Plan Review Details - Permit 04011419
| Plan Review Stops For Permit 04011419 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-03-15 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-03-15 |
Time |
07:54 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
2004-03-15 |
Time |
07:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-02-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-11 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-03-15 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2004-02-27 00:00:00 | | | | EASEMENT CONSENT FORM NOT APPROVED BY | | | UTILITIES DEPT. CALLED CONTRACTOR TO | | | PICK UP PLANS. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-02-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-26 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-02-03 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2004-02-03 00:00:00 | BUILDING PLAN REVIEW; FAILED!! | | | | | | 1. PVC FENCE NOT SHOWN ON PERMIT | | | APPLICATION. NO UTILITY EASEMENT FORM | | | INCLUDED FOR FENCE. | | | 2. DESIGN WIND SPEED IS 140 MPH FOR PALM | | | BEACH COUNTY. DRAWINGS ARE NOT CLEAR, | | | ENGINEER SIGNATURE IS NOT ORIGINAL WITH | | | RAISED SEAL ON PVC DRAWING. | | | 3. PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE | | | AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | THESESTATE PRODUCT APPROVALS ARE | | | REQUIRED FOT THE ALUMINUM ROOF. | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-03-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-11 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-11 |
Time |
14:54 |
Sent To |
B |
|
| Notes |
| 2004-03-11 00:00:00 | TO LS DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-02-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-26 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-26 |
Time |
16:57 |
Sent To |
B |
|
| Notes |
| 2004-02-26 00:00:00 | TO LS DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-02-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-02 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-29 |
Time |
14:39 |
Sent To |
B |
|
| Notes |
| 2004-02-02 00:00:00 | TO MISC BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-02 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-29 |
Time |
14:55 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-02-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-29 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-02-02 |
Time |
13:00 |
Sent To |
I |
|
| Notes |
| 2004-02-02 00:00:00 | SCREEN ENCLOSURE ONLY |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |