| Plan Review Stops For Permit 04010105 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-06-23 |
Time |
14:39 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2004-06-23 |
Time |
14:39 |
Sent To |
PC |
|
| Notes |
| 2004-06-23 00:00:00 | PRODUCT APPROVAL SUBMITTAL CHECKLIST: | | | 1-PROVIDE COPIES OF GARAGE DOOR DRAWINGS | | | SUBMITTED TO SBCCI FOR APPROVAL. NEED | | | DRAWINGS SIGNED AND SEALED ON THE | | | DATE NOTED ON THE SBCCI EVALUATION | | | REPORT. | | | 2-PROVIDE FLORIDA PRODUCT APPROVAL COVER | | | PAGE FOR ENTRY DOOR THAT MATCHES DADE | | | COUNTY NOA SUBMITTED. BENCHMARK AND | | | THERMA-TRU DOORS ARE TWO DIFFERENT | | | MODELS. | | | 3-SIMONTON WINDOWS/DOORS PACKAGE IS | | | INCOMPLETE. NEED FLORIDA PRODUCT | | | APPROVAL COVER PAGE FOR FIXED WINDOWS | | | AND SLIDING GLASS DOORS USED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-27 |
Time |
12:25 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2004-02-05 |
Time |
15:15 |
Sent To |
PC |
|
| Notes |
| 2004-02-05 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-ARCHITECT TO PROVIDE ALL INFO. REQ'D | | | IN ALL DRAWINGS BY CHAPTER 481 FL. ST. | | | 2-PROVIDE COMPLETE/CURRENT PRODUCT APPRO | | | VAL FOR ALL DOORS, WINDOWS, MULLIONS, | | | GLASS BLOCK, ROOF TILE AND ALL STRUC- | | | TURAL CONNECTORS UNDER A SEPARATE | | | PERMIT. | | | 3-DETAIL E/4 AND RESIDENTIAL NOTES ON | | | DWG #2 DON'T MATCH. REVISE AS REQ'D. | | | 4-REVISE WINDOW BUCK DETAIL./ SEE SEC. | | | 1707.4.4.2 FBC 2001. | | | 5-DWG #2: A)CLARIFY/REVISE TRUSS ANCHOR | | | SCHEDULE. | | | B)PROVIDE ENGINEERING CALCS AND DETAILS | | | AS SPECIFIED ON NOTE. | | | 6-SPECIFY ROOF TILE FASTENERS. SEE SEC. | | | 1606.3 FBC 2001 AND SEC. 104.2.1.1 | | | CITY AMENDMENTS TO FBC 2001. | | | 7-PROVIDE REVISED ROOF FRAMING PLAN | | | SHOWING CHANGE FROM WOOD BM TO MASONRY | | | BEAM. SEC. 104.2.1.2 CITY AMENDMENTS. | | | 8-SHEET #3: CLARIFY NOTE REGARDING UP- | | | LIFT CALCS AND CONNECTORS SPECIFIED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-20 |
Time |
11:30 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2004-01-16 |
Time |
14:28 |
Sent To |
PC |
|
| Notes |
| 2004-01-16 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1-ARCHITECT TO COMPLY WITH CHAPTER 481 | | | FLORIDA STATUTES WHEN SUBMITTING PLANS | | | FOR PUBLIC RECORDS. | | | 2-NEED RECORDED NOTICE OF COMMENCEMENT. | | | 3-PROVIDE COMPLETE FLORIDA/SITE SPECIFIC | | | PRODUCT APPROVAL FOR ALL DOORS/WINDOWS | | | TYPE, MULLIONS, GLASS BLOCK ROOF TILE, | | | STRUCTURAL CONNECTORS. | | | 4-PROVIDE SPECIFIC UL LISTING FOR ONE HR | | | FIRE RATED GLASS BLOCK ASSEMBLY AND | | | REVISE DETAIL TO MATCH IT. SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | 5-GARAGE BUCK DETAIL AND NOTES ON DWG #2 | | | DON'T MATC. CHECK SIZE OF FASTENER. | | | 6-UPDATE TRUSS ANCHOR SCHEDULE. SEE SEC. | | | 1609.4.3 FBC 2001. | | | B)SPECIFY SIZE OF USP RT STRAP. SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | 7-DESIGNER OF RECORD TO SPECIFY ROOF | | | TILE. SEC. 104.2.1.1 CITY AMENDMENTS. | | | 8-REVISE WINDOW BUCK DETAIL. SEE SEC. | | | 1707.4.4.2 FBC 2001 FOR PROPER BUCK | | | INSTALLATION. | | | 9-REVISE DESIGN PRESSURES. SEE TABLES | | | 1606.2B AND 1606.2E FOR SIZE AND | | | LOCATION. PROVIDE CALCULATIONS FOR | | | DIFFERENT DESIGN PRESSURES. SECTION | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | 10-PROVIDE ENGINEERING CALCS FOR SIMPSON | | | EG-7 CONNECTOR. FASTENER SPECIFIED IS | | | DIFFERENT FROM THAT PUBLISHED ON | | | CATALOGUE. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-01-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-12 |
Time |
07:26 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-01-12 |
Time |
07:26 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-02-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-27 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-27 |
Time |
12:25 |
Sent To |
B |
|
| Notes |
| 2004-02-27 00:00:00 | TO JG DESK/SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-02-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-11 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-11 |
Time |
16:08 |
Sent To |
B |
|
| Notes |
| 2004-02-11 00:00:00 | TO JG DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-01-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-20 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-20 |
Time |
11:30 |
Sent To |
B |
|
| Notes |
| 2004-01-20 00:00:00 | TO JG DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-01-16 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-06 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2004-01-06 |
Time |
12:16 |
Sent To |
PC |
|
| Notes |
| 2004-01-06 00:00:00 | TO Z | | | TO E/DP |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-12 |
Time |
07:28 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2004-01-14 |
Time |
15:50 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-01-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-14 |
Time |
16:09 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-01-16 |
Time |
09:48 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-01-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-06 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-01-06 |
Time |
12:57 |
Sent To |
I |
|
| Notes |
|
|