| Plan Review Stops For Permit 04010577 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-03-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-03-03 |
Time |
14:37 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2004-03-03 |
Time |
14:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-02-05 |
Time |
08:13 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2004-02-05 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2004-02-05 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04010577 | | | ADD: 1801 N FLAGLER# 219 | | | CONT: GC WORKS | | | TEL: (305)861-2918 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PLANS ARE TO BE SIGNED WITH A FULL | | | SIGNATURE FROM THE ARCHETECT OF RECORD | | | PER 481.221 WITH A MINIMUM OF FIRST AND | | | LAST NAME AS SHOWN ON THE ARCHITECTS' | | | LICENSE, FAC 61G1-16.003 | | | | | | 2) HI-RISE TYPE II BUILDING, 609.2.1. | | | ALL BACKING TO BE FIRE RETARDANT WOOD | | | OR NON-COMBUSTIBLE. | | | | | | 3)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 4) 104.2.1.3 THE BUILDING OFFICIAL | | | MAY SET STANDARDS THROUGH DEPARTMENTAL | | | POLICY STANDARDS FOR PLANS AND SPRCIFICA | | | TIONS. "NO WHITE OUT". | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-02-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-02-25 |
Time |
06:37 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-02-25 |
Time |
06:37 |
Sent To |
|
|
| Notes |
| 2004-02-25 00:00:00 | ********* PROVSIO ***** | | | | | | 1)NOTE: PLEASE SEE 220.16, LOAD FOR | | | LAUNDRY CIRCUIT STILL NOT SHOWN AS REQ'D | | | 1500VA. | | | | | | 2)NOTE: PLEASE CORRELATE FEEDER CONDUCT- | | | -OR SIZES. ONE NOTE MENTIONS, 1/0'S | | | OTHER MENTIONS #1'S. | | | | | | PLEASE SUBMIT THE ABOVE AS A REVISION | | | BEFORE ANY ROUGH ELECTRICAL INSPECTION | | | IS CALLED IN. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-14 |
Time |
13:28 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-01-14 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2004-01-14 00:00:00 | *********** UNSAT ****************** | | | | | | 1)NOTE: PLEASE HAVE PLANS "SIGNED" BY | | | THE ARCH OF RECORD AS SHOWN ON LICENSE. | | | PLEASE NOTE, SIGNATURE MUST CONTAIN A | | | MIN OF FIRST AND LAST NAME. | | | FS 481.025 | | | WE HAVE BEEN INFORMED, INITIALS ARE | | | NOT ACCEPTABLE. | | | | | | 2)NOTE: PLEASE SEE PLANS, SHOWS NEW | | | PANEL B2, HOWEVER, PANEL SCHEDULE SHOWS | | | EXST? PLEASE CLARIFY THIS. | | | | | | 3)NOTE: PLEASE SEE 220.16B FOR MIN LOAD | | | FOR LAUNDRY. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | REVIEW. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-02-25 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-02-25 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-02-25 |
Time |
13:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2004-01-20 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-20 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-20 |
Time |
13:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-08-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-16 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-16 |
Time |
14:56 |
Sent To |
M |
|
| Notes |
| 2004-08-16 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-03-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-11 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-11 |
Time |
16:02 |
Sent To |
P |
|
| Notes |
| 2004-03-11 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-02-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-18 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-18 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2004-02-18 00:00:00 | TO COMM BD#8 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-02-05 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2004-01-13 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2004-01-13 00:00:00 | TO COMM BD#28 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-08-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-27 |
Time |
06:30 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-08-27 |
Time |
06:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-16 |
Time |
14:56 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-03-22 |
Time |
06:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-02-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-19 |
Time |
10:07 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-02-25 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2004-02-25 00:00:00 | PROVISO: | | | AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 FBC(M) | | | 307.2.3.PLEASE PROVIDE SEPARATE PAN | | | FOR THE AHU. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-01-30 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-30 |
Time |
06:55 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2004-01-30 |
Time |
06:54 |
Sent To |
|
|
| Notes |
| 2004-01-30 00:00:00 | PROVISO: | | | 1.CONDENSING UNIT STAND SHALL COMPLY | | | WITH 2001 FBC 1511.7, SEE THE SCHEDULE | | | BELOW FOR PROPER HEIGHT REQUIREMENT. | | | | | | 2.AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQURIED PER 2001 FBC(M) | | | 307.2.3.A SEPARATE DRAIN IS REUQIRED F | | | ROM THE AUXILIARY DRAIN PAN TERMINATING | | | AT CONSPICUOUS POINT TO SERVE AS AN | | | ALARM THEAT THE PRIMARY DRAIN IS | | | RESTRICTED.A FLOAT SWITCH MAY BE USED | | | IN LIEU OF SEPARATE DRAIN. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-03-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-19 |
Time |
10:07 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-03-19 |
Time |
10:07 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-03-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-11 |
Time |
16:02 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-03-02 |
Time |
18:19 |
Sent To |
|
|
| Notes |
| 2004-03-02 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | CAST IRON SOVENT DESIGN MAN. | | | NUMBER 802 | | | | | | 1) WATER HAMMER ARRESTORS LOCATED AT | | | KITCHEN SINK SHALL BE LOCATED NEAR THE | | | FIXTURES IN AN "EFFECTIVE RANGE" NOT IN | | | THE CEILING AS SHOWN. | | | | | | 2) SHT P-2 SANITARY RISER DIAGRAM FOR | | | THE BATHROOM GROUPS. SOVENT DESIGN CALLS | | | FOR A PRL LINE TO CONNECT TO THE VERTIC- | | | AL PORTION OF THE STACK DOWNSTREAM OF | | | THE OFFSET. A DE-AERATOR FITTING WILL BE | | | REQUIRED AS SHOWN IN ATTACHED SHEET WITH | | | PRL LINE TIED INTO IT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-01-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-23 |
Time |
17:59 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-01-23 |
Time |
17:54 |
Sent To |
|
|
| Notes |
| 2004-01-23 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMIN. CODE | | | FLORIDA STATUTES | | | | | | 1) PLANS TO BE SIGNED WITH A FULL SIG- | | | NATURE FROM THE ARCH. PER FS 481.221 | | | WITH A MINIMUM OF FIRST AND LAST NAME AS | | | SHOWN ON ARCH. LICENSE. FAC 61G1-16.003. | | | 2) SHT P-1 WATER HEATER DETAIL: | | | A) THERMAL EXPANSION CONTROL REQUIRED | | | PER SECTION 607.3.2. | | | B) DIELECTRIC UNIONS ARE NOT APPROVED | | | FOR WATER PIPING. DELETE FROM DETAIL. | | | 3) SHT P-2 WATER RISER DIAGRAM: WATER | | | HAMMER ARRESTORS SHALL BE LOCATED NEAR | | | THE FIXTURE IN AN "EFFECTIVE RANGE" NOT | | | IN THE CEILING AS SHOWN. PDI-WH 201 AND | | | MANUF. INSTALLATION INSTRUCTIONS. 604.9 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|