Plan Review Details - Permit 04010566
Plan Review Stops For Permit 04010566
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-02-10 Cont ID  
Sent By pkrauss Date 2004-01-29 Time 17:47 Rev Time 2.00
Received By alange Date 2004-02-10 Time 13:05 Sent To  
Notes
2004-02-10 00:00:00DENIED
 1.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 2.FBC3401.7.2.6 PROJECT VALUE OVER
 50%OF THE IMPROVED VALUE OF THE
 BUILDING.
 EXISTING STRUCTURE TO COMPLY WITH THIS
 SECTION OF THER CODE
 3.FBC 1006.2.2 AND 1006.2.4 EXTERIOR
 STAIRS SHALL COMPLY WITH THIS SECTION OF
 THE CODE. 1 HOUR SEPERATION REQUIRED
 ON THIS WALL INCLUDING ALL PENATRATIONS
 WITHIN 10 FT AS MENTIONED IN THE CODE.
 4.FBC 1608.2.2 GAURDRAILS SHALL COMPLY
 WITH THIS SECTION AND HAVE A 200LB.
 CONCENTRATED LOAD.
 5. CHECK SIZE AND DEPTH OF EXISTING
 FOOTING AND VERIFY THEY WILL MEET THE
 ADDITIONAL LOAD.SHOW DETAIL.
 6.NO PRODUCT APPROVALS SUBMITTED.
 SUBMIT 2 COPIES OF PRODUCT APPROVALS.
 7.SHOW SIZE AND TYPE OF DRYWALL USED
 ON GARAGE CEILING.
 8.WINDOW BUCK DETAIL (11) SHOULD
 COMPLY WITH 1707.4.4.2 BUCK SHALL EXTEND
 BEYOND THE INTERIOR FACE OF THE WINDOW
 OR DOOR FRAME.TO PROVIDE FULL SUPPORT
 OF THE FRAME.
 9.SHOW STAIRS ON SITE PLAN.
 10.VERIFY MEAN ROOF HEIGHT.SHOWN AS
 30FT.
  
 ANY QUESTIONS CALL
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-01-28 Cont ID  
Sent By csiegber Date 2004-01-27 Time 08:50 Rev Time 0.50
Received By btrobaug Date 2004-01-28 Time 16:18 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-01-27 Cont ID  
Sent By csiegber Date 2004-01-27 Time 08:50 Rev Time 0.00
Received By csiegber Date 2004-01-27 Time 08:50 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-01-12 Cont ID  
Sent By mmclean Date 2004-01-23 Time 11:55 Rev Time 0.00
Received By csiegber Date 2004-01-12 Time 15:40 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2004-01-29 Cont ID  
Sent By kstevens Date 2004-01-29 Time 08:03 Rev Time 0.33
Received By pkrauss Date 2004-01-29 Time 17:36 Sent To B
Notes
2004-01-29 00:00:00MECHANICAL PERMIT REQUIRED -
 NO MECHANICAL PLANS SUBMITTED FOR REVIEW
 A/C EQUIPMENT INDICATED ON PLAN SHEET 1
 AND ENERGY CALCULATIONS SUBMITTED.
 REFERENCE NOTE A/C EQUIPMENT ON
 PREFORMED CURB.CURBS SHALL COMPLY WITH
 2001 FBC 1511.7, SEE ATTACHED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-01-29 Cont ID  
Sent By btrobaug Date 2004-01-28 Time 17:24 Rev Time 0.50
Received By kstevens Date 2004-01-29 Time 08:02 Sent To M
Notes
2004-01-29 00:00:00PASSED/PROVISO - AIR CHAMBERS NOT APPROV
 ED - WATER HAMMER ARRESTORS REQUIRED AT
 WASH MACHINE - VENT REQUIRED FOR FIRST
 FLOOR SHOWER.

Review Stop Z ZONING
Rev No 2 Status N Date 2004-01-23 Cont ID  
Sent By mmclean Date 2004-01-23 Time 11:55 Rev Time 0.00
Received By mmclean Date 2004-01-23 Time 11:55 Sent To I
Notes
2004-01-23 00:00:00CUSTOMER APPLYING FOR VARIANCE FOR REAR
 & SIDE SETBACK.

Review Stop Z ZONING
Rev No 1 Status F Date 2004-01-14 Cont ID  
Sent By csiegber Date 2004-01-12 Time 15:40 Rev Time 0.00
Received By mmclean Date 2004-01-14 Time 14:22 Sent To  
Notes
2004-01-14 00:00:00DENIED, NO OUTSIDE ACCESS, NEED TO APPLY
 FOR A VARIANCE TO MEET THE REAR SETBACK
 OF 10% LOT DEPT CALLED CONTR FILE C MM