| Plan Review Stops For Permit 04020363 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2004-06-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-06-29 |
Time |
16:33 |
Rev Time |
0.95 |
| Received By |
jwitmer |
Date |
2004-06-29 |
Time |
16:33 |
Sent To |
PC |
|
| Notes |
| 2004-06-29 00:00:00 | TILT WALL REINFORCING PLAN | | | SRUCTURAL STEEL, JOIST & DECKING OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-06-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
16:38 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2004-06-24 |
Time |
07:53 |
Sent To |
PC |
|
| Notes |
| 2004-06-24 00:00:00 | WINDOW & DOOR SHOP DRAWINGS, TILT WALL | | | SHOP DRAWINGS AND CALSOK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-05-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-16 |
Time |
15:53 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2004-05-18 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2004-05-17 00:00:00 | IMPACT FEES ARE PAID |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-05-14 |
Time |
09:19 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2004-05-14 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2004-05-14 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04020363 | | | ADD: 1720 CENTREPARK DR E | | | CONT: THE WEITZ CO | | | TEL: (561)719-0150 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | ACTION: DENIED | | | | | | BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-04-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-04-23 |
Time |
10:45 |
Rev Time |
2.50 |
| Received By |
jwitmer |
Date |
2004-04-23 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2004-04-23 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04020363 | | | ADD: 1720 CENTREPARK DRIVE E | | | CONT: THE WEITZ CO | | | TEL: (561)719-0150 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) FBC* 105.3RESIDENT INSPECTOR. | | | SUBMIT INSPECTOR RESUME' AND LICENSE | | | DOCUMENTS TO HAROLD PISKURA, DIRECTOR OF | | | THE RESIDENT INSPECTOR PROGRAM.A | | | RESIDENT INSPECTOR PROGRAM IS REQUIRED, | | | ON THIS PROJECT, DUE TO: | | | - BUILDINGS/ADDITIONS OF TYPE I OR II | | | CONSTRUCTION | | | - ANY MAJOR STRUCTURAL ALTERATIONS | | | - STRUCTURES IN WHICH THE CONCRETE | | | DESIGN IS BASED ON COMPRESSIVE | | | STRENGTH (F'C) IN EXCESS OF 3000 PSI | | | - PILE DRIVING | | | - BUILDINGS OVER 20,000 SQFT IN AREA | | | - BUILDINGS OVER 2 STORIES IN HEIGHT | | | - BUILDING/STRUCTURES OF UNUSUAL DESIGN | | | OR METHODS OF CONSTRUCTION | | | | | | 2) THREE SETS OF ALL DOCUMENTS WILL BE | | | REQUIRED FOR THE RESIDENT INSPECTOR | | | PROGRAM. | | | | | | 3) BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | JIM WITMER | | | BUILDING PLAN REVIEW | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-03-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-03-08 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2004-03-08 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2004-03-08 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04020363 | | | ADD: 1720 CENTERPARK DRIVE EAST | | | CONT: THE WEITZ CO | | | TEL: (561)686-5511 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) PROVIDE FLOOD ZONE ELEVATION | | | CERTIFICATE FOR NEW CONSTRUTION WITH | | | BASE FLOOD ELEVATION, CITY CODE | | | REQUIRESAN ADDITIONAL 6". LOCATED IN A | | | "A9" | | | MINIMUM ELEVATION REQUIRED IS 13'-6". | | | | | | 3) FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | WHERE THE BEARING CAPACITY OF THE SOIL | | | IS NOT DEFINITEY KNOWN, OR IS IN | | | QUESTIONTHE BUILDING OFFICIAL MAY | | | REQUIRE EXPLORATIONS, TEST OR OTHER | | | ADEQUATE PROOF AS TO THE PERMISSIBLE | | | SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | | NICALREPORT FROM A DESIGN PROFESSIONAL | | | PROPERLY LICENSED IN THE STATE OF | | | FLORIDA. | | | | | | 4) TABLE 500 ISSUES THE AREA INCREASE | | | TAKEN FOR FIRE SPRINKLERED BUILDINGS, | | | PROVIDE FIRESPRINKLER PLANS BEFORE ISSUA | | | NCE OF PERMIT. | | | | | | 5) PLANS DO NOT INDICATE THE OPEN WORK | | | STATIONS, INDICATE LOCATION OF WORK | | | STATIONS, EGRESS AISLES AND THE COMMON | | | PATH FROM ROOM 114, NOT TO EXCEED 75'. | | | | | | 6) 11-4.30.1 SIGNAGE REQUIRED TO BE | | | ACCESSIBLE BY 11-4.1 SHALL COMPLY WITH | | | APPLICABLE PROVISIONS OF 11-4.30. | | | | | | 7) THE EXITS AT 103-B & 136-B BOTH ARE | | | PART OF REQUIRED EXITS, AND ACCESSIBLE | | | EXITS REQUIRED TO GO TO THE PUBLIC WAY | | | MEANS OF EGRESS. DEFINTIONS CHAP2, CHAP- | | | TER 11-3.5 DEFINITIONS. SIDEWALKS TO BE | | | A MINIMUM OF 44" REQUIRED MEANS OF | | | EGRESS. | | | | | | 8)1204.2 SURROUNDING MATERIALS; | | | THE WALLS & FLOORS OF ALL PUBLIC REST- | | | ROOMS SHALL BE LINED WITH NONABSORBANT | | | MATERIALS TO A HEIGTH OF 4'-0" ABOVE THE | | | FLOOR. | | | | | | 9)1511.7 ROOF MOUNTED MECHANICAL UNIT | | | S SHALL BE MOUNTED ON CURBS RAISED A | | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | | HEIGHT IN ACCORDANCE WITH TABLE 1511.7. | | | MECH. 301.13 WIND RESISTANCE | | | MECHANICAL EQUIPMENT, APPLIANCES AND SUP | | | PORTS THAT ARE EXPOSED TO WIND SHALL BE | | | DESIGNED AND INSTALLED TO RESIST THE | | | WIND PRESSURES ON THE EQUIPMENT & THE | | | SUPPORTS AS DETERMINED IN ACCORDANCE | | | WITH THE FL BLD CODE. THIS MAY BE ACCOMP | | | LISHED BY DESIGN OR BY APPLICATION OF | | | SECTION 301.13.1. | | | SHEET S-5 A/C SUPPORT DETAILS DO NOT | | | INDICATE THE ATTACHMENT OF THE CURB, | | | 8" IN HEIGHT ABOVE THE ROOF DECK. | | | | | | 10)FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS | | | B) MULLIONS | | | C) EXTERIOR DOORS | | | D) ROOFING ASSEMBLIES | | | E) STORM SHUTTERS IF IMPACT GLAZING | | | NOT PROVIDED. | | | ***********IMPORTANT***************** | | | 11) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 12)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | JIM WITMER | | | BUILDING PLAN REVIEW | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-05-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-11 |
Time |
16:15 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-05-11 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2004-05-11 00:00:00 | SIGNED AND SEALED SHEETS BROUGHT IN | | | STAMPED 3RD SET. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-05-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-08 |
Time |
19:03 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-05-08 |
Time |
19:03 |
Sent To |
|
|
| Notes |
| 2004-05-08 00:00:00 | ******************* UNSAT *********** | | | | | | 1)NOTE: PLEASE SEE NEW 3RD SET SUBMITTED | | | WHICH IS REQUIRED FOR THRESHOLD JOB. | | | ELEC IS MISSING MANY SHEETS THAT ARE | | | NOT SIGNED, DATED OR SEALED AS REQ'D | | | UNDER FAC 61G15-23.002/ FS 471.025 | | | | | | **ALL OLD/VOIDED SHEETS MUST BE REMOVED | | | TO MAKE 3 CLEAN SETS FOR REVIEW AND | | | STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-04-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-16 |
Time |
18:14 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-04-16 |
Time |
18:14 |
Sent To |
|
|
| Notes |
| 2004-04-16 00:00:00 | | | | WROTE NAME AND LICENSE # ON E-SHEETS/ | | | TITLE BLOCK FOR RA KAMM. | | | 61G15-23.002 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-02-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-02-20 |
Time |
13:12 |
Rev Time |
3.00 |
| Received By |
dpalmer |
Date |
2004-02-20 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2004-02-20 00:00:00 | ***************** UNSAT ************** | | | | | | 1)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | | AT 125%. 215.3,230.42 ETC. | | | | | | 2)NOTE: PLEASE SHOW LOCATION OF MAIN | | | ON THE OUTSIDE OF BLDG, ON E3.1 | | | | | | 3)NOTE: PLANS SHOWS ACCESS INTO ELECTR- | | | -CAL THROUGH JAN. CLOSET. PLEASE SEE | | | THIS WILL NOT BE PERMITTED. MET WITH | | | FIRE MARSHAL MIKE CARSILLO AND NOTES | | | ON ELECTRICAL NOTES. LS 101, NEC 110.26 | | | ETC. | | | | | | 4)NOTE: PLEASE LABEL EACH OF THE 400A | | | DISC'S IN 1200A MLO. | | | | | | 5)NOTE: PLEASE SEE THAT SERVICE DISC | | | MEANS FOR TENANT "B" IS LOCATED INSIDE | | | PRIMARY TENANT SPACE. PLEASE VERIFY | | | IF THIS TENANT'B' WILL PART OF THE SAME | | | OFFICE.? | | | TENANT "B" MUST HAVE ACCESS TO THEIR | | | DISC MEANS W/OUT GOING INTO ANOTHERS | | | SPACE. | | | A COMMON ELECTRICAL RM MAY BE AN ANSWER? | | | AS SHOWN, IF ONE OFFICE IS CLOSED, OTHER | | | TENANT WILL NOT HAVE ACCESS.? | | | | | | PLEASE SEE FIRE REVIEW COMMENTS AS WILL | | | HAVE AN AFFECT ON ELECTRICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2004-04-19 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-04-19 |
Time |
10:11 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-04-19 |
Time |
10:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2004-02-17 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-02-17 |
Time |
15:22 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-02-17 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2004-02-17 00:00:00 | FAILED: | | | 1. PLEASE SUBMIT CIVIL PLANS FOR OUR | | | REVIEW AND APPROVAL, NOTE THAT SITE MUST | | | BE DESIGNED FOR DRAINAGE PER CITY OF | | | WPB CRITERIA AND REQIUREMENTS. | | | 2. PLEASE SUBMIT STORM WATER CALCULATION | | | AND INCLUDE PERVIOUS AND IMPERVIOUS AREA | | | FOR ENTIRE SITE. | | | 3. PLEASE INCLUDE POLLUTION PREVENTION | | | PLAN IN CIVIL . | | | 4. PLEASE SUBMIT CIVIL PLANS ONLY TO THE | | | PUBLIC UTILITIES FOR ALL THE CONNECTIONS | | | AND LOCATION OF BACKFLOWS,METERS,ETC. | | | ATT; JIM SPEACH, 659-8040 | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-05-11 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-05-11 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-05-11 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2004-05-11 00:00:00 | ********PROVISO************************* | | | 1) THE LETTER DATED APRIL 28, 2004 IN | | | RESPONSE TO PLAN REVIEW COMMENTS FOR | | | PERMIT #04020363 DID NOT ADDRESS THE | | | PREVIOUS PLAN REVIEW COMMENTS BY FIRE. | | | | | | 2) PLEASE MAKE THE FOLLOWING CORRECTIONS | | | TO NOTE #17 AND #19 ON SHEET FA0.1. | | | | | | * NOTE #17 HVAC DUCT SMOKE DETECTOR | | | SHALL BE CONNECTED TO THE FIRE ALARM | | | CONTROL PANEL AND SHALL INTIATE A | | | GENERAL FIRE ALARM. | | | | | | * NOTE #19 ALL FIRE ALARM CIRCUITS SHALL | | | BE CLASS"A" OR FULLY ADDRESSABLE. | | | | | | 3) ALL NEW RAMPS AND STAIRS SHALL BE | | | PROVIDED WITH HANDRAILS ON BOTH SIDES. | | | | | | 4) FIRE SPRINKLER DRAWINGS ARE TO BE | | | SUBMITTED UNDER SEPARATE COVER AND UNDER | | | SEPARATE PERMIT APPLICATION. | | | | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
N |
Date |
2004-05-17 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-04-15 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2004-04-15 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2004-04-15 00:00:00 | 1) COULD NOT LOCATE ANY CHANGES TO | | | SHEETS FAO.1. FIRE ALARM SYSTEM SHALL | | | BE CLASS A OR FULLY ADDRESSABLE. | | | | | | 2) ALL NEW RAMPS AND STAIRS SHALL | | | BE PROVIDED WITH HANDRAILS ON BOTH | | | SIDES. | | | | | | 3) FIRE SPRINKLER DRAWINGS ARE TO BE | | | SUBMITTED UNDER SEPARATE COVER AND | | | UNDER SEPARATE PERMIT. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-02-13 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-02-13 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2004-02-13 00:00:00 | 1) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR THE FIRE ALARM SYSTEM. FIRE | | | ALARM SYSTEM SHALL BE UL LISTED FOR | | | CENTRAL STATION SERVICE. A CERTIFICATE | | | FOR CENTRAL STATION SERVICE SHALL | | | BE PROVIDED AT TIME OF FIRE ALARM | | | PERMIT APPLICATION. | | | | | | 2) NOTES ON PAGE FAO.1. ARE INCORRECT. | | | NOTES 17 AND 18 ARE TO BE REVISED. | | | | | | 3) A KNOX-BOX WILL BE REQUIRED. | | | | | | 4) NO EXIT SIGN PRESENT DIRECTLY IN | | | FRONT OF LOUNGE DOOR TO DIRECTING | | | PERSON TO THE LOUNGE EXTERIOR EXIT. | | | | | | 5) BUILDING ADDRESS NOT SHOWN ON | | | ELEVATION DRAWING. BUILDING ADDRESS | | | SHALL BE A MINIMUM OF 6" HIGH. | | | | | | 6) TENANT SPACE B IS TO BE FIRE | | | SPRINKLER PROTECTED WHEN SPACE A IS. | | | | | | 7) NO FIRE SPRINKLER PLANS PROVIDED. | | | | | | 8) PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATION FOR WALLS AND CEILINGS. | | | | | | 9) PLEASE PROVIDE A LIFE SAFETY | | | PLAN FOR REVIEW. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-25 |
Time |
16:38 |
Sent To |
B |
|
| Notes |
| 2004-06-25 00:00:00 | TO JW DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-06-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-16 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-16 |
Time |
15:53 |
Sent To |
B |
|
| Notes |
| 2004-06-16 00:00:00 | TO JW DESK/2 SUBMITTALS/ | | | STOREFRONT/WINDOW SHOP DRAWINGS W/PA | | | TILT-PANEL DRAWINGS /CALCS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-06-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-11 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-11 |
Time |
08:47 |
Sent To |
B |
|
| Notes |
| 2004-06-11 00:00:00 | CHANGE OF ONM&J INSPECTOR TO DONALD | | | WILLIAMS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-04 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-04 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2004-05-04 00:00:00 | TO COMM BD#/PKG & 1 ROLL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-03-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-03-30 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-03-30 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2004-03-30 00:00:00 | TO COMMERCIAL BD.#43 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-20 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-11 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2004-02-11 00:00:00 | TO COMM BD#34 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-04-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-06 |
Time |
13:07 |
Rev Time |
1.10 |
| Received By |
pkrauss |
Date |
2004-04-06 |
Time |
11:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-02-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-02-25 |
Time |
15:27 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2004-02-25 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2004-02-25 00:00:00 | DENIED: | | | 1.PLEASE CLARIFY NOTE ON PLANS SHEET | | | M2.1, ALL OPEN DUCTS TO BE COVERED WITH | | | STAINLESS WIRE MESH.WILL THIS BE A | | | FINISHED PRODUCT OR FOR FUTURE?EXPLAIN | | | RATIONAL FOR NOT INSTALLING A GRILLE. | | | | | | 2.FAN SHUTDOWN BY DUCT SMOKE DETECTORS | | | SHALL HAVE NOTIFICATION TO ALARM/STROBE | | | IN NORMALLY OCCUPIED AREAS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-05-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-05-15 |
Time |
11:33 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2004-05-15 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-04-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-05 |
Time |
13:30 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2004-04-05 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2004-04-05 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | A) SOME COMMENTS FROM PREVIOUS REVIEW | | | HAVE NOT BEEN ADDRESS, OR OTHER COMMENTS | | | HAVE BEEN RAISED DUE TO COMMENT RESPONSE | | | THE NUMBERS FROM THE FIRST REVIEW WILL | | | BE USED TO AVOID CONFUSION. | | | 5) AN RPZ BACKFLOW IS REQUIRED ON WATER | | | SERVICE TO THE BLDG. SECTION 608.13.2. | | | NO RESPONSE OR BACKFLOW NOTED. | | | 7) SHT P0.1 WATER HEATER DETAIL, THERMAL | | | EXPANSION CONTROL IS REQUIRED. 607.3.2 - | | | DIELECTRIC UNIONS NOT APPROVED FOR WATER | | | USE, DELETE FROM DETAIL. (SEE PLUMBING | | | NOTE 14). - NO RESPONSE NOTED. | | | 8) SHT P0.1 WATER HEATER DETAIL, PROVIDE | | | INFORMATION FROM ENGINEER TO SHOW THAT | | | POINT LOADING OF WATER HEATER ON BOTTOM | | | CORD OF JOISTS HAS BEEN ADDRESSED. SEC | | | 1603.3. (APPROX. 300 LBS). | | | 11) SUBMIT A STORM RISER DIAGRAM. SHT | | | P4.1 STORM RISER DIAGRAM SHOWS 8" S.D. | | | (10,500 SQ FT) TO CATCH BASIN. MAXIMUM | | | 10,222 @ 1/8" PER FT SLOPE. EITHER 10" | | | PIPE IS REQUIRED OR SHOW SLOPE OF PIPE | | | GREATER THAN 1/8" PER FT. - THIS IS A | | | NEW COMMENT DUE TO RESPONSE TO ORIGINAL | | | COMMENT. | | | 12) SHT P-4.1 ROOF PIPING SUPPORT DETAIL | | | FOR CONDENSATE. IS THE CONCRETE STEPPING | | | STONES ON THE ROOF AN ENGINEERED SYSTEM | | | THAT WILL WITHSTAND 140 MPG WIND SPEED? | | | INDICATE HOW STONES WILL BE ATTACHED TO | | | THE ROOF. INDICATE HOW SLOPE WILL BE | | | MAINTAINED FROM ROOF UNITS TO ROOF DRAIN | | | RESPONSE NOTED WAS TO ELEMINATE THE DE- | | | TAIL. SUBMIT A NEW DETAIL AND ADDRESS | | | COMMENTS FROM PREVIOUS REVIEW. | | | 13) SHT P-4.1 ROOF PIPING SUPPORT DETAIL | | | FOR CONDENASATE. DETAIL INDICATES STONES | | | TO BE 6'0" ON CENTER. TABLE 308.5 STAES | | | 4'0" MAX FOR PVC PIPE HORZONTAL SPACING. | | | PLEASE CLAIRFY. - RESPONSE WAS TO DELETE | | | THE DETAIL. SUBMIT A DETAIL SHOWING HOW | | | THE CONDENSATE PIPING WILL BE INSTALLED. | | | *********WHEN RESUBMITTING PLANS******** | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | ******SEE ATTACHED SHEET CONCERNING***** | | | FS 533.80(2)(B) FOR ARCHITECTS & ENGIN- | | | EERS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-02-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-02-23 |
Time |
15:48 |
Rev Time |
2.50 |
| Received By |
kstevens |
Date |
2004-02-23 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2004-02-23 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 BUILDING | | | FBC-2001 CHAPTER 11 | | | | | | 1) ORIGINAL PERMIT APPLICATION REQUIRED. | | | COPIES OF SIGNATURES, NOTARY SEAL ECT | | | NOT ACCEPTABLE. | | | 2) SHOW CLEAR FLOOR SPACE FOR ALL | | | ACCESSIBLE FIXTURES PER 11-4.15.5, 11-4. | | | 16.2, 11-4.18.3, 11-4.19.3, 11-4.22.3, | | | AND 11-4.24.5. | | | 3) SHOW URINAL HEIGHT PER 11-4.18.2. | | | (SEE 11-4.22.5). | | | 4) SHOW LOUNGE, #107 DETAIL #7 SHT A-7.1 | | | KNEE CLEARANCE 11-4.24.3, DEPTH 11-4.24. | | | 4, & EXPOSED PIPES & SURFACES 11-4.24.6. | | | 5) AN RPZ BACKFLOW IS REQUIRED ON WATER | | | SERVICE TO BLDG. 608.13.2 | | | 6) INFORMATIONAL - SEPARATE IRRIGATION | | | PERMIT IS REQUIRED. | | | 7) SHT P0.1 WATER HEATER DETAIL, THERMAL | | | EXPANSION CONTROL IS REQUIRED 607.3.2. - | | | DIELECTRIC UNIONS NOT APPROVED FOR WATER | | | USE, DELETE FROM DETAIL. (SEE PLUMBING | | | NOTE #14). | | | 8) SHT P0.1 WATER HEATER DETAIL, PROVIDE | | | INFORMATION FROM ENGINEER TO SHOW THAT | | | POINT LOADING OF WATER HEATER ON BOTTOM | | | CORD OF JOISTS HAS BEEN ADDRESSED. SEC | | | 1603.3. (APPROX. 300 LBS.). | | | 9) SHT P2.1 STATES "CONNECT TO EXISTING | | | WATER & SEWER" PLEASE CLAIRFY. | | | 10) SHT P4.1 CENTER ROOF, - ROOF DRAIN | | | CALLS OUT 8,000 SF, BUT OVERFLOW DRAIN | | | ONLY INDICATES 2500 SF. PLEASE CLAIRFY. | | | SECTION 104.2.1 | | | 11) SUBMIT A STORM RISER DIAGRAM. SHOW | | | ALL PIPE SIZING AND INDICATE TERMINATION | | | OF PIPE. 104.3.1.1 | | | 12) SHT P4.1 ROOF PIPING SUPPORT DETAIL | | | FOR CONDENSATE, IS THE CONCRETE STEPPING | | | STONES ON THE ROOF AN ENGINEERED SYSTEM | | | THAT WILL WITHSTAND 140 MPH WIND SPEED? | | | INDICATE HOW STONES WILL BE ATTACHED TO | | | THE ROOF. INDICATE HOW SLOPE WILL BE | | | MAINTAINED FROM ROOF UNITS TO ROOF DRAIN | | | 13) SHT P4.1 ROOF PIPING SUPPORT DETAIL | | | FOR CONDENSATE, DETAIL INDICATES STONES | | | TO BE 6'0" ON CENTER, TABLE 308.5 STATES | | | 4'0" MAX FOR PVC PIPE HORIZONTAL SPACING | | | PLEASE CLAIRFY. | | | 14) PVC EXPOSED TO UV LIGHT RAYS FROM | | | THE SUN SHALL BE PAINTED WITH AN APPROV- | | | ED PAINT. (NON OIL BASE) | | | 15) SHT P5.1 DOMESTIC WATER ISOMETRIC, | | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURE IN AN "EFFECTIVE RANGE" | | | NOT IN THE CEILING AS SHOWN. PDI-WH 201 | | | AND MANUF. INSTALLATION INSTRUCTIONS. | | | (SEE PLUMBING NOTE #13 SHT P0.1) | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2004-11-30 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2004-11-30 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2004-11-30 00:00:00 | 11/30/2004 - REVISED LANDSCAPE PLAN | | | APPROVED.MINOR PD AMENDMENT APPROVED | | | ON 11/30/2004 (PB CASE NO. 791V). | | | JROACH, PLANNER 822-1435 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-02-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-11 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-02-11 |
Time |
11:29 |
Sent To |
I |
|
| Notes |
|
|