Plan Review Details - Permit 04020353
Plan Review Stops For Permit 04020353
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2005-08-02 Cont ID  
Sent By jwitmer Date 2005-08-02 Time 08:31 Rev Time 0.55
Received By jwitmer Date 2005-08-02 Time 08:31 Sent To P
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-11-18 Cont ID  
Sent By alange Date 2005-11-18 Time 10:00 Rev Time 0.50
Received By alange Date 2005-11-18 Time 10:00 Sent To  
Notes
2005-11-18 00:00:00PRODUCT APPROVAL REVISION OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-08-02 Cont ID  
Sent By jwitmer Date 2005-08-02 Time 08:32 Rev Time 0.55
Received By jwitmer Date 2005-08-02 Time 08:32 Sent To PC
Notes
2005-08-02 00:00:00RESTAMP PLANS

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-05-10 Cont ID  
Sent By hpiskura Date 2004-05-10 Time 17:11 Rev Time 0.00
Received By hpiskura Date 2004-05-10 Time 16:38 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-03-09 Cont ID  
Sent By pschmitz Date 2004-05-07 Time 15:12 Rev Time 0.00
Received By hpiskura Date 2004-03-09 Time 07:16 Sent To  
Notes
2004-03-09 00:00:00BEFORE A PERMIT TO CONSTRUCT MAY BE
 ISSUED IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, THE PERMIT PLANS STAMPED
 BY THAT OFFICE AND A COPY OF THE PAID
 RECEIPT ATTACHED TO THE PERMIT
 APPLICATION.CALL 561-233-5025 FOR
 MORE INFORMATION.
  
 THE K.D. WINDOWS MULLION NOTICE OF
 ACCEPTANCE IS NOT LISTED WITH THE STATE.
  
 PLEASE SELECT AND MARK THE COMPONENTS
 THAT WILL USED IN THE NOTICE OF
 ACCEPTANCE REPORTS.
  
 SHOW A BRIEF LOT DRAINAGE SCHEME SO THAT
 COMPLIANCE WITH FBC 1804.1.7 AS AMENDED
 BY THE CITY MAY BE DETERMINED.
  
 NOTE 5, WOOD TRUSS NOTES DOES SHOW THE
 MINIMUM 10# LIVE LOAD FOR ATTICS
 WITHOUT STORAGE AS REQUIRED BY FBC
 TABLE 1604.1.
  
 THE COMPONENT AND CLADDING PRESSURES
 SHOWN ARE NOT FOR A 5:12 PITCH ROOF.
 PLEASE REVISE AS NECESSARY.
  
 SHOW OR NOTE THE SIZE OF THE ROOF AND
 WALL ZONE AREAS TO COORDINATE WITH THE
 C&C PRESSURES.
  
 PLEASE PROVIDE NOTICE OF ACCEPTANCE
 REPORTS AND ANY OTHER PERTINENT DATA
 FOR THE"FIBER CEMENT EXTERIOR LAP
 SIDING" SHOWN IN SECTION ON SHEET A2.
  
 SHOW THE METHOD OF ATTIC VENTILATION AS
 REQUIRED BY FBC 2309.7.
  
 PLEASE PROVIDE STRUCTURAL CALCULATIONS
 DEMONSTRATING THAT THE EDGE DISTANCE OF
 THE 5/8" X 7" EXPANSION BOLTS TO BE
 USED IN THE SILL PLATE IS SUFFICIENT.
  
 WILL THE FIBER CEMENT SIDING PROVIDE A
 MOISTURE BARRIER IN ACCORDANCE WITH FBC
 2303.3?INCLUDE DOCUMENTATION IF THAT
 IS THE CASE.
  
 WILL THE R19 BATTS SPECIFIED IN SECTION
 A FIT IN THE 2X4 STUD SPACE?
  
 CLEARLY NOTE THE WALL SHEATHING DISTANCE
 TO GRADE AS SHOWN IN WALL SECTIONS A,B
 AND C IN ACCORDANCE WITH FBC 2304.2.5.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-04-23 Cont ID  
Sent By dpalmer Date 2004-04-23 Time 14:21 Rev Time 0.33
Received By dpalmer Date 2004-04-23 Time 14:20 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-02-20 Cont ID  
Sent By alange Date 2004-04-22 Time 11:21 Rev Time 0.33
Received By dpalmer Date 2004-02-20 Time 06:42 Sent To M
Notes
2004-02-20 00:00:00************* UNSAT ***************
  
 1)NOTE: PLEASE INCLUDE ALL LICENSE #'S
 IN TITLE BLOCK. THIS INCLUDES FIRMS #/
 CERTIFICATE OF AUTHORIZATION # AS REQ'D
 UNDER FS 481.219
 THIS IS FOR ALL SHEETS/TRADES, WEATHER
 OR NOT COMMENT IS MADE BY OTHER REVIEWER
 -S.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-08-01 Cont ID  
Sent By adarroug Date 2005-08-01 Time 10:43 Rev Time 0.00
Received By adarroug Date 2005-08-01 Time 10:43 Sent To B
Notes
2005-08-01 00:00:00TO "JWITMER" DESK/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-04-22 Cont ID  
Sent By alange Date 2004-04-22 Time 11:19 Rev Time 0.00
Received By alange Date 2004-04-22 Time 11:19 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-03-09 Cont ID  
Sent By mmclean Date 2004-02-13 Time 14:31 Rev Time 0.00
Received By csiegber Date 2004-02-11 Time 14:50 Sent To  
Notes
2004-02-13 00:00:00TO SFD RACK/E
2004-02-11 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-03-09 Cont ID  
Sent By hmoser Date 2004-03-09 Time 08:41 Rev Time 0.25
Received By hmoser Date 2004-03-09 Time 08:41 Sent To  
Notes
2004-03-09 00:00:00REFER TO SECTION 307.2.3 AUXILIARY DRAIN
 PANS 2001 F.B.C (M)
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-02-26 Cont ID  
Sent By dpalmer Date 2004-02-20 Time 06:42 Rev Time 0.25
Received By hmoser Date 2004-02-26 Time 16:31 Sent To P
Notes
2004-02-26 00:00:00PLAN DENIED
 NO MANUAL (J)
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-05-07 Cont ID  
Sent By pschmitz Date 2004-05-07 Time 15:09 Rev Time 1.00
Received By pschmitz Date   Time   Sent To B
Notes
2004-05-07 00:00:00RE-SUB WITH PLUMBING ISOMETRIC,OK. PES

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-05-07 Cont ID  
Sent By dpalmer Date 2004-04-23 Time 14:21 Rev Time 0.25
Received By pschmitz Date 2004-02-28 Time 10:48 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-02-13 Cont ID  
Sent By mmclean Date 2004-02-13 Time 14:31 Rev Time 0.00
Received By mmclean Date 2004-02-13 Time 14:31 Sent To I
Notes
***NONE***