| Plan Review Stops For Permit 04020100 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-04-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-04-07 |
Time |
15:48 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2004-04-07 |
Time |
15:48 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-03-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-02 |
Time |
15:27 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2004-03-03 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2004-03-03 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04020100 | | | ADD: 401 N DIXIE HWY | | | CONT: M. A. C. CONSTRUCTION | | | TEL: (786)357-0214 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) TABLE 803.3 MINIMUM INTERIOR FINISH | | | CLASSIFICATION; PROVIDE INFORMATION | | | BASED ON INTERIOR FINISH REQUIREMENTS | | | BASED ON OCCUPANCY: BUSINESS. | | | | | | 2)11-4.13.6 MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARENCES SHALL BE | | | CLEAR & LEVEL. | | | THE 2 END OFFICES ON THE RIGHT SIDE OF | | | THE SHEET DO NOT HAVE 12" CLEAR ON THE | | | LATCH SIDE OF THE DOOR. | | | | | | 3) PLANS INDICATE THE LOCKS OR LATCHSETS | | | ARE TO MATCH EXISTING. PLANS DO NOT | | | INDICATE COMPLIANCE WITH 11-4.13.9 | | | ACCESSIBLE DOORS: LEVER-OPERATED MECHAN- | | | ISMS, PUSH-TYPE MECHANISMS, AND U SHAPED | | | HANDLES ARE ACCESSIBLE DESIGNS. | | | | | | 4) PLANS INDICATE WORK ON THE 5TH FLOOR | | | THE PERMIT APP DOES NOT INDICATE THIS | | | SO SAID WORK HAS BEEN STRUCK FROM PERMIT | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-03-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-03-02 |
Time |
16:50 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-03-02 |
Time |
16:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-02-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-02-09 |
Time |
15:51 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-02-09 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2004-02-09 00:00:00 | ELECTRICAL PLANS OK. | | | BLDG PLANS, ARCH IS REQ'D TO HAVE THE | | | CERTIFICATE OF AUTHORIZATION # CON TITLE | | | BLOCK PER FS 481.219 AND FAC 61G1-16.004 | | | ABOVE COMMENT IS REQ'D. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2004-02-03 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-02-03 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-02-03 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2004-02-03 00:00:00 | *************PROVISO******************** | | | SEPARATE PLANS AND PERMIT APPLICATIONS | | | ARE REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM SYSTEMS REMODEL. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-07-23 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-07-23 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-07-23 |
Time |
12:14 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-04-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-02 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-02 |
Time |
15:26 |
Sent To |
B |
|
| Notes |
| 2004-04-02 00:00:00 | TO JW DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-03-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-03 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2004-02-03 |
Time |
13:58 |
Sent To |
PC |
|
| Notes |
| 2004-02-03 00:00:00 | TO COMM BD#41 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-03 |
Time |
15:25 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-08-03 |
Time |
14:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-02-20 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-07-23 |
Time |
12:14 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-02-20 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2004-02-20 00:00:00 | PROVISO: | | | PLEASE VERIFY EXISTING FIRE DAMPER ON | | | THE EXISTING 34" X 18" HIGH PRESSURE | | | DUCT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2004-02-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-02-06 |
Time |
17:20 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-02-06 |
Time |
17:20 |
Sent To |
|
|
| Notes |
| 2004-02-06 00:00:00 | NO PLUMBING OR PLUMBING PLANS SUBMITTED |
|
|