| Plan Review Stops For Permit 04011273 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
P |
Date |
2007-01-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-01-23 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-01-23 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2007-01-23 15:48:20 | REVISION; BEAM DETAIL AND LETTER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
P |
Date |
2006-11-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-11-07 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-11-07 |
Time |
12:12 |
Sent To |
M |
|
| Notes |
| 2006-11-07 12:13:04 | FIREPLACE DETAIL DATED 10/26/06 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2006-10-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-10-12 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-10-12 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2006-10-12 16:03:40 | REVISE A5 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
F |
Date |
2006-10-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-10-12 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-10-12 |
Time |
08:21 |
Sent To |
PC |
|
| Notes |
| 2006-10-12 09:00:49 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2001 | | | | | | 1.)ONLY ONE SET WAS SIGNED AND SEALED.TWO ORIGINAL | | | SIGNED, SEALED, DATED SETS REQUIRED. | | | | | | 2.)SEE PREVIOUS LIST.SHEET 05, DESIGN CRITERIA FOR | | | THE GUARDRAIL IS TO COMPLY WITH FBC1608.2.NOTE THAT | | | THE STARRAIL ALSO SERVES AS A GUARDRAIL, 25#/LF IS | | | SPECIFIED FOR PICKETS.SEE 1608.2.2.3, 200#/SF IS | | | REQUIRED.THE 25#/LF NOTE WAS NOT REMOVED FROM THE | | | PLAN SO YOU NOW HAVE CONFLICTING DESIGN CRITERIA. | | | | | | 3.)THE CHANGES TO THE PLAN WERE APPARENTLY MADE BY | | | SOMEONE OTHER THAN THE ARCHITECT.HAVE THE CHANGES | | | INCORPORATED INTO THE PLAN AND HAVE THE PLANS SIGNED, | | | SEALED, AND DATED BY SHANE AMES AS REQUIRED BY | | | FAC61G1-16.003, 004. | | | | | | SOMEONE NAMED HASAN HAD REPRESENTED HIMSELF AS THE | | | ARCHITECT ON THE PROJECT.HIS RELATIONSHIP WITH AMES | | | DESIGN INTERNATIONAL IS UNCLEAR.IF HE AN ARCHITECT | | | WORKING THROUGH AMES DESIGN INTERNATIONAL, PLEASE | | | CONTACT ME IN REGARDS TO THE CORRECT PROCEDURE FOR HIM | | | TO MODIFY PLANS ALREADY SEALED BY ANOTHER ARCHITECT IN | | | THE FIRM.HE CANNOT MAKE THE CHANGES ON THE PLAN AND | | | SIGN ANOTHER ARCHITECT?S NAME ON BEHALF OF THE | | | ARCHITECT.IF THE ARCHITECT ON THIS PROJECT HAS | | | CHANGED, SEE FAC61G1-18.002 FOR PROCEDURES FOR A | | | SUCCESSOR ARCHITECT ADOPTING ANOTHER ARCHITECT?S WORK. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
F |
Date |
2006-09-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-10-12 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-09-13 |
Time |
13:30 |
Sent To |
P |
|
| Notes |
| 2006-09-13 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)SHEET 05, DESIGN CRITERIA FOR THE | | | GUARDRAIL AND STAIRRAIL IS TO COMPLY | | | WITH FBC1608.2.NOTE THAT THE STAIRRAIL | | | ALSO SERVES AS A GUARDRAIL, 25#/LF IS | | | SPECIFIED FOR PICKETS.SEE | | | FBC1608.2.2.3, 200#/SF REQUIRED. | | | | | | INCLUDE ALL DESIGN CRITERIA FOR | | | STAIRRAILS AND GUARDRAILS, FBC1608.2. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-01-24 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-01-24 |
Time |
14:06 |
Sent To |
PC |
|
| Notes |
| 2005-01-24 00:00:00 | TRUSS DRAWINGS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-01-10 |
Time |
14:04 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2005-01-10 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2005-01-10 00:00:00 | ****CORRECTIONS**** | | | TRUSS DRAWING FAX | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)10# BCLL TO BE A CONCURRENT LOAD. | | | | | | 2.)1.33 DURATION INCREASE FOR PLATES | | | ACCEPTABLE. | | | | | | 3.)PLEASE HAVE DOR CONFIRM TCDL. | | | | | | | | | VIA TELEPHONE CONVERSATION W/TRUSS | | | MANUFACTURER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-01-06 |
Time |
09:52 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2005-01-06 |
Time |
09:52 |
Sent To |
PC |
|
| Notes |
| 2005-01-06 00:00:00 | ****CORRECTIONS**** | | | TRUSS ENGINEERING | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THERE IS A NOTE FROM YOU DOR ON | | | YOUR PLAN THAT EOR IS TO REVIEW | | | STRAPPING (SHEET 10).PLEASE HAVE | | | REVIEWED BEFORE RESUBMITTAL. | | | | | | 2.)THE NEW TRUSS CALCS, ROOF, SHOW A | | | STRESS INCREASE OF 1.25 FOR THE TRUSSES | | | AND FOR THE PLATES.STRESS INCREASE FOR | | | STEEL IS NOT PERMITTED FBC1609.4.3(2). | | | | | | 3.)DOR HAS SPECIFIED A ROOF LIVE LOAD | | | OF 30; TRUSS DRAWINGS SHOW 20. | | | | | | 4.)INDEX SHEET SHOWS THE WRONG | | | ADDRESS.THIS JOB IS NOT IN BOCA RATON. | | | SECOND TIME THIS CORRECTION HAS BEEN | | | MADE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-29 |
Time |
16:50 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-12-29 |
Time |
16:50 |
Sent To |
PC |
|
| Notes |
| 2004-12-29 00:00:00 | ****CORRECTIONS**** | | | TRUSS SUBMITTAL | | | 2ND REVIEW | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SEE PREVIOUS LIST.ATTICS ARE IN | | | THE ROOF, NOT THE FLOOR.BOTTOM CHORD | | | LIVE LOAD IS TO BE 10 FOR ATTICS WITH NO | | | STORAGE, 30 FOR ATTICS WITH STORAGE FBC | | | TABLE 1604.1. | | | | | | 2.)FLOOR TRUSS TOTAL LOAD SHOWN ON THE | | | INDEX PAGE IS NOT CORRECT.40+10+10+10 | | | EQUALS 70, NOT 65. | | | | | | 3.)PROJECT NAME AND ADDRESS ON THE | | | INDEX SHEET IS INCORRECT.I ASSUME THAT | | | THIS IS THE SUBCONTRACTOR; SHOULD BE THE | | | PROJECT NAME AND ADDRESS.IF THIS IS | | | THE PROJECT, WRONG JOB - STATES 105 | | | BEVERLY ROAD, BOCA RATON. | | | | | | 4.)SOME OF THE DETAILS PROVIDED SHOULD | | | EITHER BE SEALED OR REFERENCED ON THE | | | INDEX SHEET.NOTE THAT THE INDEX SHEET | | | DOES NOT REFER TO ALL SHEETS IN THE | | | PACKAGE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-23 |
Time |
08:30 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-12-23 |
Time |
08:30 |
Sent To |
PC |
|
| Notes |
| 2004-12-23 00:00:00 | ****CORRECTIONS***** | | | TRUSS SUBMITTAL | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)BCLL OF 10PSF REQUIRED FOR ATTICS | | | WITHOUT STORAGE, 30PSF FOR ATTICS WITH | | | STORAGE, FBC TABLE 1604.1. | | | | | | 2.)ORIGINAL SIGNATURE REQUIRED, NOT A | | | STAMP, FAC61G15-23.002. | | | | | | 3.)TITLE BLOCK REQUIRED WITH ALL | | | INFORMATION REQUIRED BY | | | FAC61G15-23.002. | | | | | | 4.)SOME SHEETS ARE NOT SIGNED AND | | | SEALED.ALL DOCUMENTS SUBMITTED FOR | | | PUBLIC RECORD PREPARED BY AND ENGINEER | | | ARE TO BE SIGNED AND SEALED, | | | FAC61G15-23.002. | | | | | | 5.)PLEASE ADVISE AS TO THE STATUS FOR | | | THE ENGINEERING FOR THE METAL ROOF | | | (PROVISO WHEN THE PERMIT WAS ISSUED). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-07-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-07-14 |
Time |
10:55 |
Rev Time |
3.00 |
| Received By |
shill |
Date |
2004-07-14 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2004-07-14 00:00:00 | PROVISO - | | | 1. ENGINEERING FOR METAL ROOF TO | | | BE SUBMITTED AS A REVISION.SEE ROOF | | | PA.SUBMIT SKYLIGHT PRODUCT APPROVAL | | | WITH ROOF. | | | | | | 2.PROVIDE A STRUCTURAL DETAIL FOR THE | | | STAIRS, INCLUDING FIREBLOCKING. | | | | | | 3.SEPARATE PERMIT FOR ELEVATOR |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-07-13 |
Time |
16:40 |
Rev Time |
3.00 |
| Received By |
shill |
Date |
2004-06-15 |
Time |
12:22 |
Sent To |
|
|
| Notes |
| 2004-06-15 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE NOTICE OF COMMENCEMENT IS | | | EXPIRED (MORE THAN 90 DAYS WITHOUT | | | COMMENCING WORK), FS713.13. | | | | | | 2.)THE SURVEY SHOWS THE PROPOSED | | | FINISHED FLOOR ELEVATION AS 7.1; IT | | | IS REQUIRED TO BE 7.5 MIN CITY OF WEST | | | PALM BEACH MUNICIPAL CODE 94-546(B)(1). | | | | | | 3.)PROVIDE TWO ORIGINAL SEALED SOILS | | | REPORTS. | | | | | | 4.)SEE PREVIOUS LIST, PROVIDE | | | INFORMATION FOR THE FIREPLACE AND | | | CHIMNEY.FACTORY BUILT CHIMNEYS AND | | | FIREPLACES SHALL BE TESTED IN | | | ACCORDANCE WITH AND MEET THE REQUIREMENT | | | OF UL127 (OR MAY BE ON SEPARATE PERMIT). | | | | | | 5.)ADDITIONAL FEES DUE. | | | | | | 6.)THE SEAL IS TO BE DATED AS WELL | | | AS SIGNED, FAC61G1-16.003, 004. | | | | | | 7.)SEPARATE PERMIT FOR ELEVATOR, GAS. | | | | | | 8.)SEE PREVIOUS LIST IN REGARDS TO THE | | | ENERGY CALCS.THEY SHOULD REFLECT THE | | | SQUARE FOOTAGE UNDER AIR OF 3631.OR, | | | IF THE PLAN UNDER AIR IS INCORRECT, | | | REVISE THE PLAN TO MATCH THE ENERGY | | | CALC (3844 SF) AND HAVE THE IMPACT FEE | | | STAMP CHANGED TO ALSO REFLECT THE 3844 | | | SF. | | | | | | 9.)SEE PREVIOUS LIST, ITEM #25.TWO | | | COPIES OF ALL DOCUMENTATION (INCLUDING | | | EN CALCS AND ALL PRODUCT APPROVALS) ARE | | | TO BE SUBMITTED.EACH TEST REPORT IS | | | TO HAVE A FLORIDA STATE, LOCAL OR SITE | | | SPECIFIC PRODUCT APPROVAL. | | | WWW.FLORIDABUILDING.ORG | | | | | | 10.) ITEM #26 WAS NOT ADDRESSED (A | | | STRUCTURAL DETAIL FOR THE STAIRS, | | | INCLUDING FIREBLOCKING).THIS MAY BE | | | ISSUED WITH A PROVISO TO PROVIDE THIS | | | DETAIL BEFORE INSTALLATION. | | | | | | 11.)SEE THE PREVIOUS LIST IN REGARDS | | | TO THE ROOF PRODUCT APPROVAL (COPPER | | | SALES UC3-12).I HAVE HIGHLIGHTED THE | | | PERTINENT INFORMATION.THE DESIGN | | | PRESSURES CAN BE INCREASED.IF THIS | | | IS NOT PROPERLY ADDRESSED, A SEPARATE | | | PERMIT WILL BE REQUIRED FOR THE ROOF. | | | | | | 12.)FLORIDA PRODUCT APPROVALS WERE | | | NOT SUBMITTED, SEE PREVIOUS LIST ITEM | | | #25.I HAVE PRINTED THE PAS FOR YOU | | | FOR SOME OF THE ITEMS, SEE ATTACHED. | | | ANY ITEMS NOT PROPERLY SUBMITTED WILL | | | REQUIRE SEPARATE PERMITS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-03-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-14 |
Time |
12:08 |
Rev Time |
5.00 |
| Received By |
shill |
Date |
2004-03-09 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2004-03-09 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE | | | STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 | | | | | | 3.)CITY OF WEST PALM BEACH MUNICIPAL | | | CODE, 94-546 (B)(1), LOWEST FLOOR | | | SHALL BE ELEVATED TO 6" ABOVE THE BASE | | | FLOOD ELEVATION.THE SURVEY SHOULD BE | | | REVISED (NOW SHOWS 7).ALSO NOTE | | | PROPOSED FINISHED FLOOR ELEVATION ON THE | | | FOUNDATION PLAN. | | | | | | 4.)PROVIDE A SOILS INVESTIGATION | | | REPORT. | | | | | | 5.)PROVIDE INFORMATION FOR THE | | | FIREPLACE AND CHIMNEY.FACTORY BUILT | | | CHIMNEYS AND FIREPLACES SHALL BE TESTED | | | IN ACCORDANCE WITH AND MEET THE | | | REQUIREMENTS OF UL127. | | | | | | 6.)ADDITIONAL FEES DUE, SEE ATTACHED | | | BZ04011273 (VALUE ADJUSTMENT, RADON). | | | | | | 7.)THE NORTH PROPERTY LINE ON THE SITE | | | PLAN SHOULD HAVE A DIMENSION OF 188.65'. | | | | | | 8.)THE ARCHITECTURE LICENSE NUMBER | | | FOR AMES DESIGN INTERNATIONAL IS TO BE | | | ON EACH SHEET.THE PRINTED NAME AND | | | LICENSE NUMBER OF THE PERSON SEALING THE | | | PLAN IS TO BE ON EACH SHEET.THE | | | NUMBER AAC001720 IS NULL AND VOID, | | | REMOVE FROM THE PLAN.THE SEAL IS TO | | | BE DATED AS WELL AS SIGNED.FAC61G1- | | | 16.003, 004. | | | | | | 9.)THERE ARE REFERENCES ON THE PLAN TO | | | THE ELEVATOR MFGR INSTRUCTIONS AND SHOP | | | DRAWINGS.PLEASE PROVIDE INSTALLATION | | | INSTRUCTIONS.INDICATE METHOD OF | | | ATTACHMENT FOR THE ELEVATOR. | | | | | | 10.)PROVIDE A DETAIL FOR THE | | | COFFERED CEILING, INCLUDING FIREBLOCKING | | | 705.3.1. | | | | | | 11.)ONE BATHROOM AT GRADE LEVEL SHALL | | | HAVE A DOOR WITH A 29" CLEAR OPENING | | | FBC11-11(1). | | | | | | 12.)GUARDRAILS/STAIRRAILS ARE TO | | | COMPLY WITH FBC1608.2.2. | | | | | | 13.)THE DECORATIVE WOOD RAILING SHOWN | | | ON SHEET 6 DOES NOT APPEAR TO COMPLY | | | WITH FBC1015.3.IS THIS A SOLID PANEL? | | | | | | 14.)TYPICAL STAIR HANDRAIL DETAIL IS | | | TO COMPLY WITH FBC1015.3 EXCEPTION 1. | | | | | | 15.)SEPARATE PERMIT REQUIRED FOR GAS. | | | | | | 16.)SHEET 11, TRUSS ANCHORING SCHEDULE | | | META24 DESIGN UPLIFT EXCEEDS THE PRODUCT | | | LIMITATION IN THE 2004 CATALOG.CHECK | | | ALL CONNECTORS. | | | | | | 17.)SHEET 13, CITY OF WEST PALM BEACH | | | IS NOT IN THE HIGH VELOCITY ZONE (NOTE | | | 3B). | | | | | | 18.)NOTE 4, DESIGN LIVE LOAD, SHEET | | | 13, PLEASE NOTE THAT THIS IS A DWELLING, | | | NOT AN APARTMENT. | | | | | | 19.)NOTE 10, SHEET 13 REFERS TO | | | PREFAB CONCRETE FLOOR SYSTEM.OTHER | | | DETAILS REFER TO WOOD FLOOR TRUSSES. | | | ADDRESS. | | | | | | 20.)SMOKE DETECTORS REQUIRED IN | | | ACCORDANCE WITH FBC905.2.2. | | | | | | 21.)THE WINDOW BUCK IS TO EXTEND | | | BEYOND THE FRAME FBC1707.4.4.2. | | | | | | 22.)PROVIDE A VALUE FOR THE WORK IN | | | THE GARAGE. | | | | | | 23.)PROVIDE THE DIMENSION FROM THE | | | GARAGE TO THE PROPERTY LINE.PROVIDE | | | THE DESIGN PRESSURE FOR THE GARAGE | | | DOOR. | | | | | | 24.)THE ENERGY CALCS GIVE A TOTAL | | | UNDER AIR SQUARE FOOTAGE OF 3844; THE | | | AREA CALCS ON SHEET 4 GIVE TOTAL A/C AS | | | 3631.CLARIFY. | | | | | | 25.)FLORIDA STATEWIDE, LOCAL OR SITE | | | SPECIFIC PRODUCT APPROVALS REQUIRED. | | | WWW.FLORIDABUILDING.ORG.IF AVAILABLE, | | | PRINT THE FLORIDA STATEWIDE PRODUCT | | | APPROVAL AND INDICATE THE PRODUCT YOU | | | ARE USING, AS WELL AS THE TEST REPORT | | | LINK IF AVAILABLE.IF A STATEWIDE | | | APPROVAL IS NOT AVAILABLE, SUBMIT AN | | | APPLICATON FOR LOCAL PRODUCT APPROVAL. | | | | | | 26.)PROVIDE A STRUCTURAL DETAIL FOR | | | THE STAIRS, INCLUDING FIREBLOCKING | | | FBC2305.1.4(3). | | | | | | 27.)PROVIDE A DRAFTSTOP SCHEDULE | | | (FLOOR FRAMING PLAN). | | | | | | 28.)PROVIDE A DETAIL FOR THE TRELLIS | | | BALCONY. | | | | | | 29.)PROVIDE INFORMATION/PRODUCT | | | APPROVAL FOR THE DECORATIVE SIDING AT | | | TOWER, REAR ELEVATION, SHEET 6. | | | | | | 30.)PROVIDE THE SIZE AND LOCATION OF | | | THE ATTIC ACCESS, FBC2309.6-7. | | | | | | 31.)ROOF SHEATHING NOTES, #18 SHEET 13 | | | ZONE 3 IS TO BE 4" O.C. EDGES, CITY OF | | | WEST PALM BEACH AMENDMENTS TO THE FBC | | | 2306.1. | | | | | | 32.)INDICATE WHICH PRODUCT YOU ARE | | | USING FOR THE GARAGE DOOR. | | | | | | 33.)THE PRODUCT APPROVAL SUBMITTED | | | FOR FIXED GLASS HAS A LIMITATION OF | | | +-60 FOR HEAT STR. 3/16 GLASS, IMPACT. | | | SOME FIXED GLASS WINDOWS ON THE PLAN | | | HAVE A DESIGN PRESSURE OF -63.7. | | | ADDRESS. | | | | | | 34.)PROVIDE DESIGN PRESSURE FOR THE | | | ROOF.NOTE THAT THE PRODUCT APPROVAL | | | SUBMITTED HAS A MAX DESIGN PRESSURE OF | | | -62.5. | | | | | | 35.)DETAIL 19, SHEET 18, REFERS TO | | | SFBC AND PBC BUILDING CODES.THE | | | GOVERNING CODE IS FBC. | | | | | | 36.)DETAIL 4-16, PRIVACY WALL FOOTER | | | CANNOT ENCROACH THE PROPERTY LINE. | | | | | | 37.)DETAIL 3-16, SPECIFY LOAD | | | REQUIREMENT, DIAMETER OF EYE BOLTS, | | | LENGTH. | | | | | | 38.)DETAIL 2-16, STUCCO OVER WIRE | | | LATH IN A VERTICAL APPLICATION TO BE | | | 7/8", FBC2504.2.2, ASTM C926. | | | | | | 39.)PROVIDE THE INSTALLATION | | | INSTRUCTIONS FOR THE GARAGE DOOR. | | | | | | 40.)DETAIL 16-17, SBP6 IS NOT IN THE | | | SIMPSON CATALOG.NAILING OF SP6 | | | CONFLICTS WITH THE CATALOG. | | | | | | 41.)DETAIL 26-18, ELEVATOR MOTOR | | | DETAIL REFERS TO MFGR SPECS AND SHOP | | | DRAWINGS, PLEASE PROVIDE. | | | | | | 42.)PROVIDE A SCHEDULE LISTING THE | | | CONNECTORS AND THE FLORIDA PRODUCT | | | APPROVAL NUMBER. | | | | | | 43.)DETAIL 21-18 REFERS TO SBC.THE | | | GOVERNING CODE IS FBC. | | | | | | 44.)SOFFIT VENTS TO COMPLY WITH FBC | | | 2309.7. | | | | | | WHEN RESUBMITTING, CLEARLY INDICATE ALL | | | CHANGES.REPLACE REVISED PAGES AND | | | SUBMIT OLD SHEETS SEPARATELY.A | | | TRANSMITTAL LETTER EXPLAINING HOW EACH | | | ITEM WAS ADDRESSED WILL EXPEDITE PLAN | | | REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-09-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-19 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-19 |
Time |
12:22 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-09-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-14 |
Time |
07:25 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-09-14 |
Time |
06:16 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-06-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-06-03 |
Time |
13:07 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-06-03 |
Time |
11:57 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-02-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-03 |
Time |
08:14 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2004-02-09 |
Time |
15:55 |
Sent To |
M |
|
| Notes |
| 2004-02-09 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING | | | INSTALLED. MAINS/BRKRS AND PANELS ARE | | | ALL TO BE RATED FOR THE AVAILABLE FAULT | | | CURRENT.PER 110.9/110.10. | | | | | | 2} PLEASE LIST ALL THE REQ'D | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE. PER 210.52D, 210.11C3 | | | | | | 3} THERE ARE 4 AHU'S ON THE ELECTRICAL | | | PLAN AND 3 ON THE MECHANICAL PLAN, | | | PLEASE CORRELATE. ALSO SEE KW RATINGS, | | | BOTH PLANS. | | | | | | 4} PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CURCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED , | | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | | | | 5} THE PLAN SHOWS AN ELEVATER BUT NO | | | EQUIPMENT FOR IT IS IN THE LOAD | | | CALCULATIONS. | | | | | | 6} PLEASE ADD SMOKE DETECTORS TO COMPLY | | | WITH 8-1.4.1.6.2. NFPA-72 AND 905.2.2 | | | FBC.SEE REVIEWED PLAN. | | | | | | 7} ALL BATH RECEPTACLES MUST COMPLY | | | WITH210.8(A)(1),GFI. | | | | | | 8} A RECEPTACLE NEEDS TO BE INSTALLED | | | INTHE "POWDER ROOM",SHEET 14.PER | | | 210.52(D). | | | | | | 9} RECEPTACLES IN THE LAUNDRY ROOM AND | | | THE SCREENED VERANDA BY THE SINK TO BE | | | GFI PER 210.8(A)(7). | | | | | | 10} ADD A RECEPTACLE AT THE CONDENSING | | | UNITS TO COMPLY WITH 210.63. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2007-01-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-20 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-20 |
Time |
13:08 |
Sent To |
B |
|
| Notes |
| 2007-01-20 13:09:12 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-10-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-27 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-27 |
Time |
14:56 |
Sent To |
B |
|
| Notes |
| 2006-10-27 14:57:17 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-10-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-11 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-11 |
Time |
16:16 |
Sent To |
B |
|
| Notes |
| 2006-10-11 16:16:51 | TO "SHILL' DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-09-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-09 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-09 |
Time |
15:21 |
Sent To |
B |
|
| Notes |
| 2006-09-09 00:00:00 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-25 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-25 |
Time |
10:49 |
Sent To |
E |
|
| Notes |
| 2006-08-25 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-11-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-28 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-28 |
Time |
11:16 |
Sent To |
P |
|
| Notes |
| 2005-11-28 00:00:00 | TO "P" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-01-13 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-13 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-13 |
Time |
11:27 |
Sent To |
B |
|
| Notes |
| 2005-01-13 00:00:00 | TO "SH" DESK/SUBMITTALS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-05 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-05 |
Time |
11:36 |
Sent To |
B |
|
| Notes |
| 2005-01-05 00:00:00 | TO "SH" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-29 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-29 |
Time |
09:51 |
Sent To |
B |
|
| Notes |
| 2004-12-29 00:00:00 | TO "SH" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-12-15 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-15 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-15 |
Time |
13:44 |
Sent To |
B |
|
| Notes |
| 2004-12-15 00:00:00 | SENT TO "SH" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-07-07 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2004-08-31 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-07 |
Time |
11:42 |
Sent To |
P |
|
| Notes |
| 2004-07-07 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-03 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-03 |
Time |
08:14 |
Sent To |
E |
|
| Notes |
| 2004-06-03 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-03-09 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-01-27 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2004-02-04 00:00:00 | 1/27/04 TO Z | | | TO SFD RACK/E |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-14 |
Time |
12:08 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-06-14 |
Time |
11:34 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-02-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-06-12 |
Time |
08:07 |
Rev Time |
0.75 |
| Received By |
rregueir |
Date |
2004-02-21 |
Time |
09:28 |
Sent To |
B |
|
| Notes |
| 2004-02-21 00:00:00 | FAILED | | | ---------------------------------------- | | | BALANCED RETURN AIR IS REQUIRED FROM ALL | | | HABITABLE AREAS OF HOUSE PER FBC(M)601.4 | | | | | | THERE IS NO VISIBLE MEANS OF RETURN AIR | | | IN THE FOLLOWING AREAS: | | | | | | 1ST FL- ALL AREAS OUTSIDE OF BEDROOMS | | | ARE SEPARATED FROM R/A BY POCKET | | | DOOR. A SEPARATE MEANS OF RETURN | | | IS REQUIRED IN LIBRARY. POCKET | | | DOORS SEPARATING FAMILY ROOM | | | AND KITCHEN FROM RETURN SHOULD | | | ALSO BE ACCOUNTED FOR. | | | | | | 2ND FL- STUDY AND DRESSING AREA SHOW NO | | | VISIBLE MEANS OF BALANCED R/A. | | | | | | PLEASE CALL ME IF YOU HAVE ANY QUESTIONS | | | RONALD J REGUEIRO 561-805-6734 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-10-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-10-02 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-10-02 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2006-10-02 00:00:00 | REVISED RISER DIAGRAM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-07-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-07-13 |
Time |
16:40 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2004-07-13 |
Time |
16:40 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-06-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-07 |
Time |
11:42 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2004-06-12 |
Time |
08:07 |
Sent To |
M |
|
| Notes |
| 2004-06-12 00:00:00 | DENIED; | | | 2ND FLOOR RISER DIAGRAM DOES NOT MATCH | | | FLOOR PLAN. MISS 1 LAV., TUB, AND SHR. | | | FROM MASTER BATHROOM. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-02-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-06-03 |
Time |
13:07 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2004-02-10 |
Time |
11:13 |
Sent To |
M |
|
| Notes |
| 2004-02-10 00:00:00 | DENIED; | | | SIZE RISER DIAGRAM BUILDING DRAIN | | | FIRST AND SECOND FLOOR AND VERTICAL | | | STACK FOR SECOND FLOOR. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-08-31 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-27 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2004-02-03 |
Time |
10:47 |
Sent To |
I |
|
| Notes |
| 2004-07-15 00:00:00 | CONTRACTOR WILL PULL SEPARATE PERMIT FOR | | | GARAGE & PROVIDE ENGINEERING CERTIFIED | | | LETTER STATING THAT WALLS FOR GARAGE IS | | | STABLE WHEN PUTTING IN FLOOR.LETTER | | | WAS PROVIDED AND ATTACHED TO PLANS MM | | 2004-02-03 00:00:00 | NOTES: NEED TO PROVIDED UTILITY EASEMENT | | | APPROVAL FOR RETAINING WALL. | | | - SEPERATE PERMIT FOR POOL & DECK | | | - TRELLIS CANNOT BE IN UTILITY EASEMENT | | | - NEED PROOF OF ENGINEERING CERTIFIED | | | LETTER STATING THAT WALLS FOR GARAGE IS | | | STABLE WHEN PUTTING IN FLOOR.THIS | | | SHOULD BE PROVIDED BEFORE PERMIT IS | | | ISSUED. CALLED CONTR AND SHAWN WILL | | | PROVIDE MM |
|
|