Plan Review Details - Permit 04011145
Plan Review Stops For Permit 04011145
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-04-20 Cont ID  
Sent By jwitmer Date 2004-04-20 Time 16:49 Rev Time 0.55
Received By jwitmer Date 2004-04-20 Time 16:49 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-04-02 Cont ID  
Sent By kstevens Date 2004-04-16 Time 14:37 Rev Time 0.25
Received By jwitmer Date 2004-04-02 Time 11:23 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-03-08 Cont ID  
Sent By jwitmer Date 2004-03-08 Time 08:55 Rev Time 1.00
Received By jwitmer Date 2004-03-08 Time 08:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-03-02 Cont ID  
Sent By jwitmer Date 2004-03-02 Time 13:21 Rev Time 2.00
Received By jwitmer Date 2004-03-02 Time 13:20 Sent To PC
Notes
2004-03-02 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04011145
 ADD: 5500 N VILLAGE BLVD# 102 & 103
 CONT: BUTLER CONSTRUCTION
 TEL: (561)644-9397
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1ST REVIEW
 ACTION: DENIED
  
 1) SHEET 3.1 SUITE 102 DOOR 102-21 EXIST
 ING EXIT DOOR & EXIT DOOR FROM STAIRWELL
 OPPOSE EACH OTHER, NOT A CLEAR AND
 UNOBSTRUCTED EXIT 1001.1.3. / TABLE
 1004 CLEAR MINIMUM FOR EXIT DOORS IS
 32". SEE 1003.2.3.1.
  
 2) THIS SAME CONFIGURATION OCCURS ON
 SHEET 3.2 OPPOSITE END OF THE BUILDING
 IN SUITE 103.
  
 3) SHEET 10.1 NOTE ON KEY PAD LOCK CON-
 TROL. PROVIDE ADDITIONAL INFORMATION
 IF ELEC FAILS ?
  
 4)704.2.1.4 CORRIDOR PARTITIONS, SMOKE
 STOP PARTITIONS, HORIZONTAL EXIT PART-
 ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
 2)NOTE: PLEASE SEE BLDG PLAN REVIEW
 NOTES. PLEASE CORRELATE PLANS/PAPERWORK
 FOR COTTAGES.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-03-30 Cont ID  
Sent By btrobaug Date 2004-03-30 Time 11:25 Rev Time 1.00
Received By btrobaug Date 2004-03-30 Time 09:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-01-30 Cont ID  
Sent By dpalmer Date 2004-01-30 Time 13:36 Rev Time 0.75
Received By dpalmer Date 2004-01-30 Time 13:36 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2004-03-12 Cont ID  
Sent By mcarsill Date 2004-03-12 Time 18:34 Rev Time 0.00
Received By mcarsill Date 2004-03-12 Time 18:34 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2004-03-05 Cont ID  
Sent By mcarsill Date 2004-03-05 Time 16:13 Rev Time 0.00
Received By mcarsill Date 2004-03-05 Time 16:13 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-01-29 Cont ID  
Sent By mcarsill Date 2004-01-29 Time 07:50 Rev Time 0.00
Received By mcarsill Date 2004-01-29 Time 07:50 Sent To  
Notes
2004-01-29 00:00:001) STAIRWELL DOOR AND EXIT DOOR OPPOSE
 ONE ANOTHER AND HIT EACH OTHER IN
 SUITE 103.
  
 2) SEPARATE PLANS AND PERMITS REQUIRED
 FOR NEW FIRE ALARM EQUIPMENT.
  
 3) STAIRWELL DOOR AND EXIT DOOR OPPOSE
 ONE ANOTHER AND HIT EACH OTHER IN SUITE
 102.
  
 4) PLEASE EXPLAIN KEY PAD LOCK CONTROL
 UNDER EXIT DOORS ON PAGE 10.1.
  
 5) CUBICLE INSTALLATIONS SHALL PROVIDE
 44" CLEARANCE.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-05-12 Cont ID  
Sent By ptjomsto Date 2004-05-12 Time 08:13 Rev Time 0.00
Received By ptjomsto Date 2004-05-12 Time 08:14 Sent To  
Notes
2004-05-12 00:00:00REV GIVEN TO HAROLD PISKURA

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-04-14 Cont ID  
Sent By csiegber Date 2004-04-14 Time 09:56 Rev Time 0.00
Received By csiegber Date 2004-04-14 Time 09:56 Sent To B
Notes
2004-04-14 00:00:00TO JW DESK/SUBMITTAL/SIGNED & SEALED
 LETTERS

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-04-07 Cont ID  
Sent By csiegber Date 2004-04-07 Time 07:32 Rev Time 0.00
Received By csiegber Date 2004-04-07 Time 07:32 Sent To P
Notes
2004-04-07 00:00:00REVISION SUBMITTED

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-03-12 Cont ID  
Sent By csiegber Date 2004-03-12 Time 10:33 Rev Time 0.00
Received By csiegber Date 2004-03-12 Time 10:33 Sent To  
Notes
2004-03-12 00:00:00TO COMM BD#17

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-04 Cont ID  
Sent By csiegber Date 2004-03-04 Time 15:48 Rev Time 0.00
Received By csiegber Date 2004-03-04 Time 15:47 Sent To  
Notes
2004-03-04 00:00:00TO COMM BD#3

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-03-02 Cont ID  
Sent By csiegber Date 2004-03-02 Time 13:34 Rev Time 0.00
Received By jwitmer Date 2004-01-23 Time 15:04 Sent To PC
Notes
2004-01-23 00:00:00TO COMM BD#19

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2004-05-13 Cont ID  
Sent By pkrauss Date 2004-05-13 Time 09:20 Rev Time 0.40
Received By pkrauss Date 2004-05-13 Time 07:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-03-31 Cont ID  
Sent By pkrauss Date 2004-03-31 Time 07:42 Rev Time 0.40
Received By pkrauss Date 2004-03-31 Time 07:06 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-02-02 Cont ID  
Sent By pkrauss Date 2004-02-02 Time 07:42 Rev Time 0.50
Received By pkrauss Date 2004-02-02 Time 07:42 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-04-16 Cont ID  
Sent By kstevens Date 2004-04-16 Time 14:36 Rev Time 1.00
Received By kstevens Date 2004-04-16 Time 14:36 Sent To B
Notes
2004-04-16 00:00:00REVISION OK - ADDED ACCESSIBLE BATHROOM

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-03-23 Cont ID  
Sent By csiegber Date 2004-04-07 Time 07:32 Rev Time 1.50
Received By kstevens Date 2004-03-23 Time 09:41 Sent To  
Notes
2004-03-23 00:00:00REVISION DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) A SANITARY AND A WATER RISER DIAGRAM,
 (ISOMETRIC), ARE REQUIRED PER SECTION
 104.3.1.1.
 2) SHT P8.2 DETAIL #13 SHOW GRAB BARS
 SECTION 11-4.16.4, TOILET HEIGHT SECTION
 11-4.16.3, LAV HEIGHT AND CLEARANCES
 SECTION 11-4.19.2, EXPOSED PIPES AND
 SURFACES 11-4.19.4 ON DETAIL.
 3) PER FAC 61G1-16.004(6) A SPACE FOR
 THE PRINTED NAME OF THE PERSON SEALING
 THE DRAWINGS IS REQUIRED.
 4) PER FS 481.219(2) A CERTIFICATE OF
 AUTHORIZATION SHALL BE REQUIRED FOR A
 CORPORATION, PARTNERSHIP, OR PERSON
 PRACTICING UNDER A FICTITIOUS NAME,
 OFFERING ARCHITECTURAL SERVICES TO THE
 PUBLIC JOINTLY OR SEPARATELY.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status N Date 2004-02-02 Cont ID  
Sent By kstevens Date 2004-02-02 Time 12:49 Rev Time 0.50
Received By kstevens Date 2004-02-02 Time 12:49 Sent To  
Notes
2004-02-02 00:00:00NO PLUMBING PLANS SUBMITTED. PLUMBING
 PERMIT REQUIRED.