| Plan Review Stops For Permit 04020353 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-02 |
Time |
08:31 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-08-02 |
Time |
08:31 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-11-18 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-11-18 |
Time |
10:00 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2005-11-18 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2005-11-18 00:00:00 | PRODUCT APPROVAL REVISION OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-02 |
Time |
08:32 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-08-02 |
Time |
08:32 |
Sent To |
PC |
|
| Notes |
| 2005-08-02 00:00:00 | RESTAMP PLANS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2004-05-10 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2004-05-10 |
Time |
16:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2004-05-07 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2004-03-09 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2004-03-09 00:00:00 | BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, THE PERMIT PLANS STAMPED | | | BY THAT OFFICE AND A COPY OF THE PAID | | | RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION.CALL 561-233-5025 FOR | | | MORE INFORMATION. | | | | | | THE K.D. WINDOWS MULLION NOTICE OF | | | ACCEPTANCE IS NOT LISTED WITH THE STATE. | | | | | | PLEASE SELECT AND MARK THE COMPONENTS | | | THAT WILL USED IN THE NOTICE OF | | | ACCEPTANCE REPORTS. | | | | | | SHOW A BRIEF LOT DRAINAGE SCHEME SO THAT | | | COMPLIANCE WITH FBC 1804.1.7 AS AMENDED | | | BY THE CITY MAY BE DETERMINED. | | | | | | NOTE 5, WOOD TRUSS NOTES DOES SHOW THE | | | MINIMUM 10# LIVE LOAD FOR ATTICS | | | WITHOUT STORAGE AS REQUIRED BY FBC | | | TABLE 1604.1. | | | | | | THE COMPONENT AND CLADDING PRESSURES | | | SHOWN ARE NOT FOR A 5:12 PITCH ROOF. | | | PLEASE REVISE AS NECESSARY. | | | | | | SHOW OR NOTE THE SIZE OF THE ROOF AND | | | WALL ZONE AREAS TO COORDINATE WITH THE | | | C&C PRESSURES. | | | | | | PLEASE PROVIDE NOTICE OF ACCEPTANCE | | | REPORTS AND ANY OTHER PERTINENT DATA | | | FOR THE"FIBER CEMENT EXTERIOR LAP | | | SIDING" SHOWN IN SECTION ON SHEET A2. | | | | | | SHOW THE METHOD OF ATTIC VENTILATION AS | | | REQUIRED BY FBC 2309.7. | | | | | | PLEASE PROVIDE STRUCTURAL CALCULATIONS | | | DEMONSTRATING THAT THE EDGE DISTANCE OF | | | THE 5/8" X 7" EXPANSION BOLTS TO BE | | | USED IN THE SILL PLATE IS SUFFICIENT. | | | | | | WILL THE FIBER CEMENT SIDING PROVIDE A | | | MOISTURE BARRIER IN ACCORDANCE WITH FBC | | | 2303.3?INCLUDE DOCUMENTATION IF THAT | | | IS THE CASE. | | | | | | WILL THE R19 BATTS SPECIFIED IN SECTION | | | A FIT IN THE 2X4 STUD SPACE? | | | | | | CLEARLY NOTE THE WALL SHEATHING DISTANCE | | | TO GRADE AS SHOWN IN WALL SECTIONS A,B | | | AND C IN ACCORDANCE WITH FBC 2304.2.5. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-04-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-23 |
Time |
14:21 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-04-23 |
Time |
14:20 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-02-20 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-04-22 |
Time |
11:21 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-02-20 |
Time |
06:42 |
Sent To |
M |
|
| Notes |
| 2004-02-20 00:00:00 | ************* UNSAT *************** | | | | | | 1)NOTE: PLEASE INCLUDE ALL LICENSE #'S | | | IN TITLE BLOCK. THIS INCLUDES FIRMS #/ | | | CERTIFICATE OF AUTHORIZATION # AS REQ'D | | | UNDER FS 481.219 | | | THIS IS FOR ALL SHEETS/TRADES, WEATHER | | | OR NOT COMMENT IS MADE BY OTHER REVIEWER | | | -S. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-01 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-01 |
Time |
10:43 |
Sent To |
B |
|
| Notes |
| 2005-08-01 00:00:00 | TO "JWITMER" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-04-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-04-22 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-04-22 |
Time |
11:19 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-13 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-11 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2004-02-13 00:00:00 | TO SFD RACK/E | | 2004-02-11 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2004-03-09 |
Time |
08:41 |
Rev Time |
0.25 |
| Received By |
hmoser |
Date |
2004-03-09 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2004-03-09 00:00:00 | REFER TO SECTION 307.2.3 AUXILIARY DRAIN | | | PANS 2001 F.B.C (M) | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-02-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-02-20 |
Time |
06:42 |
Rev Time |
0.25 |
| Received By |
hmoser |
Date |
2004-02-26 |
Time |
16:31 |
Sent To |
P |
|
| Notes |
| 2004-02-26 00:00:00 | PLAN DENIED | | | NO MANUAL (J) | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-05-07 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2004-05-07 |
Time |
15:09 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
| 2004-05-07 00:00:00 | RE-SUB WITH PLUMBING ISOMETRIC,OK. PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-05-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-23 |
Time |
14:21 |
Rev Time |
0.25 |
| Received By |
pschmitz |
Date |
2004-02-28 |
Time |
10:48 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-02-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-13 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-02-13 |
Time |
14:31 |
Sent To |
I |
|
| Notes |
|
|