| Plan Review Stops For Permit 04010039 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-06-23 |
Time |
10:17 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2004-06-23 |
Time |
10:17 |
Sent To |
PC |
|
| Notes |
| 2004-06-23 00:00:00 | PRODUCT APPROVAL SUBMITTAL CHECKLIST: | | | 1-PROVIDE COPIES OF GARAGE DOOR DRAWINGS | | | SUBMITTED TO SBCCI FOR APPROVAL. NEED | | | DRAWINGS SIGNED AND SEALED ON DATE | | | NOTED ON SBCCI EVALUATION REPORT. | | | 2-PROVIDE FLORIDA PRODUCT APPROVAL COVER | | | PAGE FOR ENTRY DOOR THAT MATCHES DADE | | | COUNTY NOA SUBMITTED. BENCHMARK AND | | | THERMA-TRU ARE 2 DIFFERENT MODELS. | | | 3-SIMONTON WINDOWS/DOORS PACKAGE IS | | | INCOMPLETE. NEED FLORIDA PRODUCT | | | APPROVAL COVER PAGE FOR FIXED WINDOWS | | | AND SLIDING GLASS DOORS USED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-03-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-03-30 |
Time |
12:59 |
Rev Time |
0.33 |
| Received By |
jgomez |
Date |
2004-03-30 |
Time |
12:59 |
Sent To |
PC |
|
| Notes |
| 2004-03-30 00:00:00 | ENGINEER LETTER ADDRESSING CLARIFICATION | | | ON ITEMS REQUESTED ON PROVISO: |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-27 |
Time |
12:11 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2004-02-05 |
Time |
09:53 |
Sent To |
PC |
|
| Notes |
| 2004-02-05 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-ARCHITECT TO PROVIDE ALL HIS INFO IN | | | ALL DWGS AS REQUIRED BY CHAPTER 481 | | | FLORIDA STATUTES. | | | 2-PROVIDE COMPLETE FLORIDA/SITE SPECIFIC | | | PRODUCT APPROVAL FOR DOORS, WINDOWS, | | | MULLIONS, GLASS BLOCK, ROOF TILE AND | | | ALL STRUCTURAL CONNECTORS UNDER A | | | SEPARATE PERMIT. | | | 3-DETAIL E/4 AND RESIDENTIAL NOTES ON | | | DWG #2 DON'T MATCH. REVISE AS REQ'D. | | | 4-REVISE WINDOW BUCK DETAIL. SEE SECTION | | | 1707.4.4.2 FBC 2001. | | | 5-DWG #2: A)REVISE/CLARIFY TRUSS ANCHOR | | | SCHEDULE. | | | B)PROVIDE ENGINEER'S DETAILS AND CALCS | | | AS SPECIFIED ON NOTE. | | | | | | 6-SPECIFY ROOF TILE FASTENERS. SECTION | | | 1606.3 FBC 2001 & SEC. 104.2.1.1 CITY | | | AMENDMENTS TO FBC 2001. | | | 7-PROVIDE REVISED ROOF FRAMING PLAN | | | SHOWING CONCRETE BEAM INSTEAD OF WOOD | | | BEAM. SEC. 104..2.1.2 CITY AMENDMENTS. | | | 8-SHEET #3: CLARIFY NOTE REGARDING | | | UPLIFT AND CONNECTORS SELECTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-01-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-12 |
Time |
07:20 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-01-12 |
Time |
07:20 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-02-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-27 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-27 |
Time |
12:11 |
Sent To |
B |
|
| Notes |
| 2004-02-27 00:00:00 | TO JG DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-02-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-11 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-11 |
Time |
16:04 |
Sent To |
B |
|
| Notes |
| 2004-02-11 00:00:00 | TO JG DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-06 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2004-01-06 |
Time |
12:17 |
Sent To |
PC |
|
| Notes |
| 2004-01-20 00:00:00 | TO JG DESK/RESUB | | 2004-01-06 00:00:00 | TO Z | | | TO E/DP |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-12 |
Time |
07:20 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2004-01-14 |
Time |
15:50 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-01-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-14 |
Time |
15:50 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-01-16 |
Time |
09:53 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-01-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-06 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-01-06 |
Time |
12:55 |
Sent To |
I |
|
| Notes |
|
|