| Plan Review Stops For Permit 04010144 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-03-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-03-16 |
Time |
12:19 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2004-03-16 |
Time |
12:19 |
Sent To |
PC |
|
| Notes |
| 2004-03-16 00:00:00 | BUILDING REVIEW PROVISO: | | | 1-ENERGY CALCULATIONS: A)CLARIFY HOW IS | | | R-11 INSULATION ACHIEVED ON EXTERIOR | | | CONCRETE BLOCK WALLS. | | | 2-PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: A)MULIA GLASS BLOC. | | | B)PGT WINDOW MULLIONS WITH DRAWINGS THAT | | | MATCH FLORIDA APPROVAL REPORT. | | | C)ENTRY DOORS WITH DRAWINGS THAT MATCH | | | FLORIDA PRODUCT APPROVAL. CLARIFY IF | | | USING "BENCHMARK" OR THERMA-TRU. THEY | | | ARE TWO DIFFERENT MODELS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-03-11 |
Time |
19:29 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2004-02-05 |
Time |
08:39 |
Sent To |
PC |
|
| Notes |
| 2004-02-05 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-PROVIDE COMPLETE FLORIDA/SITE SPECIFIC | | | PRODUCT APPROVAL FOR DOORS, WINDOWS, | | | GLASS BLOCK, ROOF TILE, MULLIONS AND | | | ALL STRUCTURAL CONNECTORS UNDER A | | | SEPARATE PERMIT. | | | 2-DETAIL E/4 AND RESIDENTIAL NOTES ON | | | DWG #2 DON'T MATCH. REVISE AS REQUIRED | | | 3-CLARIFY/REVISE TRUSS ANCHOR SCHEDULE. | | | 4-TYPICAL WALL SECTION A/4: SPECIFY | | | WHERE ARE TABLES 6 AND 8 FOR ROOF TILE | | | FASTENING TAKEN FROM?. SEC. 104.2.1.2 | | | CITY AMENDMENTS TO FBC 2001. | | | 5-SHEET #7: A)REVISE/CLARIFY DESIGN | | | PRESSURES SHOWN ON REAR ELEVATION. | | | THEY DON'T MATCH THOSE SHOWN ON DWG 3B | | | B)WINDOWS SHOWN ON REAR ELEVATION DON'T | | | MATCH THOSE SHOWN ON WINDOW SCHEDULE. | | | C)REVISE FLOOR PLAN & ROOF FRAMING PLAN | | | NOTES TO REFLECT CHANGE OF WOOD BM TO | | | CONCRETE BEAM. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | 6-SHEET #3:CLARIFY/REVISE NOTE REGARDING | | | CONNECTORS SELECTED FOR UPLIFT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-03-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-03-11 |
Time |
19:28 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-03-11 |
Time |
19:23 |
Sent To |
B |
|
| Notes |
| 2004-03-11 00:00:00 | REDLINED SD'S TO BE A MIN OF 3'FROM | | | BATH DOORS. | | | SD'D TO BE INSTALLED PER NFPA-71 8-1.4.2 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-10 |
Time |
10:05 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-01-22 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2004-01-22 00:00:00 | **************** UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE THAT ONE SET IS NOW | | | INCOMPLETE AND MISSING ELECTRICAL | | | SHEET. | | | | | | PLEASE SUBMIT FOR REVIEW. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-01-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-09 |
Time |
06:13 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-01-09 |
Time |
06:13 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-03-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-01 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-01 |
Time |
15:41 |
Sent To |
P |
|
| Notes |
| 2004-03-01 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-02-05 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2004-01-06 |
Time |
13:41 |
Sent To |
PC |
|
| Notes |
| 2004-01-20 00:00:00 | TO KS BOX | | 2004-01-06 00:00:00 | TO Z | | | TO E/DP |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-03-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-10 |
Time |
10:05 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2004-03-10 |
Time |
10:05 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-05 |
Time |
12:10 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-01-22 |
Time |
14:46 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-03-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-05 |
Time |
12:10 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-03-05 |
Time |
12:10 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-01 |
Time |
15:41 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-01-22 |
Time |
07:49 |
Sent To |
M |
|
| Notes |
| 2004-01-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | | | | 1) TWO OR MORE COPIES OF DRAWING REQUIR- | | | ED FOR PLAN REVIEW. SHEET 5 MISSING FROM | | | ONE SET OF PLANS. PLEASE RESUBMIT TWO | | | COMPLETE SETS OF PLANS FOR REVIEW. | | | SECTION 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-01-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-06 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-01-06 |
Time |
12:35 |
Sent To |
I |
|
| Notes |
|
|