Plan Review Details - Permit 04010519
Plan Review Stops For Permit 04010519
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-03-24 Cont ID  
Sent By alange Date 2004-03-24 Time 11:33 Rev Time 0.75
Received By alange Date 2004-03-24 Time 11:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-03-16 Cont ID  
Sent By csiegber Date 2004-03-23 Time 14:23 Rev Time 1.25
Received By alange Date 2004-03-16 Time 08:44 Sent To  
Notes
2004-03-16 00:00:00DENIED
  
 1. THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSEAND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2.CITY AMMENDMENT TO THE FBC 104.6.5
 BUILDING PERMIT VALUATION TO LOW.
 ADJUSTED TO $8000.00.ADDITIONAL PERMIT
 FEES OF $161.60 DUE.
  
 3.PRODUCT APPROVAL FOR EXTERIOR DOOR
 MISSING.SUBMIT 2 COPIES.
  
 4.IDENTIFY METHOD OF REINFORCEMENT
 ON NEW DRIVEWAY.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-02-10 Cont ID  
Sent By pkrauss Date 2004-01-29 Time 07:12 Rev Time 1.75
Received By alange Date 2004-02-10 Time 07:51 Sent To  
Notes
2004-02-10 00:00:001.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 2. THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSEAND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
 3.CITY AMMENDMENT TO THE FBC 104.6.5
 BUILDING PERMIT VALUATION ADJUST
 VALUATION OF PROJECT UP TO AT LEAST
 $8000.MINIMUM.
 4.CITY AMMENDMENTS TO THE FBC 1804.1.7
 FINISH FLOOR ELEVATION NOT SHOWN.
 REQUIRED TO BE AT LEAST 4" ABOVE GRADE.
 5.PRODUCT APPROVAL REQUIRED FOR
 EXTERIOR DOOR.
 6.SHUTTERS REQUIRED OVER NEW WINDOWS.
 SUBMIT PRODUCT APPROVAL FOR IMPACT
 PROTECTION OR OBTAIN A SEPARATE PERMIT.
 7.SHOW FOOTING DETAIL FOR NEW LIVING
 SPACE.
 8.SUBMIT SIGNED AND SEALED ENGINEERING
 DETAIL OF ATTACHMENT METHOD FROM TOP
 PLATE OF NEW WALL TO ROOF.
 9.IDENTIFY ROOM ON THE OPPOSITE SIDE
 OF DOOR FROM NEW LIVING SPACE.
 10.IDENTIFY METHOD OF REINFORCEMENT
 FOR NEW DRIVEWAY.
 11.ALL INFORMATION, DRAWINGS, SPECIF-
 ICATIONS AND ACCOMPANYING DATA SHALL
 BEAR THE NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN.
 CITY AMENDMENTS 104.2.1
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-01-23 Cont ID  
Sent By csiegber Date 2004-01-23 Time 08:24 Rev Time 0.00
Received By btrobaug Date 2004-01-23 Time 12:15 Sent To P
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2004-03-24 Cont ID  
Sent By csiegber Date 2004-03-12 Time 11:21 Rev Time 0.00
Received By alange Date 2004-03-24 Time 10:20 Sent To  
Notes
2004-03-24 00:00:00PASSED WITH PROVISO PER MO AMINI

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-03-23 Cont ID  
Sent By csiegber Date 2004-03-23 Time 14:23 Rev Time 0.00
Received By csiegber Date 2004-03-23 Time 14:23 Sent To B
Notes
2004-03-23 00:00:00TO AL DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-03-12 Cont ID  
Sent By csiegber Date 2004-03-12 Time 11:21 Rev Time 0.00
Received By csiegber Date 2004-03-12 Time 11:21 Sent To ENG
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-01-23 Cont ID  
Sent By csiegber Date 2004-01-23 Time 08:24 Rev Time 0.00
Received By csiegber Date 2004-01-23 Time 08:24 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-01-20 Cont ID  
Sent By mmclean Date 2004-01-22 Time 10:00 Rev Time 0.00
Received By csiegber Date 2004-01-20 Time 11:17 Sent To Z
Notes
2004-01-20 00:00:00TO Z/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-01-12 Cont ID  
Sent By csiegber Date 2004-01-12 Time 10:57 Rev Time 0.00
Received By csiegber Date 2004-01-12 Time 10:57 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2004-01-29 Cont ID  
Sent By kstevens Date 2004-01-26 Time 09:28 Rev Time 0.10
Received By pkrauss Date 2004-01-29 Time 07:11 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2004-01-26 Cont ID  
Sent By btrobaug Date 2004-01-23 Time 14:56 Rev Time 0.25
Received By kstevens Date 2004-01-26 Time 09:27 Sent To M
Notes
2004-01-26 00:00:00NO PLUMBING PLANS SUBMITTED

Review Stop Z ZONING
Rev No 2 Status P Date 2004-01-22 Cont ID  
Sent By mmclean Date 2004-01-22 Time 09:57 Rev Time 0.00
Received By mmclean Date 2004-01-22 Time 09:57 Sent To I
Notes
2004-01-22 00:00:00NEED TO PAY ADDT'L FEE FOR APPROACH
 CALLED OWNER LEFT MSG MM

Review Stop Z ZONING
Rev No 1 Status F Date 2004-01-12 Cont ID  
Sent By csiegber Date 2004-01-20 Time 11:19 Rev Time 0.00
Received By mmclean Date 2004-01-12 Time 16:49 Sent To  
Notes
2004-01-12 00:00:00DENIED, NEED TO SHOW THE WORK ON THE
 SURVEY/GIVE THE LENGTH & WIDTH OF
 DRIVEWAY & PROVIDE AN APPROVED UTILITY
 EASEMENT FROM CALLED OWNER LEFT MSG
 FILE G MM


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved