Plan Review Details - Permit 04010280
Plan Review Stops For Permit 04010280
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-05-19 Cont ID  
Sent By alange Date 2004-05-19 Time 16:05 Rev Time 0.50
Received By alange Date 2004-05-19 Time 16:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-05-06 Cont ID  
Sent By alange Date 2004-05-19 Time 15:51 Rev Time 0.00
Received By alange Date 2004-05-19 Time 15:51 Sent To  
Notes
2004-05-06 00:00:00DENIED
 1. THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSEAND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2. BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.ENERGY CALCS NOT SIGNED BY OWNER/
 AGENT. PLEASE SIGN AND RESUBMIT.
  
 ANY QUESTIONS CALL ME
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-01-27 Cont ID  
Sent By dpalmer Date 2004-05-05 Time 18:12 Rev Time 1.50
Received By alange Date 2004-01-27 Time 12:52 Sent To  
Notes
2004-01-27 00:00:001.ALL INFORMATION, DRAWINGS, SPECIF-
 ICATIONS AND ACCOMPANYING DATA SHALL
 BEAR THE NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN.
 CITY AMENDMENTS 104.2.1
 2.PRODUCT APPROVALS MISSING:
 FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES OF PRODUCT
 TESTING REPORTS AND IMPACT REPORTS.
 3.SPECIFY GROUND CLEARANCE FOR JOISTS
 AND BEAMS SO THAT THEY COMLY WITH
 SECTION 2304 FBC
 4.SHOW FRAMING DETAIL TO INCLUDE
 MATERIALS USED, SIZES, HEADERS AND
 STRAPING. 5.SHOW BUCK DETAIL FOR
 WINDOWS AND DOOORS.
 5.SUBMIT ENERGY CALCULATIONS.
 6.SUBMIT WINDOW PRESSURES.
 7.SHOW DETAIL FOR RAILING AND
 BALISTERS.
 8.PLEASE SHOW FASTENING DETAIL FOR
 2 X 10 DOUBLE LEDGER TO WALL.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-05-05 Cont ID  
Sent By dpalmer Date 2004-05-05 Time 17:58 Rev Time 0.50
Received By dpalmer Date 2004-05-05 Time 17:58 Sent To B
Notes
2004-05-05 00:00:00**** NOTE REDLINED *****
  
 1)NOTE: PLEASE SEE CHAPTER 34 OF THE
 FBC. 3401.7.1.2.1
 ADDITIONS TO EXISTING DWELLINGS OF 25%,
 EXSITING HOUSE MUST HAVE ALL SD'S AND
 REQ'D GFI'S BROUGHT UP TO THE 2002 NEC.
 210.52G, 210.52E, 210.52D,210.11C3
 NFPA-72 8-1.4.2
  
 2)NOTE: LISTING FOR ARC FAULT MISSING.
 2002 NEC 210.12

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-01-13 Cont ID  
Sent By pkrauss Date 2004-05-05 Time 15:40 Rev Time 1.00
Received By btrobaug Date 2004-01-13 Time 13:55 Sent To M
Notes
2004-01-13 00:00:00 
 UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 AND RESUBMIT FOR REVIEW.
  
 1} PLEASE NOTE, ALL PLANS DRAWN
 BY AN ARCHITECT/ENGINEER CONTAIN-
 -ING A TITLE BLOCK: MUST BE SIGNED,
 DATED AND SEALED BY THAT ARCH/ENG.
 PER FS 481.221 471.025
 FAC 61G15-23.002, 61G1-16.004
 INITIALS ARE NOT ACCEPTABLE PER FBPE.
  
 2} THE BATH AND "EXT DOCK" LISTED ON THE
 PANEL SCHEDULE IS IN VIOLATION OF
 210.11(C)(3),NO OTHER OUTLETS.
  
 3} THE BATH NEEDS ANOTHER RECEPTACLE TO
 COMPLY WITH 210.52(D).
  
 4} THE BEDROOM AND DINING ROOM REQUIRE
 SMOKE DETECTORS TO COMPLY WITH 905.2.2
 FBC,AND CH.8 NFPA-72.
  
 5} PLEASE SEE RECEPTS SERVING
 KITCHEN COUNTERSPACE TO MEET 210.52C-
 SEC'S 1,2,3,4 AND 5
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-05-19 Cont ID  
Sent By alange Date 2004-05-19 Time 15:51 Rev Time 0.00
Received By alange Date 2004-05-19 Time 15:51 Sent To B
Notes
2004-05-19 00:00:00TO ART LANGE

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-04-20 Cont ID  
Sent By csiegber Date 2004-04-20 Time 16:42 Rev Time 0.00
Received By csiegber Date 2004-04-20 Time 16:42 Sent To P
Notes
2004-04-20 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-01-09 Cont ID  
Sent By csiegber Date 2004-01-09 Time 09:21 Rev Time 0.00
Received By csiegber Date 2004-01-09 Time 09:21 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-01-07 Cont ID  
Sent By mmclean Date 2004-01-08 Time 15:46 Rev Time 0.00
Received By csiegber Date 2004-01-07 Time 14:37 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-05-05 Cont ID  
Sent By pkrauss Date 2004-05-05 Time 15:39 Rev Time 0.30
Received By pkrauss Date 2004-05-05 Time 15:39 Sent To E
Notes
2004-05-05 00:00:00PROVISO:
 FORM 600C SUBMITTED FOR 477 SQ FT
 ADDITION.PLEASE NOTE THE FOLLOWING
 SHALL BE INCORPORATED ON THE
 INSTALLATION:
  
 1.RETURN AIR REQUIRED FROM THE NEW
 MASTER BEDROOM.TRANSFER JUMPER OR
 TRANSFER GRILLES SHALL BE SIZED PER THE
 ATTACHED SCHEDULE.PLEASE NOTE, ALLL
 AIR INTO THE SUITE TO BEINCLUDED FOR
 PROPER SIZING OF THE RETURN.
  
 2.BATHROOM WINDOW SHALL HAVE A MINIMUM
 OF 3 SQ FT OF OPEN AREA OR HAVE
 MECHANICAL VENTILATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2004-01-21 Cont ID  
Sent By pschmitz Date 2004-05-03 Time 17:51 Rev Time 0.25
Received By hmoser Date 2004-01-21 Time 15:50 Sent To B
Notes
2004-01-21 00:00:00MECHANICAL COMTRACTOR NEEDS TO SUBMIT
 ENERGY CALCULATIONS,MANUAL (J),PLANS
 WITH PERMIT APPLICATION
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-05-03 Cont ID  
Sent By pschmitz Date 2004-05-03 Time 17:49 Rev Time 1.00
Received By pschmitz Date   Time   Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-01-15 Cont ID  
Sent By csiegber Date 2004-04-20 Time 16:43 Rev Time 0.50
Received By kstevens Date 2004-01-15 Time 15:29 Sent To M
Notes
2004-01-15 00:00:00DENIED
 REFERENCE: FLA. ADMIN. CODE
 FLA. STATUTES
  
 1) SIGNED AND SEALED SITE PLAN REQUIRES
 A TITLE BLOCK. 61G15-23.002(2) & FS 471.
 2) SIGNATURE REQUIRED ON SEAL PER FAC
 61G15-23.002(1) & FS 471. RULING BY THE
 FBPE TO CITY WPB STATES THAT INITIALS
 ARE NOT ACCEPTABLE.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-01-08 Cont ID  
Sent By csiegber Date 2004-01-07 Time 14:37 Rev Time 0.00
Received By mmclean Date 2004-01-08 Time 15:46 Sent To I
Notes
***NONE***