Plan Review Details - Permit 04010138
| Plan Review Stops For Permit 04010138 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-27 |
Time |
12:09 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2004-02-05 |
Time |
12:11 |
Sent To |
PC |
|
| Notes |
| 2004-02-05 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-PROVIDE COMPLETE AND CURRENT PRODUCT | | | APPROVAL FOR DOORS, WINDOWS, MULLIONS, | | | GLASS BLOCK, ROOF TILE AND ALL THE | | | STRUCTURAL CONNECTORS UNDER A SEPARATE | | | PERMIT AS REQ'D BY THE BLDG OFFICIAL. | | | 2-DETAIL E/4 AND RESIDENTIAL NOTES ON | | | DWG #2 DON'T MATCH. REVISE AS REQ'D. | | | 3- CLARIFY/REVISE TRUSS ANCHOR SCHEDULE. | | | 4-TYP. WALL SECTION. CLARIFY WHERE ARE | | | TABLES 6 AND 8 COMING FROM? SECTION | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | 5-SHEET #7: A)REVISE DESIGN PRESSURES | | | SHOWN ON REAR ELEVATION. | | | B)WINDOWS TO MATCH WINDOW SCHEDULE. | | | C)ALL NOTES ON FLOOR PLAN AND ROOF FRA- | | | MING PLAN TO REFLECT BEAM CHANGE FROM | | | WOOD TO CONCRETE. | | | 6- SHEET #3: CLARIFY NOTE REGARDING THE | | | UPLIFT CALCS AND CONNECTORS SELECTED. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-01-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-09 |
Time |
07:58 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-01-09 |
Time |
07:58 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-02-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-27 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-27 |
Time |
12:09 |
Sent To |
B |
|
| Notes |
| 2004-02-27 00:00:00 | TO JG DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-02-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-11 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-11 |
Time |
16:06 |
Sent To |
B |
|
| Notes |
| 2004-02-11 00:00:00 | TO JG DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-02-05 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2004-01-06 |
Time |
13:37 |
Sent To |
PC |
|
| Notes |
| 2004-01-20 00:00:00 | TO KS BOX | | 2004-01-06 00:00:00 | TO Z | | | TO E/DP |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-22 |
Time |
07:41 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-01-22 |
Time |
15:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-22 |
Time |
07:41 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-01-22 |
Time |
07:41 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-01-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-06 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-01-06 |
Time |
12:33 |
Sent To |
I |
|
| Notes |
|
|
|