Plan Review Details - Permit 04020208
Plan Review Stops For Permit 04020208
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-04-07 Cont ID  
Sent By rbrown Date 2004-04-07 Time 17:24 Rev Time 0.00
Received By rbrown Date 2004-04-07 Time 17:24 Sent To  
Notes
2004-04-07 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 --PROVISO--
 FBC 1606.1.4HURRICANE MISSILE IMPACT
 PROTECTION SHALL BE PROVIDED UNDER A
 SEPARATE PERMIT APPLICATION.
  
 --PROVISO--
 BREAKFAST AREA HORIZONTAL SLIDING WINDOW
 PRODUCT APPROVALS.THESE TWO WINDOWS
 ARE 6060 HR AND THEREFOR EXCEED THE
 MAXIMUM HEIGHT STATED ON DRAWING
 SHEET 3 OF THE SUBMITTED PRODUCT
 APPROVAL (NOA# 01-0724.05).AMEND THE
 SIZE/TYPE OF THE WINDOWS, OR SUBMIT A
 PRODUCT APPROVAL WHICH IS APPLICABLE,
 BEFORE BUCK INSPECTION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-03-15 Cont ID  
Sent By alange Date 2004-03-30 Time 09:52 Rev Time 0.00
Received By rbrown Date 2004-03-12 Time 16:07 Sent To  
Notes
2004-03-15 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) 61G1-16.004FL. ADMIN. CODE.PLANS
 PREPARED BY A REGISTERED ARCHITECT SHALL
 INCLUDE THE PRINTED NAME AND LICENSE
 NUMBER OF THE ARCHITECT SEALING THE
 PLANS.ALSO, THE RAISED SEAL DOES NOT
 SHOW THE LICENSE NUMBER OF STUART
 BRENNER (AR0014503).PROVIDE THE
 REQUIRED INFORMATION ON EACH
 ARCHITECTURAL SHEET.
  
 2) BREAKFAST AREA HORIZONTAL SLIDING
 WINDOW PRODUCT APPROVALS.THESE TWO
 WINDOWS ARE 6060 HR AND THEREFOR EXCEED
 THE MAXIMUM HEIGHT STATED ON DRAWING
 SHEET 3 OF THE SUBMITTED PRODUCT
 APPROVAL NOA# 01-0724.05.AMEND THE
 SIZE/TYPE OF THE WINDOWS OR SUBMIT A
 PRODUCT APPROVAL WHICH IS APPLICABLE.
  
 3) FBC 1015.3SHEET A-8, DETAIL 13,
 STAIR GUARDRAIL.THE INTERMEDIATE RAILS
 SHALL BE SPACED SO AS TO RESIST THE
 PASSAGE OF A 4" SPHERE.AMEND/ANNOTATE
 THE PLANS.
  
 --PROVISO--
 FBC 1606.1.4HURRICANE MISSILE IMPACT
 PROTECTION SHALL BE PROVIDED UNDER A
 SEPARATE PERMIT APPLICATION.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-09-21 Cont ID  
Sent By btrobaug Date 2004-09-21 Time 13:18 Rev Time 0.50
Received By btrobaug Date 2004-09-21 Time 13:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-02-17 Cont ID  
Sent By csiegber Date 2004-09-14 Time 16:37 Rev Time 0.50
Received By btrobaug Date 2004-02-17 Time 06:18 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-09-14 Cont ID  
Sent By csiegber Date 2004-09-14 Time 16:37 Rev Time 0.00
Received By csiegber Date 2004-09-14 Time 16:37 Sent To E
Notes
2004-09-14 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-30 Cont ID  
Sent By alange Date 2004-03-30 Time 09:52 Rev Time 0.00
Received By alange Date 2004-03-30 Time 09:52 Sent To B
Notes
2004-03-30 00:00:00TO RB DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-03-15 Cont ID  
Sent By mmclean Date 2004-02-09 Time 16:26 Rev Time 0.50
Received By btrobaug Date 2004-02-06 Time 16:45 Sent To  
Notes
2004-02-11 00:00:00TO SFD RACK/E
2004-02-06 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-02-21 Cont ID  
Sent By btrobaug Date 2004-03-16 Time 06:20 Rev Time 0.50
Received By rregueir Date 2004-02-21 Time 13:48 Sent To B
Notes
2004-02-21 00:00:00PROVISO
 ----------------------------------------
 REFER TO FBC(M)601.4 REVISED JULY 1,2003
 FOR PROPER SIZING OF R/A TRANSFER DUCTS.
 NOTE THAT BALANCED R/A IS REQUIRED FROM
 ALL HABITABLE ROOMS. THIS PLAN DOES NOT
 SHOW ANY R/A IN THE DEN. ALSO NOTE THAT
 ALL DROPS IN THE MASTER SUITE SHALL BE
 INCLUDED WHEN CALCULATING SIZE OF TRANS-
 FER DUCTS.
  
 PLEASE CALL WITH ANY QUESTIONS
 RONALD J REGUEIRO 561-805-6734

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-02-12 Cont ID  
Sent By jleech Date 2004-02-12 Time 10:22 Rev Time 0.33
Received By jleech Date 2004-02-12 Time 10:22 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-02-09 Cont ID  
Sent By mmclean Date 2004-02-09 Time 16:26 Rev Time 0.00
Received By mmclean Date 2004-02-09 Time 16:26 Sent To I
Notes
***NONE***