Plan Review Details - Permit 04010408
Plan Review Stops For Permit 04010408
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2004-05-05 Cont ID  
Sent By rmcdouga Date 2004-05-05 Time 08:21 Rev Time 0.00
Received By rmcdouga Date 2004-05-05 Time 08:20 Sent To  
Notes
2004-05-05 00:00:00SUBMITTAL FOR COLLIER GARAGE DOOR IS OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-04-08 Cont ID  
Sent By rmcdouga Date 2004-04-09 Time 08:18 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2004-04-09 00:00:00SUBMITTALS FOR PROVISO ITEMS #1 AND #3
 ARE OK. A SIGNED AND SEALED REPORT FROM
 THE ENGINEER STATING THAT THE BUTT
 GLASS HAS BEEN INSTALLED PER HIS
 SPECIFICATIONS IS REQUIRED BEFORE THE
 C.O. IS ISSUED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-03-31 Cont ID  
Sent By csiegber Date 2004-04-06 Time 14:16 Rev Time 2.00
Received By rmcdouga Date 2004-03-31 Time 10:41 Sent To  
Notes
2004-03-31 00:00:00BUILDING PROVISO
  
 1) SUBMIT SITE SPECIFIC PRODUCT APPROVAL
 FOR BUTT GLASS WINDOW BEFORE INSTALLING.
 2) SUBMIT STATE PRODUCT APPROVAL FOR
 COLLIER GARAGE DOORS WITH A STATUS OF
 APPROVED BEFORE INSTALLING. SUBMIT
 INSTALL DRAWINGS FOR THE SMALL GARAGE
 DOOR BEFORE INSTALLING.
 3) SUBMIT INSTALLATION DETAIL MID-WL-MA
 0001-02 FOR THE SINGLE OUTSWING DOOR
 BEFORE INSTALLING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-03-18 Cont ID  
Sent By csiegber Date 2004-03-25 Time 17:04 Rev Time 2.00
Received By rmcdouga Date 2004-03-18 Time 08:05 Sent To  
Notes
2004-03-18 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) THE STATE PRODUCT APPROVAL FOR THE
 COLLIER GARAGE DOOR HAS A STATUS OF
 VALIDATED. SUBMIT STATE PRODUCT APPROVAL
 WITH APPROVED STATUS.
  
 3) SUBMIT STATE PRODUCT APPROVAL FOR THE
 8'X 7' GARAGE DOOR. THE DRAWING THAT WAS
 SUBMITTED FOR THE COLLIER GARAGE DOOR IS
 LIMITED TO A MINIMUM SIZE OF 10'X 6'.
  
 4) SUBMIT STATE PRODUCT APPROVAL FOR THE
 2-4 X 6-8 EXTERIOR SINGLE OUTSWING DOOR
 AT THE LAUNDRY ROOM.
  
 5) THE LOCAL PRODUCT APPROVAL SUBMITTED
 FOR THE BUTT GLASS WINDOW IS INCOMPLETE.
 SEE RULE 9B-72. SPECIFY METHOD 1 OR
 METHOD 2 ON THE FORM. INDICATE THE
 CATEGORY OF PRODUCT. LIST AN APPROVED
 THIRD PARTY ASSURANCE ENTITY. LIST ALL
 THE INFORMATION THAT IS REQUIRED FOR AN
 EVALUATION REPORT FROM A FLORIDA
 PROFESSIONAL ENGINEER AS LISTED FOR ITEM
 #5 IN 9B-72.040. SPECIFY ANY LIMITATIONS
 (SUCH AS IMPACT PROTECTION REQUIRED).
 LIST THE REQUIREMENTS THAT THE PRODUCT
 COMPLIES WITH INCLUDING CODE SECTION
 NUMBERS AND REFERENCE STANDARDS, SUCH AS
 FBC 1606, 1707, 2406.2 AND TAS 202.
 SUBMIT TEST REPORTS, TECHNICAL DOCUMENTS
 CALCULATIONS, ETC. UPON WHICH THE
 RATIONAL ANALYSIS IS BASED. PROVIDE A
 DETAILED REPORT INDICATING HOW THE
 CONCLUSIONS WERE REACHED. INDICATE THE
 PARAMETERS FOR WHICH THE REPORT IS
 VALID, SUCH AS GLASS SIZES, ANGLES, ETC.
  
 6) THE PRODUCT APPROVAL FOR THE STORM
 PANELS LISTS SEVERAL TYPES OF ANCHORS
 AND CONNECTION TYPES. SPECIFY THE
 ANCHORS AND CONNECTION TYPE THAT WILL BE
 USED ON THIS PROJECT BY CIRCLING OR
 HIGHLITING THE APPROPRIATE ONES ON THE
 PRODUCT APPROVAL.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-02-12 Cont ID  
Sent By csiegber Date 2004-03-01 Time 12:08 Rev Time 2.00
Received By rmcdouga Date 2004-02-12 Time 14:00 Sent To  
Notes
2004-02-12 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) FBC* 1804.2.2AREA OF QUESTIONABLE
 SOIL.SUBMIT A GEOTECHNICAL REPORT
 TO VERIFY THE SAFE BEARING CAPACITY OF
 THE SOIL.
  
 3)1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
 REVISE TRUSS ANCHOR SCHEDULE USING
 VALUES THAT DO NOT INCLUDE THE ONE-
 THIRD INCREASE. TRUSS ANCHORS ARE
 REQUIRED TO HAVE STATE OR LOCAL PRODUCT
 APPROVAL.
  
 4)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 5) SUBMIT STATE OR LOCAL PRODUCT
 APPROVAL IN ACCORDANCE WITH RULE 9B-72,
 FOR THE BUTT GLASS WINDOW. SPECIFY THE
 TYPE OF GE SILCONE TO BE USED. THE
 HEIGHT DIMENSION ON THE PLAN IS NOT
 CONSISTANT.
  
 6) THE COLLIER GARAGE DOOR REQUIRES
 STATE OR LOCAL PRODUCT APPROVAL IN
 ACCORDANCE WITH RULE 9B-72, INCLUDING
 QUALITY ASSURANCE. SUBMIT FORM FOR LOCAL
 PRODUCT APPROVAL. THE SIZE LIMITATION IN
 THE ENGINEERED DRAWINGS EXCLUDE THE
 SMALLER GARAGE DOOR SHOWN ON THE PLANS.
  
 7) SUBMIT THE APPROVED ENGINEERING AND
 INSTALLATION INSTRUCTIONS FOR THE ENTRY
 DOOR.
  
 8) SPECIFY THE MOUNT TYPE AND ANCHORS
 THAT WILL BE USED FOR THE STORM PANELS.
  
 9) SUBMIT STATE OR LOCAL PRODUCT
 APPROVAL FOR THE TRUSS ANCHORS THAT ARE
 SPECIFIED ON THE PLANS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-01-22 Cont ID  
Sent By dpalmer Date 2004-01-22 Time 10:50 Rev Time 0.50
Received By dpalmer Date 2004-01-22 Time 10:50 Sent To M
Notes
2004-01-22 00:00:00*************NOTES *******
 REDLINED.
  
 210.52 LIV RM
 210.8A6 KIT.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-04-06 Cont ID  
Sent By csiegber Date 2004-04-06 Time 14:16 Rev Time 0.00
Received By csiegber Date 2004-04-06 Time 14:16 Sent To B
Notes
2004-04-06 00:00:00TO RM DESK/SUBMITTAL OF PROVISO

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-03-25 Cont ID  
Sent By csiegber Date 2004-03-25 Time 17:04 Rev Time 0.00
Received By csiegber Date 2004-03-25 Time 17:03 Sent To B
Notes
2004-03-25 00:00:00TO RM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-01 Cont ID  
Sent By csiegber Date 2004-03-01 Time 12:07 Rev Time 0.00
Received By csiegber Date 2004-03-01 Time 12:07 Sent To B
Notes
2004-03-01 00:00:00TO RM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-12 Cont ID  
Sent By mmclean Date 2004-01-12 Time 16:40 Rev Time 0.00
Received By csiegber Date 2004-01-09 Time 12:33 Sent To  
Notes
2004-01-13 00:00:00TO SFD RACK/E
2004-01-12 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-01-30 Cont ID  
Sent By dpalmer Date 2004-01-22 Time 10:50 Rev Time 0.33
Received By pkrauss Date 2004-01-30 Time 07:47 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-02-02 Cont ID  
Sent By pkrauss Date 2004-01-30 Time 08:02 Rev Time 0.33
Received By jleech Date 2004-02-02 Time 12:27 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-01-12 Cont ID  
Sent By mmclean Date 2004-01-12 Time 16:40 Rev Time 0.00
Received By mmclean Date 2004-01-12 Time 16:40 Sent To I
Notes
***NONE***