | | | 8} THE DISCONNECT FOR A/C #4 DOES NOT | | | COMPLY WITH 110.26 FOR CLEARANCES. | | | | | | 9} PLEASE NOTE THE SPA RECEPTACLE MUST | | | BE GFI PER 680.43(A)(1). | | | | | | 10} PLEASE NOTE THAT THE FIRM LICENSE | | | NUMBER MUST BE ADDED TO THE TITLE | | | BLOCK TO COMPLY WITH 61G1-16.004(2) FAC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2005-06-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-24 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-24 |
Time |
09:51 |
Sent To |
P |
|
| Notes |
| 2005-06-24 00:00:00 | TO "P" BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2005-06-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-24 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-24 |
Time |
09:49 |
Sent To |
E |
|
| Notes |
| 2005-06-24 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-06-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-17 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-17 |
Time |
11:48 |
Sent To |
E |
|
| Notes |
| 2005-06-17 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-06-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-10 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-10 |
Time |
11:42 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-08 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-08 |
Time |
09:35 |
Sent To |
E |
|
| Notes |
| 2005-06-08 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-05-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-10 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-10 |
Time |
15:40 |
Sent To |
P |
|
| Notes |
| 2005-05-10 00:00:00 | TO "KSTEVENS" BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-04-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-12 |
Time |
17:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-12 |
Time |
17:23 |
Sent To |
B |
|
| Notes |
| 2005-04-12 00:00:00 | TO "RMCDOUGAL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-07-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-07 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-07 |
Time |
16:42 |
Sent To |
B |
|
| Notes |
| 2004-07-07 00:00:00 | TO RM DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-06-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-09 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-09 |
Time |
10:38 |
Sent To |
P |
|
| Notes |
| 2004-06-09 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-05-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-03 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-03 |
Time |
15:33 |
Sent To |
M |
|
| Notes |
| 2004-05-03 00:00:00 | TO PK DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-04-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-12 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-12 |
Time |
12:01 |
Sent To |
M |
|
| Notes |
| 2004-04-12 00:00:00 | TO PK BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-13 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-02-11 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2004-02-13 00:00:00 | TO SFD RACK/E | | 2004-02-11 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-05-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-05-13 |
Time |
14:16 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-05-13 |
Time |
13:47 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-04-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-03 |
Time |
15:33 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-04-16 |
Time |
15:13 |
Sent To |
E |
|
| Notes |
| 2004-04-16 00:00:00 | DENIED: | | | 2ND REQUEST: | | | 1.DUCT SIZES ARE NOT INDICATED ON | | | PLAN.PLEASE REVISE PLANS TO REFLECT | | | DUCT SIZE. | | | | | | 2.RETURN AIR SHALL BE EQUAL TO THE | | | SUPPLY AIR TO THAT AREA PER 2001 FBC(M) | | | 601.4. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-02-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-12 |
Time |
12:01 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2004-02-26 |
Time |
18:55 |
Sent To |
B |
|
| Notes |
| 2004-02-26 00:00:00 | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | AND RESUBMIT PLANS FOR REVIEW | | | 1) REFER TO SECTION 601.4 BALANCED | | | RETURN AIR. | | | 2) SOME OF THE DUCT SIZES ARE NOT MARKED | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6734 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2005-06-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-28 |
Time |
11:26 |
Rev Time |
0.63 |
| Received By |
kstevens |
Date |
2005-06-28 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2005-06-28 00:00:00 | REVISION OK - SANT. RISER DIAGRAM - SEE | | | RED LINE CORRECTIONS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2005-06-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-27 |
Time |
16:41 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2005-06-27 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2005-06-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | A. SANITARY RISER DIAGRAM DOES NOT MEET | | | CODE REQUIREMENTS, NOR DOES IT REFLECT | | | THE FLOOR PLAN. CORRECT THE FOLLOWING: | | | 1. TRAPS ARE REQUIRED ON THE TUB & | | | SHOWER BATH #4. SECTION 1002.1. | | | 2. RISER SHOWS A TUB AND FLOOR PLAN | | | SHOWS A SHOWER. SECTION 104.2.1. | | | 3. THE WASH MACHINE SHALL CONNECT | | | DOWNSTREAM OF THE LAUNDRY SINK ON THE | | | STACK, AS THE VERTICAL DRAIN PIPE | | | CONNECTING THE TWO FIXTURE DRAINS SHALL | | | BE CONSIDERED THE VENT FOR THE LOWER | | | FIXTURE. SECTION 908.3 | | | 4. THE WASH MACHINE REQUIRES A MIN. 2' | | | STANDPIPE. SECTION 1002.1. | | | 5. THE CLEANOUT FOR THE WASHMACHINE | | | SHALL BE LOCATED 4' ABOVE THE FLOOR. | | | SECTION 708.10. | | | 6. THE WATER CLOSET AND THE BIDET IN | | | THE MASTER BATH ARE NOT VENTED. SECTION | | | 901.2.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-06-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-06-12 |
Time |
11:10 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2004-06-12 |
Time |
11:10 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2004-05-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-09 |
Time |
10:38 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-05-17 |
Time |
15:17 |
Sent To |
B |
|
| Notes |
| 2004-05-17 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) NEW SANITARY RISER DIAGRAM DOES NOT | | | MEET CODE REQUIREMENTS | | | A) POWDER ROOM WATER CLOSET IS NOT | | | VENTED. | | | B) SINK IN GARAGE SHALL NOT DRAIN THRU | | | THE BATHROOM FIXTURES. SINK SHALL DIS- | | | CHARGE DOWNSTREAM OF THE BATHROOM FIX- | | | TURES. SECTION 909.1 | | | C) WASHMACHINE AND LAUNDRY SINK DO NOT | | | REFLECT THE FLOOR PLAN. WASH MACHINE IS | | | ON THE RIGHT SIDE AND LAUNDRY SINK IS ON | | | THE LEFT SIDE OF THE STACK. 104.2.1 | | | D) BATH #2 SHOWS TUB ON RISER AND SHOWS | | | A SHOWER ON THE FLOOR PLAN. CLARIFY. | | | E) SIZE ALL PIPES IN BATH #4, 3" REQ'D | | | UP TO SHOWER. TABLE 909.3 | | | F) SEE PIPE SIZING FOR BIDET AND SHOWER | | | IN MASTER BATH. MINIMUM 2" REQUIRED. | | | TABLE 709.1 | | | *********SEE RED LINE CORRECTIONS******* | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-04-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-05-13 |
Time |
14:16 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-04-20 |
Time |
15:15 |
Sent To |
B |
|
| Notes |
| 2004-04-21 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHT A-1 SANITARY RISER DIAGRAM DOES | | | NOT REFLECT THE FLOOR PLAN NOR DOES IT | | | MEET CODE REQUIREMENTS. SECTION 104.2.1 | | | A) VEGETABLE SINK NOT SHOWN ON RISER. | | | B) WASH MACHINE SHALL NOT CONNECT TO | | | STACK ABOVE THE LAUNDRY SINK. | | | C) BBQ SINK IDENTIFIED AS A LAV. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-02-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-02-19 |
Time |
10:50 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-02-19 |
Time |
10:50 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-02-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-13 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-02-13 |
Time |
15:12 |
Sent To |
I |
|
| Notes |
|
|