| Plan Review Stops For Permit 04011062 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-03-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-22 |
Time |
14:03 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-03-22 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2004-03-23 00:00:00 | PASSED 3/23 | | 2004-03-22 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SEE THE PREVIOUS LISTED, ITEM #1. | | | THE LICENSE NUMBER OF THE PERSON | | | SEALING THE PLAN IS TO BE PRINTED ON | | | EACH SHEET FAC61G1-16.THE BUSINESS | | | LICENSE NUMBER IS ON THE PLAN BUT THE | | | LICENSE NUMBER FOR THE ARCHITECT IS NOT | | | ON EACH SHEET. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-02-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-02-24 |
Time |
14:31 |
Rev Time |
3.00 |
| Received By |
shill |
Date |
2004-02-24 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2004-02-24 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE LICENSE NUMBER OF THE PERSON | | | SEALING THE PLAN IS TO BE PRINTED ON | | | EACH SHEET, FAC61G1-16. | | | | | | 2.)FBC1012.1.4, DURING ITS SWING ANY | | | DOOR IN A MEANS OF EGRESS SHALL LEAVE | | | UNOBSTRUCTED 1/2 THE REQUIRED WIDTH OF | | | THE CORRIDOR, NOR PROJECT MORE THAN 7" | | | WHEN FULLY OPEN (HC LAV. DOOR). |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-03-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-23 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2004-03-23 |
Time |
09:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-01-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-26 |
Time |
16:22 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-01-26 |
Time |
16:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-03-23 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-03-23 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-03-23 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-01-29 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-01-29 |
Time |
12:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-03-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-12 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-12 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2004-03-12 00:00:00 | TO COMM BD#42 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-02-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-02-24 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-01-22 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2004-01-22 00:00:00 | TO COMM BD#6 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-03-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-24 |
Time |
11:13 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-03-24 |
Time |
11:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-02-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-02-02 |
Time |
06:33 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-02-02 |
Time |
06:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-03-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-23 |
Time |
15:22 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-03-23 |
Time |
15:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-01-31 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-31 |
Time |
12:32 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-01-31 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2004-01-31 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A-1 SINK IN COPY ROOM SHALL COM- | | | PLY WITH SECTION 11-4.24 AND ALL SUBSEC- | | | TIONS. SUBMIT DETAIL. DOOR SHALL NOT | | | SWING INTO CLEAR FLOOR SPACE REQUIRED | | | FOR ANY FIXTURE. | | | 2) TABLE 403.1 REQUIRES A DRINKING | | | FOUNTAIN. IF AVAILABLE IN THE COMMON | | | AREA, CALL OUT ON PLANS. | | | 3) COPY ROOM SINK SHALL NOT DRAIN INTO | | | THE HORIZONTAL WET VENT OF THE BATHROOM | | | FIXTURES. 909.1 - CONNECT SINK DOWN- | | | STREAM OF BATHROOM FIXTURES ON FLOOR | | | PLAN AND RISER DIAGRAM. | | | 4) SUBMIT MANUF SPEC SHEET FOR INSTA- | | | HOT. SHALL BE LISTED BY APPROVED TESTING | | | AGENCY. | | | 5) PLUMBING FIXTURE SCHEDULE, NO SINK IS | | | SHOWN FOR COPY ROOM SINK. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|