| Plan Review Stops For Permit 04010749 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2004-10-14 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2004-10-14 |
Time |
09:06 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-10-14 00:00:00 | APPROVE TRUSS ENGINEERING |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2004-08-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-05 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2004-06-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-16 |
Time |
16:39 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-06-14 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2004-06-14 00:00:00 | RFI 19, 38, LETTER RE:MISC FIELD ITEMS | | | PREPARED BY JOHNSON STRUCTURAL, 6/9/4 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2004-06-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-11 |
Time |
09:06 |
Rev Time |
1.50 |
| Received By |
shill |
Date |
2004-06-10 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2004-06-10 00:00:00 | STRUCTURAL REVISION - S2.0, 2.1, 2.3, | | | 3.3, 4.0, 4.1 DATED 6/3/04 REV #4 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2004-06-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-06-09 |
Time |
11:24 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-06-09 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2004-06-09 00:00:00 | LETTER FROM JOHNSON STRUCTURAL GROUP | | | APPROVAL TO POUR PORTE COCHERE AS | | | SECONDARY POUR, DATED 6/7/04 | | | | | | SHORING/RESHORE PLAN PREPARED BY HECTOR | | | VERGARA, PE DATED 5/19/04 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-06-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-08 |
Time |
13:24 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-06-04 00:00:00 | SHORING SHOP DRAWINGS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-05-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-27 |
Time |
11:39 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-05-20 00:00:00 | REVISIONS APPROVED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-03-31 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-17 |
Time |
08:33 |
Rev Time |
1.00 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-03-23 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2004-03-23 |
Time |
18:04 |
Rev Time |
5.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-03-23 00:00:00 | | | | BUILDING REVIEW COMMENTS | | | ------------------------ | | | | | | | | | 1] | | | PRODUCT APPROVAL REPORTS ARE NOT | | | COMPLETE. | | | | | | 2] | | | SEE FBC 105.13.4.4, STATEMENT IN THIS | | | SECTION SHALL BE ON THE APPROVED | | | DOCUMENTS SIGNED AND SEALED. THRESHOLD | | | INSPECTOR SHALL BE APPROVED BY CITY | | | INSPECTION STAFF, PLEASE CONTACT HAROLD | | | PISKURA AT 805-6665. | | | | | | 3] | | | SHEETS A-29 AND A-26 CALL FOR CROWN | | | MOLDINGS ON EXTERIOR? | | | | | | 4] | | | ADDITIONAL FEES DUE; | | | COUNTY IMPACT FEES. | | | CITY PERMIT FEES. | | | | | | | | | | | | | | | REVIEWED BY: | | | LUIS MARTINEZ | | | 561-805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-02-26 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2004-02-26 |
Time |
17:15 |
Rev Time |
12.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-02-26 00:00:00 | | | | BUILDING REVIEW COMMENTS | | | ------------------------ | | | | | | | | | 1] | | | SUBMIT 3 SIGNED AND SEALED SURVEYS. | | | A SIGNED AND SEALED ELEVATION | | | CERTIFICATE SHALL BE REQUIRED. FLOOD | | | ZONE A-9. | | | | | | 2] | | | PROVIDE SIGNED AND SEALED SOILS | | | INVESTAGATION REPORT FOR REVIEW. | | | | | | 3] | | | SUBMIT DOOR HARDWARE INFORMATION. | | | | | | 4] | | | PROVIDE INTERIOR DESIGNERS PLAN FOR | | | DIMENSIONS AND LAYOUT FOR THE FIRST | | | FLOOR COMMON AREAS. | | | | | | 5] | | | SUBMIT STATE OF FLORIDA PRODUCT | | | APPROVAL REPORTS FOR ALL EXTERIOR | | | GLAZING, DOORS AND ROOF COVERINGS. | | | | | | 6] | | | PROVIDE A SIGNED AND SEALED THRESHOLD | | | BUILDING PLAN FOR APPROVAL. | | | | | | 7] | | | SUBMIT SPRINKLER LAYOUT SIGNED AND | | | SEALED BY A FLORIDA REGISTERED FIRE | | | SPRINKLER DESIGN PROFESSIONAL AS PER | | | SECT. 553.79 FL. BUILDING CODES AND | | | STANDARDS. | | | | | | 8] | | | EXTERIOR ARCHITECTURAL TRIM FOAM | | | MOLDINGS ARE NOT PERMITTED, SEE SECTION | | | 1404.1 2001 F.B.C. | | | | | | 9] | | | PUBLIC SWIMMING POOL WILL BE REVIEWED | | | UNDER SEPERATE PERMIT. | | | | | | 10] | | | SECTIONS CALLED OUT ON SHEET A-23 | | | REFERENCEING SHEET A-24 AND A-30 ARE | | | INCORRECT. | | | | | | 11] | | | THE ASSIGNED ADDRESS TO YOUR PROJECT IS | | | 1601 WORTHINGTON RD. | | | | | | 12] | | | ADDITIONAL FEES DUE; | | | COUNTY IMPACT FEES | | | CITY PERMIT FEES | | | | | | | | | | | | | | | | | | REVIEWED BY: | | | LUIS MARTINEZ | | | 561-805-6710 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-01-24 |
Time |
09:11 |
Rev Time |
2.00 |
| Received By |
jleahy |
Date |
2005-01-24 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2005-01-24 00:00:00 | PUT OUT FRONT FOR PICKUP JL1/24/05 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2004-12-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-20 |
Time |
13:46 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-12-03 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2004-12-03 00:00:00 | NOTES, | | | PLEASE SEE REVISED AIC RATINGS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2004-09-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-16 |
Time |
07:20 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-09-16 |
Time |
07:06 |
Sent To |
|
|
| Notes |
| 2004-09-16 00:00:00 | LTR FOR THE PERMITTED USE OF ENT. | | | PER NEC. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2004-09-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-16 |
Time |
07:02 |
Rev Time |
1.01 |
| Received By |
dpalmer |
Date |
2004-09-15 |
Time |
07:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-08-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-30 |
Time |
10:28 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-08-18 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2004-08-18 00:00:00 | LETTER FOR MC CABLE FOR BRANCH CIRCUITS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-08-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-13 |
Time |
10:02 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2004-08-12 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2004-08-13 00:00:00 | ************ UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE THERE ARE SOME SHEETS | | | WHERE A REVISION IS NOTED ON TITLE | | | BLOCK, BUT WAS NOT ABLE TO LOCATE A | | | REV#/CLOUD/TRIANGLE ON PLAN. | | | SHEETS: E-3,E-4,E-11 | | | | | | 2)NOTE: PLEASE SEE NEW PANELS NOW WHICH | | | HAVE BEEN ADDED TO RISER. 2R2,3R3,4R4, | | | THESE PANELS WERE ADDED ON PREVIOUS | | | REVISED PLANS HOWEVER THERE IS NO | | | INDICATION ON PANELS 2R2,3R2,4R2 IF THEY | | | ALSO CONATIN FEED-THRU LUGS OR IF THESE | | | PANELS CONTAIN OCP FOR SUB-FEEDS? | | | **PLEASE ALSO SEE THESEPANELS ARE NOT | | | INCLUDED ON FLR PLANS FOR ELECTRICAL | | | ROOMS. | | | | | | 3)NOTE: PLEASE SEE NOTE # 7 FROM FIRST | | | REVIEW. PANEL LR IS STILL BEING SHOWN | | | AS BEING A 100A RATED PANEL WITH A 125A | | | FEED FROM MDP. PLEASE SEE MDP SCHEDULE | | | WHICH INDICATES 125A BRKR. | | | THIS WAS NOT CORRECTED FROM FIRST REVIEW | | | 408.13 | | | | | | 4)NOTE:PLEASE ADD NOTE WIND LOADS TO | | | MEET 140MPH ON SITE PLAN ELECTRICAL | | | LT POLES. | | | | | | **POOL UNDER SEPARATE PERMIT, INCLUDING | | | ELECTRICAL. | | | AN ELECTRICAL WILL BE REQUIRED AT THAT | | | TIME WITH A SEPARATE POOL EQUIPMENT | | | WIRING DIAGRAM. | | | **THIS IS ONLY A NOTE*** | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AN | | | ONLY INSERT NEW REVISED SHEEST INTO | | | COMPLETED SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SEE POSSIBLE COMMENTS FROM OTHER | | | REVIEWERS WHICH MAY HAVE AN AFFECT ON | | | ELECTRICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-03-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-10 |
Time |
07:48 |
Rev Time |
2.00 |
| Received By |
btrobaug |
Date |
2004-03-18 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-29 |
Time |
07:39 |
Rev Time |
3.00 |
| Received By |
dpalmer |
Date |
2004-01-28 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2004-01-29 00:00:00 | ************** UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE FIRE REVIEW NOTESAND | | | NOTES FROM OTHER REVIEWERS THAT MAY HAVE | | | AN AFFECT ON ELECTRICAL PLANS. | | | | | | 2)NOTE: PLEASE SEE PANEL EQA IS SHOWN | | | ON RISER BUT COULD NOT BE LOCATED ON | | | PLANS. | | | | | | 3)NOTE: PLEASE ALSO SEE PANELS SHOWN | | | ON RISER FOR 2ND, 3RD, AND 4TH FLR | | | COULD NOT BE LOCATED ON PLANS. | | | | | | 4)NOTE: PLEASE CLARIFY LOCATION FOR | | | A/C EQUIPMENT. 210.63 | | | | | | 5)NOTE: PLEASE SEE RISER SHOWS TWO | | | "MAINS 1 OF 2". (MISPRINT) | | | | | | 6)NOTE: PLEASE SEE PANEL 1R1. RISER | | | APPEARS TO SHOW THIS FEEDING1R2 BUT | | | PANEL DOES NOT INDICATE BEING "FEED THRU | | | LUGS". PLEASE CLARIFY. | | | | | | 7)NOTE: PLEASE CORRELATE ALL PANELS ON | | | RISER DIAGRAM WITH INFORMATION GIVEN | | | ON PANEL SCHEDULES. MANY PANELS ON | | | RISER ARE SHOWN W/ DIFFERENT AMPERAGE | | | RATINGS,THAN WHAT IS SHOWN ON PANELS. | | | EQA,EQ,LDY,L,LR,4AC2,3AC2,2AC2 . | | | PLEASE SEE LR SHOWN AS 100 WITH 125A | | | FEED. | | | | | | 8)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | AIC RATING IS SHOWN FOR MAIN, HOWEVER NO | | | INFORMATION FOR PANEL AND BRANCH BRKRS | | | ARE SHOWN. THYE ARE BLANK. | | | | | | 9)NOTE: PLEASE PROVIDE INFORMATION ON | | | ENCLOUSURE/GUTTER FOR WHAT APPEARS TO | | | BE TAPS TO ELEVATOR MOTORS. PLEASE ALSO | | | PROVIDE AIC RATING AND MORE INFORMATION | | | FOR MAIN 1 OF 2 FOR ELEVATORS. | | | 110.9 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-03-09 |
Time |
11:29 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-03-09 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2004-03-09 00:00:00 | PASSED: | | | 1. THE APPLICANT APPLIED FOR SEPARATE | | | PERMIT FOR UNDERGROUND UTILITIES AND | | | SITE WORK. SEE # 04030446. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2004-03-08 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-03-08 |
Time |
10:15 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-03-08 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2004-03-08 00:00:00 | PASSED WITH PROVISOS: | | | 1. ALL COMMMENTS FROM PUBLIC UTILITIES | | | & ENGINEEERING MUST BE ADDRESSED AND | | | IMPLEMENTED, REVISIONS TO CIVIL PLANS | | | MUST BE SUBMITED TO BUILDING DEPARTMENT. | | | 2. PLEASE SUBMIT COPY OF SFWMD PERMIT | | | UPON RECEIVING. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2004-01-27 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-01-27 |
Time |
15:03 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-01-27 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2004-01-27 00:00:00 | FAILED: | | | 1. PLEASE SUBMIT CIVIL PLANS TO PUBLIC | | | UTILITIES AND ENGINEERING SERVICES FOR | | | THEIR REVIEW AND CONNECTION TO CITY | | | SERVICES, ATT; MANNY GONZALEZ 659-8040 | | | EXT. 2306. | | | 2. PLEASE SUBMIT STORM WATER CALCULATION | | | FOR OUR REVIEW AND APPROVAL, IT MUST | | | INCLUDE PERVIOUS AND IMPERVIOUS AREA FOR | | | THE TOTAL SITE. | | | 3. PLEASE INCLUDE POLLUTION/EROSION | | | PREVENTION IN CIVIL PLANS. | | | 4. PLESAE NOTE THAT ALL OFF STREET | | | PARKING MUST BE PAINTED WITH DOUBLE 4" | | | WIDE STRIPES, SHEET C-3. | | | 5. PLEASE SUBMIT A COPY OF SFWMD PERMIT. | | | 6. PLEASE NOTE THAT APPROACHES TO THE | | | SITE MUST BE CONSTRUCTED WITH 6" | | | CONCRETE FROM EDGE OF THE PAVEMENT TO | | | THE PROPERTY LINE, PER CITY REQUIREMENT. | | | 7. EXISTING SIDEWALK ALONG PROPERTY ALL | | | SIDE IF DAMAGED DURING THE CONSTRUCTION | | | MUST BE REPACED TO BETTER OR ORIGINAL | | | CONDITION. | | | 8. PROPOSED DRANAGE SYS. SHOULD BE | | | SHOWN ON SHEET C-1 INSTEAD OF C-2, | | | LINEAR FEET OF EACH RUN FOR PIPES AND | | | EXFILTRATION MUST BE SHOWN. | | | 9. PLEASE NOTE THAT NO CONSTRUCTION OR | | | LANDSCAPING IN EASMENT AREAS IS ALLOWED. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2005-01-04 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-01-04 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-01-04 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2005-01-04 00:00:00 | FIRE ALARM REVISION |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
F |
Date |
2004-08-16 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-08-16 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-08-16 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2004-08-16 00:00:00 | *************DENIED********************* | | | 1) AUTOMATIC SLIDING DOORS SHALL COMPLY | | | WITH NFPA 101 2000 EDITION CH 7.2.1.9 | | | AND CH 7.2.1.14 | | | | | | 2) LAUNDRY CHUTES SHALL COMPLY WITH NFPA | | | FIRE PREVENTION CODE 2000 EDITION CH 6-6 | | | AND NFPA 101 2000 EDITION CH 8-2 | | | | | | NATE MCCRAY, CAPTAIN | | | 835-2910 OR 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-03-30 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-03-30 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-03-30 |
Time |
12:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2004-03-12 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-03-12 |
Time |
07:15 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-03-12 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2004-03-12 00:00:00 | 1) THE FP-1 PAGE DOES NOT CORRESPOND | | | WITH C-2. | | | | | | 2) IS THE FIRE STANDPIPE/ SPRINKLER | | | ISOMETRIC DRAWING CORRECT. | | | | | | 3) STORAGE ROOM AND SUNDRIES STORAGE | | | NOT PROTECTED BY FIRE SPRINKLERS. | | | | | | 4) MEN'S AND WOMEN'S RESTROOM 163 | | | AND 164 NOT SPRINKLER PROTECTED. | | | | | | 5) ALL SMOKE DETECTORS SHALL BE | | | INSTALLED A MINIMUM OF THREE FEET | | | FROM AC DIFFUSERS. | | | | | | 6) PLEASE VERIFY TYPICAL ELECTRICAL | | | DRAWINGS ON PAGE E-7 AND VERIFY | | | THAT ENOUGH SMOKE DETECTORS ARE | | | PRESENT. | | | | | | 7) SOME EXIT SIGNS APPEAR TO BE | | | MISSING FROM THE FIRST FLOOR. | | | | | | 8) SMOKE DETECTOR MISSING FROM STORAGE | | | ROOM 113. | | | | | | 9) BUILDING ADDRESS REQUIRED. A MINIMUM | | | OF 6" NUMBERS REQUIRED. | | | | | | 10) LOCKING DEVICES ON EXIT DOORS TO | | | COMPLY WITH THE LIFE SAFETY CODE. | | | | | | 11) PLEASE DISPLAY ALL AVAILABLE | | | FIRE HYDRANTS LOCATED NEAR THE SITE. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-01-16 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-16 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-16 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2004-01-16 00:00:00 | 1) TEMPORARY STANDPIPE SYSTEM IS | | | REQUIRED WHEN THE BUILDING REACHES | | | THREE FLOORS OR 30 FEET IN HEIGHT | | | WHILE THE BUILDING IS UNDER | | | CONSTRUCTION. | | | | | | 2) CONSTRUCTION, DEMOLITION, AND | | | RENOVATION TO COMPLY WITH NFPA 241. | | | | | | 3) BUILDING ADDRESS REQUIRED. | | | | | | 4) A KNOX-BOX WILL BE REQUIRED. | | | | | | 5) TACTILE SIGNAGE REQUIRED AT ALL | | | STAIRWELLS. | | | | | | 6) EMERGENCY INSTRUCTIONS FOR GUESTS | | | SHALL BE POSTED. | | | | | | 7) ALL GUEST LAUNDRIES GREATER THAN | | | 100 SQUARE FEET SHALL BE PROTECTED | | | WITH ONE HOUR CONSTRUCTION AND | | | FIRE SPRINKLERS. MAINTENANCE SHOPS | | | AND TRASH COLLECTION ROOMS SHALL HAVE | | | ONE HOUR CONSTRUCTION AND SPRINKLERS. | | | | | | 8) STANDPIPE SYSTEM HOSE VALVES SHALL | | | BE PLACED WITHIN STAIRWELLS ON | | | EVERY FLOOR. | | | | | | 9) THE COVERED OVERHANG SHALL BE AT | | | LEAST 13'- 6" SO FIRE AND PARAMEDICAL | | | CAN PASS UNDERNEATH IT. | | | | | | 10) PLEASE INDICATE INTERIOR FINISH | | | FOR WALLS AND CEILINGS. | | | | | | 11) ANY AREAS OF REFUGE SHALL MEET | | | ALL OF THE REQUIREMENTS OF THE | | | FLORIDA FIRE PREVENTION CODE. | | | | | | 12) ALL GUESTROOMS FOR HEARING | | | IMPAIRED SHALL BE PROVIDED WITH | | | FIRE ALARM VISUAL APPLIANCES. | | | | | | 13) PLEASE PROVIDE PRESCRIPTIVE | | | DETAILS FOR ALL HANDRAILS AND | | | GUARDRAILS. | | | | | | 14) SOME BATHROOMS ARE SPRINKLER | | | PROTECTED IN GUESTROOMS AND SOME ARE | | | NOT. PLEASE EXPLAIN RATIONALE. | | | | | | 15) BATHROOMS 163 AND 164 ARE NOT | | | FIRE SPRINKLER PROTECTED. WHY? | | | | | | 16) THE FDC IS NOT SHOWN ON FIRST | | | FLOOR FIRE SPRINKLER PLAN. WHY? | | | | | | 17) NOTE # 11 ON PAGE FA-4 IS NOT | | | CORRECT. DUCT DETECTORS WHEN ACTIVATED | | | SHALL CAUSE A GENERAL ALARM. | | | | | | 18) FIRE ALARM CIRCUITS SHALL BE | | | CLASS A OR FULLY ADDRESSABLE. NOTE | | | # 8 ON PAGE FA-4 INDICATES CIRCUITS | | | WILL BE CLASS B. | | | | | | 19) THE FIRE ALARM SYSTEM SHALL BE | | | UL LISTED FOR CENTRAL STATION SERVICE. | | | | | | 20) ELEVATOR WARNING SIGNS REQUIRED | | | AT ELEVATORS. | | | | | | 21) SINGLE STATION SMOKE DETECTORS | | | ARE REQUIRED IN EVERY LIVING AREA | | | AND SLEEPING ROOM WITHIN GUEST SUITE. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2004-12-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-21 |
Time |
15:19 |
Rev Time |
0.60 |
| Received By |
kstevens |
Date |
2004-12-21 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2004-12-21 00:00:00 | DENIED | | | REFERENCE: FBC-2001 FUEL GAS | | | | | | LETTER FROM ANDREW J. YOUNGROSS P.E. | | | DATED DECEMBER 16, 2004 CHANGING THE | | | MAIN 3" SHUT OFF VALVE FOR THE GAS | | | SYSTEM IS NOT ACCEPTABLE. PER TABLE | | | 402(2) THE MAXIMUM BTU'S ALLOWED FOR 2" | | | PIPE AND VALVE IS 1,020,000 BTU'S AND | | | THE TOTAL BTU LOAD ON THE SYSTEM IS | | | 2,195,000 BTU'S. A 3" SOV IS REQUIRED. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
35 |
Status |
N |
Date |
2005-01-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-21 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-21 |
Time |
10:54 |
Sent To |
E |
|
| Notes |
| 2005-01-21 00:00:00 | TO "JL" DESK./REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
34 |
Status |
N |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-29 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-29 |
Time |
14:19 |
Sent To |
FIRE |
|
| Notes |
| 2004-12-29 00:00:00 | TO "FIRE" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
33 |
Status |
N |
Date |
2004-12-17 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-17 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-17 |
Time |
15:34 |
Sent To |
M |
|
| Notes |
| 2004-12-17 00:00:00 | SENT TO "M/AC" BOX. ONE SUBMMITAL TO "P" | | | BOX ALSO. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
32 |
Status |
N |
Date |
2004-12-01 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-01 |
Time |
18:44 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-01 |
Time |
18:44 |
Sent To |
E |
|
| Notes |
| 2004-12-01 00:00:00 | SENT TO "E" TO DP. DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
31 |
Status |
N |
Date |
2004-11-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-15 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-15 |
Time |
09:27 |
Sent To |
M |
|
| Notes |
| 2004-11-15 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
30 |
Status |
N |
Date |
2004-10-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-27 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-27 |
Time |
10:27 |
Sent To |
P |
|
| Notes |
| 2004-10-27 00:00:00 | TO KS BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
29 |
Status |
N |
Date |
2004-10-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-18 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-18 |
Time |
15:03 |
Sent To |
Z |
|
| Notes |
| 2004-10-18 00:00:00 | TO LANDSCAPE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
28 |
Status |
N |
Date |
2004-10-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-07 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-07 |
Time |
14:50 |
Sent To |
M |
|
| Notes |
| 2004-10-07 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
27 |
Status |
N |
Date |
2004-10-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-06 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-06 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2004-10-06 00:00:00 | TO COMM BD#25 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
26 |
Status |
N |
Date |
2004-10-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-05 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-05 |
Time |
15:14 |
Sent To |
B |
|
| Notes |
| 2004-10-05 00:00:00 | TO LM DESK/SUBMITTAL | | | SHOP DRAWS & TRUSS DRAWS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
25 |
Status |
N |
Date |
2004-09-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-22 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-22 |
Time |
11:11 |
Sent To |
P |
|
| Notes |
| 2004-09-22 00:00:00 | TO KS BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
24 |
Status |
N |
Date |
2004-08-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-30 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-30 |
Time |
10:29 |
Sent To |
P |
|
| Notes |
| 2004-08-30 00:00:00 | TO KS BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
23 |
Status |
N |
Date |
2004-08-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-30 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-30 |
Time |
10:28 |
Sent To |
E |
|
| Notes |
| 2004-08-30 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
22 |
Status |
N |
Date |
2004-08-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-30 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-30 |
Time |
09:27 |
Sent To |
M |
|
| Notes |
| 2004-08-30 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
N |
Date |
2004-08-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-18 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-18 |
Time |
16:48 |
Sent To |
P |
|
| Notes |
| 2004-08-18 00:00:00 | TO KS BOX/SUBMITTAL | | | DELETION OF WATER HAMMER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2004-08-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-18 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-18 |
Time |
16:47 |
Sent To |
E |
|
| Notes |
| 2004-08-18 00:00:00 | TO DP DESK/SUBMITTAL | | | USE OF ENT CONDUIT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2004-08-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-16 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-16 |
Time |
16:39 |
Sent To |
B |
|
| Notes |
| 2004-08-16 00:00:00 | TO SH DESK/SUBMITTAL | | | PLUMBER'S FIRESTOP SYSTEM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2004-08-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-16 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-16 |
Time |
09:10 |
Sent To |
B |
|
| Notes |
| 2004-08-16 00:00:00 | TO SH DESK/SUBMITTAL | | | DETAIL FOR HEAD JOINTS IN MASONARY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2004-08-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-08-10 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-08-10 |
Time |
08:36 |
Sent To |
B |
|
| Notes |
| 2004-08-10 00:00:00 | SUBMITTAL TO LM DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2004-08-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-10 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-10 |
Time |
07:49 |
Sent To |
B |
|
| Notes |
| 2004-08-10 00:00:00 | TO SH DESK/SUBMITTAL | | | REPAIR DETAIL -LOUVER PENETRATIONS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2004-08-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-10 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-10 |
Time |
07:48 |
Sent To |
E |
|
| Notes |
| 2004-08-10 00:00:00 | TO DP DESK/SUBMITTAL | | | USE OF M.C. CABLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2004-07-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-30 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-30 |
Time |
16:42 |
Sent To |
B |
|
| Notes |
| 2004-07-30 00:00:00 | TO SH DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2004-07-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-30 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-30 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2004-07-30 00:00:00 | TO COMM BD#60 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2004-07-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-30 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-30 |
Time |
16:32 |
Sent To |
B |
|
| Notes |
| 2004-07-30 00:00:00 | TO 3 LETTERSOF CLARIFICATION | | | 1 REVISED STRUCTURAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2004-07-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-30 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-30 |
Time |
16:32 |
Sent To |
B |
|
| Notes |
| 2004-07-30 00:00:00 | TO SH DESK/SUBMITTAL ROOF |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2004-06-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-11 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-11 |
Time |
09:05 |
Sent To |
B |
|
| Notes |
| 2004-06-11 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2004-06-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-08 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-08 |
Time |
13:24 |
Sent To |
B |
|
| Notes |
| 2004-06-08 00:00:00 | TO SH DESK/REVISED 12 STRUCTURAL SHEETS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-06-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-08 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-08 |
Time |
11:56 |
Sent To |
B |
|
| Notes |
| 2004-06-08 00:00:00 | TO SH DESK/SUBMITTAL/SECONDARY POUR |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-05-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-27 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-27 |
Time |
11:39 |
Sent To |
B |
|
| Notes |
| 2004-05-27 00:00:00 | TO LM DESK/SUBMITTAL/ENGD SHORING SHOP | | | DRAWS/SIGNED & SEALED |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-05-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-17 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-17 |
Time |
08:32 |
Sent To |
B |
|
| Notes |
| 2004-05-17 00:00:00 | TO LM DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-04-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-16 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-16 |
Time |
16:42 |
Sent To |
P |
|
| Notes |
| 2004-04-16 00:00:00 | TO KS BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-04-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-06 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-06 |
Time |
07:44 |
Sent To |
|
|
| Notes |
| 2004-04-06 00:00:00 | TO LM/ENG TO LOOK AT THIS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-03-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-25 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-25 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2004-03-25 00:00:00 | TO COMM BD#59 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-03-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-04 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-04 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2004-03-04 00:00:00 | TO COMM BD#59/ROLLS ON RACK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-01-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-16 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-15 |
Time |
16:55 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
10 |
Status |
N |
Date |
2004-12-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-12-21 |
Time |
15:13 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-12-21 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2004-12-21 00:00:00 | REVISION; AHU HANGING DETAIL/CHANGE IN | | | CONDENSATE TRAP. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
9 |
Status |
P |
Date |
2004-11-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-11-29 |
Time |
08:14 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2004-11-29 |
Time |
07:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
P |
Date |
2004-10-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-20 |
Time |
10:32 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-10-20 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2004-10-20 00:00:00 | REVISION #7/DUCT SIZE CHANGE FROM | | | LOUNGE AREA |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2004-10-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-15 |
Time |
09:59 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2004-10-15 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2004-10-15 00:00:00 | REVISION #5 DATED 10-5-04 & #6 DATED | | | 10-14-04. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
N |
Date |
2004-10-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-12 |
Time |
12:43 |
Rev Time |
1.10 |
| Received By |
pkrauss |
Date |
2004-10-12 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2004-10-12 00:00:00 | PROVISO: | | | ISOMETRIC DIAGRAM-WATER HEATER FLUE | | | SYSTEM ON PLAN SHEET P-14, VENTING OF | | | GAS APPLIANCES SHOULD BE REFERENCED | | | UNDER THE MECHANICAL PLANS.WHEN | | | APPLIANCES ARE COMBINED AND A COMMON | | | VENT IS USED, THE VENT CAPACITY SHALL | | | COMPLY WITH 2001 FBC, FUEL GAS 502.3.20. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2004-10-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-08 |
Time |
07:48 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-10-08 |
Time |
07:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-09-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-09-16 |
Time |
06:58 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2004-09-16 |
Time |
06:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-08-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-30 |
Time |
09:28 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2004-08-16 |
Time |
13:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-03-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-17 |
Time |
16:06 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2004-03-17 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2004-03-17 00:00:00 | PROVISO: | | | 1.AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 FBC(M) | | | 307.2.3. | | | | | | 2.4" CLEARANCE AROUND THE AHU IS | | | REQUIRED PER 2001 FBC(M) 603.1.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-29 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2004-01-29 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2004-01-29 00:00:00 | DENIED: | | | PLEASE NOTE A-4 INDICATES THE FOLLOWING | | | WALLS/PARTITIONS AS #7 (1 HR): | | | ROOM #160,161,162,154,& 153, PLEASE NOTE | | | DUCTS ARE NOT REQUIRED TO HAVE FIRE | | | DAMPERS SHOULD THEY COMPLY WITH 2001 | | | FBC(M) 607.1.3 #3 1 THRU 4. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
11 |
Status |
P |
Date |
2004-11-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-03 |
Time |
13:33 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-11-03 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2004-11-03 00:00:00 | REVISION OK - GAS PIPE SIZING AND PIPE | | | ROUTING. - STORM PIPE ROUTING - ADD | | | CONDENSATE LINE UP TO ROOF |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
10 |
Status |
P |
Date |
2004-10-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-15 |
Time |
17:44 |
Rev Time |
3.00 |
| Received By |
kstevens |
Date |
2004-10-15 |
Time |
17:44 |
Sent To |
|
|
| Notes |
| 2004-10-15 00:00:00 | REVISIONS OK FOR SHEETS P-10, P-12, P-14 | | | & P-16 - DENIED P-9 | | | | | | REVISION DENIED | | | | | | SHT P-9 GAS RISER DIAGRAM DENIED. 2" RE- | | | QUIRED UP TO FIRST DRYER AND 1-1/2" RE- | | | QUIRED UP TO SECOND DRYER. - NFPA NOT | | | ADOPTED FOR GAS SIZING, AND PIPING SHALL | | | BE SIZED BY FBC-2001 FUEL GAS CODE TABLE | | | 402(2). - RESIZE PIPING PER APPROVED | | | CODE TABLE AND RESUBMIT GAS RISER REVIS- | | | ION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
9 |
Status |
F |
Date |
2004-10-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-12 |
Time |
10:08 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2004-10-12 |
Time |
10:08 |
Sent To |
M |
|
| Notes |
| 2004-10-12 00:00:00 | REVISION FOR SHEETS P-13 & P-15 OK | | | REVISION FOR SHEET P-14 DENIED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
F |
Date |
2004-09-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-09-21 |
Time |
13:50 |
Rev Time |
3.50 |
| Received By |
kstevens |
Date |
2004-09-20 |
Time |
18:49 |
Sent To |
|
|
| Notes |
| 2004-09-21 00:00:00 | REVISISON DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | | | | A) SHT P-9 FROM PREVIOUS REVIEW: | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE.- MANY LENGTHS ARE NOT | | | SHOWN FOR CUT SECTIONS OF PIPES. SEE | | | RED LINE MARKS FOR SECTIONS WITH NO | | | LENGTHS SHOWN, | | | 2) SHT P-10 REVISION #4 NOT FOUND. | | | PLEASE CLAIRFY. SECTION 104.2.1 | | | 3) SHT P10 NEW EMERGENCY OVERFLOW DRAINS | | | SHOWN ON REVISIONS ARE NOT APPROVED. | | | ROOF DRAINS L1, L2, L5, L6, & L7 REQUIRE | | | 50.24 SQ IN, TWO 6" DRAINS PROVIDE 56.54 | | | SQ IN. BUT FOUR 3" DRAINS ONLY PROVIDE | | | 28.26 SQ IN. - EMERGENCY OVERFLOW DRAINS | | | FOR L3, & L4 REQUIRE 28.26 SQ IN, BUT | | | TWO 3" DRAINS ONLY PROVIDE 14.13 SQ IN. | | | SECTION 1107 | | | 4) FROM PREVIOUS REVIEW: THE CLEANOUTS | | | REQUIRED IN SECTION 708.3.1 ARE NOT TO | | | BE DELETED. NO EXCEPTION TO THIS SECTION | | | IS NOTED IN THE CODE. | | | 5) VACUUM RELIEF VALVES REQUIRED BY SEC- | | | TION 504.2 ARE NOT SHOWN IN THE PROPER | | | LOCATION. THESE VALVES SHALL BE LOCATED | | | ON THE SUPPLY SIDE OF THE HEATER AND BE | | | ABOVE THE TOP OF THE HEATERS. WATER | | | HEATERS ONE AND TWO SHOW THEM INSTALLED | | | ON THE HOT WATER SIDE. WATER HEATER | | | THREE AND THE STORAGE TANK HAVE NO VAC- | | | UUM RELIEF VALVES SHOWN. WILL WATER | | | HEATERS ONE AND TWO BE INSTALLED STACKED | | | AS SHOWN? WATER HEATERS SHOULD BE INST- | | | ALLED SO THAT THEY ARE PIPED IN PARALLEL | | | AND THE SUPPLY AND HOT WATER TIE IN THE | | | CENTER OF THE HEATERS SO THEY HEAT AND | | | ARE USED SIMULTAINIOUSLY. SECTION 104.2. | | | 1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
F |
Date |
2004-08-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-30 |
Time |
10:29 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-08-25 |
Time |
17:59 |
Sent To |
|
|
| Notes |
| 2004-08-25 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | FBC-2001 PLUMBING | | | | | | - SUBMITTAL LETTER FOR REVISION OF THE | | | WATER RISER DIAGRAM IS NOT APPROVED. THE | | | WATER RISER DIAGRAM SHALL BE REVISED TO | | | SHOW CHANGES IN THE FIELD FOR PUBLIC | | | RECORD. PLEASE SUBMIT CHANGES IN THE | | | FORM OF A REVISED WATER DIAGRAM SHOWING | | | ALL WATER HAMMER ARRESTORS REQUIRED BY | | | SECTION 604.9 - SECTION 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2004-08-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-18 |
Time |
16:48 |
Rev Time |
3.75 |
| Received By |
kstevens |
Date |
2004-08-11 |
Time |
18:56 |
Sent To |
|
|
| Notes |
| 2004-08-12 00:00:00 | REVISION DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. NEW RISER DIAGRAM DOES | | | NOT SHOW LENGTH OF PIPING TO POOL HEATER | | | SHEET P-9. | | | 2. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2001 FUEL GAS CODE SECS. 401.8 | | | THRU 402.5.2 AND TABLES 402(1) THRU | | | 402(34). SHEET P-9CHANGES IN PIPE SIZE | | | MAY BE REQUIRED WITH THE ADDITION BTU'S | | | FROM POOL HEATER. | | | 3. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 - SHEET | | | P-9 MANUF. SHEETS REQUIRED FOR POOL | | | HEATER VERIFYING BTU'S AND LISTING. | | | 4) SHT P-10 TWO 3" OVERFLOW DRAINS ARE | | | NOT APPROVED. - UPON REVIEW OF PLANS | | | THE MAXIMUM SQUARE FOOTAGE ALLOWED ON | | | HORIZONTAL SECONDARY 6" DRAINS IS 2,378. | | | ANY AREAS WITH MORE SQUARE FOOTAGE SHALL | | | BE REQUIRED TO HAVE AN 8" HORIZONTAL | | | DRAIN. 6" IS REQUIRED FOR THE TWO SMALL- | | | ER AREAS OF THE ROOF. TWO PIPES 1/2 THE | | | AREA DO NOT EQUAL THE SAME AREA AS THE | | | 1 PIPE TWICE THE SIZE. TABLES 1106.2 & | | | 1106.3 @ 4.5 INCHES RAIN PER HR. | | | 5) SHT P-12 CLEANOUTS ARE REQUIRED A | | | MINIMUM OF 100' IN THE BUILDING DRAIN. | | | REMOVING THE CLEANOUT IS NOT APPROVED. | | | SECTION 708.3.1 | | | 6) SHT P-14 SHOW CORRECT LOCATIONS OF | | | THE VACUUM RELIEF VALVES REQUIRED FOR | | | THE BOTTOM FED WATER HEATERS AS REQUIRED | | | IN SECTION 504.2. SEE CORRECTIONS ON | | | STAMPED SET OF PLANS AND REVISE THESE | | | CORRECTIONS AS THIS REVISION IS AN AS- | | | BUILT REVISION. SECTION 104.2.1 | | | 7) ALL CHANGES TO STORM PIPING SHALL BE | | | REFLECTED ON THE STORM RISER DIAGRAMS. | | | SECTION 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2004-04-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-26 |
Time |
16:32 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-04-26 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2004-04-26 00:00:00 | REVISION OK - CHANGED BLDG DRAIN FROM | | | 1 8" LINE TO 2 6" LINES EXITING BLDG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-03-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-16 |
Time |
16:42 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-03-30 |
Time |
11:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2004-03-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-26 |
Time |
17:45 |
Rev Time |
2.50 |
| Received By |
kstevens |
Date |
2004-03-26 |
Time |
17:44 |
Sent To |
|
|
| Notes |
| 2004-03-26 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT P-16 LOWER ROOF ON N-WEST SIDE | | | SHOWS 6" STORM DRAIN, THEN AFTER SECOND | | | ROOF DRAIN SHOWS 4" STORM DRAIN. MINIMUM | | | 8" STORM DRAIN REQUIRED AFTER SECOND | | | ROOF DRAIN. | | | 2) SHT P-9 STORM DRAIN LINE FROM (L5) | | | ADDS (L8) OUTSIDE BLDG. THIS DRAIN WAS | | | NOT FOUND. PLEASE CLAIRFY AND INDICATE | | | WHERE L8 CAN BE LOCATED. | | | 3) MEASUREMENTS STILL MISSING FOR SOME | | | ACCESSIBLE FIXTURES. NOT HEIGHT SHOWN | | | FOR URINAL 11-4.18.2, HEIGHT & CLEARANC- | | | ES FOR LAVS 11-4.19.2, EXPOSED PIPES AND | | | SURFACES 11-4.19.4, SPOUT HEIGHT FOR THE | | | DRINKING FOUNTAIN 11-4.15.2 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-03-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-15 |
Time |
18:29 |
Rev Time |
7.00 |
| Received By |
kstevens |
Date |
2004-03-15 |
Time |
18:29 |
Sent To |
|
|
| Notes |
| 2004-03-15 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | A) FOLLOWING COMMENTS WERE NOT ADDRESSED | | | OR COMMENT RESPONSE WAS NOT FOUND OR NOT | | | ADDRESSED PROPERLY. THE COMMENT NUMBER | | | FROM FIRST REVIEW WILL BE SHOWN TO AVOID | | | CONFUSION. | | | 2) SHOW COMPLIANCE WITH SECTION 11-9.1.3 | | | ACCOMMODATIONS FOR PERSONS WITH HEARING | | | IMPAIRMENT. - RESPONSE NOTED - FOUND 4 | | | UNITS PLUS ONE ACCESSIBLE UNIT WITH THIS | | | ACCOMODATION. ONE ADDITIONAL UNIT WILL | | | BE REQUIRED SEPARATE FROM ACCESSIBLE | | | UNITS PER SECTION11-9.1.3 | | | 4) SHT A-5 SUBMIT CALCULATIONS FOR LOWER | | | ROOFS PER SECTION 1106 AND ALL SUBSECT- | | | IONS. SHOW 1/2 AREA OF VERTICAL WALL | | | ADDED TO SQUARE FOOTAGE OF ROOF IN CAL- | | | CULATIONS. - NO CALCULATIONS WERE FOUND | | | IN MECHANICAL PLANS. INDICATE SPECIFIC | | | SHEET RESPONSE IS LOCATED. - PER CONVER- | | | SATION WITH STEVE SHEET P-16 WILL BE | | | SUBMITTED WITH THIS INFO. | | | 5) SUBMIT CALCULATIONS FOR PRIMARY AND | | | SECONDARY ROOF DRAINS PER SECTIONS 1106 | | | AND 1107 AND ALL SUBSECTIONS. - RESPONSE | | | TO SCUPPER COMMENT SEEN - BLDG OFFICIAL | | | THINKS THAT IT WILL BE A LEAK PROBLEM. | | | HE SAYS THAT A TROUGH MAY BE A BETTER | | | SOLUTION. SUBMIT A DETAIL WITH MEASURE- | | | MENTS SHOWING COVERAGE OF 6" PIPE ECT IF | | | THIS IS THE SECONDARY DRAIN STILL WANTED | | | 6) SHTS A-27 & A-28 SHOW MEASUREMENTS | | | FOR FIXTURES PER SEC'S 11-4.15, 11-4.16, | | | 11-4.18, 11-4.19, & 11-4.23 AND ALL SUB- | | | SECTIONS. SHOW CLEAR FLOOR SPACE FOR ALL | | | ACCESSIBLLE FIXTURES INCLUDING DRINKING | | | FOUNTAINS, URNALS ECT. - RESPONSE NOTED | | | SOME CLEAR FLOOR SPACES NOT SHOWN. ROOM | | | 117 EMPLOYEE LOUNGE SHOW CLEAR FLOOR | | | FOR SINK. SHT A-12 KING DELUX ACCESSIBLE | | | SHOW 5' TURNING AREA. SHT A-11 SHOW | | | CLEAR FLOOR SPACE AT DRINKING FOUNTAINS. | | | SHT A-15 SHOW CLEAR FLOOR SPACE FOR THE | | | URINAL ROOM 114. | | | 10) SHT P-9 SEPARATE GAS PERMIT REQUIRED | | | FOLLOWING INFORMATION REQUIRED FOR THE | | | GAS PERMIT. | | | B) SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED.- NO MATERIAL FOR PIPE LOCATED | | | C) SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR PER FBC-2001 FUEL GAS CODE SECTION | | | 304. - RESPONSE NOTED. SHT M-1 CALCULAT- | | | IONS INDICATE 2 DRYERS, BUT SHT P-9 GAS | | | RISER SHOWS 3 DRYERS @ 165K BTU'S EACH | | | PLEASE CLAIRFY. - ALSO 124 SQUARE INCHES | | | IS REQUIRED AT DRYER IF VERTICAL DUCT | | | BUT IF HORIZONTAL DUCT 247.5 SQ IN REQD. | | | 10" DUCT VERT WILL SUPPLY 78.5 SQ. IN. | | | PLEASE SUBMIT DETAIL FOR DUCT. INDICATE | | | IF VERTICAL OR HORIZONTAL, AND IF AIR | | | IS OUTSIDE OR INSIDE AIR SUPPLYING THE | | | COMBUSTION AIR. - SHOW COMBUSTION AIR | | | CALCULATIONS FOR THE 80K BTU'S IN THE | | | GUEST LAUNDRY ROOM. | | | E) SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2- RE- | | | SPONSE NOTED, BUT NO MANUF. SHEETS WERE | | | FOUND IN MECH. SHEETS. | | | 12) SHT P-10 ROOF DRAIN AND SQUARE FOOT- | | | AGE NOT SHOWN FOR ROOF BELOW AT ENTRANCE | | | 16) LOCATION OF WATER HAMMER ARRESTORS | | | SHALL BE NEAR THE FIXTURES IN AN | | | "EFFECTIVE RANGE" NOT IN CEILING AS | | | SHOWN. PDI-WH 201 AND MANUF. INSTALL. | | | INSTRUCTIONS. | | | 17) SHT P-14 VACUUM RELIEF VALVES REQUI- | | | RED FOR BOTTOM FED WATER HEATERS. SEC | | | 504.2 - RESPONSE NOTED, BUT THIS HAS NOT | | | BEEN ADDRESSED. | | | 18) WATER HAMMER ARRESTORS SHALL BE | | | LOCATED NEAR FIXTURE NOT IN CEILING. | | | PDI-WH 201 AND MANUF. INSTALL. INSTRUCT. | | | 19) SEE COMMENTS 16 & 18. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-01-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-30 |
Time |
17:37 |
Rev Time |
6.00 |
| Received By |
kstevens |
Date |
2004-01-30 |
Time |
17:37 |
Sent To |
|
|
| Notes |
| 2004-01-30 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHOW COMPLIANCE WITH SECTION 11-9.1.4 | | | CLASSES OF SLEEPING ACCOMMODATION. THE | | | "KING SUITE DELUXE UNITS" HAVE NOT BEEN | | | SHOWN TO HAVE ANY ACCESSIBLE UNITS. | | | 2) SHOW COMPLIANCE WITH SECTION 11-9.1.3 | | | ACCOMMODATIONS FOR PERSONS WITH HEARING | | | IMPAIRMENT. | | | 3) SHOW COMPLIANCE WITH SECTION 11-9.2.3 | | | ONE UNIT REQUIRED UNDER THIS SECTION. | | | 4) SHT A-5 SUBMIT CALCULATIONS FOR LOWER | | | ROOF PER SEC 1106 AND ALL SUBSECTIONS. | | | SHOW 1/2 AREA OF VERTICAL WALL ADDED TO | | | SQUARE FOOTAGE OF ROOF IN CALCULATIONS. | | | 5) SUBMIT CALCULATIONS FOR PRIMARY AND | | | SECONDARY ROOF DRAINS PER SECTIONS 1106 | | | AND 1107 AND ALL SUBSECTIONS. - SCUPPERS | | | ARE 36 FEET OR MORE FROM SOME OF THE | | | ROOF DRAINS. AT 1/4" PER FOOT SLOPE AND | | | THE SCUPPERS 2" TO 4" TO FLOW LINE, THE | | | PONDING WILL BE APPROXIMATELY 13" DEEP | | | NEAR THE DRAIN. THIS WILL PLACE WEIGHT | | | OF 4.5 TO 6 INCHES OF WATER ON ROOF BE- | | | FOR THE RAIN WATER WILL START TO DRAIN | | | THRU THE SCUPPERS. SUBMIT CALCULATIONS | | | FOR ROOF TO SHOW IT WILL SUPPORT THIS | | | WEIGHT. | | | 6) SHTS A-27 & A-28 SHOW MEASUREMENTS | | | FOR FIXTURES PER SEC'S 11-4.15, 11-4.16, | | | 11-4.18, 11-4.19, AND 11-4.23 AND ALL | | | SUBSECTIONS. SHOW CLEAR FLOOR SPACE FOR | | | ALL ACCESSIBLE FIXTURES INCLUDING DRINK- | | | ING FOUNTAINS, URNALS ECT. | | | 7) SHTS A-15.1 & A-28 PRIVATE BATHROOM | | | SHALL BE ADAPTABLE. SHOW DETAIL FOR | | | SHOWER BACKING, CURB, VALVE HEIGHT, AND | | | OPENING FOR WATER CLOSET AND CLEAR FLOOR | | | SPACE AND TURNING AREA ECT. | | | 8) SHT A-34 SEPARATE PLANS & PERMIT REQ- | | | UIRED FOR POOL. PLANS TO BE SUBMITTED TO | | | PALM BEACH COUNTY HEALTH DEPT. FOR APP- | | | ROVAL PRIOR TO SUBMITTING TO CITY WPB | | | FOR REVIEW. | | | 9) SHT P-1 PLUMBING NOTES #13, AIR | | | CHAMBERS ARE NOT APPROVED. DELETE FROM | | | NOTES. SECTION 604.9 | | | 10) SHT P-9 SEPARATE GAS PERMIT REQUIRED | | | FOLLOWING INFORMATION REQUIRED FOR THE | | | PERMIT: | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED AND ALL PIPE SIZES. (RECOMMEND | | | THAT A 2 POUND SYSTEM BE USED AS THIS | | | WILL REDUCE THE PIPE SIZE) | | | C. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2001 FUEL | | | GAS CODE SECTION 304. | | | D. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2001 FUEL GAS CODE | | | SECS. 502 THRU 506. | | | E. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | 11) SEPARATE IRRIGATION PLANS AND PERMIT | | | ARE REQUIRED. | | | 12) SHT P-10 ROOF DRAIN AND SQUARE FOOT- | | | AGE NOT SHOWN FOR ROOF BELOW AT ENTRANCE | | | 13) SHT P-11 IDENTIFY FIXTURES ON SANT. | | | RISER S/15. | | | 14) SHT P-11 FLOOR DRAINS NOT APPROVED | | | FOR INDIRECT WASTE. SECTIONS 802.3 AND | | | 802.3.2 | | | 15) SHT P-11 FIXTURE UNITS ARE NOT CORR- | | | ECT FOR SANT. RISERS S/5 THRU S-14. THE | | | WATER CLOSETS ARE 4DFU NOT 3DFU. ADJUST | | | FIXTURE UNITS ON RISERS, AND FIXTURE | | | UNITS ACCUMULATED IN BLDG DRAIN ON SHT | | | P-12. 6" PIPE REQUIRED @ 186 FU WHERE IT | | | SHOWS 4" @ 159 FU. | | | 16) SHT P-13 DOMESTIC WATER RISER, AIR | | | CHAMBERS ARE NOT APPROVED. DELETE FROM | | | RISER DIAGRAM. SECTION 604.9 - WATER | | | HAMMER ARRESTORS ARE REQUIRED AT ALL | | | QUICK CLOSING VALVES, (WASH MACHINES, | | | ICE MAKERS, AND DISH WASHERS), & LOCATED | | | NEAR THE FIXTURE IN AN "EFFECTIVE RANGE" | | | NOT IN THE CEILING. PDI-WH 201 AND MANUF | | | INSTALLATION INSTRUCTIONS. | | | 17) SHT P-14 VACUUM RELIEF VALVES REQUI- | | | RED FOR BOTTOM FED WATER HEATERS. SECT- | | | ION 504.2 | | | 18) SHT P-14 ISOMETRIC WATER DIAGRAM, | | | AIR CHAMBERS AT POOL SHOWER NOT APPROVED | | | DELETE. 604.9 | | | 19) SHT P-15 DOMESTIC WATER ISOMETRIC | | | DIAGRAMS, AIR CHAMBERS ARE NOT APPROVED. | | | DELETE FROM RISERS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2004-11-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-11-09 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-11-09 |
Time |
17:01 |
Sent To |
|
|
| Notes |
| 2004-11-09 00:00:00 | PROVISO - | | | | | | 1) INSTALL 6 (2 GROUPS OF 3) SABEL PALMS | | | ALONG AUSTRALIAN AVENUE AS REQUIRED BY | | | CENTREPARK WEST UNIFIED STREETSCAPE PLAN | | | (1999). | | | | | | 2) INSTALL 2 ROYAL PALMS AT PEDESTRIAN | | | CONNECTION AS REQUIRED BY CENTREPARK | | | WEST UNIFIED STREETSCAPE PLAN (1999). |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2004-10-20 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2004-10-20 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-11-09 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2004-10-20 00:00:00 | 1. NEED MINOR AMENDMENT TO THE PD | | | 2. PALMS NEED TO BE PROVIDED ON | | | AUSTRIALIAN AVE AS REQUIRED BY | | | AUSTRALIAN AVE STREETSCAPE PLAN. | | | CALL JOHN ROACH AT 822-1435 | | | CALLED CONT 10-20-04 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2004-03-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-11 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2004-03-30 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2004-03-30 00:00:00 | 3/30/2004 - REVISED SITE PLAN SUBMITTED | | | FOLLOWING APPROVAL ON 3/24/2004. | | | REVISED PLAN OK.JOHN ROACH, PLANNER - | | | 659.8031 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-03-30 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2004-03-23 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2004-03-23 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2004-03-23 00:00:00 | 3/23/2004 - RECORDED UNITY OF TITLE AND | | | EASEMENT TERMINATION AGREEMENT SUBMITTED | | | AND ADDED TO PERMIT PACKAGE.PLANS | | | PASSED SUBJECT TO APPROVAL OF REVISIONS | | | OF LANDSCAPE PLAN TO ACCOMMODATE | | | ADDITION OF POOL EQUIPMENT.JOHN | | | ROACH, PLANNER - 659.8031 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-01-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-15 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-01-16 |
Time |
10:28 |
Sent To |
I |
|
| Notes |
| 2004-01-16 00:00:00 | DENIED, WAITING ON SIGNED TERMINATION | | | AGREEMENT & THE UNITY OF TITLE NEEDS TO | | | BE RECORDED FOR LOTS 1,2 AND A PORTION | | | OF 7 PER JOHN ROACH PLANNER 659-8031 MM |
|
|