| Plan Review Stops For Permit 04010573 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-03-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-03-03 |
Time |
13:26 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2004-03-03 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-02-05 |
Time |
09:43 |
Rev Time |
1.10 |
| Received By |
jwitmer |
Date |
2004-02-05 |
Time |
09:37 |
Sent To |
PC |
|
| Notes |
| 2004-02-05 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04010573 | | | ADD: 1803 N FLAGLER DR# 103 | | | CONT: CG WORKS | | | TEL: (305) 861-2918 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1) PLANS ARE TO BE SIGNED WITH A FULL | | | SIGNATURE FROM THE ARCHETECT OF RECORD | | | PER 481.221 WITH A MINIMUM OF FIRST AND | | | LAST NAME AS SHOWN ON THE ARCHITECTS' | | | LICENSE, FAC 61G1-16.003 | | | | | | 2) 104.2.1.3 THE BUILDING OFFICIAL | | | MAY SET STANDARDS THROUGH DEPARTMENTAL | | | POLICY STANDARDS FOR PLANS AND SPRCIFICA | | | TIONS. "NO WHITE OUT". | | | | | | 3)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-03 |
Time |
19:57 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-08-03 |
Time |
19:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-07-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-30 |
Time |
07:59 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-07-12 |
Time |
19:03 |
Sent To |
|
|
| Notes |
| 2004-07-12 00:00:00 | ********** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE NOTES FROM PREVIOUS | | | PROVISO. | | | | | | PLEASE SEE LOAD CALCULATIONS MENTIONS | | | 208V'S YET PANEL INDICATES 240V'S | | | PLEASE SEE 220.16 FOR MIN WASHER LOAD. | | | | | | 2)NOTE: PLEASE SEE PLANS NOTE SIGNED | | | DATED AND SEALED BY ARCH. | | | FS 481.221, FAC 61G1-16 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-03-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-03-03 |
Time |
15:33 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-03-03 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2004-03-03 00:00:00 | *** REDLINED ** | | | | | | CORRELATE VOLTAGE | | | LOAD FOR WASHER/LAUNDRY PER 220.16B | | | 1500VA |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-14 |
Time |
08:53 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-01-14 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2004-01-14 00:00:00 | ************** UNSAT ************ | | | | | | 1)NOTE: PERMIT APPLICATION WAS SUBITTED | | | WITH THE ADDRESS IF 1803 N FLAGLER, | | | COMES UP IN COMPUTER FOR THAT PCN AS | | | 1801. PLEASE ADJUST. | | | | | | 2)NOTE: PLEASE CORRELATE PLANS AND PANEL | | | SCHEDULES. PLEASE SEE THAT THERE ARE | | | MANY ITEMS THAT ARE BEING REMOVED. | | | PLEASE ALSO ADJUST LOAD CALCUALTIONS. | | | | | | 3 )NOTE: PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CURCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED , | | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | 2002 NEC 210.12 | | | | | | 4)NOTE: PLEASE SIGN PLANS WITH LEGAL | | | SIGNATURE. APPEARS TO BE INITIALS. | | | WE HAVE BEEN GIVEN NOTICE THAT PLANS | | | MUST CONTAIN COMPLETE SIGNATURE AS ON | | | LICENSE. FS 481.221 AND FAC 61G1-16 | | | | | | 5)NOTE: PLEASE SEE BOTH PANELS LABELED | | | AS "A-2". | | | | | | 6)NOTE: PLEASE SEE 220.16B FOR MIN | | | LAUNDRY LOAD. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-03-04 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-03-04 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-03-04 |
Time |
10:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2004-01-20 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-20 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-20 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2004-01-20 00:00:00 | 1) SMOKE DETECTORS REQUIRED INSIDE AND | | | OUTSIDE OF SLEEPING ROOMS. | | | | | | 2) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE SPRINKLER REMODEL. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-07-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-30 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-30 |
Time |
07:59 |
Sent To |
E |
|
| Notes |
| 2004-07-30 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-07-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-09 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-09 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2004-07-09 00:00:00 | TO COMM BD#22 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-02-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-25 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-25 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2004-02-25 00:00:00 | TO COMM BD#62 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-02-05 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2004-01-13 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2004-01-13 00:00:00 | TO COMM BD#23 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-29 |
Time |
17:05 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2004-01-29 |
Time |
16:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-07-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-28 |
Time |
11:59 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-07-28 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2004-07-28 00:00:00 | REVISION OK - DID NOT DELETE W/HEATER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-03-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-06 |
Time |
06:25 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-03-06 |
Time |
06:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-01-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-23 |
Time |
17:34 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-01-23 |
Time |
17:34 |
Sent To |
|
|
| Notes |
| 2004-01-23 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | FLORIDA ADMIN. CODE | | | FLORIDA STATUTES | | | | | | 1) PLANS TO BE SIGNED WITH A FULL SIG- | | | NATURE FROM THE ARCH. PER FS 481.221 | | | WITH A MINIMUM OF FIRST AND LAST NAME AS | | | SHOWN ON ARCH. LICENSE. FAC 61G1-16.003. | | | 2) PER SECTION 104.3.1.1 A SANITARY | | | RISER DIAGRAM AND A WATER RISER DIAGRAM | | | ARE REQUIRED. | | | 3) SOVENT SYSTEM IS AN ENGINEERED SYSTEM | | | AND AS SUCH, EXISTING SYSTEM SHALL HAVE | | | TO BE REVIEWED TO SEE IF CHANGES CAN BE | | | APPROVED. | | | 4) ALL CAPPED PLUMBING LINES SHALL BE | | | INSPECTED PRIOR TO COVERING. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|