Plan Review Details - Permit 04011273
Plan Review Stops For Permit 04011273
Review Stop B BUILDING (STRUCTURAL)
Rev No 13 Status P Date 2007-01-23 Cont ID  
Sent By shill Date 2007-01-23 Time 15:48 Rev Time 0.00
Received By shill Date 2007-01-23 Time 15:47 Sent To  
Notes
2007-01-23 15:48:20REVISION; BEAM DETAIL AND LETTER

Review Stop B BUILDING (STRUCTURAL)
Rev No 12 Status P Date 2006-11-07 Cont ID  
Sent By shill Date 2006-11-07 Time 12:12 Rev Time 0.00
Received By shill Date 2006-11-07 Time 12:12 Sent To M
Notes
2006-11-07 12:13:04FIREPLACE DETAIL DATED 10/26/06

Review Stop B BUILDING (STRUCTURAL)
Rev No 11 Status P Date 2006-10-12 Cont ID  
Sent By shill Date 2006-10-12 Time 16:03 Rev Time 0.00
Received By shill Date 2006-10-12 Time 16:03 Sent To  
Notes
2006-10-12 16:03:40REVISE A5

Review Stop B BUILDING (STRUCTURAL)
Rev No 10 Status F Date 2006-10-12 Cont ID  
Sent By shill Date 2006-10-12 Time 09:13 Rev Time 0.00
Received By shill Date 2006-10-12 Time 08:21 Sent To PC
Notes
2006-10-12 09:00:49****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2001
  
 1.)ONLY ONE SET WAS SIGNED AND SEALED.TWO ORIGINAL
 SIGNED, SEALED, DATED SETS REQUIRED.
  
 2.)SEE PREVIOUS LIST.SHEET 05, DESIGN CRITERIA FOR
 THE GUARDRAIL IS TO COMPLY WITH FBC1608.2.NOTE THAT
 THE STARRAIL ALSO SERVES AS A GUARDRAIL, 25#/LF IS
 SPECIFIED FOR PICKETS.SEE 1608.2.2.3, 200#/SF IS
 REQUIRED.THE 25#/LF NOTE WAS NOT REMOVED FROM THE
 PLAN SO YOU NOW HAVE CONFLICTING DESIGN CRITERIA.
  
 3.)THE CHANGES TO THE PLAN WERE APPARENTLY MADE BY
 SOMEONE OTHER THAN THE ARCHITECT.HAVE THE CHANGES
 INCORPORATED INTO THE PLAN AND HAVE THE PLANS SIGNED,
 SEALED, AND DATED BY SHANE AMES AS REQUIRED BY
 FAC61G1-16.003, 004.
  
 SOMEONE NAMED HASAN HAD REPRESENTED HIMSELF AS THE
 ARCHITECT ON THE PROJECT.HIS RELATIONSHIP WITH AMES
 DESIGN INTERNATIONAL IS UNCLEAR.IF HE AN ARCHITECT
 WORKING THROUGH AMES DESIGN INTERNATIONAL, PLEASE
 CONTACT ME IN REGARDS TO THE CORRECT PROCEDURE FOR HIM
 TO MODIFY PLANS ALREADY SEALED BY ANOTHER ARCHITECT IN
 THE FIRM.HE CANNOT MAKE THE CHANGES ON THE PLAN AND
 SIGN ANOTHER ARCHITECT?S NAME ON BEHALF OF THE
 ARCHITECT.IF THE ARCHITECT ON THIS PROJECT HAS
 CHANGED, SEE FAC61G1-18.002 FOR PROCEDURES FOR A
 SUCCESSOR ARCHITECT ADOPTING ANOTHER ARCHITECT?S WORK.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status F Date 2006-09-13 Cont ID  
Sent By shill Date 2006-10-12 Time 09:13 Rev Time 0.00
Received By shill Date 2006-09-13 Time 13:30 Sent To P
Notes
2006-09-13 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 1.)SHEET 05, DESIGN CRITERIA FOR THE
 GUARDRAIL AND STAIRRAIL IS TO COMPLY
 WITH FBC1608.2.NOTE THAT THE STAIRRAIL
 ALSO SERVES AS A GUARDRAIL, 25#/LF IS
 SPECIFIED FOR PICKETS.SEE
 FBC1608.2.2.3, 200#/SF REQUIRED.
  
 INCLUDE ALL DESIGN CRITERIA FOR
 STAIRRAILS AND GUARDRAILS, FBC1608.2.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2005-01-24 Cont ID  
Sent By shill Date 2005-01-24 Time 14:06 Rev Time 0.00
Received By shill Date 2005-01-24 Time 14:06 Sent To PC
Notes
2005-01-24 00:00:00TRUSS DRAWINGS

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status F Date 2005-01-10 Cont ID  
Sent By shill Date 2005-01-10 Time 14:04 Rev Time 2.00
Received By shill Date 2005-01-10 Time 14:04 Sent To  
Notes
2005-01-10 00:00:00****CORRECTIONS****
 TRUSS DRAWING FAX
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)10# BCLL TO BE A CONCURRENT LOAD.
  
 2.)1.33 DURATION INCREASE FOR PLATES
 ACCEPTABLE.
  
 3.)PLEASE HAVE DOR CONFIRM TCDL.
  
  
 VIA TELEPHONE CONVERSATION W/TRUSS
 MANUFACTURER

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2005-01-06 Cont ID  
Sent By shill Date 2005-01-06 Time 09:52 Rev Time 2.00
Received By shill Date 2005-01-06 Time 09:52 Sent To PC
Notes
2005-01-06 00:00:00****CORRECTIONS****
 TRUSS ENGINEERING
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)THERE IS A NOTE FROM YOU DOR ON
 YOUR PLAN THAT EOR IS TO REVIEW
 STRAPPING (SHEET 10).PLEASE HAVE
 REVIEWED BEFORE RESUBMITTAL.
  
 2.)THE NEW TRUSS CALCS, ROOF, SHOW A
 STRESS INCREASE OF 1.25 FOR THE TRUSSES
 AND FOR THE PLATES.STRESS INCREASE FOR
 STEEL IS NOT PERMITTED FBC1609.4.3(2).
  
 3.)DOR HAS SPECIFIED A ROOF LIVE LOAD
 OF 30; TRUSS DRAWINGS SHOW 20.
  
 4.)INDEX SHEET SHOWS THE WRONG
 ADDRESS.THIS JOB IS NOT IN BOCA RATON.
 SECOND TIME THIS CORRECTION HAS BEEN
 MADE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2004-12-29 Cont ID  
Sent By shill Date 2004-12-29 Time 16:50 Rev Time 1.00
Received By shill Date 2004-12-29 Time 16:50 Sent To PC
Notes
2004-12-29 00:00:00****CORRECTIONS****
 TRUSS SUBMITTAL
 2ND REVIEW
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)SEE PREVIOUS LIST.ATTICS ARE IN
 THE ROOF, NOT THE FLOOR.BOTTOM CHORD
 LIVE LOAD IS TO BE 10 FOR ATTICS WITH NO
 STORAGE, 30 FOR ATTICS WITH STORAGE FBC
 TABLE 1604.1.
  
 2.)FLOOR TRUSS TOTAL LOAD SHOWN ON THE
 INDEX PAGE IS NOT CORRECT.40+10+10+10
 EQUALS 70, NOT 65.
  
 3.)PROJECT NAME AND ADDRESS ON THE
 INDEX SHEET IS INCORRECT.I ASSUME THAT
 THIS IS THE SUBCONTRACTOR; SHOULD BE THE
 PROJECT NAME AND ADDRESS.IF THIS IS
 THE PROJECT, WRONG JOB - STATES 105
 BEVERLY ROAD, BOCA RATON.
  
 4.)SOME OF THE DETAILS PROVIDED SHOULD
 EITHER BE SEALED OR REFERENCED ON THE
 INDEX SHEET.NOTE THAT THE INDEX SHEET
 DOES NOT REFER TO ALL SHEETS IN THE
 PACKAGE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2004-12-23 Cont ID  
Sent By shill Date 2004-12-23 Time 08:30 Rev Time 0.50
Received By shill Date 2004-12-23 Time 08:30 Sent To PC
Notes
2004-12-23 00:00:00****CORRECTIONS*****
 TRUSS SUBMITTAL
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)BCLL OF 10PSF REQUIRED FOR ATTICS
 WITHOUT STORAGE, 30PSF FOR ATTICS WITH
 STORAGE, FBC TABLE 1604.1.
  
 2.)ORIGINAL SIGNATURE REQUIRED, NOT A
 STAMP, FAC61G15-23.002.
  
 3.)TITLE BLOCK REQUIRED WITH ALL
 INFORMATION REQUIRED BY
 FAC61G15-23.002.
  
 4.)SOME SHEETS ARE NOT SIGNED AND
 SEALED.ALL DOCUMENTS SUBMITTED FOR
 PUBLIC RECORD PREPARED BY AND ENGINEER
 ARE TO BE SIGNED AND SEALED,
 FAC61G15-23.002.
  
 5.)PLEASE ADVISE AS TO THE STATUS FOR
 THE ENGINEERING FOR THE METAL ROOF
 (PROVISO WHEN THE PERMIT WAS ISSUED).

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-07-14 Cont ID  
Sent By shill Date 2004-07-14 Time 10:55 Rev Time 3.00
Received By shill Date 2004-07-14 Time 10:55 Sent To  
Notes
2004-07-14 00:00:00PROVISO -
 1. ENGINEERING FOR METAL ROOF TO
 BE SUBMITTED AS A REVISION.SEE ROOF
 PA.SUBMIT SKYLIGHT PRODUCT APPROVAL
 WITH ROOF.
  
 2.PROVIDE A STRUCTURAL DETAIL FOR THE
 STAIRS, INCLUDING FIREBLOCKING.
  
 3.SEPARATE PERMIT FOR ELEVATOR

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-06-15 Cont ID  
Sent By jleech Date 2004-07-13 Time 16:40 Rev Time 3.00
Received By shill Date 2004-06-15 Time 12:22 Sent To  
Notes
2004-06-15 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)THE NOTICE OF COMMENCEMENT IS
 EXPIRED (MORE THAN 90 DAYS WITHOUT
 COMMENCING WORK), FS713.13.
  
 2.)THE SURVEY SHOWS THE PROPOSED
 FINISHED FLOOR ELEVATION AS 7.1; IT
 IS REQUIRED TO BE 7.5 MIN CITY OF WEST
 PALM BEACH MUNICIPAL CODE 94-546(B)(1).
  
 3.)PROVIDE TWO ORIGINAL SEALED SOILS
 REPORTS.
  
 4.)SEE PREVIOUS LIST, PROVIDE
 INFORMATION FOR THE FIREPLACE AND
 CHIMNEY.FACTORY BUILT CHIMNEYS AND
 FIREPLACES SHALL BE TESTED IN
 ACCORDANCE WITH AND MEET THE REQUIREMENT
 OF UL127 (OR MAY BE ON SEPARATE PERMIT).
  
 5.)ADDITIONAL FEES DUE.
  
 6.)THE SEAL IS TO BE DATED AS WELL
 AS SIGNED, FAC61G1-16.003, 004.
  
 7.)SEPARATE PERMIT FOR ELEVATOR, GAS.
  
 8.)SEE PREVIOUS LIST IN REGARDS TO THE
 ENERGY CALCS.THEY SHOULD REFLECT THE
 SQUARE FOOTAGE UNDER AIR OF 3631.OR,
 IF THE PLAN UNDER AIR IS INCORRECT,
 REVISE THE PLAN TO MATCH THE ENERGY
 CALC (3844 SF) AND HAVE THE IMPACT FEE
 STAMP CHANGED TO ALSO REFLECT THE 3844
 SF.
  
 9.)SEE PREVIOUS LIST, ITEM #25.TWO
 COPIES OF ALL DOCUMENTATION (INCLUDING
 EN CALCS AND ALL PRODUCT APPROVALS) ARE
 TO BE SUBMITTED.EACH TEST REPORT IS
 TO HAVE A FLORIDA STATE, LOCAL OR SITE
 SPECIFIC PRODUCT APPROVAL.
 WWW.FLORIDABUILDING.ORG
  
 10.) ITEM #26 WAS NOT ADDRESSED (A
 STRUCTURAL DETAIL FOR THE STAIRS,
 INCLUDING FIREBLOCKING).THIS MAY BE
 ISSUED WITH A PROVISO TO PROVIDE THIS
 DETAIL BEFORE INSTALLATION.
  
 11.)SEE THE PREVIOUS LIST IN REGARDS
 TO THE ROOF PRODUCT APPROVAL (COPPER
 SALES UC3-12).I HAVE HIGHLIGHTED THE
 PERTINENT INFORMATION.THE DESIGN
 PRESSURES CAN BE INCREASED.IF THIS
 IS NOT PROPERLY ADDRESSED, A SEPARATE
 PERMIT WILL BE REQUIRED FOR THE ROOF.
  
 12.)FLORIDA PRODUCT APPROVALS WERE
 NOT SUBMITTED, SEE PREVIOUS LIST ITEM
 #25.I HAVE PRINTED THE PAS FOR YOU
 FOR SOME OF THE ITEMS, SEE ATTACHED.
 ANY ITEMS NOT PROPERLY SUBMITTED WILL
 REQUIRE SEPARATE PERMITS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-03-10 Cont ID  
Sent By pkrauss Date 2004-06-14 Time 12:08 Rev Time 5.00
Received By shill Date 2004-03-09 Time 14:33 Sent To  
Notes
2004-03-09 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE
 APPLICATION.233-5025
  
 3.)CITY OF WEST PALM BEACH MUNICIPAL
 CODE, 94-546 (B)(1), LOWEST FLOOR
 SHALL BE ELEVATED TO 6" ABOVE THE BASE
 FLOOD ELEVATION.THE SURVEY SHOULD BE
 REVISED (NOW SHOWS 7).ALSO NOTE
 PROPOSED FINISHED FLOOR ELEVATION ON THE
 FOUNDATION PLAN.
  
 4.)PROVIDE A SOILS INVESTIGATION
 REPORT.
  
 5.)PROVIDE INFORMATION FOR THE
 FIREPLACE AND CHIMNEY.FACTORY BUILT
 CHIMNEYS AND FIREPLACES SHALL BE TESTED
 IN ACCORDANCE WITH AND MEET THE
 REQUIREMENTS OF UL127.
  
 6.)ADDITIONAL FEES DUE, SEE ATTACHED
 BZ04011273 (VALUE ADJUSTMENT, RADON).
  
 7.)THE NORTH PROPERTY LINE ON THE SITE
 PLAN SHOULD HAVE A DIMENSION OF 188.65'.
  
 8.)THE ARCHITECTURE LICENSE NUMBER
 FOR AMES DESIGN INTERNATIONAL IS TO BE
 ON EACH SHEET.THE PRINTED NAME AND
 LICENSE NUMBER OF THE PERSON SEALING THE
 PLAN IS TO BE ON EACH SHEET.THE
 NUMBER AAC001720 IS NULL AND VOID,
 REMOVE FROM THE PLAN.THE SEAL IS TO
 BE DATED AS WELL AS SIGNED.FAC61G1-
 16.003, 004.
  
 9.)THERE ARE REFERENCES ON THE PLAN TO
 THE ELEVATOR MFGR INSTRUCTIONS AND SHOP
 DRAWINGS.PLEASE PROVIDE INSTALLATION
 INSTRUCTIONS.INDICATE METHOD OF
 ATTACHMENT FOR THE ELEVATOR.
  
 10.)PROVIDE A DETAIL FOR THE
 COFFERED CEILING, INCLUDING FIREBLOCKING
 705.3.1.
  
 11.)ONE BATHROOM AT GRADE LEVEL SHALL
 HAVE A DOOR WITH A 29" CLEAR OPENING
 FBC11-11(1).
  
 12.)GUARDRAILS/STAIRRAILS ARE TO
 COMPLY WITH FBC1608.2.2.
  
 13.)THE DECORATIVE WOOD RAILING SHOWN
 ON SHEET 6 DOES NOT APPEAR TO COMPLY
 WITH FBC1015.3.IS THIS A SOLID PANEL?
  
 14.)TYPICAL STAIR HANDRAIL DETAIL IS
 TO COMPLY WITH FBC1015.3 EXCEPTION 1.
  
 15.)SEPARATE PERMIT REQUIRED FOR GAS.
  
 16.)SHEET 11, TRUSS ANCHORING SCHEDULE
 META24 DESIGN UPLIFT EXCEEDS THE PRODUCT
 LIMITATION IN THE 2004 CATALOG.CHECK
 ALL CONNECTORS.
  
 17.)SHEET 13, CITY OF WEST PALM BEACH
 IS NOT IN THE HIGH VELOCITY ZONE (NOTE
 3B).
  
 18.)NOTE 4, DESIGN LIVE LOAD, SHEET
 13, PLEASE NOTE THAT THIS IS A DWELLING,
 NOT AN APARTMENT.
  
 19.)NOTE 10, SHEET 13 REFERS TO
 PREFAB CONCRETE FLOOR SYSTEM.OTHER
 DETAILS REFER TO WOOD FLOOR TRUSSES.
 ADDRESS.
  
 20.)SMOKE DETECTORS REQUIRED IN
 ACCORDANCE WITH FBC905.2.2.
  
 21.)THE WINDOW BUCK IS TO EXTEND
 BEYOND THE FRAME FBC1707.4.4.2.
  
 22.)PROVIDE A VALUE FOR THE WORK IN
 THE GARAGE.
  
 23.)PROVIDE THE DIMENSION FROM THE
 GARAGE TO THE PROPERTY LINE.PROVIDE
 THE DESIGN PRESSURE FOR THE GARAGE
 DOOR.
  
 24.)THE ENERGY CALCS GIVE A TOTAL
 UNDER AIR SQUARE FOOTAGE OF 3844; THE
 AREA CALCS ON SHEET 4 GIVE TOTAL A/C AS
 3631.CLARIFY.
  
 25.)FLORIDA STATEWIDE, LOCAL OR SITE
 SPECIFIC PRODUCT APPROVALS REQUIRED.
 WWW.FLORIDABUILDING.ORG.IF AVAILABLE,
 PRINT THE FLORIDA STATEWIDE PRODUCT
 APPROVAL AND INDICATE THE PRODUCT YOU
 ARE USING, AS WELL AS THE TEST REPORT
 LINK IF AVAILABLE.IF A STATEWIDE
 APPROVAL IS NOT AVAILABLE, SUBMIT AN
 APPLICATON FOR LOCAL PRODUCT APPROVAL.
  
 26.)PROVIDE A STRUCTURAL DETAIL FOR
 THE STAIRS, INCLUDING FIREBLOCKING
 FBC2305.1.4(3).
  
 27.)PROVIDE A DRAFTSTOP SCHEDULE
 (FLOOR FRAMING PLAN).
  
 28.)PROVIDE A DETAIL FOR THE TRELLIS
 BALCONY.
  
 29.)PROVIDE INFORMATION/PRODUCT
 APPROVAL FOR THE DECORATIVE SIDING AT
 TOWER, REAR ELEVATION, SHEET 6.
  
 30.)PROVIDE THE SIZE AND LOCATION OF
 THE ATTIC ACCESS, FBC2309.6-7.
  
 31.)ROOF SHEATHING NOTES, #18 SHEET 13
 ZONE 3 IS TO BE 4" O.C. EDGES, CITY OF
 WEST PALM BEACH AMENDMENTS TO THE FBC
 2306.1.
  
 32.)INDICATE WHICH PRODUCT YOU ARE
 USING FOR THE GARAGE DOOR.
  
 33.)THE PRODUCT APPROVAL SUBMITTED
 FOR FIXED GLASS HAS A LIMITATION OF
 +-60 FOR HEAT STR. 3/16 GLASS, IMPACT.
 SOME FIXED GLASS WINDOWS ON THE PLAN
 HAVE A DESIGN PRESSURE OF -63.7.
 ADDRESS.
  
 34.)PROVIDE DESIGN PRESSURE FOR THE
 ROOF.NOTE THAT THE PRODUCT APPROVAL
 SUBMITTED HAS A MAX DESIGN PRESSURE OF
 -62.5.
  
 35.)DETAIL 19, SHEET 18, REFERS TO
 SFBC AND PBC BUILDING CODES.THE
 GOVERNING CODE IS FBC.
  
 36.)DETAIL 4-16, PRIVACY WALL FOOTER
 CANNOT ENCROACH THE PROPERTY LINE.
  
 37.)DETAIL 3-16, SPECIFY LOAD
 REQUIREMENT, DIAMETER OF EYE BOLTS,
 LENGTH.
  
 38.)DETAIL 2-16, STUCCO OVER WIRE
 LATH IN A VERTICAL APPLICATION TO BE
 7/8", FBC2504.2.2, ASTM C926.
  
 39.)PROVIDE THE INSTALLATION
 INSTRUCTIONS FOR THE GARAGE DOOR.
  
 40.)DETAIL 16-17, SBP6 IS NOT IN THE
 SIMPSON CATALOG.NAILING OF SP6
 CONFLICTS WITH THE CATALOG.
  
 41.)DETAIL 26-18, ELEVATOR MOTOR
 DETAIL REFERS TO MFGR SPECS AND SHOP
 DRAWINGS, PLEASE PROVIDE.
  
 42.)PROVIDE A SCHEDULE LISTING THE
 CONNECTORS AND THE FLORIDA PRODUCT
 APPROVAL NUMBER.
  
 43.)DETAIL 21-18 REFERS TO SBC.THE
 GOVERNING CODE IS FBC.
  
 44.)SOFFIT VENTS TO COMPLY WITH FBC
 2309.7.
  
 WHEN RESUBMITTING, CLEARLY INDICATE ALL
 CHANGES.REPLACE REVISED PAGES AND
 SUBMIT OLD SHEETS SEPARATELY.A
 TRANSMITTAL LETTER EXPLAINING HOW EACH
 ITEM WAS ADDRESSED WILL EXPEDITE PLAN
 REVIEW.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2007-09-19 Cont ID  
Sent By btrobaug Date 2007-09-19 Time 14:02 Rev Time 0.00
Received By btrobaug Date 2007-09-19 Time 12:22 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-09-14 Cont ID  
Sent By btrobaug Date 2006-09-14 Time 07:25 Rev Time 1.00
Received By btrobaug Date 2006-09-14 Time 06:16 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-06-03 Cont ID  
Sent By btrobaug Date 2004-06-03 Time 13:07 Rev Time 0.50
Received By btrobaug Date 2004-06-03 Time 11:57 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-02-09 Cont ID  
Sent By csiegber Date 2004-06-03 Time 08:14 Rev Time 1.00
Received By btrobaug Date 2004-02-09 Time 15:55 Sent To M
Notes
2004-02-09 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING
 INSTALLED. MAINS/BRKRS AND PANELS ARE
 ALL TO BE RATED FOR THE AVAILABLE FAULT
 CURRENT.PER 110.9/110.10.
  
 2} PLEASE LIST ALL THE REQ'D
 DEDICATED BATH(S) CIRCUIT(S) ON PANEL
 SCHEDULE. PER 210.52D, 210.11C3
  
 3} THERE ARE 4 AHU'S ON THE ELECTRICAL
 PLAN AND 3 ON THE MECHANICAL PLAN,
 PLEASE CORRELATE. ALSO SEE KW RATINGS,
 BOTH PLANS.
  
 4} PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CURCUIT(S) ON PANEL
 SCHEDULE. PLEASE SEE THAT ALL "OUTLETS"
 IN BEDROOMS ARE TO BE PROTECTED ,
 INCLUDING, LTS, RECEPTS, SD'S ETC.
  
 5} THE PLAN SHOWS AN ELEVATER BUT NO
 EQUIPMENT FOR IT IS IN THE LOAD
 CALCULATIONS.
  
 6} PLEASE ADD SMOKE DETECTORS TO COMPLY
 WITH 8-1.4.1.6.2. NFPA-72 AND 905.2.2
 FBC.SEE REVIEWED PLAN.
  
 7} ALL BATH RECEPTACLES MUST COMPLY
 WITH210.8(A)(1),GFI.
  
 8} A RECEPTACLE NEEDS TO BE INSTALLED
 INTHE "POWDER ROOM",SHEET 14.PER
 210.52(D).
  
 9} RECEPTACLES IN THE LAUNDRY ROOM AND
 THE SCREENED VERANDA BY THE SINK TO BE
 GFI PER 210.8(A)(7).
  
 10} ADD A RECEPTACLE AT THE CONDENSING
 UNITS TO COMPLY WITH 210.63.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2007-01-20 Cont ID  
Sent By adarroug Date 2007-01-20 Time 13:08 Rev Time 0.00
Received By adarroug Date 2007-01-20 Time 13:08 Sent To B
Notes
2007-01-20 13:09:12TO "SHILL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2006-10-27 Cont ID  
Sent By adarroug Date 2006-10-27 Time 14:56 Rev Time 0.00
Received By adarroug Date 2006-10-27 Time 14:56 Sent To B
Notes
2006-10-27 14:57:17TO "SHILL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2006-10-11 Cont ID  
Sent By adarroug Date 2006-10-11 Time 16:16 Rev Time 0.00
Received By adarroug Date 2006-10-11 Time 16:16 Sent To B
Notes
2006-10-11 16:16:51TO "SHILL' DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2006-09-09 Cont ID  
Sent By adarroug Date 2006-09-09 Time 15:21 Rev Time 0.00
Received By adarroug Date 2006-09-09 Time 15:21 Sent To B
Notes
2006-09-09 00:00:00TO "SHILL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-08-25 Cont ID  
Sent By adarroug Date 2006-08-25 Time 10:49 Rev Time 0.00
Received By adarroug Date 2006-08-25 Time 10:49 Sent To E
Notes
2006-08-25 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2005-11-28 Cont ID  
Sent By adarroug Date 2005-11-28 Time 11:16 Rev Time 0.00
Received By adarroug Date 2005-11-28 Time 11:16 Sent To P
Notes
2005-11-28 00:00:00TO "P" BOX

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-01-13 Cont ID  
Sent By mjacobs Date 2005-01-13 Time 11:27 Rev Time 0.00
Received By mjacobs Date 2005-01-13 Time 11:27 Sent To B
Notes
2005-01-13 00:00:00TO "SH" DESK/SUBMITTALS.

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-01-05 Cont ID  
Sent By mjacobs Date 2005-01-05 Time 11:36 Rev Time 0.00
Received By mjacobs Date 2005-01-05 Time 11:36 Sent To B
Notes
2005-01-05 00:00:00TO "SH" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-12-29 Cont ID  
Sent By mjacobs Date 2004-12-29 Time 09:51 Rev Time 0.00
Received By mjacobs Date 2004-12-29 Time 09:51 Sent To B
Notes
2004-12-29 00:00:00TO "SH" DESK.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-12-15 Cont ID  
Sent By mjacobs Date 2004-12-15 Time 13:44 Rev Time 0.00
Received By mjacobs Date 2004-12-15 Time 13:44 Sent To B
Notes
2004-12-15 00:00:00SENT TO "SH" DESK.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-07-07 Cont ID  
Sent By sgraham Date 2004-08-31 Time 13:23 Rev Time 0.00
Received By csiegber Date 2004-07-07 Time 11:42 Sent To P
Notes
2004-07-07 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-06-03 Cont ID  
Sent By csiegber Date 2004-06-03 Time 08:14 Rev Time 0.00
Received By csiegber Date 2004-06-03 Time 08:14 Sent To E
Notes
2004-06-03 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-03-09 Cont ID  
Sent By mmclean Date 2004-03-09 Time 16:50 Rev Time 0.00
Received By shill Date 2004-01-27 Time 14:24 Sent To  
Notes
2004-02-04 00:00:001/27/04 TO Z
 TO SFD RACK/E

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-06-14 Cont ID  
Sent By pkrauss Date 2004-06-14 Time 12:08 Rev Time 0.35
Received By pkrauss Date 2004-06-14 Time 11:34 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-02-21 Cont ID  
Sent By jleech Date 2004-06-12 Time 08:07 Rev Time 0.75
Received By rregueir Date 2004-02-21 Time 09:28 Sent To B
Notes
2004-02-21 00:00:00FAILED
 ----------------------------------------
 BALANCED RETURN AIR IS REQUIRED FROM ALL
 HABITABLE AREAS OF HOUSE PER FBC(M)601.4
  
 THERE IS NO VISIBLE MEANS OF RETURN AIR
 IN THE FOLLOWING AREAS:
  
 1ST FL- ALL AREAS OUTSIDE OF BEDROOMS
 ARE SEPARATED FROM R/A BY POCKET
 DOOR. A SEPARATE MEANS OF RETURN
 IS REQUIRED IN LIBRARY. POCKET
 DOORS SEPARATING FAMILY ROOM
 AND KITCHEN FROM RETURN SHOULD
 ALSO BE ACCOUNTED FOR.
  
 2ND FL- STUDY AND DRESSING AREA SHOW NO
 VISIBLE MEANS OF BALANCED R/A.
  
 PLEASE CALL ME IF YOU HAVE ANY QUESTIONS
 RONALD J REGUEIRO 561-805-6734

Review Stop P PLUMBING
Rev No 4 Status P Date 2006-10-02 Cont ID  
Sent By jleech Date 2006-10-02 Time 13:27 Rev Time 0.00
Received By jleech Date 2006-10-02 Time 13:27 Sent To  
Notes
2006-10-02 00:00:00REVISED RISER DIAGRAM

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-07-13 Cont ID  
Sent By jleech Date 2004-07-13 Time 16:40 Rev Time 0.50
Received By jleech Date 2004-07-13 Time 16:40 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-06-12 Cont ID  
Sent By csiegber Date 2004-07-07 Time 11:42 Rev Time 0.50
Received By jleech Date 2004-06-12 Time 08:07 Sent To M
Notes
2004-06-12 00:00:00DENIED;
 2ND FLOOR RISER DIAGRAM DOES NOT MATCH
 FLOOR PLAN. MISS 1 LAV., TUB, AND SHR.
 FROM MASTER BATHROOM.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-02-10 Cont ID  
Sent By btrobaug Date 2004-06-03 Time 13:07 Rev Time 0.50
Received By jleech Date 2004-02-10 Time 11:13 Sent To M
Notes
2004-02-10 00:00:00DENIED;
 SIZE RISER DIAGRAM BUILDING DRAIN
 FIRST AND SECOND FLOOR AND VERTICAL
 STACK FOR SECOND FLOOR.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status P Date 2004-08-31 Cont ID  
Sent By csiegber Date 2004-01-27 Time 14:24 Rev Time 0.00
Received By sgraham Date 2004-02-03 Time 10:47 Sent To I
Notes
2004-07-15 00:00:00CONTRACTOR WILL PULL SEPARATE PERMIT FOR
 GARAGE & PROVIDE ENGINEERING CERTIFIED
 LETTER STATING THAT WALLS FOR GARAGE IS
 STABLE WHEN PUTTING IN FLOOR.LETTER
 WAS PROVIDED AND ATTACHED TO PLANS MM
2004-02-03 00:00:00NOTES: NEED TO PROVIDED UTILITY EASEMENT
 APPROVAL FOR RETAINING WALL.
 - SEPERATE PERMIT FOR POOL & DECK
 - TRELLIS CANNOT BE IN UTILITY EASEMENT
 - NEED PROOF OF ENGINEERING CERTIFIED
 LETTER STATING THAT WALLS FOR GARAGE IS
 STABLE WHEN PUTTING IN FLOOR.THIS
 SHOULD BE PROVIDED BEFORE PERMIT IS
 ISSUED. CALLED CONTR AND SHAWN WILL
 PROVIDE MM