Plan Review Details - Permit 04010887
Plan Review Stops For Permit 04010887
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status N Date 2004-06-17 Cont ID  
Sent By shill Date 2004-06-17 Time 11:07 Rev Time 0.25
Received By shill Date 2004-06-17 Time 11:07 Sent To  
Notes
2004-06-17 00:00:00MEP REVISION DATED 6/7/04

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-06-04 Cont ID  
Sent By shill Date 2004-06-04 Time 08:20 Rev Time 0.50
Received By shill Date 2004-06-04 Time 08:20 Sent To  
Notes
2004-06-04 00:00:00CHILLER SLAB DETAILS, WOOD FURRING
 LETTER

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-04-14 Cont ID  
Sent By alange Date 2004-05-26 Time 09:25 Rev Time 3.00
Received By shill Date 2004-04-13 Time 10:57 Sent To  
Notes
2004-04-14 00:00:00CHANGES MADE BY ARCH & ENGINEER
 SITE SPECIFIC SUBMITTED
2004-04-13 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)SHEET E1 HAS THE PRINTED NAME AND
 LICENSE NUMBER OF BETANCOURT, PE BUT
 HAS BEEN SEALED AND SIGNED BY ME GARCIA
 PE.
  
 2.)SHEETS P1-P6 ON ONE SET ARE SIGNED
 BUT NOT SEALED.
  
 3.)THE SHEETS SEALED BY ENGINEERS ARE
 REQUIRED TO HAVE THE ENGINEER'S TITLE
 BLOCK, FAC61G15-23.002.IF GARTEK
 ENGINEERING CORP IS ON THE TITLE BLOCK,
 THE CA NUMBER IS TO BE ON EACH SHEET
 AS WELL AS THE OTHER REQUIRED
 INFORMATION.
  
 4.)SEE PREVIOUS LIST, FLORIDA STATE,
 LOCAL OR SITE SPECIFIC PRODUCT
 APPROVALS REQUIRED IN ADDITION TO
 TEST REPORTS.WWW.FLORIDABUILDING.ORG
 I HAVE EMAILED THE MANUFACTURER AT
 [email protected] REQUESTING A
 SITE SPECIFIC.IF THIS IS NOT PROVIDED
 BEFORE PERMIT ISSUANCE, A SEPARATE
 PERMIT WILL BE REQUIRED FOR THESE
 ITEMS PURSUANT TO RULE 9B-72FAC.
  
 5.)PROVIDE DESIGN PRESSURES FOR THE
 STOREFRONT GLASS.
  
 ***NO RESUB FEE FOR BUILDING COMMENTS***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-03-31 Cont ID  
Sent By shill Date 2004-03-29 Time 17:21 Rev Time 3.00
Received By shill Date 2004-03-29 Time 17:21 Sent To  
Notes
2004-03-29 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)TO EXPEDITE PLAN REVIEW, ALL
 CHANGES TO THE PLAN ARE TO BE CLEARLY
 MARKED.FOR INSTANCE, SHEET LS1, THE
 ROOM DESIGNATIONS WERE CHANGED FROM
 "CLASSROOM" TO "ROOM".THIS WAS DONE ON
 SEVERAL SHEETS, BUT NONE WERE MARKED.
  
 2.)NOTE:DAYCARE (D) OCCUPANCY AS
 PER LETTER FROM ALLAN DEUPP, MANAGER,
 PROCUREMENT & PROJECT IMPLEMENTATION
 GROUP, PALM BEACH COUNTY.
  
 3.)FBC423.21.4, TOILET FACILITIES
 SHALL HAVE A 6' IMPERVIOUS WAINSCOT.
  
 4.)PROVIDE TEST REPORTS AND FLORIDA
 STATEWIDE, LOCAL OR SITE SPECIFIC
 PRODUCT APPROVALS FOR THE EXTERIOR DOORS
 AND STOREFRONT GLASS.
 WWW.FLORIDABUILDING.ORG.
  
 5.)THE PRINTED NAME AND LICENSE
 NUMBER OF THE PERSON SEALING THE PLAN
 IS TO BE PRINTED ON EACH SHEET, FAC
 61G1-16.003.THE SEAL ON SOME SHEETS
 IS ILLEGIBLE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-02-26 Cont ID  
Sent By hpiskura Date 2004-02-26 Time 06:37 Rev Time 0.00
Received By hpiskura Date 2004-02-26 Time 06:37 Sent To  
Notes
2004-02-26 00:00:00PLAN REVIEW ONLY, NOT A PERMIT
 APPLICATION.
  
 SHEET LS1 DECLARES BUILDING TYPE AS "IV
 UNPROTECTED 1 HOUR SPRINKLERED."PLEASE
 CLARIFY.
  
 SHEET LS1 DECLARES OCCUPANCY AS DAY
 CARE.IT APPEARS THE INTENDED OCCUPANCY
 IS PRIMARILY PRE-SCHOOL, IE;
 EDUCATIONAL.SEE FBC 313.1.
  
 FBC TABLE 704.1 REQUIRES A 2 HR FIRE
 RATED MIXED OCCUPANCY SEPARATION FOR
 GROUP E OCCUPANCY.PLEASE REVISE AS
 NECESSARY.
  
 SHEET A2, DETAILS 1/A2, 2/A2 AND 3/A2.
 SHOW SPECIFIC CONNECTION METHODS FOR THE
 FRAMING TO THE EXISTING STRUCTURE.SEE
 FBC 104.2.1.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2004-07-09 Cont ID  
Sent By dpalmer Date 2004-07-09 Time 11:41 Rev Time 0.33
Received By dpalmer Date 2004-07-09 Time 11:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2004-06-23 Cont ID  
Sent By dpalmer Date 2004-06-23 Time 16:26 Rev Time 0.33
Received By dpalmer Date 2004-06-23 Time 16:26 Sent To  
Notes
2004-06-23 00:00:00********** UNSAT *************
  
 1)NOTE: PLEASE CORRELATE REVISIONS AS
 SHOWN ON TITLE BLOCKS.
 PLEASE ALSO SEE REV #5 IS NOT SHOWN ON
 PLANS AS SHOWN ON TITLE BLOCK.
 PLEASE SEE REV #4 IS SHOWN AS BEING
 BLDG DEPT COMMENTS, YET NO REVIEW OR
 COMMENTS ARE RECORDED FROM THIS OFFICE.?
  
  
 PLEASE SEE NOTES FROM PREVIOUS REVISION
 WHICH HAD COMMENTS HAVE NOT YET BEEN
 SUBMITTED FOR REVIEW.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2004-06-14 Cont ID  
Sent By csiegber Date 2004-06-18 Time 12:56 Rev Time 0.50
Received By dpalmer Date 2004-06-14 Time 16:50 Sent To  
Notes
2004-06-14 00:00:00******* UNSAT ********
  
 1)NOTE: PLEASE SEE E-3, NOTE MENTIONS
 "NEW GENERAL STORAGE" DIRECTLY INFRONT
 OF NEW ELECTRICAL PANELS? PLEASE SEE
 110.26
  
 2)NOTE: PLEASE CLARIFY GFI PROTECTION
 FOR KITCHEN RECEPTS PER 210.8B3
 ALL 125V 15/20A.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected].

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-03-26 Cont ID  
Sent By btrobaug Date 2004-03-26 Time 09:19 Rev Time 1.00
Received By btrobaug Date 2004-03-26 Time 07:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-01-26 Cont ID  
Sent By dpalmer Date 2004-01-26 Time 15:08 Rev Time 2.00
Received By dpalmer Date 2004-01-26 Time 13:46 Sent To  
Notes
2004-01-26 00:00:00************* UNSAT ********
  
 PLANS ONLY IN FOR PLAN REVIEW
  
 1)NOTE: PLEASE CLARIFY NEW OR EXISTING
 RECEPT FOR A/C EUIIPMENT. 210.63
  
 2)NOTE: PLEASE SHOW ALL CONTINOUS LOADS
 AT 125% , ALSO LARGEST MOTOR.
 215.3, 230.42 ETC
  
 3)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2004-02-12 Cont ID  
Sent By drunnels Date 2004-02-12 Time 11:02 Rev Time 0.00
Received By drunnels Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2004-03-23 Cont ID  
Sent By mcarsill Date 2004-03-23 Time 16:57 Rev Time 0.00
Received By mcarsill Date 2004-03-23 Time 16:57 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-01-22 Cont ID  
Sent By mcarsill Date 2004-01-22 Time 16:16 Rev Time 0.00
Received By mcarsill Date 2004-01-22 Time 16:16 Sent To  
Notes
2004-01-22 00:00:001) DEMOLITION, RENOVATION, AND
 CONSTRUCTION SHALL COMPLY WITH
 NFPA 241.
  
 2) DEBRIS SHALL BE REMOVED FROM THE
 BUILDING DAILY.
  
 3) ALL CLOSET AND BATHROOM DOOR LOCKS
 SHALL BE OPENABLE FROM THE OUTSIDE.
  
 4) PANIC HARDWARE SHALL BE PROVIDED
 ON DOORS WITH AN OCCUPANT LOAD OF 100
 OR MORE PERSONS.
  
 5) PLEASE INDICATE INTERIOR FINISH
 CLASSIFICATION FOR WALLS AND CEILINGS.
  
 6) ENSURE BUILDING ADDRESS IS AVAILABLE.
 A MINIMUM OF 6" HIGH NUMBERS ARE
 REQUIRED.
  
 7) SEPARATE PLANS AND PERMITS
 REQUIRED FOR FIRE SPRINKLER REMODEL.
  
 8) SEPARATE PLANS AND PERMITS REQUIRED
 FOR NEW FIRE ALARM EQUIPMENT.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2004-08-26 Cont ID  
Sent By csiegber Date 2004-08-26 Time 15:49 Rev Time 0.00
Received By csiegber Date 2004-08-26 Time 15:49 Sent To P
Notes
2004-08-26 00:00:00TO KS BOX/RE

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2004-08-12 Cont ID  
Sent By csiegber Date 2004-08-12 Time 15:23 Rev Time 0.00
Received By csiegber Date 2004-08-12 Time 15:22 Sent To P
Notes
2004-08-12 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2004-07-02 Cont ID  
Sent By csiegber Date 2004-07-02 Time 13:26 Rev Time 0.00
Received By csiegber Date 2004-07-02 Time 13:26 Sent To  
Notes
2004-07-02 00:00:00TO COMM BD#10

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-06-18 Cont ID  
Sent By csiegber Date 2004-06-18 Time 12:56 Rev Time 0.00
Received By csiegber Date 2004-06-18 Time 12:56 Sent To E
Notes
2004-06-18 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-06-08 Cont ID  
Sent By csiegber Date 2004-06-08 Time 15:17 Rev Time 0.00
Received By csiegber Date 2004-06-08 Time 15:17 Sent To  
Notes
2004-06-08 00:00:00TO COMM BD#21

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-05-26 Cont ID  
Sent By alange Date 2004-05-26 Time 09:25 Rev Time 0.00
Received By alange Date 2004-05-26 Time 09:25 Sent To B
Notes
2004-05-26 00:00:00TO SH DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-04-07 Cont ID  
Sent By csiegber Date 2004-04-07 Time 15:26 Rev Time 0.00
Received By csiegber Date 2004-04-07 Time 15:26 Sent To  
Notes
2004-04-07 00:00:00TO COMM BD#15

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-23 Cont ID  
Sent By csiegber Date 2004-03-23 Time 09:49 Rev Time 0.00
Received By csiegber Date 2004-03-23 Time 09:49 Sent To  
Notes
2004-03-23 00:00:00TO COMM BD#16

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-26 Cont ID  
Sent By shill Date 2004-04-13 Time 08:00 Rev Time 0.00
Received By shill Date 2004-01-20 Time 16:04 Sent To  
Notes
2004-01-20 00:00:00TO COMM BD#36

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2004-07-12 Cont ID  
Sent By pkrauss Date 2004-07-12 Time 12:05 Rev Time 0.55
Received By pkrauss Date 2004-07-12 Time 11:46 Sent To  
Notes
2004-07-12 00:00:00PROVISO:
 PLAN SHEET M-4 INDICATES KEF-1 FROM
 THE DISHWASHER HOOD TERMINATING AT THE
 WALL.TERMINATION SHALL COMPLY WITH THE
 FOLLOWING SECTIONS FROM THE 2001 FBC(M),
 506.4.1, 401.5, & 401.5.2.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2004-06-16 Cont ID  
Sent By pkrauss Date 2004-06-16 Time 09:37 Rev Time 0.40
Received By pkrauss Date 2004-06-16 Time 07:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-03-31 Cont ID  
Sent By pkrauss Date 2004-03-31 Time 15:08 Rev Time 0.45
Received By pkrauss Date 2004-03-31 Time 14:50 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-02-02 Cont ID  
Sent By pkrauss Date 2004-02-02 Time 10:53 Rev Time 1.00
Received By pkrauss Date 2004-02-02 Time 10:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 7 Status P Date 2004-09-01 Cont ID  
Sent By kstevens Date 2004-09-01 Time 15:47 Rev Time 1.00
Received By kstevens Date 2004-09-01 Time 15:47 Sent To  
Notes
2004-09-01 00:00:00REVISION OK - PIPING FOR KITCHEN AREA
 AND GAS PIPING OK

Review Stop P PLUMBING
Rev No 6 Status F Date 2004-08-18 Cont ID  
Sent By csiegber Date 2004-08-26 Time 15:50 Rev Time 1.25
Received By kstevens Date 2004-08-18 Time 16:41 Sent To  
Notes
2004-08-18 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
  
 1) SHTS P7 & P8 HUB DRAIN NOT APPROVED
 FOR INDIRECT WASTE FOR DISHWASHER. HUB
 DRAINS ARE APPROVED FOR CLEAR WASTE ONLY
 AND A FLOOR SINK IS REQUIRED FOR THE
 DISCHARGE FROM A DISHWASHER. SECTION
 802.3
 2) FROM PREVIOUS REVIEW: SHT P8 WATER
 ISOMETRIC, WATER HAMMER ARRESTORS SHALL
 BE LOCATED IN AN "EFFECTIVE RANGE" NOT
 IN THE CEILING AS SHOWN. PDI-WH 201 AND
 MANUF. INSTALLATION INSTRUCTIONS WHICH
 FROM THE INFORMATION SUBMITTED STATES,
 "AS CLOSE TO THE VALVE(S) AS POSSIBLE.
 RESPONSE NOTED, BUT NOT APPROVED.
 3) EMERGENCY HOOD SHUT DOWN SHUT OFF
 VALVE TO BE BELOW CEILING. MANUAL SHUT
 OFF VALVE TO BE UPSTREAM. UNION TO BE
 DOWN STREAM OF MANUAL VALVE. FROM PRE-
 VIOUS REVIEW: RESPONSE NOTED, BUT NOT
 APPROVED.
 4) SHUT OFF VALVES TO GAS APPLIANCES
 SHALL BE FULL SIZE AS THE PIPE REQUIRED
 TO SUPPLY THE APPLIANCE. SEE RED LINE
 CORRECTIONS FOR SHUT OFF VALVE SIZE.
 MAKE CORRECTIONS AND RESUBMIT PLANS.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 5 Status F Date 2004-07-27 Cont ID  
Sent By csiegber Date 2004-08-12 Time 15:23 Rev Time 1.50
Received By kstevens Date 2004-07-27 Time 10:11 Sent To  
Notes
2004-07-27 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 1
 CITY CODE
  
 1) SHT P-2 NO REVISION #3 FOUND. PLEASE
 CLARIFY.
 2) SHT P-3 NO REVISION #3 FOUND. PLEASE
 CLARIFY.
 3) SHT P-7 DEMO'D PIPES SHALL BE INSPTE-
 TED PRIOR TO COVERING. - ALSO IN THE IN-
 STALLATION OR REMOVAL OF ANY PART OF A
 DRAINAGE SYSTEM, DEAD ENDS SHALL BE PRO-
 HIBITED. SECTION 704.5
 4) SHT P-7 DISH WASHERS SHALL BE CONNEC-
 TED TO SANITARY SYSTEM, NOT GREASE SYST-
 EM. CITY CODE.
 5) SHT P-8 WATER ISOMETRIC, WATER HAMMER
 ARRESTORS SHALL BE LOCATED IN AN "EFFEC-
 TIVE RANGE" NOT IN THE CEILING. PDI-WH
 201 AND MANUF. INSTALL. INSTRUCTIONS.
 6) THE FOLLOWING INFORMATION IS REQUIRED
 FOR GAS PERMIT. SEPERATE GAS PER REQUIR-
 ED.
 A. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2001 FUEL GAS CODE SECS. 401.8
 THRU 402.5.2 AND TABLES 402(1) THRU
 402(34).
 B. SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER FBC-2001 FUEL
 GAS CODE SECTION 304.
 C. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2001 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2001 FUEL GAS CODE SEC 402.2
 E. EMERGENCY HOOD SHUT DOWN SHUT OFF
 VALVE TO BE BELOW CEILING. MANUAL SHUT
 OFF VALVE TO BE UPSTREAM. UNION TO BE
 DOWN STREAM OF MANUAL VALVE.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 4 Status F Date 2004-06-19 Cont ID  
Sent By kstevens Date 2004-06-19 Time 07:52 Rev Time 0.50
Received By kstevens Date 2004-06-19 Time 07:52 Sent To  
Notes
2004-06-19 00:00:00REVISION DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) REVISIONS SHALL BE ROUTED TO THE PALM
 BEACH COUNTY HEALTH DEPT. DIVISION OF
 ENVIRONMENTAL HEALTH FOR REVIEW PRIOR TO
 REVIEW BY CITY WPB. SECTION 101.4.7
 2) REVISIONS STATE "REVISED PER BLDG.
 DEPT. COMMENTS. WHEN RESUBMITTING PLANS
 SUBMIT COPY OR BLDG. DEPT. COMMENTS THAT
 REQUIRED REVISIONS. SECTION 104.2.1.
 3) SEPARATE GAS PERMIT WILL BE REQUIRED.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-04-15 Cont ID  
Sent By kstevens Date 2004-04-15 Time 16:57 Rev Time 2.00
Received By kstevens Date 2004-04-15 Time 16:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-03-25 Cont ID  
Sent By kstevens Date 2004-03-25 Time 16:34 Rev Time 7.00
Received By kstevens Date 2004-03-25 Time 16:34 Sent To  
Notes
2004-03-25 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 ADA ACCESSIBILITY GUIDELINES
 BLDG. ELEMENTS DESIGNED FOR
 CHILDREN'S USE
  
 A) COMMENTS FROM PREVIOUS REVIEW HAVE
 NOT BEEN RESPONDED TO SUFFICIENTLY. THE
 NUMBER OF THE COMMENT SHALL STAY THE
 SAME AS ORIGINAL REVIEW TO PREVENT CON-
 FUSION.
 1) SHT A1 SECTION 11-4.1(6) IF TOILET
 FACILITIES ARE PROVIDED ON A SITE, THEN
 EACH SUCH PUBLIC OR COMMON USE TOILET
 FACILITIY SHALL COMPLY WITH 11-4.22.
 TOILET ROOMS 116, 120, 124, AND 147
 SHALL COMPLY WITH 11-4.16, 11-4.18, AND
 11-4.22 AND ALL SUBSECTIONS. SUBMIT A
 DETAIL SHOWING COMPLIANCE. - RESPONSE
 NOTED. BUILDING OFFICIAL STATED THAT ALL
 TOILET ROOMS SHALL COMPLY WITH ADA GUID-
 LINES FOR BUILDING ELEMENTS DESIGNED FOR
 CHILDREN'S USE. 4.16.7(2) RECOMMENDS W/C
 SEAT HEIGHT BE 12" FOR AGES 3 AND 4, BUT
 ATTACHED SHEET SHOWS 10". 4.16.7 RECOMM-
 ENDS CENTERLINE OF W/C TO BE 12" OFF THE
 WALL. SECTION 4.16(7) RECOMMENDS A GRAB
 BAR HEIGHT BETWEEN 18" & 20". ATTACHED
 SHEET SHOWS 22" AND NOT GRAB BARS ARE
 SHOWN IN TOILET ROOMS MENTIONED ABOVE.
 FLUSH CONTROLS SHALL BE A MAXIMUM HEIGHT
 OF 36" FOR W/C'S SERVING CHILDREN AGES
 2 TO 4. 4.16.7(5) TOILET PAPER DISPENS-
 ERS TO BE 14" TO 19".
 2) PLANS SHALL BE ROUTED TO THE PALM
 BEACH COUNTY HEALTH UNIT DIVISION OF
 ENVIRONMENTAL HEALTH, 901 EVERNIA STREET
 WPB 33401. (561) 355-3018 PRIOR TO RE-
 SUBMITTING TO CITY OF WPB FOR REVIEW.
 SECTION 101.4.7. - RESPONSE NOTED, BUT
 NO STAMP FROM THE HEALTH DEPT. WAS FOUND
 ON SHEET A-1.
 3) SHT A4 ACCESSIBLE TOILET DETAILS.
 SUBMIT INFORMATION ON TA-6 TOILET PAPER
 DISPENSER SHOWING ADA APPROVAL. PAPER
 DISPENSER IS ENCHROACHING INTO THE CLEAR
 FLOOR SPACE FOR W/C. 11-4.18.2 - RESPON-
 SE NOTED, BUT NO CUT SHEETS WERE FOUND.
 11) EACH WATER CLOSET UTILIZED BY THE
 PUBLIC OR EMPLOYEES SHALL OCCUPY A SEP-
 ARATE COMPARTMENT WITH A DOOR AND WALLS
 OR PARTITIONS BETWEEN FIXTURES TO EN-
 SURE PRIVACY. SECTION 310.4 - RESPONSE
 NOTED. IS ARTICLE X PHYSICAL FACILITIES,
 E) TOILET AND BATH FACILITIES, P.37 AN
 EXEMPTION TO THE CODE? PLEASE PROVIDE
 THIS INFORMATION.
 12) WATER CLOSET COMPARTMENTS SHALL NOT
 BE LESS THAN 30" WIDE AND 60" DEEP. -
 RESPONSE NOTED.SEE COMMENT #11.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-02-05 Cont ID  
Sent By kstevens Date 2004-02-05 Time 14:10 Rev Time 6.00
Received By kstevens Date 2004-02-05 Time 14:09 Sent To  
Notes
2004-02-05 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTPER 1
 FBC-2001 CHAPTER 11
 ADA ACCESSIBILITY GUIDELINES
 FOR BLDGS AND FACILITIES;
 BUILDING ELEMENTS DESIGN-
 ED FOR CHILDRES'S USE
  
 1) SHT A1 SECTION 11-4.1(6) IF TOILET
 FACILITIES ARE PROVIDED ON A SITE, THEN
 EACH SUCH PUBLIC OR COMMON USE TOILET
 FACILITY SHALL COMPLY WITH 11-4.22.
 TOILET ROOMS 116, 120, 124, AND 147
 SHALL COMPLY WITH 11-4.16, 11-4.18, AND
 11-4.22 AND ALL SUBSECTIONS. SUBMIT A
 DETAIL SHOWING COMPLIANCE.
 2) PLANS SHALL BE ROUTED TO THE PALM
 BEACH COUNTY HEALTH UNIT DIVISION OF
 ENVIRONMENTAL HEALTH, 901 EVERNIA STREET
 WPB 33401. (561) 355-3018 PRIOR TO RE-
 SUBMITTING TO CITY OF WPB FOR REVIEW.
 SECTION 101.4.7
 3) SHT A4 ACCESSIBLE TOILET DETAILS.
 SUBMIT INFORMATION ON TA-6 TOILET PAPER
 DISPENSER SHOWING ADA APPROVAL. PAPER
 DISPENSER IS ENCHOACHING INTO CLEAR
 FLOOR SPACE FOR W/C. 11-4.16.2
 4) SHT A4 DETAIL 1/A4(B) SHOW URNAL
 HEIGHT FOR URINAL PER 11-4.18.2.
 5) SHT A4 SHOW CLEAR FLOOR SPACE FOR
 URINAL ON PLAN ENLARGMENT PER SECTION
 11-4.18.3.
 6) SUBMIT CALCULATIONS FOR MINIMUM FIX-
 TURES, (FACILITIES), PER TABLE 403.1 IN
 PLUMBING AND TABLE 1003.1 IN BUILDING.
 7) SHT P-1 DEMO NOTES: ALL CAPPED PLUMB-
 ING LINES SHALL BE INSPECTED PRIOR TO
 COVERING.
 8) SHT P-1 PLUMBING SPECIFICATIONS #4(B)
 DIELECTRIC UNIONS ARE NOT APPROVED FOR
 WATER USE. DELET FROM REFERENCE.
 9) SHT P-5 WATER ISOMETRIC AT TOILET
 ROOMS 124, 120 & PUBLIC RESTROOMS. WATER
 HAMMER ARRESTORS SHALL BE LOCATED NEAR
 THE FIXTURES IN AN "EFFECTIVE RANGE" NOT
 IN THE CEILING AS SHOWN. PDI-WH 201 AND
 MANUF. INSTALLATION INSTRUCTIONS. 604.9
 (ALSO SEE #137 IN CORRIDOR).
 10) SHT P-6 FLOOR MOUNTED ELECTRIC WATER
 HEATER DETAIL. THERMAL EXPANSION CONTROL
 REQUIRED PER SECTION 607.3.2. PROVIDE A
 DETAIL.
 11) EACH WATER CLOSET UTILIZED BY THE
 PUBLIC OR EMPLOYEES SHALL OCCUPY A SEP-
 ARATE COMPARTMENT WITH A DOOR AND WALLS
 OR PARTITIONS BETWEEN DIXTURES TO EN-
 SURE PRIVACY. SECTION 310.4
 12) WATER COLSET COMPARTMENTS SHALL NOT
 BE LESS THAN 30" WIDE AND 60" DEEP.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2004-04-08 Cont ID  
Sent By jroach Date 2004-04-08 Time 13:46 Rev Time 0.00
Received By jroach Date 2004-04-08 Time 13:46 Sent To  
Notes
2004-04-08 00:00:004/8/2004 - APPROVED.JOHN ROACH,
 PLANNER 659.8031

Review Stop Z ZONING
Rev No 2 Status F Date 2004-03-30 Cont ID  
Sent By jroach Date 2004-03-30 Time 12:00 Rev Time 0.00
Received By jroach Date 2004-03-30 Time 12:00 Sent To  
Notes
2004-03-30 00:00:003/30/2004 - DENIED: NEW LANDSCAPING MUST
 BE INSTALLED ACCORDING TO CITY CODE AND
 EXISTING LANDSCAPING THAT HAS DIED MUST
 BE REPLACED.PROPOSED SIGN MUST BE
 APPROVED UNDER A SEPARATE PERMIT.
 CALLED CONTRACTOR.JOHN ROACH, PLANNER
 659.8031

Review Stop Z ZONING
Rev No 1 Status N Date 2004-02-12 Cont ID  
Sent By drunnels Date 2004-02-12 Time 11:03 Rev Time 0.00
Received By drunnels Date   Time   Sent To  
Notes
***NONE***