| Plan Review Stops For Permit 04010540 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-04-26 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2004-04-26 |
Time |
17:16 |
Rev Time |
3.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-04-26 00:00:00 | | | | BUILDING REVIEW COMMENTS | | | -------- ------ -------- | | | | | | 1] | | | ALL PRODUCT APPROVAL SHALL BE LISTED ON | | | FLORIDA'S D.C.A WEBSITE. MISSING | | | REPORTS INCLUDE, SKYLIGHT, OVERHEAD | | | DOOR, AND METAL ROOF. | | | | | | 2] | | | FIRE SPRINKLER LAYOUT IS REQUIRED AT | | | TIME OF PERMIT. | | | | | | 3] | | | COUNTY IMPACT FEE PAYMENT IS REQUIRED | | | PRIOR TO PERMIT ISSUE. | | | | | | | | | | | | | | | LUIS MARTINEZ | | | 561-805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2004-03-09 |
Time |
17:32 |
Rev Time |
12.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-03-09 00:00:00 | | | | BUILDING REVIEW COMMENTS | | | -------- ------ -------- | | | | | | 1] | | | PROVIDE SOILS INVESTIGATION REPORT, 2 | | | COPIES SIGNED AND SEALED. | | | | | | 2] | | | SUBMIT ALL PRODUCT APPROVAL REPORTS FOR | | | EXTERIOR WINDOWS, DOORS, GLAZING, ROOF | | | AND WALL COVERINGS. | | | | | | 3] | | | PROVIDE SIGNED AND SEALED FIRE | | | SPRINKLER DESIGN AND LAYOUT ACCORDING | | | TO: FBC 104.3.1.1#5 | | | | | | 4] | | | SHEET 10.1 WINDOW SCH.-WN1 REFERENCES | | | 110MPH WIND SPEED. FBC REQUIRES DESIGN | | | TO 140MPH. | | | | | | 5] | | | CHECK DOOR SCH. #122 AND #202 SHALL BE | | | 3/4HR RATED PER FBC 1006.2.2 | | | | | | 6] | | | SHEET S-6,NOTES ACI 318-94 SHALL BE | | | ACI 318-02 PER FBC CHAPTER 35. | | | SHEET S-6 SHALL BE SIGNED AND DATED BY | | | ENGINEER. | | | | | | | | | | | | | | | | | | LUIS MARTINEZ | | | 561-805-6710 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-04-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-15 |
Time |
17:35 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-04-15 |
Time |
17:09 |
Sent To |
|
|
| Notes |
| 2004-04-15 00:00:00 | REDLINED, NO EQUIPMENT GROUNDING | | | CONDUCTOR FROM METER TO FIRST MEANS | | | OF DISC. 250.24 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-22 |
Time |
16:43 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2004-01-22 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2004-01-22 00:00:00 | ************ UNSAT *********** | | | | | | ** PLANS ONLY IN FOR PLAN REVIEW AND NOT | | | FOR PERMIT*** | | | | | | 1)NOTE: PLEASE PROVIDE A BRIEF LOAD | | | SUMMARY FOR W/SQ FT KVA LOAD FOR A/C | | | SYSTEMS. PER 220CALL FOR INFO. | | | | | | 2)NOTE: PLEASE SHOW/CLARIFY NEW REQ'D | | | SIGN CIRCUIT PER 600.5 | | | | | | 3)NOTE: PLEASE CLARIFY LOCATION OF GFI | | | RECEPT FOR COND UNITS. PER 210.63 | | | ROOF TOP ALSO. | | | | | | 4)NOTE: PLEASE CLARIFY/ SHOW METHOD | | | OF EQUIPMENT GROUNDING FOR ALL FEEDERS/ | | | CONDUITS ON RISER DIAGRAM. 250.110, | | | 250.24 ETC. SIZE PER 250.122 | | | | | | 5)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | MAIN NOT SHOWN. NOTED FOR PANELS. | | | | | | 6)NOTE: PLEASE SEE FIRE REVIEW COMMENTS, | | | AND COMMENTS FROM OTHER REVIEWERS AS | | | THEY MAY OR MAY NOT HAVE AN AFFECT ON | | | ELECTRICAL PLANS. | | | | | | 7)NOTE: PLEASE REMOVE ALL OLD/ VOIDED | | | SHEETS AND INSERT NEW SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | SOME REVIEWERS REQUIRE ONE SET OF OLD | | | SHEETS FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2004-04-13 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-04-13 |
Time |
09:32 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2004-04-13 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-01-22 |
Time |
10:20 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-01-22 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2004-01-22 00:00:00 | FAILED: | | | 1. PLEASE SUBMIT CIVIL PLANS ONLY TO | | | THE PUBLIC UTILITIES AND ENGINEERING | | | SERVICES, ATT; JIM SPEACH 659-8040 EXT. | | | 2317 FOR THIER REVIEW AND APPROVAL OF | | | CONNECTIONS, BACKFLOWS AND METERS | | | LOCATION. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-04-01 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-04-01 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-04-01 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-16 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-16 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2004-01-16 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED | | | PRIOR TO, DURING AND AFTER | | | CONSTRUCTION. | | | | | | 2) A KNOX-BOX WILL BE REQUIRED. | | | | | | 3) PLEASE ILLUSTRATE ON PLANS ALL | | | EMERGENCY LIGHT FIXTURE LOCATIONS | | | FOR SECOND FLOOR. | | | | | | 4) FIRE WATER LINES SHOULD BE LOOPED | | | WHENEVER POSSIBLE. IT APPEARS THAT | | | THE 6" WATER MAIN ON SITE FOR THIS | | | PROJECT DEAD-ENDS NEAR THE WAREHOUSE. | | | | | | 5) PLEASE EXPLAIN WHY STAIR # 201 DOES | | | NOT HAVE A DOOR AT THE TOP OR BOTTOM | | | AND WHY IS IT OPEN TO THE SECOND FLOOR. | | | | | | 6) PLEASE INDICATE INTERIOR FINISH | | | FOR WALLS AND CEILINGS. | | | | | | 7) NO FIRE SPRINKLER PLANS PROVIDED. | | | | | | 8) IT WAS ALSO NOTED THAT FUTURE | | | EXPANSIONS ARE PLANNED, IS THE | | | PLANNED WATER FIRE LINE GOING TO BE | | | BIG ENOUGH. | | | | | | 9) PLEASE PROVIDE MORE DETAILS ON 3/4 | | | HOUR RATED OPENING PROTECTIVES ON | | | SOUTH ELEVATION. | | | | | | 10) TACTILE SIGNAGE REQUIRED AT STAIR | | | LOCATIONS. | | | | | | 11) ELEVATOR WARNING SIGNS REQUIRED | | | AT ELEVATOR. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-03-31 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-03-31 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-03-31 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2004-03-31 00:00:00 | TO COMM. BD "6 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-15 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-13 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2004-01-16 00:00:00 | TO COMM BD#18 | | 2004-01-13 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-04-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-08 |
Time |
08:24 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-04-08 |
Time |
07:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-29 |
Time |
12:25 |
Rev Time |
1.25 |
| Received By |
pkrauss |
Date |
2004-01-29 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2004-01-29 00:00:00 | DENIED: | | | 1.PROVIDE OUTSIDE AIR CALCULATIONS PER | | | 2001 FBC(M) 403.3. | | | | | | 2.PLEASE INDICATE WHAT THE WAREHOUSE | | | WILL BE USED FOR.PROVIDE INFORMATION | | | ON ANY CHEMICALS OR COMBUSTIBLES THAT | | | MAY BE STORED. | | | | | | 3.PLANS DO NOT INDICATE VENTILATION | | | FOR THE WAREHOUSE AREA.SHOW COMPLIANCE | | | WITH 2001 FBC(M) TABLE 403.3 FOR | | | MINIMUM VENTILATION REQUIREMENTS. | | | | | | 4.DUCT SMOKE DETECTORS REQUIRED IN THE | | | SUPPLY DUCT OF SYSTEMS WITH THE DESIGN | | | CAPACITY GREATER THAN 2,000 CFM. | | | PLEASE INDICATE DUCT SMOKE DETECTORS ON | | | THE PLAN. | | | | | | 5.PLEASE INDICATE CONDENSATE FOR THE | | | ROOF TOP UNITS THAT SERVE THE SECOND | | | FLOOR. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-04-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-05 |
Time |
15:32 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2004-04-05 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2004-04-05 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 BUILDING | | | | | | A) COMMENTS FROM PREVIOUS REVIEW. NUMBER | | | TO STAY THE SAME TO AVOID CONFUSION. | | | 3) SHTS ME4 & ME6 PLUMBING PLAN FIRST | | | FLOOR AND SANT. RISER DIAGRAM. WATER | | | CLOSET P-2 IN MEN'S ROOM NOT VENTED. | | | SECTION 901.2.1. - RESPONSE NOTED, BUT | | | THE P-2 W/C VENTED WAS IN THE WOMENS | | | TOILET ROOM. P-2 IN MEN'S TOILET ROOM IS | | | DOWNSTREAM OF THE SANITARY LINE FROM THE | | | 2ND FLOOR AND HAS NO VENT TO DRAW FROM. | | | 8) EMERGENCY OVERFLOW DRAINS HAVE BEEN | | | DELETED AND OVERFLOW SCUPPERS ARE SHOWN. | | | PROVIDE A DETAIL OF THE OVERFLOW SCUPPER | | | (TYPICAL) AND SHOW HEIGHT & WIDTH. MIN. | | | 38 SF REQUIRED. SHOW COMPLIANCE WITH | | | SECTION 1511.6.4.3 (BUILDING) & SECTION | | | 1107.3 (PLUMBING) | | | *****NEW COMMENT*** | | | 1B) SHT ME6 WATER HEATER DETAIL - P/T | | | RELIEF VALVE DISCHARGE LINE SHALL NOT | | | HAVE ANY TRAPPED SECTIONS, AND SHALL | | | HAVE A VISIBLE AIR GAP OR AIR GAP FITT- | | | ING LOCATED IN THE SAME ROOM AS THE | | | WATER HEATER. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-01-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-21 |
Time |
10:02 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-01-20 |
Time |
18:50 |
Sent To |
|
|
| Notes |
| 2004-01-21 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1) SUBMIT DETAIL FOR DRINKING FOUNTAIN | | | PER SECTION 11-4.15 AND ALL SUBSECTIONS. | | | 2) SUBMIT DETAIL FOR BREAK ROOM SINK PER | | | SECTION 11-4.24 AND ALL SUBSECTIONS. | | | 3) SHTS ME4 & ME6 PLUMBING PLAN FIRST | | | FLOOR AND SANT. RISER DIAGRAM, WATER | | | CLOSET P-2 IN MEN'S ROOM NOT VENTED. | | | SECTION 901.2.1 | | | 4) SHT ME4 WATER HEATER UNDER SINK SHALL | | | BE ACCESSIBLE. SUBMIT A DETAIL. SECTION | | | 501.4 | | | 5) SHT ME6 AN RPZ BACKFLOW IS REQUIRED | | | ON WATER SERVICE. SECTION 608.13.2 | | | 6) SHT ME6 WATER ISOMETRIC, SHOW WATER | | | HEATER PAN DRAIN LINE FOR W/H IN BATH- | | | ROOM. SECTIONS 504.8.1 & 504.8.2. | | | 7) SUBMIT A STORM RISER DIAGRAM SHOWING | | | PIPE SIZES AND TERMINATION ECT. SECTION | | | 104.3.1.1 | | | 8) SHT 7.1 CLAIRFY 5" ERD"S. | | | 9) SUBMIT CALCULATIONS FOR PRIMARY ROOF | | | DRAINS. INDICATE SQUARE FOOTAGE OF ROOF | | | AND 1/2 AREA OF ALL VERTICAL WALLS IN- | | | CLUDING PARAPETS IN CALCULATIONS. SECT- | | | IONS 1106 & 1107 AND ALL SUBSECTIONS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-01-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-15 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-01-15 |
Time |
16:00 |
Sent To |
I |
|
| Notes |
| 2004-01-15 00:00:00 | OK PER JOSH LONG PLANNER 659-8031 MM |
|
|