Plan Review Details - Permit 04010131
| Plan Review Stops For Permit 04010131 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-06-23 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2004-06-23 |
Time |
16:35 |
Sent To |
PC |
|
| Notes |
| 2004-06-23 00:00:00 | PRODUCT APPROVAL SUBMITTAL CHECKLIST: | | | 1-PROVIDE COPIES OF GARAGE DOOR DRAWINGS | | | SUBMITTED TO SBCCI FOR APPROVAL. NEED | | | DRAWINGS SIGNED AND SEALED ON DATE AS | | | NOTED ON SBCCI EVALUATION REPORT. | | | 2-PROVIDE FLORIDA PRODUCT APPROVAL COVER | | | PAGE FOR ENTRY DOOR THAT MATCHES DADE | | | COUNTY NOA SUBMITTED. BENCHMARK AND | | | THERMA-TRU ARE 2 DIFFERENT TYPE OF | | | DOORS. | | | 3-SIMONTON DOORS/WINDOWS PACKAGE IS | | | INCOMPLETE. NEED FLORIDA PRODUCT | | | APPROVAL COVER PAGE FOR FIXED WINDOWS | | | AND SLIDING GLASS DOORS TO BE USED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-02-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-27 |
Time |
12:24 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2004-02-06 |
Time |
09:22 |
Sent To |
PC |
|
| Notes |
| 2004-02-06 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-PROVIDE COMPLETE CURRENT PRODUCT | | | APPROVAL FOR ALL DOORS, WINDOWS, ROOF | | | TILE, MULLIONS, GLASS BLOCK, AND ALL | | | STRUCTURAL CONNECTORS UNDER A SEPARATE | | | PERMIT. | | | 2-DETAIL E/4 AND RESIDENTIAL NOTES ON | | | DWG #2 DON'T MATCH. REVISE AS REQ'D. | | | 3-CLARIFY/REVISE TRUSS ANCHOR SCHEDULE. | | | 4-TYPCIAL WALL SECTION DETAIL A/4: | | | CLARIFY WHERE ARE TABLES 6 AND 8 FOR | | | ROOF TILE FASTENERS TAKEN FROM?. SEE | | | SEC. 1606.3 FBC 2001 & SEC. 104.2.1.1 | | | CITY AMENDMENTS TO FBC 2001. | | | 5-SHEET #7:A)REVISE DESIGN PRESSURES. | | | B)WINDOWS ON REAR ELEVATION DON'T MATCH | | | THOSE ON WINDOW SCHEDULE. | | | C)REVISE AL NOTES ON FLOOR PLAN AND ROOF | | | FRAMING PLAN TO REFLECT CHANGE OF WOOD | | | BEAM TO CONCRETE BEAM. | | | 6-SHEET #3: CLARIFY NOTE REGARDING THE | | | UPLIFT CALCS AND CONNECTORS SELECTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-01-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-09 |
Time |
07:41 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-01-09 |
Time |
07:41 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-02-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-27 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-27 |
Time |
12:24 |
Sent To |
B |
|
| Notes |
| 2004-02-27 00:00:00 | TO JG DESK/SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-02-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-11 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-11 |
Time |
16:08 |
Sent To |
B |
|
| Notes |
| 2004-02-11 00:00:00 | TO JG DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-02-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-02-06 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2004-01-06 |
Time |
13:38 |
Sent To |
PC |
|
| Notes |
| 2004-01-20 00:00:00 | TO KS BOX | | 2004-01-06 00:00:00 | TO Z | | | TO E/DP |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-21 |
Time |
18:53 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-01-22 |
Time |
15:17 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-01-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-21 |
Time |
18:53 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-01-21 |
Time |
18:53 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-01-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-06 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-01-06 |
Time |
12:28 |
Sent To |
I |
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy