Plan Review Details - Permit 04010918
Plan Review Stops For Permit 04010918
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-04-19 Cont ID  
Sent By rmcdouga Date 2004-04-19 Time 10:55 Rev Time 2.00
Received By rmcdouga Date 2004-04-19 Time 10:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-03-29 Cont ID  
Sent By dpalmer Date 2004-04-18 Time 07:29 Rev Time 2.00
Received By rmcdouga Date 2004-03-29 Time 08:21 Sent To  
Notes
2004-03-29 00:00:00DENIED
  
 1) EVERY SHEET OF THE PLANS IS REQUIRED
 TO HAVE THE FIRM LICENSE NUMBER IN THE
 TITLE BLOCK. SUBMIT TWO COMPLETE SETS OF
 PLANS WITH THE REQUIRED INFORMATION.
 SEE FAC 61G1-16.004.
  
 2) THE TRUSS CONNECTOR SCHEDULE ON A6
 HAS BEEN PRINTED OVER AND IS ILLEGIBLE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-03-04 Cont ID  
Sent By btrobaug Date 2004-03-24 Time 13:04 Rev Time 2.50
Received By rmcdouga Date 2004-03-04 Time 13:37 Sent To  
Notes
2004-03-04 00:00:00DENIED
  
 1) REVISE NOTE #11 UNDER PLAN NOTES ON
 C1 TO INCLUDE AREAS IN WIND BORNE DEBRIS
 REGIONS WHICH ALSO REQUIRED IMPACT
 PROTECTION FOR GLAZED OPENINGS. SEE
 FBC 1606.1.4.
  
 2) REVISE NOTE #15 UNDER FRAMING NOTES
 ON C1 TO SPECIFY THAT HIGH RIB METAL
 LATH IS REQUIRED TO BE ATTACHED AT EACH
 RIB (4"OC) PER ASTM C 1063.
  
 3) SPECIFY THE TRUSS BOTTOM CORD LIVE
 LOAD ON THE PLANS. FBC TABLE 1604.1
 REQUIRES ATTICS WITHOUT STORAGE TO HAVE
 A LIVE LOAD OF 10 PSF AND 30 PSF FOR
 ATTICS WITH STORAGE.
  
 4) ONE HOUR FIRE RATED GLASS BLOCK IS
 REQUIRED ON THE ZERO LOT LINE. PLEASE
 SPECIFY THIS ON THE PLANS.
  
 5) SOME OF THE WINDLOAD PRESSURES AND
 OPENING SIZES ARE MISSING FROM THE RIGHT
 ELEVATION ON A4.
  
 6) REVISE THE SLIDING GLASS DOOR BUCK
 DETAIL TO STATE THAT THEY ARE FASTENED
 THROUGH THE BUCK AND NOT TO THE BUCK.
 SEE FBC 1707.4.4.2.
  
 7) SPECIFY THE LENGTH/EMBED DEPTH OF THE
 1/2" ANCHOR BOLTS FOR THE GARAGE DOOR
 BUCKS ON A4.
  
 8) SPECIFY ON THE PLANS THAT THE DOOR
 FROM THE GARAGE TO CONDITIONED SPACE IS
 INSULATED OR SOLID CORE AS REQUIRED BY
 FBC CHAPTER 13 SECTION 603.
  
 9) REVISE THE SEMCO TRUSS CONNECTOR
 SPECIFIED IN DETAIL 9 ON A5 TO A CURRENT
 ANCHOR WITH STATE OR LOCAL PRODUCT
 APPROVAL.
  
 10) REVISE THE TRUSS CONNECTOR SCHEDULE
 ON A6 TO VALUES THAT DO NOT INCLUDE A
 ONE-THIRD INCREASE FOR THE STEEL
 CALCULATIONS WHICH IS NO LONGER ALLOWED
 BY FBC 1609.4. SEE CURRENT TRUSS
 CONNECTOR CATALOGS. VERIFY THAT ANCHORS
 SPECIFIED ON ROOF FRAMING PLAN WILL
 WORK WITH ADJUSTED ANCHOR VALUES.
  
 11) THE INSTALLATION DRAWING SUBMITTED
 FOR THE GARAGE DOOR IS FOR A 9' WIDE
 DOOR AND THE ONE SHOWN ON THE PLANS IS
 16' WIDE. SUBMIT THE APPROPRIATE
 INSTALLATION DRAWINGS.
  
 12) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72.
  
 13) THE STORM PANEL INSTALLATION
 SCHEDULE APPEARS TO BE IN ERROR. THE
 ANCHOR SPACING OF 6" SHOULD BE FOR ITEM
 #9 AND NOT #8.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-10-05 Cont ID  
Sent By dpalmer Date 2004-10-05 Time 06:57 Rev Time 0.25
Received By dpalmer Date 2004-10-05 Time 06:51 Sent To  
Notes
2004-10-05 00:00:00SENT OUT FRONT UNDER'C',CALLED CONT.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-04-18 Cont ID  
Sent By csiegber Date 2004-10-04 Time 13:02 Rev Time 0.25
Received By dpalmer Date 2004-04-18 Time 07:29 Sent To B
Notes
2004-04-18 00:00:00NEW ELECTRICAL SHEETS STAMPED.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-03-24 Cont ID  
Sent By kstevens Date 2004-04-17 Time 11:12 Rev Time 0.50
Received By btrobaug Date 2004-03-24 Time 12:55 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-02-03 Cont ID  
Sent By csiegber Date 2004-03-16 Time 15:33 Rev Time 0.75
Received By dpalmer Date 2004-02-03 Time 09:08 Sent To M
Notes
2004-02-03 00:00:00************** UNSAT ***************
  
 1)NOTE: PLEASE HAVE PLANS SIGNED, DATED
 AND SEALED BY THE ARCH OF RECORD.
 SIGNATURE ON PLANS DO NOT CORRELATE
 WITH SIGNATURE ON FILE FOR ARCH.
 THE ARCH HAS BEEN NOTIFIED OF SAID
 VIOLATION ON PREVIOUS PLANS. ONE SET OF
 PLANS ARE BEING RETAINED FOR SAID
 VIOLATION.
 ABOVE PER FS 481.221
  
 2)NOTE: PLEASE INCLUDELICENSE #'S
 ON TITLE BLOCK'S AS REQ'D PER 61G1-16.00
 4. THIS IS REQ'D FOR ALL SHEETS AND
 TRADES, WEATHER OR NOT COMMENT IS MADE
 BY OTHER REVIEWERS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-10-04 Cont ID  
Sent By csiegber Date 2004-10-04 Time 13:02 Rev Time 0.00
Received By csiegber Date 2004-10-04 Time 13:02 Sent To E
Notes
2004-10-04 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-04-14 Cont ID  
Sent By csiegber Date 2004-04-14 Time 11:57 Rev Time 0.00
Received By csiegber Date 2004-04-14 Time 11:57 Sent To P
Notes
2004-04-14 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-16 Cont ID  
Sent By csiegber Date 2004-03-16 Time 15:33 Rev Time 0.00
Received By csiegber Date 2004-03-16 Time 15:33 Sent To E
Notes
2004-03-16 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-03-04 Cont ID  
Sent By mmclean Date 2004-01-22 Time 16:10 Rev Time 0.00
Received By csiegber Date 2004-01-21 Time 14:04 Sent To  
Notes
2004-01-23 00:00:00TO SFD RACK/E
2004-01-21 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-02-21 Cont ID  
Sent By jleech Date 2004-02-09 Time 14:59 Rev Time 0.33
Received By rregueir Date 2004-02-21 Time 09:11 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-04-17 Cont ID  
Sent By kstevens Date 2004-04-17 Time 11:12 Rev Time 0.50
Received By kstevens Date 2004-04-17 Time 11:12 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-02-09 Cont ID  
Sent By csiegber Date 2004-04-14 Time 11:57 Rev Time 0.50
Received By jleech Date 2004-02-09 Time 14:59 Sent To M
Notes
2004-02-09 00:00:00DENIED;
 SEE ELECTRICAL PLAN REVIEW NOTES.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status P Date 2004-01-22 Cont ID  
Sent By mmclean Date 2004-01-22 Time 16:10 Rev Time 0.00
Received By mmclean Date 2004-01-22 Time 16:10 Sent To I
Notes
***NONE***