Plan Review Details - Permit 04010749
Plan Review Stops For Permit 04010749
Review Stop B BUILDING (STRUCTURAL)
Rev No 10 Status P Date 2004-10-14 Cont ID  
Sent By lmartine Date 2004-10-14 Time 09:06 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
2004-10-14 00:00:00APPROVE TRUSS ENGINEERING

Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status P Date 2004-08-17 Cont ID  
Sent By csiegber Date 2004-10-05 Time 15:14 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2004-06-14 Cont ID  
Sent By csiegber Date 2004-08-16 Time 16:39 Rev Time 0.50
Received By shill Date 2004-06-14 Time 07:58 Sent To  
Notes
2004-06-14 00:00:00RFI 19, 38, LETTER RE:MISC FIELD ITEMS
 PREPARED BY JOHNSON STRUCTURAL, 6/9/4

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2004-06-10 Cont ID  
Sent By csiegber Date 2004-06-11 Time 09:06 Rev Time 1.50
Received By shill Date 2004-06-10 Time 12:39 Sent To  
Notes
2004-06-10 00:00:00STRUCTURAL REVISION - S2.0, 2.1, 2.3,
 3.3, 4.0, 4.1 DATED 6/3/04 REV #4

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2004-06-09 Cont ID  
Sent By shill Date 2004-06-09 Time 11:24 Rev Time 0.50
Received By shill Date 2004-06-09 Time 11:24 Sent To  
Notes
2004-06-09 00:00:00LETTER FROM JOHNSON STRUCTURAL GROUP
 APPROVAL TO POUR PORTE COCHERE AS
 SECONDARY POUR, DATED 6/7/04
  
 SHORING/RESHORE PLAN PREPARED BY HECTOR
 VERGARA, PE DATED 5/19/04

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2004-06-04 Cont ID  
Sent By csiegber Date 2004-06-08 Time 13:24 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
2004-06-04 00:00:00SHORING SHOP DRAWINGS

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-05-20 Cont ID  
Sent By csiegber Date 2004-05-27 Time 11:39 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
2004-05-20 00:00:00REVISIONS APPROVED

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-03-31 Cont ID  
Sent By csiegber Date 2004-05-17 Time 08:33 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-03-23 Cont ID  
Sent By lmartine Date 2004-03-23 Time 18:04 Rev Time 5.00
Received By lmartine Date   Time   Sent To  
Notes
2004-03-23 00:00:00 
 BUILDING REVIEW COMMENTS
 ------------------------
  
  
 1]
 PRODUCT APPROVAL REPORTS ARE NOT
 COMPLETE.
  
 2]
 SEE FBC 105.13.4.4, STATEMENT IN THIS
 SECTION SHALL BE ON THE APPROVED
 DOCUMENTS SIGNED AND SEALED. THRESHOLD
 INSPECTOR SHALL BE APPROVED BY CITY
 INSPECTION STAFF, PLEASE CONTACT HAROLD
 PISKURA AT 805-6665.
  
 3]
 SHEETS A-29 AND A-26 CALL FOR CROWN
 MOLDINGS ON EXTERIOR?
  
 4]
 ADDITIONAL FEES DUE;
 COUNTY IMPACT FEES.
 CITY PERMIT FEES.
  
  
  
  
 REVIEWED BY:
 LUIS MARTINEZ
 561-805-6710

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-02-26 Cont ID  
Sent By lmartine Date 2004-02-26 Time 17:15 Rev Time 12.00
Received By lmartine Date   Time   Sent To  
Notes
2004-02-26 00:00:00 
 BUILDING REVIEW COMMENTS
 ------------------------
  
  
 1]
 SUBMIT 3 SIGNED AND SEALED SURVEYS.
 A SIGNED AND SEALED ELEVATION
 CERTIFICATE SHALL BE REQUIRED. FLOOD
 ZONE A-9.
  
 2]
 PROVIDE SIGNED AND SEALED SOILS
 INVESTAGATION REPORT FOR REVIEW.
  
 3]
 SUBMIT DOOR HARDWARE INFORMATION.
  
 4]
 PROVIDE INTERIOR DESIGNERS PLAN FOR
 DIMENSIONS AND LAYOUT FOR THE FIRST
 FLOOR COMMON AREAS.
  
 5]
 SUBMIT STATE OF FLORIDA PRODUCT
 APPROVAL REPORTS FOR ALL EXTERIOR
 GLAZING, DOORS AND ROOF COVERINGS.
  
 6]
 PROVIDE A SIGNED AND SEALED THRESHOLD
 BUILDING PLAN FOR APPROVAL.
  
 7]
 SUBMIT SPRINKLER LAYOUT SIGNED AND
 SEALED BY A FLORIDA REGISTERED FIRE
 SPRINKLER DESIGN PROFESSIONAL AS PER
 SECT. 553.79 FL. BUILDING CODES AND
 STANDARDS.
  
 8]
 EXTERIOR ARCHITECTURAL TRIM FOAM
 MOLDINGS ARE NOT PERMITTED, SEE SECTION
 1404.1 2001 F.B.C.
  
 9]
 PUBLIC SWIMMING POOL WILL BE REVIEWED
 UNDER SEPERATE PERMIT.
  
 10]
 SECTIONS CALLED OUT ON SHEET A-23
 REFERENCEING SHEET A-24 AND A-30 ARE
 INCORRECT.
  
 11]
 THE ASSIGNED ADDRESS TO YOUR PROJECT IS
 1601 WORTHINGTON RD.
  
 12]
 ADDITIONAL FEES DUE;
 COUNTY IMPACT FEES
 CITY PERMIT FEES
  
  
  
  
  
 REVIEWED BY:
 LUIS MARTINEZ
 561-805-6710

Review Stop E ELECTRICAL
Rev No 8 Status P Date 2005-01-24 Cont ID  
Sent By jleahy Date 2005-01-24 Time 09:11 Rev Time 2.00
Received By jleahy Date 2005-01-24 Time 09:11 Sent To  
Notes
2005-01-24 00:00:00PUT OUT FRONT FOR PICKUP JL1/24/05

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2004-12-03 Cont ID  
Sent By mjacobs Date 2005-01-20 Time 13:46 Rev Time 0.50
Received By dpalmer Date 2004-12-03 Time 09:01 Sent To  
Notes
2004-12-03 00:00:00NOTES,
 PLEASE SEE REVISED AIC RATINGS.

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2004-09-16 Cont ID  
Sent By dpalmer Date 2004-09-16 Time 07:20 Rev Time 0.25
Received By dpalmer Date 2004-09-16 Time 07:06 Sent To  
Notes
2004-09-16 00:00:00LTR FOR THE PERMITTED USE OF ENT.
 PER NEC.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2004-09-16 Cont ID  
Sent By dpalmer Date 2004-09-16 Time 07:02 Rev Time 1.01
Received By dpalmer Date 2004-09-15 Time 07:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-08-18 Cont ID  
Sent By csiegber Date 2004-08-30 Time 10:28 Rev Time 0.25
Received By dpalmer Date 2004-08-18 Time 08:38 Sent To  
Notes
2004-08-18 00:00:00LETTER FOR MC CABLE FOR BRANCH CIRCUITS.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2004-08-13 Cont ID  
Sent By dpalmer Date 2004-08-13 Time 10:02 Rev Time 2.00
Received By dpalmer Date 2004-08-12 Time 14:30 Sent To  
Notes
2004-08-13 00:00:00************ UNSAT ***************
  
 1)NOTE: PLEASE SEE THERE ARE SOME SHEETS
 WHERE A REVISION IS NOTED ON TITLE
 BLOCK, BUT WAS NOT ABLE TO LOCATE A
 REV#/CLOUD/TRIANGLE ON PLAN.
 SHEETS: E-3,E-4,E-11
  
 2)NOTE: PLEASE SEE NEW PANELS NOW WHICH
 HAVE BEEN ADDED TO RISER. 2R2,3R3,4R4,
 THESE PANELS WERE ADDED ON PREVIOUS
 REVISED PLANS HOWEVER THERE IS NO
 INDICATION ON PANELS 2R2,3R2,4R2 IF THEY
 ALSO CONATIN FEED-THRU LUGS OR IF THESE
 PANELS CONTAIN OCP FOR SUB-FEEDS?
 **PLEASE ALSO SEE THESEPANELS ARE NOT
 INCLUDED ON FLR PLANS FOR ELECTRICAL
 ROOMS.
  
 3)NOTE: PLEASE SEE NOTE # 7 FROM FIRST
 REVIEW. PANEL LR IS STILL BEING SHOWN
 AS BEING A 100A RATED PANEL WITH A 125A
 FEED FROM MDP. PLEASE SEE MDP SCHEDULE
 WHICH INDICATES 125A BRKR.
 THIS WAS NOT CORRECTED FROM FIRST REVIEW
 408.13
  
 4)NOTE:PLEASE ADD NOTE WIND LOADS TO
 MEET 140MPH ON SITE PLAN ELECTRICAL
 LT POLES.
  
 **POOL UNDER SEPARATE PERMIT, INCLUDING
 ELECTRICAL.
 AN ELECTRICAL WILL BE REQUIRED AT THAT
 TIME WITH A SEPARATE POOL EQUIPMENT
 WIRING DIAGRAM.
 **THIS IS ONLY A NOTE***
  
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AN
 ONLY INSERT NEW REVISED SHEEST INTO
 COMPLETED SETS FOR REVIEW AND STAMPING.
  
 PLEASE SEE POSSIBLE COMMENTS FROM OTHER
 REVIEWERS WHICH MAY HAVE AN AFFECT ON
 ELECTRICAL PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-03-18 Cont ID  
Sent By csiegber Date 2004-08-10 Time 07:48 Rev Time 2.00
Received By btrobaug Date 2004-03-18 Time 14:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-01-29 Cont ID  
Sent By dpalmer Date 2004-01-29 Time 07:39 Rev Time 3.00
Received By dpalmer Date 2004-01-28 Time 13:33 Sent To  
Notes
2004-01-29 00:00:00************** UNSAT **************
  
 1)NOTE: PLEASE SEE FIRE REVIEW NOTESAND
 NOTES FROM OTHER REVIEWERS THAT MAY HAVE
 AN AFFECT ON ELECTRICAL PLANS.
  
 2)NOTE: PLEASE SEE PANEL EQA IS SHOWN
 ON RISER BUT COULD NOT BE LOCATED ON
 PLANS.
  
 3)NOTE: PLEASE ALSO SEE PANELS SHOWN
 ON RISER FOR 2ND, 3RD, AND 4TH FLR
 COULD NOT BE LOCATED ON PLANS.
  
 4)NOTE: PLEASE CLARIFY LOCATION FOR
 A/C EQUIPMENT. 210.63
  
 5)NOTE: PLEASE SEE RISER SHOWS TWO
 "MAINS 1 OF 2". (MISPRINT)
  
 6)NOTE: PLEASE SEE PANEL 1R1. RISER
 APPEARS TO SHOW THIS FEEDING1R2 BUT
 PANEL DOES NOT INDICATE BEING "FEED THRU
 LUGS". PLEASE CLARIFY.
  
 7)NOTE: PLEASE CORRELATE ALL PANELS ON
 RISER DIAGRAM WITH INFORMATION GIVEN
 ON PANEL SCHEDULES. MANY PANELS ON
 RISER ARE SHOWN W/ DIFFERENT AMPERAGE
 RATINGS,THAN WHAT IS SHOWN ON PANELS.
 EQA,EQ,LDY,L,LR,4AC2,3AC2,2AC2 .
 PLEASE SEE LR SHOWN AS 100 WITH 125A
 FEED.
  
 8)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
 AIC RATING IS SHOWN FOR MAIN, HOWEVER NO
 INFORMATION FOR PANEL AND BRANCH BRKRS
 ARE SHOWN. THYE ARE BLANK.
  
 9)NOTE: PLEASE PROVIDE INFORMATION ON
 ENCLOUSURE/GUTTER FOR WHAT APPEARS TO
 BE TAPS TO ELEVATOR MOTORS. PLEASE ALSO
 PROVIDE AIC RATING AND MORE INFORMATION
 FOR MAIN 1 OF 2 FOR ELEVATORS.
 110.9
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2004-03-09 Cont ID  
Sent By mamini Date 2004-03-09 Time 11:29 Rev Time 1.00
Received By mamini Date 2004-03-09 Time 11:29 Sent To  
Notes
2004-03-09 00:00:00PASSED:
 1. THE APPLICANT APPLIED FOR SEPARATE
 PERMIT FOR UNDERGROUND UTILITIES AND
 SITE WORK. SEE # 04030446.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2004-03-08 Cont ID  
Sent By mamini Date 2004-03-08 Time 10:15 Rev Time 1.00
Received By mamini Date 2004-03-08 Time 10:14 Sent To  
Notes
2004-03-08 00:00:00PASSED WITH PROVISOS:
 1. ALL COMMMENTS FROM PUBLIC UTILITIES
 & ENGINEEERING MUST BE ADDRESSED AND
 IMPLEMENTED, REVISIONS TO CIVIL PLANS
 MUST BE SUBMITED TO BUILDING DEPARTMENT.
 2. PLEASE SUBMIT COPY OF SFWMD PERMIT
 UPON RECEIVING.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2004-01-27 Cont ID  
Sent By mamini Date 2004-01-27 Time 15:03 Rev Time 1.00
Received By mamini Date 2004-01-27 Time 15:03 Sent To  
Notes
2004-01-27 00:00:00FAILED:
 1. PLEASE SUBMIT CIVIL PLANS TO PUBLIC
 UTILITIES AND ENGINEERING SERVICES FOR
 THEIR REVIEW AND CONNECTION TO CITY
 SERVICES, ATT; MANNY GONZALEZ 659-8040
 EXT. 2306.
 2. PLEASE SUBMIT STORM WATER CALCULATION
 FOR OUR REVIEW AND APPROVAL, IT MUST
 INCLUDE PERVIOUS AND IMPERVIOUS AREA FOR
 THE TOTAL SITE.
 3. PLEASE INCLUDE POLLUTION/EROSION
 PREVENTION IN CIVIL PLANS.
 4. PLESAE NOTE THAT ALL OFF STREET
 PARKING MUST BE PAINTED WITH DOUBLE 4"
 WIDE STRIPES, SHEET C-3.
 5. PLEASE SUBMIT A COPY OF SFWMD PERMIT.
 6. PLEASE NOTE THAT APPROACHES TO THE
 SITE MUST BE CONSTRUCTED WITH 6"
 CONCRETE FROM EDGE OF THE PAVEMENT TO
 THE PROPERTY LINE, PER CITY REQUIREMENT.
 7. EXISTING SIDEWALK ALONG PROPERTY ALL
 SIDE IF DAMAGED DURING THE CONSTRUCTION
 MUST BE REPACED TO BETTER OR ORIGINAL
 CONDITION.
 8. PROPOSED DRANAGE SYS. SHOULD BE
 SHOWN ON SHEET C-1 INSTEAD OF C-2,
 LINEAR FEET OF EACH RUN FOR PIPES AND
 EXFILTRATION MUST BE SHOWN.
 9. PLEASE NOTE THAT NO CONSTRUCTION OR
 LANDSCAPING IN EASMENT AREAS IS ALLOWED.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2005-01-04 Cont ID  
Sent By nmccray Date 2005-01-04 Time 15:53 Rev Time 0.00
Received By nmccray Date 2005-01-04 Time 15:53 Sent To  
Notes
2005-01-04 00:00:00FIRE ALARM REVISION

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status F Date 2004-08-16 Cont ID  
Sent By nmccray Date 2004-08-16 Time 11:09 Rev Time 0.00
Received By nmccray Date 2004-08-16 Time 11:09 Sent To  
Notes
2004-08-16 00:00:00*************DENIED*********************
 1) AUTOMATIC SLIDING DOORS SHALL COMPLY
 WITH NFPA 101 2000 EDITION CH 7.2.1.9
 AND CH 7.2.1.14
  
 2) LAUNDRY CHUTES SHALL COMPLY WITH NFPA
 FIRE PREVENTION CODE 2000 EDITION CH 6-6
 AND NFPA 101 2000 EDITION CH 8-2
  
 NATE MCCRAY, CAPTAIN
 835-2910 OR 805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2004-03-30 Cont ID  
Sent By mcarsill Date 2004-03-30 Time 12:50 Rev Time 0.00
Received By mcarsill Date 2004-03-30 Time 12:46 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2004-03-12 Cont ID  
Sent By mcarsill Date 2004-03-12 Time 07:15 Rev Time 0.00
Received By mcarsill Date 2004-03-12 Time 07:15 Sent To  
Notes
2004-03-12 00:00:001) THE FP-1 PAGE DOES NOT CORRESPOND
 WITH C-2.
  
 2) IS THE FIRE STANDPIPE/ SPRINKLER
 ISOMETRIC DRAWING CORRECT.
  
 3) STORAGE ROOM AND SUNDRIES STORAGE
 NOT PROTECTED BY FIRE SPRINKLERS.
  
 4) MEN'S AND WOMEN'S RESTROOM 163
 AND 164 NOT SPRINKLER PROTECTED.
  
 5) ALL SMOKE DETECTORS SHALL BE
 INSTALLED A MINIMUM OF THREE FEET
 FROM AC DIFFUSERS.
  
 6) PLEASE VERIFY TYPICAL ELECTRICAL
 DRAWINGS ON PAGE E-7 AND VERIFY
 THAT ENOUGH SMOKE DETECTORS ARE
 PRESENT.
  
 7) SOME EXIT SIGNS APPEAR TO BE
 MISSING FROM THE FIRST FLOOR.
  
 8) SMOKE DETECTOR MISSING FROM STORAGE
 ROOM 113.
  
 9) BUILDING ADDRESS REQUIRED. A MINIMUM
 OF 6" NUMBERS REQUIRED.
  
 10) LOCKING DEVICES ON EXIT DOORS TO
 COMPLY WITH THE LIFE SAFETY CODE.
  
 11) PLEASE DISPLAY ALL AVAILABLE
 FIRE HYDRANTS LOCATED NEAR THE SITE.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-01-16 Cont ID  
Sent By mcarsill Date 2004-01-16 Time 16:04 Rev Time 0.00
Received By mcarsill Date 2004-01-16 Time 16:04 Sent To  
Notes
2004-01-16 00:00:001) TEMPORARY STANDPIPE SYSTEM IS
 REQUIRED WHEN THE BUILDING REACHES
 THREE FLOORS OR 30 FEET IN HEIGHT
 WHILE THE BUILDING IS UNDER
 CONSTRUCTION.
  
 2) CONSTRUCTION, DEMOLITION, AND
 RENOVATION TO COMPLY WITH NFPA 241.
  
 3) BUILDING ADDRESS REQUIRED.
  
 4) A KNOX-BOX WILL BE REQUIRED.
  
 5) TACTILE SIGNAGE REQUIRED AT ALL
 STAIRWELLS.
  
 6) EMERGENCY INSTRUCTIONS FOR GUESTS
 SHALL BE POSTED.
  
 7) ALL GUEST LAUNDRIES GREATER THAN
 100 SQUARE FEET SHALL BE PROTECTED
 WITH ONE HOUR CONSTRUCTION AND
 FIRE SPRINKLERS. MAINTENANCE SHOPS
 AND TRASH COLLECTION ROOMS SHALL HAVE
 ONE HOUR CONSTRUCTION AND SPRINKLERS.
  
 8) STANDPIPE SYSTEM HOSE VALVES SHALL
 BE PLACED WITHIN STAIRWELLS ON
 EVERY FLOOR.
  
 9) THE COVERED OVERHANG SHALL BE AT
 LEAST 13'- 6" SO FIRE AND PARAMEDICAL
 CAN PASS UNDERNEATH IT.
  
 10) PLEASE INDICATE INTERIOR FINISH
 FOR WALLS AND CEILINGS.
  
 11) ANY AREAS OF REFUGE SHALL MEET
 ALL OF THE REQUIREMENTS OF THE
 FLORIDA FIRE PREVENTION CODE.
  
 12) ALL GUESTROOMS FOR HEARING
 IMPAIRED SHALL BE PROVIDED WITH
 FIRE ALARM VISUAL APPLIANCES.
  
 13) PLEASE PROVIDE PRESCRIPTIVE
 DETAILS FOR ALL HANDRAILS AND
 GUARDRAILS.
  
 14) SOME BATHROOMS ARE SPRINKLER
 PROTECTED IN GUESTROOMS AND SOME ARE
 NOT. PLEASE EXPLAIN RATIONALE.
  
 15) BATHROOMS 163 AND 164 ARE NOT
 FIRE SPRINKLER PROTECTED. WHY?
  
 16) THE FDC IS NOT SHOWN ON FIRST
 FLOOR FIRE SPRINKLER PLAN. WHY?
  
 17) NOTE # 11 ON PAGE FA-4 IS NOT
 CORRECT. DUCT DETECTORS WHEN ACTIVATED
 SHALL CAUSE A GENERAL ALARM.
  
 18) FIRE ALARM CIRCUITS SHALL BE
 CLASS A OR FULLY ADDRESSABLE. NOTE
 # 8 ON PAGE FA-4 INDICATES CIRCUITS
 WILL BE CLASS B.
  
 19) THE FIRE ALARM SYSTEM SHALL BE
 UL LISTED FOR CENTRAL STATION SERVICE.
  
 20) ELEVATOR WARNING SIGNS REQUIRED
 AT ELEVATORS.
  
 21) SINGLE STATION SMOKE DETECTORS
 ARE REQUIRED IN EVERY LIVING AREA
 AND SLEEPING ROOM WITHIN GUEST SUITE.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2004-12-21 Cont ID  
Sent By kstevens Date 2004-12-21 Time 15:19 Rev Time 0.60
Received By kstevens Date 2004-12-21 Time 15:19 Sent To  
Notes
2004-12-21 00:00:00DENIED
 REFERENCE: FBC-2001 FUEL GAS
  
 LETTER FROM ANDREW J. YOUNGROSS P.E.
 DATED DECEMBER 16, 2004 CHANGING THE
 MAIN 3" SHUT OFF VALVE FOR THE GAS
 SYSTEM IS NOT ACCEPTABLE. PER TABLE
 402(2) THE MAXIMUM BTU'S ALLOWED FOR 2"
 PIPE AND VALVE IS 1,020,000 BTU'S AND
 THE TOTAL BTU LOAD ON THE SYSTEM IS
 2,195,000 BTU'S. A 3" SOV IS REQUIRED.
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 35 Status N Date 2005-01-21 Cont ID  
Sent By mjacobs Date 2005-01-21 Time 10:54 Rev Time 0.00
Received By mjacobs Date 2005-01-21 Time 10:54 Sent To E
Notes
2005-01-21 00:00:00TO "JL" DESK./REV

Review Stop I INCOMING/PROCESSING
Rev No 34 Status N Date 2004-12-29 Cont ID  
Sent By mjacobs Date 2004-12-29 Time 14:19 Rev Time 0.00
Received By mjacobs Date 2004-12-29 Time 14:19 Sent To FIRE
Notes
2004-12-29 00:00:00TO "FIRE" BOX.

Review Stop I INCOMING/PROCESSING
Rev No 33 Status N Date 2004-12-17 Cont ID  
Sent By mjacobs Date 2004-12-17 Time 15:34 Rev Time 0.00
Received By mjacobs Date 2004-12-17 Time 15:34 Sent To M
Notes
2004-12-17 00:00:00SENT TO "M/AC" BOX. ONE SUBMMITAL TO "P"
 BOX ALSO.

Review Stop I INCOMING/PROCESSING
Rev No 32 Status N Date 2004-12-01 Cont ID  
Sent By mjacobs Date 2004-12-01 Time 18:44 Rev Time 0.00
Received By mjacobs Date 2004-12-01 Time 18:44 Sent To E
Notes
2004-12-01 00:00:00SENT TO "E" TO DP. DESK.

Review Stop I INCOMING/PROCESSING
Rev No 31 Status N Date 2004-11-15 Cont ID  
Sent By csiegber Date 2004-11-15 Time 09:27 Rev Time 0.00
Received By csiegber Date 2004-11-15 Time 09:27 Sent To M
Notes
2004-11-15 00:00:00TO PK BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 30 Status N Date 2004-10-27 Cont ID  
Sent By csiegber Date 2004-10-27 Time 10:27 Rev Time 0.00
Received By csiegber Date 2004-10-27 Time 10:27 Sent To P
Notes
2004-10-27 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 29 Status N Date 2004-10-18 Cont ID  
Sent By csiegber Date 2004-10-18 Time 15:03 Rev Time 0.00
Received By csiegber Date 2004-10-18 Time 15:03 Sent To Z
Notes
2004-10-18 00:00:00TO LANDSCAPE

Review Stop I INCOMING/PROCESSING
Rev No 28 Status N Date 2004-10-07 Cont ID  
Sent By csiegber Date 2004-10-07 Time 14:50 Rev Time 0.00
Received By csiegber Date 2004-10-07 Time 14:50 Sent To M
Notes
2004-10-07 00:00:00TO PK BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 27 Status N Date 2004-10-06 Cont ID  
Sent By csiegber Date 2004-10-06 Time 10:06 Rev Time 0.00
Received By csiegber Date 2004-10-06 Time 10:06 Sent To  
Notes
2004-10-06 00:00:00TO COMM BD#25

Review Stop I INCOMING/PROCESSING
Rev No 26 Status N Date 2004-10-05 Cont ID  
Sent By csiegber Date 2004-10-05 Time 15:14 Rev Time 0.00
Received By csiegber Date 2004-10-05 Time 15:14 Sent To B
Notes
2004-10-05 00:00:00TO LM DESK/SUBMITTAL
 SHOP DRAWS & TRUSS DRAWS

Review Stop I INCOMING/PROCESSING
Rev No 25 Status N Date 2004-09-22 Cont ID  
Sent By csiegber Date 2004-09-22 Time 11:11 Rev Time 0.00
Received By csiegber Date 2004-09-22 Time 11:11 Sent To P
Notes
2004-09-22 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 24 Status N Date 2004-08-30 Cont ID  
Sent By csiegber Date 2004-08-30 Time 10:29 Rev Time 0.00
Received By csiegber Date 2004-08-30 Time 10:29 Sent To P
Notes
2004-08-30 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 23 Status N Date 2004-08-30 Cont ID  
Sent By csiegber Date 2004-08-30 Time 10:28 Rev Time 0.00
Received By csiegber Date 2004-08-30 Time 10:28 Sent To E
Notes
2004-08-30 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 22 Status N Date 2004-08-30 Cont ID  
Sent By csiegber Date 2004-08-30 Time 09:27 Rev Time 0.00
Received By csiegber Date 2004-08-30 Time 09:27 Sent To M
Notes
2004-08-30 00:00:00TO PK BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 21 Status N Date 2004-08-18 Cont ID  
Sent By csiegber Date 2004-08-18 Time 16:48 Rev Time 0.00
Received By csiegber Date 2004-08-18 Time 16:48 Sent To P
Notes
2004-08-18 00:00:00TO KS BOX/SUBMITTAL
 DELETION OF WATER HAMMER

Review Stop I INCOMING/PROCESSING
Rev No 20 Status N Date 2004-08-18 Cont ID  
Sent By csiegber Date 2004-08-18 Time 16:47 Rev Time 0.00
Received By csiegber Date 2004-08-18 Time 16:47 Sent To E
Notes
2004-08-18 00:00:00TO DP DESK/SUBMITTAL
 USE OF ENT CONDUIT

Review Stop I INCOMING/PROCESSING
Rev No 19 Status N Date 2004-08-16 Cont ID  
Sent By csiegber Date 2004-08-16 Time 16:39 Rev Time 0.00
Received By csiegber Date 2004-08-16 Time 16:39 Sent To B
Notes
2004-08-16 00:00:00TO SH DESK/SUBMITTAL
 PLUMBER'S FIRESTOP SYSTEM

Review Stop I INCOMING/PROCESSING
Rev No 18 Status N Date 2004-08-16 Cont ID  
Sent By csiegber Date 2004-08-16 Time 09:10 Rev Time 0.00
Received By csiegber Date 2004-08-16 Time 09:10 Sent To B
Notes
2004-08-16 00:00:00TO SH DESK/SUBMITTAL
 DETAIL FOR HEAD JOINTS IN MASONARY

Review Stop I INCOMING/PROCESSING
Rev No 17 Status N Date 2004-08-10 Cont ID  
Sent By shill Date 2004-08-10 Time 08:36 Rev Time 0.00
Received By shill Date 2004-08-10 Time 08:36 Sent To B
Notes
2004-08-10 00:00:00SUBMITTAL TO LM DESK

Review Stop I INCOMING/PROCESSING
Rev No 16 Status N Date 2004-08-10 Cont ID  
Sent By csiegber Date 2004-08-10 Time 07:49 Rev Time 0.00
Received By csiegber Date 2004-08-10 Time 07:49 Sent To B
Notes
2004-08-10 00:00:00TO SH DESK/SUBMITTAL
 REPAIR DETAIL -LOUVER PENETRATIONS

Review Stop I INCOMING/PROCESSING
Rev No 15 Status N Date 2004-08-10 Cont ID  
Sent By csiegber Date 2004-08-10 Time 07:48 Rev Time 0.00
Received By csiegber Date 2004-08-10 Time 07:48 Sent To E
Notes
2004-08-10 00:00:00TO DP DESK/SUBMITTAL
 USE OF M.C. CABLE

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2004-07-30 Cont ID  
Sent By csiegber Date 2004-07-30 Time 16:42 Rev Time 0.00
Received By csiegber Date 2004-07-30 Time 16:42 Sent To B
Notes
2004-07-30 00:00:00TO SH DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2004-07-30 Cont ID  
Sent By csiegber Date 2004-07-30 Time 16:40 Rev Time 0.00
Received By csiegber Date 2004-07-30 Time 16:40 Sent To  
Notes
2004-07-30 00:00:00TO COMM BD#60

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2004-07-30 Cont ID  
Sent By csiegber Date 2004-07-30 Time 16:32 Rev Time 0.00
Received By csiegber Date 2004-07-30 Time 16:32 Sent To B
Notes
2004-07-30 00:00:00TO 3 LETTERSOF CLARIFICATION
 1 REVISED STRUCTURAL

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2004-07-30 Cont ID  
Sent By csiegber Date 2004-07-30 Time 16:32 Rev Time 0.00
Received By csiegber Date 2004-07-30 Time 16:32 Sent To B
Notes
2004-07-30 00:00:00TO SH DESK/SUBMITTAL ROOF

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2004-06-11 Cont ID  
Sent By csiegber Date 2004-06-11 Time 09:06 Rev Time 0.00
Received By csiegber Date 2004-06-11 Time 09:05 Sent To B
Notes
2004-06-11 00:00:00TO SH DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2004-06-08 Cont ID  
Sent By csiegber Date 2004-06-08 Time 13:24 Rev Time 0.00
Received By csiegber Date 2004-06-08 Time 13:24 Sent To B
Notes
2004-06-08 00:00:00TO SH DESK/REVISED 12 STRUCTURAL SHEETS

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2004-06-08 Cont ID  
Sent By csiegber Date 2004-06-08 Time 11:56 Rev Time 0.00
Received By csiegber Date 2004-06-08 Time 11:56 Sent To B
Notes
2004-06-08 00:00:00TO SH DESK/SUBMITTAL/SECONDARY POUR

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2004-05-27 Cont ID  
Sent By csiegber Date 2004-05-27 Time 11:39 Rev Time 0.00
Received By csiegber Date 2004-05-27 Time 11:39 Sent To B
Notes
2004-05-27 00:00:00TO LM DESK/SUBMITTAL/ENGD SHORING SHOP
 DRAWS/SIGNED & SEALED

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-05-17 Cont ID  
Sent By csiegber Date 2004-05-17 Time 08:32 Rev Time 0.00
Received By csiegber Date 2004-05-17 Time 08:32 Sent To B
Notes
2004-05-17 00:00:00TO LM DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-04-16 Cont ID  
Sent By csiegber Date 2004-04-16 Time 16:42 Rev Time 0.00
Received By csiegber Date 2004-04-16 Time 16:42 Sent To P
Notes
2004-04-16 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-04-06 Cont ID  
Sent By csiegber Date 2004-04-06 Time 07:44 Rev Time 0.00
Received By csiegber Date 2004-04-06 Time 07:44 Sent To  
Notes
2004-04-06 00:00:00TO LM/ENG TO LOOK AT THIS

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-03-25 Cont ID  
Sent By csiegber Date 2004-03-25 Time 16:11 Rev Time 0.00
Received By csiegber Date 2004-03-25 Time 16:11 Sent To  
Notes
2004-03-25 00:00:00TO COMM BD#59

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-04 Cont ID  
Sent By csiegber Date 2004-03-04 Time 16:12 Rev Time 0.00
Received By csiegber Date 2004-03-04 Time 16:12 Sent To  
Notes
2004-03-04 00:00:00TO COMM BD#59/ROLLS ON RACK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-01-15 Cont ID  
Sent By mmclean Date 2004-01-16 Time 10:28 Rev Time 0.00
Received By csiegber Date 2004-01-15 Time 16:55 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 10 Status N Date 2004-12-21 Cont ID  
Sent By pkrauss Date 2004-12-21 Time 15:13 Rev Time 0.40
Received By pkrauss Date 2004-12-21 Time 15:13 Sent To  
Notes
2004-12-21 00:00:00REVISION; AHU HANGING DETAIL/CHANGE IN
 CONDENSATE TRAP.

Review Stop M MECHANICAL (A/C)
Rev No 9 Status P Date 2004-11-29 Cont ID  
Sent By pkrauss Date 2004-11-29 Time 08:14 Rev Time 0.55
Received By pkrauss Date 2004-11-29 Time 07:45 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 8 Status P Date 2004-10-20 Cont ID  
Sent By pkrauss Date 2004-10-20 Time 10:32 Rev Time 0.30
Received By pkrauss Date 2004-10-20 Time 10:23 Sent To  
Notes
2004-10-20 00:00:00REVISION #7/DUCT SIZE CHANGE FROM
 LOUNGE AREA

Review Stop M MECHANICAL (A/C)
Rev No 7 Status P Date 2004-10-15 Cont ID  
Sent By pkrauss Date 2004-10-15 Time 09:59 Rev Time 1.00
Received By pkrauss Date 2004-10-15 Time 09:59 Sent To  
Notes
2004-10-15 00:00:00REVISION #5 DATED 10-5-04 & #6 DATED
 10-14-04.

Review Stop M MECHANICAL (A/C)
Rev No 6 Status N Date 2004-10-12 Cont ID  
Sent By pkrauss Date 2004-10-12 Time 12:43 Rev Time 1.10
Received By pkrauss Date 2004-10-12 Time 12:04 Sent To  
Notes
2004-10-12 00:00:00PROVISO:
 ISOMETRIC DIAGRAM-WATER HEATER FLUE
 SYSTEM ON PLAN SHEET P-14, VENTING OF
 GAS APPLIANCES SHOULD BE REFERENCED
 UNDER THE MECHANICAL PLANS.WHEN
 APPLIANCES ARE COMBINED AND A COMMON
 VENT IS USED, THE VENT CAPACITY SHALL
 COMPLY WITH 2001 FBC, FUEL GAS 502.3.20.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2004-10-08 Cont ID  
Sent By pkrauss Date 2004-10-08 Time 07:48 Rev Time 0.40
Received By pkrauss Date 2004-10-08 Time 07:22 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2004-09-16 Cont ID  
Sent By pkrauss Date 2004-09-16 Time 06:58 Rev Time 0.55
Received By pkrauss Date 2004-09-16 Time 06:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2004-08-16 Cont ID  
Sent By csiegber Date 2004-08-30 Time 09:28 Rev Time 0.55
Received By pkrauss Date 2004-08-16 Time 13:14 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-03-17 Cont ID  
Sent By pkrauss Date 2004-03-17 Time 16:06 Rev Time 0.55
Received By pkrauss Date 2004-03-17 Time 16:06 Sent To  
Notes
2004-03-17 00:00:00PROVISO:
 1.AUXILIARY DRAIN PAN WITH OVERFLOW
 PROTECTION REQUIRED PER 2001 FBC(M)
 307.2.3.
  
 2.4" CLEARANCE AROUND THE AHU IS
 REQUIRED PER 2001 FBC(M) 603.1.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-01-29 Cont ID  
Sent By pkrauss Date 2004-01-29 Time 15:57 Rev Time 0.00
Received By pkrauss Date 2004-01-29 Time 15:57 Sent To  
Notes
2004-01-29 00:00:00DENIED:
 PLEASE NOTE A-4 INDICATES THE FOLLOWING
 WALLS/PARTITIONS AS #7 (1 HR):
 ROOM #160,161,162,154,& 153, PLEASE NOTE
 DUCTS ARE NOT REQUIRED TO HAVE FIRE
 DAMPERS SHOULD THEY COMPLY WITH 2001
 FBC(M) 607.1.3 #3 1 THRU 4.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 11 Status P Date 2004-11-03 Cont ID  
Sent By kstevens Date 2004-11-03 Time 13:33 Rev Time 1.00
Received By kstevens Date 2004-11-03 Time 13:33 Sent To  
Notes
2004-11-03 00:00:00REVISION OK - GAS PIPE SIZING AND PIPE
 ROUTING. - STORM PIPE ROUTING - ADD
 CONDENSATE LINE UP TO ROOF

Review Stop P PLUMBING
Rev No 10 Status P Date 2004-10-15 Cont ID  
Sent By kstevens Date 2004-10-15 Time 17:44 Rev Time 3.00
Received By kstevens Date 2004-10-15 Time 17:44 Sent To  
Notes
2004-10-15 00:00:00REVISIONS OK FOR SHEETS P-10, P-12, P-14
 & P-16 - DENIED P-9
  
 REVISION DENIED
  
 SHT P-9 GAS RISER DIAGRAM DENIED. 2" RE-
 QUIRED UP TO FIRST DRYER AND 1-1/2" RE-
 QUIRED UP TO SECOND DRYER. - NFPA NOT
 ADOPTED FOR GAS SIZING, AND PIPING SHALL
 BE SIZED BY FBC-2001 FUEL GAS CODE TABLE
 402(2). - RESIZE PIPING PER APPROVED
 CODE TABLE AND RESUBMIT GAS RISER REVIS-
 ION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 9 Status F Date 2004-10-12 Cont ID  
Sent By kstevens Date 2004-10-12 Time 10:08 Rev Time 1.25
Received By kstevens Date 2004-10-12 Time 10:08 Sent To M
Notes
2004-10-12 00:00:00REVISION FOR SHEETS P-13 & P-15 OK
 REVISION FOR SHEET P-14 DENIED

Review Stop P PLUMBING
Rev No 8 Status F Date 2004-09-21 Cont ID  
Sent By kstevens Date 2004-09-21 Time 13:50 Rev Time 3.50
Received By kstevens Date 2004-09-20 Time 18:49 Sent To  
Notes
2004-09-21 00:00:00REVISISON DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 1
  
 A) SHT P-9 FROM PREVIOUS REVIEW:
 1. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2001
 FUEL GAS CODE.- MANY LENGTHS ARE NOT
 SHOWN FOR CUT SECTIONS OF PIPES. SEE
 RED LINE MARKS FOR SECTIONS WITH NO
 LENGTHS SHOWN,
 2) SHT P-10 REVISION #4 NOT FOUND.
 PLEASE CLAIRFY. SECTION 104.2.1
 3) SHT P10 NEW EMERGENCY OVERFLOW DRAINS
 SHOWN ON REVISIONS ARE NOT APPROVED.
 ROOF DRAINS L1, L2, L5, L6, & L7 REQUIRE
 50.24 SQ IN, TWO 6" DRAINS PROVIDE 56.54
 SQ IN. BUT FOUR 3" DRAINS ONLY PROVIDE
 28.26 SQ IN. - EMERGENCY OVERFLOW DRAINS
 FOR L3, & L4 REQUIRE 28.26 SQ IN, BUT
 TWO 3" DRAINS ONLY PROVIDE 14.13 SQ IN.
 SECTION 1107
 4) FROM PREVIOUS REVIEW: THE CLEANOUTS
 REQUIRED IN SECTION 708.3.1 ARE NOT TO
 BE DELETED. NO EXCEPTION TO THIS SECTION
 IS NOTED IN THE CODE.
 5) VACUUM RELIEF VALVES REQUIRED BY SEC-
 TION 504.2 ARE NOT SHOWN IN THE PROPER
 LOCATION. THESE VALVES SHALL BE LOCATED
 ON THE SUPPLY SIDE OF THE HEATER AND BE
 ABOVE THE TOP OF THE HEATERS. WATER
 HEATERS ONE AND TWO SHOW THEM INSTALLED
 ON THE HOT WATER SIDE. WATER HEATER
 THREE AND THE STORAGE TANK HAVE NO VAC-
 UUM RELIEF VALVES SHOWN. WILL WATER
 HEATERS ONE AND TWO BE INSTALLED STACKED
 AS SHOWN? WATER HEATERS SHOULD BE INST-
 ALLED SO THAT THEY ARE PIPED IN PARALLEL
 AND THE SUPPLY AND HOT WATER TIE IN THE
 CENTER OF THE HEATERS SO THEY HEAT AND
 ARE USED SIMULTAINIOUSLY. SECTION 104.2.
 1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 7 Status F Date 2004-08-25 Cont ID  
Sent By csiegber Date 2004-08-30 Time 10:29 Rev Time 0.25
Received By kstevens Date 2004-08-25 Time 17:59 Sent To  
Notes
2004-08-25 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
 FBC-2001 PLUMBING
  
 - SUBMITTAL LETTER FOR REVISION OF THE
 WATER RISER DIAGRAM IS NOT APPROVED. THE
 WATER RISER DIAGRAM SHALL BE REVISED TO
 SHOW CHANGES IN THE FIELD FOR PUBLIC
 RECORD. PLEASE SUBMIT CHANGES IN THE
 FORM OF A REVISED WATER DIAGRAM SHOWING
 ALL WATER HAMMER ARRESTORS REQUIRED BY
 SECTION 604.9 - SECTION 104.2.1
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 6 Status F Date 2004-08-12 Cont ID  
Sent By csiegber Date 2004-08-18 Time 16:48 Rev Time 3.75
Received By kstevens Date 2004-08-11 Time 18:56 Sent To  
Notes
2004-08-12 00:00:00REVISION DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 1
  
 1. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2001
 FUEL GAS CODE. NEW RISER DIAGRAM DOES
 NOT SHOW LENGTH OF PIPING TO POOL HEATER
 SHEET P-9.
 2. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2001 FUEL GAS CODE SECS. 401.8
 THRU 402.5.2 AND TABLES 402(1) THRU
 402(34). SHEET P-9CHANGES IN PIPE SIZE
 MAY BE REQUIRED WITH THE ADDITION BTU'S
 FROM POOL HEATER.
 3. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2001 FUEL GAS CODE SEC 402.2 - SHEET
 P-9 MANUF. SHEETS REQUIRED FOR POOL
 HEATER VERIFYING BTU'S AND LISTING.
 4) SHT P-10 TWO 3" OVERFLOW DRAINS ARE
 NOT APPROVED. - UPON REVIEW OF PLANS
 THE MAXIMUM SQUARE FOOTAGE ALLOWED ON
 HORIZONTAL SECONDARY 6" DRAINS IS 2,378.
 ANY AREAS WITH MORE SQUARE FOOTAGE SHALL
 BE REQUIRED TO HAVE AN 8" HORIZONTAL
 DRAIN. 6" IS REQUIRED FOR THE TWO SMALL-
 ER AREAS OF THE ROOF. TWO PIPES 1/2 THE
 AREA DO NOT EQUAL THE SAME AREA AS THE
 1 PIPE TWICE THE SIZE. TABLES 1106.2 &
 1106.3 @ 4.5 INCHES RAIN PER HR.
 5) SHT P-12 CLEANOUTS ARE REQUIRED A
 MINIMUM OF 100' IN THE BUILDING DRAIN.
 REMOVING THE CLEANOUT IS NOT APPROVED.
 SECTION 708.3.1
 6) SHT P-14 SHOW CORRECT LOCATIONS OF
 THE VACUUM RELIEF VALVES REQUIRED FOR
 THE BOTTOM FED WATER HEATERS AS REQUIRED
 IN SECTION 504.2. SEE CORRECTIONS ON
 STAMPED SET OF PLANS AND REVISE THESE
 CORRECTIONS AS THIS REVISION IS AN AS-
 BUILT REVISION. SECTION 104.2.1
 7) ALL CHANGES TO STORM PIPING SHALL BE
 REFLECTED ON THE STORM RISER DIAGRAMS.
 SECTION 104.2.1
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 5 Status P Date 2004-04-26 Cont ID  
Sent By kstevens Date 2004-04-26 Time 16:32 Rev Time 1.00
Received By kstevens Date 2004-04-26 Time 16:32 Sent To  
Notes
2004-04-26 00:00:00REVISION OK - CHANGED BLDG DRAIN FROM
 1 8" LINE TO 2 6" LINES EXITING BLDG.

Review Stop P PLUMBING
Rev No 4 Status P Date 2004-03-30 Cont ID  
Sent By csiegber Date 2004-04-16 Time 16:42 Rev Time 1.00
Received By kstevens Date 2004-03-30 Time 11:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2004-03-26 Cont ID  
Sent By kstevens Date 2004-03-26 Time 17:45 Rev Time 2.50
Received By kstevens Date 2004-03-26 Time 17:44 Sent To  
Notes
2004-03-26 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
 1) SHT P-16 LOWER ROOF ON N-WEST SIDE
 SHOWS 6" STORM DRAIN, THEN AFTER SECOND
 ROOF DRAIN SHOWS 4" STORM DRAIN. MINIMUM
 8" STORM DRAIN REQUIRED AFTER SECOND
 ROOF DRAIN.
 2) SHT P-9 STORM DRAIN LINE FROM (L5)
 ADDS (L8) OUTSIDE BLDG. THIS DRAIN WAS
 NOT FOUND. PLEASE CLAIRFY AND INDICATE
 WHERE L8 CAN BE LOCATED.
 3) MEASUREMENTS STILL MISSING FOR SOME
 ACCESSIBLE FIXTURES. NOT HEIGHT SHOWN
 FOR URINAL 11-4.18.2, HEIGHT & CLEARANC-
 ES FOR LAVS 11-4.19.2, EXPOSED PIPES AND
 SURFACES 11-4.19.4, SPOUT HEIGHT FOR THE
 DRINKING FOUNTAIN 11-4.15.2
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-03-16 Cont ID  
Sent By kstevens Date 2004-03-15 Time 18:29 Rev Time 7.00
Received By kstevens Date 2004-03-15 Time 18:29 Sent To  
Notes
2004-03-15 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
 A) FOLLOWING COMMENTS WERE NOT ADDRESSED
 OR COMMENT RESPONSE WAS NOT FOUND OR NOT
 ADDRESSED PROPERLY. THE COMMENT NUMBER
 FROM FIRST REVIEW WILL BE SHOWN TO AVOID
 CONFUSION.
 2) SHOW COMPLIANCE WITH SECTION 11-9.1.3
 ACCOMMODATIONS FOR PERSONS WITH HEARING
 IMPAIRMENT. - RESPONSE NOTED - FOUND 4
 UNITS PLUS ONE ACCESSIBLE UNIT WITH THIS
 ACCOMODATION. ONE ADDITIONAL UNIT WILL
 BE REQUIRED SEPARATE FROM ACCESSIBLE
 UNITS PER SECTION11-9.1.3
 4) SHT A-5 SUBMIT CALCULATIONS FOR LOWER
 ROOFS PER SECTION 1106 AND ALL SUBSECT-
 IONS. SHOW 1/2 AREA OF VERTICAL WALL
 ADDED TO SQUARE FOOTAGE OF ROOF IN CAL-
 CULATIONS. - NO CALCULATIONS WERE FOUND
 IN MECHANICAL PLANS. INDICATE SPECIFIC
 SHEET RESPONSE IS LOCATED. - PER CONVER-
 SATION WITH STEVE SHEET P-16 WILL BE
 SUBMITTED WITH THIS INFO.
 5) SUBMIT CALCULATIONS FOR PRIMARY AND
 SECONDARY ROOF DRAINS PER SECTIONS 1106
 AND 1107 AND ALL SUBSECTIONS. - RESPONSE
 TO SCUPPER COMMENT SEEN - BLDG OFFICIAL
 THINKS THAT IT WILL BE A LEAK PROBLEM.
 HE SAYS THAT A TROUGH MAY BE A BETTER
 SOLUTION. SUBMIT A DETAIL WITH MEASURE-
 MENTS SHOWING COVERAGE OF 6" PIPE ECT IF
 THIS IS THE SECONDARY DRAIN STILL WANTED
 6) SHTS A-27 & A-28 SHOW MEASUREMENTS
 FOR FIXTURES PER SEC'S 11-4.15, 11-4.16,
 11-4.18, 11-4.19, & 11-4.23 AND ALL SUB-
 SECTIONS. SHOW CLEAR FLOOR SPACE FOR ALL
 ACCESSIBLLE FIXTURES INCLUDING DRINKING
 FOUNTAINS, URNALS ECT. - RESPONSE NOTED
 SOME CLEAR FLOOR SPACES NOT SHOWN. ROOM
 117 EMPLOYEE LOUNGE SHOW CLEAR FLOOR
 FOR SINK. SHT A-12 KING DELUX ACCESSIBLE
 SHOW 5' TURNING AREA. SHT A-11 SHOW
 CLEAR FLOOR SPACE AT DRINKING FOUNTAINS.
 SHT A-15 SHOW CLEAR FLOOR SPACE FOR THE
 URINAL ROOM 114.
 10) SHT P-9 SEPARATE GAS PERMIT REQUIRED
 FOLLOWING INFORMATION REQUIRED FOR THE
 GAS PERMIT.
 B) SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED.- NO MATERIAL FOR PIPE LOCATED
 C) SUBMIT CALCULATIONS FOR COMBUSTION
 AIR PER FBC-2001 FUEL GAS CODE SECTION
 304. - RESPONSE NOTED. SHT M-1 CALCULAT-
 IONS INDICATE 2 DRYERS, BUT SHT P-9 GAS
 RISER SHOWS 3 DRYERS @ 165K BTU'S EACH
 PLEASE CLAIRFY. - ALSO 124 SQUARE INCHES
 IS REQUIRED AT DRYER IF VERTICAL DUCT
 BUT IF HORIZONTAL DUCT 247.5 SQ IN REQD.
 10" DUCT VERT WILL SUPPLY 78.5 SQ. IN.
 PLEASE SUBMIT DETAIL FOR DUCT. INDICATE
 IF VERTICAL OR HORIZONTAL, AND IF AIR
 IS OUTSIDE OR INSIDE AIR SUPPLYING THE
 COMBUSTION AIR. - SHOW COMBUSTION AIR
 CALCULATIONS FOR THE 80K BTU'S IN THE
 GUEST LAUNDRY ROOM.
 E) SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2001 FUEL GAS CODE SEC 402.2- RE-
 SPONSE NOTED, BUT NO MANUF. SHEETS WERE
 FOUND IN MECH. SHEETS.
 12) SHT P-10 ROOF DRAIN AND SQUARE FOOT-
 AGE NOT SHOWN FOR ROOF BELOW AT ENTRANCE
 16) LOCATION OF WATER HAMMER ARRESTORS
 SHALL BE NEAR THE FIXTURES IN AN
 "EFFECTIVE RANGE" NOT IN CEILING AS
 SHOWN. PDI-WH 201 AND MANUF. INSTALL.
 INSTRUCTIONS.
 17) SHT P-14 VACUUM RELIEF VALVES REQUI-
 RED FOR BOTTOM FED WATER HEATERS. SEC
 504.2 - RESPONSE NOTED, BUT THIS HAS NOT
 BEEN ADDRESSED.
 18) WATER HAMMER ARRESTORS SHALL BE
 LOCATED NEAR FIXTURE NOT IN CEILING.
 PDI-WH 201 AND MANUF. INSTALL. INSTRUCT.
 19) SEE COMMENTS 16 & 18.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-01-30 Cont ID  
Sent By kstevens Date 2004-01-30 Time 17:37 Rev Time 6.00
Received By kstevens Date 2004-01-30 Time 17:37 Sent To  
Notes
2004-01-30 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
 1) SHOW COMPLIANCE WITH SECTION 11-9.1.4
 CLASSES OF SLEEPING ACCOMMODATION. THE
 "KING SUITE DELUXE UNITS" HAVE NOT BEEN
 SHOWN TO HAVE ANY ACCESSIBLE UNITS.
 2) SHOW COMPLIANCE WITH SECTION 11-9.1.3
 ACCOMMODATIONS FOR PERSONS WITH HEARING
 IMPAIRMENT.
 3) SHOW COMPLIANCE WITH SECTION 11-9.2.3
 ONE UNIT REQUIRED UNDER THIS SECTION.
 4) SHT A-5 SUBMIT CALCULATIONS FOR LOWER
 ROOF PER SEC 1106 AND ALL SUBSECTIONS.
 SHOW 1/2 AREA OF VERTICAL WALL ADDED TO
 SQUARE FOOTAGE OF ROOF IN CALCULATIONS.
 5) SUBMIT CALCULATIONS FOR PRIMARY AND
 SECONDARY ROOF DRAINS PER SECTIONS 1106
 AND 1107 AND ALL SUBSECTIONS. - SCUPPERS
 ARE 36 FEET OR MORE FROM SOME OF THE
 ROOF DRAINS. AT 1/4" PER FOOT SLOPE AND
 THE SCUPPERS 2" TO 4" TO FLOW LINE, THE
 PONDING WILL BE APPROXIMATELY 13" DEEP
 NEAR THE DRAIN. THIS WILL PLACE WEIGHT
 OF 4.5 TO 6 INCHES OF WATER ON ROOF BE-
 FOR THE RAIN WATER WILL START TO DRAIN
 THRU THE SCUPPERS. SUBMIT CALCULATIONS
 FOR ROOF TO SHOW IT WILL SUPPORT THIS
 WEIGHT.
 6) SHTS A-27 & A-28 SHOW MEASUREMENTS
 FOR FIXTURES PER SEC'S 11-4.15, 11-4.16,
 11-4.18, 11-4.19, AND 11-4.23 AND ALL
 SUBSECTIONS. SHOW CLEAR FLOOR SPACE FOR
 ALL ACCESSIBLE FIXTURES INCLUDING DRINK-
 ING FOUNTAINS, URNALS ECT.
 7) SHTS A-15.1 & A-28 PRIVATE BATHROOM
 SHALL BE ADAPTABLE. SHOW DETAIL FOR
 SHOWER BACKING, CURB, VALVE HEIGHT, AND
 OPENING FOR WATER CLOSET AND CLEAR FLOOR
 SPACE AND TURNING AREA ECT.
 8) SHT A-34 SEPARATE PLANS & PERMIT REQ-
 UIRED FOR POOL. PLANS TO BE SUBMITTED TO
 PALM BEACH COUNTY HEALTH DEPT. FOR APP-
 ROVAL PRIOR TO SUBMITTING TO CITY WPB
 FOR REVIEW.
 9) SHT P-1 PLUMBING NOTES #13, AIR
 CHAMBERS ARE NOT APPROVED. DELETE FROM
 NOTES. SECTION 604.9
 10) SHT P-9 SEPARATE GAS PERMIT REQUIRED
 FOLLOWING INFORMATION REQUIRED FOR THE
 PERMIT:
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2001
 FUEL GAS CODE.
 B. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED AND ALL PIPE SIZES. (RECOMMEND
 THAT A 2 POUND SYSTEM BE USED AS THIS
 WILL REDUCE THE PIPE SIZE)
 C. SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER FBC-2001 FUEL
 GAS CODE SECTION 304.
 D. SUBMIT A DETAIL SHOWING THE TYPE,
 LOCATION, SIZE AND TERMINATION OF THE
 GAS VENTS PER FBC-2001 FUEL GAS CODE
 SECS. 502 THRU 506.
 E. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2001 FUEL GAS CODE SEC 402.2
 11) SEPARATE IRRIGATION PLANS AND PERMIT
 ARE REQUIRED.
 12) SHT P-10 ROOF DRAIN AND SQUARE FOOT-
 AGE NOT SHOWN FOR ROOF BELOW AT ENTRANCE
 13) SHT P-11 IDENTIFY FIXTURES ON SANT.
 RISER S/15.
 14) SHT P-11 FLOOR DRAINS NOT APPROVED
 FOR INDIRECT WASTE. SECTIONS 802.3 AND
 802.3.2
 15) SHT P-11 FIXTURE UNITS ARE NOT CORR-
 ECT FOR SANT. RISERS S/5 THRU S-14. THE
 WATER CLOSETS ARE 4DFU NOT 3DFU. ADJUST
 FIXTURE UNITS ON RISERS, AND FIXTURE
 UNITS ACCUMULATED IN BLDG DRAIN ON SHT
 P-12. 6" PIPE REQUIRED @ 186 FU WHERE IT
 SHOWS 4" @ 159 FU.
 16) SHT P-13 DOMESTIC WATER RISER, AIR
 CHAMBERS ARE NOT APPROVED. DELETE FROM
 RISER DIAGRAM. SECTION 604.9 - WATER
 HAMMER ARRESTORS ARE REQUIRED AT ALL
 QUICK CLOSING VALVES, (WASH MACHINES,
 ICE MAKERS, AND DISH WASHERS), & LOCATED
 NEAR THE FIXTURE IN AN "EFFECTIVE RANGE"
 NOT IN THE CEILING. PDI-WH 201 AND MANUF
 INSTALLATION INSTRUCTIONS.
 17) SHT P-14 VACUUM RELIEF VALVES REQUI-
 RED FOR BOTTOM FED WATER HEATERS. SECT-
 ION 504.2
 18) SHT P-14 ISOMETRIC WATER DIAGRAM,
 AIR CHAMBERS AT POOL SHOWER NOT APPROVED
 DELETE. 604.9
 19) SHT P-15 DOMESTIC WATER ISOMETRIC
 DIAGRAMS, AIR CHAMBERS ARE NOT APPROVED.
 DELETE FROM RISERS.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 5 Status P Date 2004-11-09 Cont ID  
Sent By mmclean Date 2004-11-09 Time 17:01 Rev Time 0.00
Received By mmclean Date 2004-11-09 Time 17:01 Sent To  
Notes
2004-11-09 00:00:00PROVISO -
  
 1) INSTALL 6 (2 GROUPS OF 3) SABEL PALMS
 ALONG AUSTRALIAN AVENUE AS REQUIRED BY
 CENTREPARK WEST UNIFIED STREETSCAPE PLAN
 (1999).
  
 2) INSTALL 2 ROYAL PALMS AT PEDESTRIAN
 CONNECTION AS REQUIRED BY CENTREPARK
 WEST UNIFIED STREETSCAPE PLAN (1999).

Review Stop Z ZONING
Rev No 4 Status F Date 2004-10-20 Cont ID  
Sent By sgraham Date 2004-10-20 Time 16:04 Rev Time 0.00
Received By mmclean Date 2004-11-09 Time 16:59 Sent To  
Notes
2004-10-20 00:00:001. NEED MINOR AMENDMENT TO THE PD
 2. PALMS NEED TO BE PROVIDED ON
 AUSTRIALIAN AVE AS REQUIRED BY
 AUSTRALIAN AVE STREETSCAPE PLAN.
 CALL JOHN ROACH AT 822-1435
 CALLED CONT 10-20-04

Review Stop Z ZONING
Rev No 3 Status P Date 2004-03-30 Cont ID  
Sent By csiegber Date 2004-06-11 Time 09:06 Rev Time 0.00
Received By jroach Date 2004-03-30 Time 11:00 Sent To  
Notes
2004-03-30 00:00:003/30/2004 - REVISED SITE PLAN SUBMITTED
 FOLLOWING APPROVAL ON 3/24/2004.
 REVISED PLAN OK.JOHN ROACH, PLANNER -
 659.8031

Review Stop Z ZONING
Rev No 2 Status P Date 2004-03-30 Cont ID  
Sent By jroach Date 2004-03-23 Time 14:28 Rev Time 0.00
Received By jroach Date 2004-03-23 Time 14:28 Sent To  
Notes
2004-03-23 00:00:003/23/2004 - RECORDED UNITY OF TITLE AND
 EASEMENT TERMINATION AGREEMENT SUBMITTED
 AND ADDED TO PERMIT PACKAGE.PLANS
 PASSED SUBJECT TO APPROVAL OF REVISIONS
 OF LANDSCAPE PLAN TO ACCOMMODATE
 ADDITION OF POOL EQUIPMENT.JOHN
 ROACH, PLANNER - 659.8031

Review Stop Z ZONING
Rev No 1 Status F Date 2004-01-16 Cont ID  
Sent By csiegber Date 2004-01-15 Time 16:55 Rev Time 0.00
Received By mmclean Date 2004-01-16 Time 10:28 Sent To I
Notes
2004-01-16 00:00:00DENIED, WAITING ON SIGNED TERMINATION
 AGREEMENT & THE UNITY OF TITLE NEEDS TO
 BE RECORDED FOR LOTS 1,2 AND A PORTION
 OF 7 PER JOHN ROACH PLANNER 659-8031 MM