Plan Review Details - Permit 04010502
Plan Review Stops For Permit 04010502
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-05-13 Cont ID  
Sent By shill Date 2004-05-13 Time 18:41 Rev Time 1.00
Received By shill Date 2004-05-13 Time 18:41 Sent To  
Notes
2004-05-13 00:00:00REVISED A1,A7, A8, A10, A11

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-03-16 Cont ID  
Sent By jleech Date 2004-03-20 Time 10:28 Rev Time 2.00
Received By shill Date 2004-03-16 Time 14:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-02-10 Cont ID  
Sent By jleech Date 2004-03-13 Time 13:15 Rev Time 3.00
Received By shill Date 2004-02-10 Time 15:47 Sent To  
Notes
2004-02-10 00:00:00***CORRECTIONS***
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE STAMPED
 AND THE RECEIPT ATTACHED TO THE
 APPLICATION.233-5025
  
 3.)SHEETS A7, A8, USP TA20R SHOULD
 SPECIFY 10D SIZE NAILS (NOT 10X1 1/2).
 CHECK ALL CONNECTORS.
  
 4.)1 1/2" WATERSTOP REQUIRED, WALL
 SECTIONS SHEET A12, CITY OF WEST PALM
 BEACH AMENDMENTS TO THE FBC2111.1.9.
  
 5.)PROVIDE A STRUCTURAL DETAIL FOR
 THE STAIRS, INCLUDE FIREBLOCKING.
  
 6.)THE GUARDRAILS ARE TO COMPLY WITH
 FBC1608.2.2.
  
 7.)THE WOOD STAIR DETAIL, A13, IS TO
 COMPLY WITH FBC1007.3(1), 2 RISERS AND
 A TREAD IS TO BE NOT LESS THAN 24" NOR
 MORE THAN 25".
  
 8.)GENERAL NOTE #7, A5, STATES THAT
 THE STEEL MULLION DETAIL IS ON A12.
 WHERE IS THE STEEL MULLION TO BE
 INSTALLED, DETAIL NOT ON A12, SEE
 FBC1707.4.5 AND SHOW COMPLIANCE.
  
 9.)THE TEST REPORT SUBMITTED FOR THE
 GARAGE DOOR DOES NOT HAVE FLORIDA
 STATEWIDE PRODUCT APPROVAL ATTACHED
 AS REQUIRED.HOWEVER THIS DOOR ALSO
 DOES NOT MEET THE DESIGN PRESSURE OF
 +38.4/-46.3.
  
 10.) THE MULLION STATEWIDE PRODUCT
 APPROVAL SUBMITTED IS "PENDING".SUBMIT
 A CURRENT REPORT OR SUBMIT A SITE
 SPECIFIC.ALSO CIRCLE THE METHOD OF
 ATTACHMENT IN THE PRODUCT APPROVAL AS
 SOME OF THE METHODS CONTAINED IN THE
 PRODUCT APPROVAL DO NOT MEET THE DESIGN
 PRESSURE ON THE PLAN.
  
 11.)THE SLIDING GLASS DOOR, SINGLE
 HUNG WINDOW, FIXED GLASS WINDOW PRODUCT
 APPROVALS ARE PENDING.SUBMIT SITE
 SPECIFIC OR CURRENT STATEWIDE APPROVAL.
  
 12.)THE TRANSOM WINDOW OVER THE
 SLIDING GLASS DOOR IS 150", THE PRODUCT
 APPROVAL SUBMITTED HAS A LIMITATION
 OF 144".
  
 13.)DESIGNER SHAPE WINDOW PRODUCT
 APPROVALS WERE SUBMITTED; I DO NOT
 SEE ANY ARCHED WINDOWS ON THE PLAN.
 ALSO, THIS PRODUCT APPROVAL IS ALSO
 PENDING.
  
 14.)THE STATEWIDE PRODUCT APPROVALS
 FOR THE THERMATRU DOORS ARE FOR DOORS
 WITH SIDELITES; TEST REPORTS SUBMITTED
 DO NOT CORRESPOND WITH THE STATE
 PRODUCT APPROVALS SUBMITTED.ALSO
 STATE PRODUCT APPROVAL IS PENDING.
  
 15.)THE FOLLOWING PRODUCT APPROVALS
 WERE REVIEWED AND WERE FOUND TO BE IN
 COMPLIANCE:
 WECK GLASS BLOCK
 ENTEGRA ROOF TILE
 ROBICO SHUTTERS

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-09-01 Cont ID  
Sent By dpalmer Date 2004-09-01 Time 13:43 Rev Time 0.25
Received By dpalmer Date 2004-09-01 Time 13:40 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-04-27 Cont ID  
Sent By csiegber Date 2004-08-31 Time 10:59 Rev Time 0.25
Received By dpalmer Date 2004-04-27 Time 19:05 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-01-22 Cont ID  
Sent By csiegber Date 2004-04-26 Time 09:17 Rev Time 0.33
Received By dpalmer Date 2004-01-22 Time 08:19 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-08-31 Cont ID  
Sent By csiegber Date 2004-08-31 Time 10:59 Rev Time 0.00
Received By csiegber Date 2004-08-31 Time 10:59 Sent To E
Notes
2004-08-31 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-04-26 Cont ID  
Sent By csiegber Date 2004-04-26 Time 09:17 Rev Time 0.00
Received By csiegber Date 2004-04-26 Time 09:16 Sent To E
Notes
2004-04-26 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-03-19 Cont ID  
Sent By csiegber Date 2004-03-19 Time 12:24 Rev Time 0.00
Received By csiegber Date 2004-03-19 Time 12:24 Sent To P
Notes
2004-03-19 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-11 Cont ID  
Sent By csiegber Date 2004-03-11 Time 11:03 Rev Time 0.00
Received By csiegber Date 2004-03-11 Time 11:03 Sent To P
Notes
2004-03-11 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-10 Cont ID  
Sent By mmclean Date 2004-01-12 Time 16:33 Rev Time 0.00
Received By csiegber Date 2004-01-09 Time 12:33 Sent To  
Notes
2004-01-13 00:00:00TO SFD RACK/E
2004-01-12 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-02-02 Cont ID  
Sent By dpalmer Date 2004-01-22 Time 08:28 Rev Time 0.20
Received By pkrauss Date 2004-01-30 Time 09:29 Sent To B
Notes
2004-02-02 00:00:00APPROVED 1-30-04

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-03-20 Cont ID  
Sent By dpalmer Date 2004-04-27 Time 19:06 Rev Time 0.33
Received By jleech Date 2004-03-20 Time 10:28 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-03-13 Cont ID  
Sent By csiegber Date 2004-03-19 Time 12:24 Rev Time 0.50
Received By jleech Date 2004-03-13 Time 13:15 Sent To B
Notes
2004-03-13 00:00:00DENIED;
 RISER DIAGRAM DOES NOT MATCH FLOOR PLAN.
 1.RISER B IS MISSING 1 W/C AND 1 TUB.
 2.RISER C IS MISSING BAR SINK.
 3.PLEASE DELETE OLD RISER DIAGRAM FROM
 PLANS.
 PLUMBING PLAN REVIEW BY
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-02-02 Cont ID  
Sent By csiegber Date 2004-03-11 Time 11:03 Rev Time 0.50
Received By jleech Date 2004-02-02 Time 10:42 Sent To B
Notes
2004-02-02 00:00:00DENIED;
 MASTER BATHROOM IS NOT SHOWN ON RISER
 DIAGRAM.RISER DIAGRAM "A" TUB IS NOT
 VENTED. RISER DIAGRAM DOES NOT MATCH
 FLOOR PLAN.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status P Date 2004-01-12 Cont ID  
Sent By mmclean Date 2004-01-12 Time 16:33 Rev Time 0.00
Received By mmclean Date 2004-01-12 Time 16:33 Sent To I
Notes
***NONE***