Plan Review Details - Permit 04020173
Plan Review Stops For Permit 04020173
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-07-08 Cont ID  
Sent By alange Date 2004-07-08 Time 14:06 Rev Time 0.00
Received By mjacobs Date 2004-07-08 Time 09:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-03-09 Cont ID  
Sent By btrobaug Date 2004-07-07 Time 13:37 Rev Time 1.75
Received By alange Date 2004-03-09 Time 10:14 Sent To  
Notes
2004-03-09 00:00:00DENIED
 1. THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSEAND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
 2.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 3.PERMIT VALUE TOO LOW.PROJECT
 VALUE IS AT LEAST $14,000.ADJUST
 VALUEAND PAY ADDITION PERMIT FEES.
 4.SHOW METHOD OF SHEATHING FASTENING.
 TYPE SIZE AND SPACING.
 5. WPB AMMENDMENT TO THE FBC 1804.1.7
 THE LOWEST FINISH FLOOR ELEVATION FOR
 HABITABLE AREAS SHALL BE A MIN. OF 4"
 ABOVE GRADE AT THE BUILDING PERIMETER.
 6.SUBMIT FRAMING DETAIL OF GUEST
 COTTAGE.SHOW HEADERS, SIZE AND TYPE OF
 FRAMING AND STRAPING USED.
 7. WINDOW AND DOOR BUCK SHALL COMPLY
 WITH FBC 1707.4.4.2 SHOW DETAILS.
 8.SPECIFY INSULATION TYPE AND R VALUE
 AND INTERIOR AND EXTERIOR WALL VENEERS.
 9. SHOW ON A SITE PLAN THE AREAS AROUND
 GUEST COTTAGE SO WE CAN ADDRESS
 POSSIBLETABLE 600 ISSUES.
 10.SHOW METHOD OF IMPACT PROTECTION
 USED AND SUBMIT PRODUCT APPROVALS FOR
 THE IMPACT PROTECTION.
 11.PRODUCT APPROVAL FOR ALMAR ROOFING
 NOT LISTED ON THE FBC PRODUCT APPROVAL
 SITE.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 ANY QUESTIONS CALL ME.
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-07-07 Cont ID  
Sent By btrobaug Date 2004-07-07 Time 13:37 Rev Time 0.50
Received By btrobaug Date 2004-07-07 Time 13:37 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-02-11 Cont ID  
Sent By csiegber Date 2004-07-06 Time 08:54 Rev Time 0.75
Received By btrobaug Date 2004-02-11 Time 17:24 Sent To P
Notes
2004-02-11 00:00:00 
 UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE PROVIDE A CALCULATION INCLUDI
 NG ALL ADDED LOADS IMPOSED,ALL EXISTING
 LOADS AND THE EXISTING OR PROPOSED
 SERVICE SPECIFICATIONS PER 215.15.
  
 2} PLEASE INCLUDE A RISER DIAGRAM
 SHOWING COMPLIANCE WITH 225.31 & 250.32.
  
 3} PLEASE SHOW COMPLIANCE WITH
 210.8(A)(1) & 210.8(A)(7), GFI'S.
  
 4} PLEASE LIST ALL THE REQ'D
 DEDICATED BATH(S) CIRCUIT(S) ON PANEL
 SCHEDULE. PER 210.52D, 210.11C3
  
 5} PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CURCUIT(S) ON PANEL
 SCHEDULE. PLEASE SEE THAT ALL "OUTLETS"
 IN BEDROOMS ARE TO BE PROTECTED ,
 INCLUDING, LTS, RECEPTS, SD'S ETC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-03-03 Cont ID  
Sent By mjacobs Date 2005-03-03 Time 09:32 Rev Time 0.00
Received By mjacobs Date 2005-03-03 Time 09:32 Sent To P
Notes
2005-03-03 00:00:00TO "P" BOX.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-07-06 Cont ID  
Sent By csiegber Date 2004-07-06 Time 08:54 Rev Time 0.00
Received By csiegber Date 2004-07-06 Time 08:54 Sent To E
Notes
2004-07-06 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-07-01 Cont ID  
Sent By mmclean Date 2004-07-02 Time 16:22 Rev Time 0.00
Received By csiegber Date 2004-07-01 Time 14:56 Sent To Z
Notes
2004-07-01 00:00:00RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-02-11 Cont ID  
Sent By csiegber Date 2004-02-11 Time 09:54 Rev Time 0.00
Received By csiegber Date 2004-02-11 Time 09:54 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-05 Cont ID  
Sent By mmclean Date 2004-02-09 Time 16:48 Rev Time 0.00
Received By csiegber Date 2004-02-05 Time 12:31 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2004-02-23 Cont ID  
Sent By kstevens Date 2004-02-12 Time 12:32 Rev Time 0.20
Received By pkrauss Date 2004-02-23 Time 07:17 Sent To B
Notes
2004-02-23 00:00:00PLAN OF THE POOL CABANA INDICATES A WALL
 A/C UNIT.WALL UNIT WILL NOT REQUIRE A
 MECHANICAL PERMIT.A MINI-SPLIT OR ANY
 OTHER TYPE OF A/C UNIT WILL REQUIRE A
 MECHANICAL PERMIT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-03-15 Cont ID  
Sent By gsalfeld Date 2005-03-15 Time 10:12 Rev Time 0.50
Received By gsalfeld Date 2005-03-15 Time 10:11 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-02-12 Cont ID  
Sent By btrobaug Date 2004-02-11 Time 17:45 Rev Time 0.50
Received By kstevens Date 2004-02-12 Time 12:32 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2004-07-02 Cont ID  
Sent By mmclean Date 2004-07-02 Time 16:22 Rev Time 0.00
Received By mmclean Date 2004-07-02 Time 16:22 Sent To I
Notes
2004-07-02 00:00:00MUST HAVE A MIN OF 6FT SEPARATION FROM
 CABANA TO MAIN STRUCTURE WITH ROOF MM

Review Stop Z ZONING
Rev No 1 Status F Date 2004-02-09 Cont ID  
Sent By csiegber Date 2004-07-01 Time 14:56 Rev Time 0.00
Received By mmclean Date 2004-02-09 Time 16:48 Sent To I
Notes
2004-02-09 00:00:00DENIED, NEED TO SHOW WORK ON SURVEY
 CALLED OWNER MM


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved