Plan Review Details - Permit 04010031
Plan Review Stops For Permit 04010031
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2004-05-05 Cont ID  
Sent By rmcdouga Date 2004-05-05 Time 09:07 Rev Time 0.00
Received By rmcdouga Date 2004-05-05 Time 09:06 Sent To  
Notes
2004-05-05 00:00:00SUBMITTAL FOR COLLIER GARAGE DOORS IS OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2004-04-16 Cont ID  
Sent By rmcdouga Date 2004-04-16 Time 11:03 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2004-04-16 00:00:00SUBMITTAL FOR SITE SPECIFIC BUTT GLASS
 IS OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2004-04-08 Cont ID  
Sent By csiegber Date 2004-04-16 Time 08:12 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2004-04-09 00:00:00PROVISO ITEM #3 FOR SINGLE HINGED DOOR
 WAS RECIEVED AND IS OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2004-04-06 Cont ID  
Sent By csiegber Date 2004-04-06 Time 14:17 Rev Time 0.00
Received By rmcdouga Date 2004-04-06 Time 10:45 Sent To  
Notes
2004-04-06 00:00:00SUBMITTAL FOR BUTT GLASS DOES NOT HAVE A
 COMPLETED SITE SPECIFIC PRODUCT APPROVAL
 FORM. SPECIFY THAT IMPACT PROTECTION IS
 REQUIRED. SUBMIT PRODUCT APPROVAL FOR
 THE ALUMINUM FRAME. SPECIFY HOW GLASS IS
 TO BE INSTALLED INTO FRAME AND HOW FRAME
 IS TO BE ATTACHED TO BUCKS. SPECIFY THE
 SIZE OF BUCKS AND HOW THEY ARE TO BE
 ATTACHED TO THE STRUCTURE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-03-30 Cont ID  
Sent By csiegber Date 2004-04-02 Time 11:21 Rev Time 2.00
Received By rmcdouga Date 2004-03-30 Time 16:00 Sent To  
Notes
2004-03-30 00:00:00BULIDING PROVISO
  
 1) SUBMIT SITE SPECIFIC PRODUCT APPROVAL
 FOR BUTT GLASS WINDOW BEFORE INSTALLING.
 2) SUBMIT STATE PRODUCT APPROVAL FOR
 COLLIER GARAGE DOORS WITH APPROVED
 STATUS. SUBMIT INSTALLATION DRAWINGS FOR
 THE SMALL GARAGE DOOR BEFORE INSTALLING.
 3) SUBMIT INSTALLATION DETAIL MID-WL-MA
 0001-02 FOR THE SINGLE OUTSWING DOOR
 BEFORE INSTALLING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-03-12 Cont ID  
Sent By csiegber Date 2004-03-25 Time 17:04 Rev Time 3.00
Received By rmcdouga Date 2004-03-12 Time 09:33 Sent To  
Notes
2004-03-12 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) SUBMIT STATE PRODUCT APPROVAL FOR THE
 SINGLE OUTSWING EXTERIOR DOOR AT BATH #2
  
 4) THE STATE PRODUCT APPROVAL FOR THE
 COLLIER GARAGE DOOR IS LISTED AS VALID-
 ATED. THIS MEANS IT HAS NOT BEEN
 APPROVED. SUBMIT APPROPRIATE PRODUCT
 APPROVAL.
  
 5) SUBMIT STATE OR LOCAL PRODUCT
 APPROVAL FOR 8'X 7' GARAGE DOOR. THE
 INFO FOR THE COLLIER GARAGE DOOR THAT
 WAS SUBMITTED IS LIMITED TO A MINIMUM
 SIZE OF 10'X6'.
  
 6) THE TRUSS ANCHOR SCHEDULE ON SHEET 9
 LISTS A NU-VUE NVSTA 48 CONNECTOR. THE
 STATE PRODUCT APPROVAL SUBMITTED LISTS A
 NVRT 48 OR A NVSTA 22. PLEASE CLARIFY.
  
 7) THE TRUSS ANCHOR SCHEDULE LISTS A
 SIMPSON HUC 412 CONNECTOR WITH 1505# OF
 UPLIFT. THE STATE PRODUCT APPROVAL
 SUBMITTED IS FOR A HU 412 WITH 905# OF
 UPLIFT. PLEASE CLARIFY.
  
 8) THE HTA 16 CONNECTOR IS LISTED IN THE
 ANCHOR SCHEDULE AS A SIMPSON CONNECTOR
 AND IT SHOULD BE USP. PLEASE CORRECT.
  
 9) THE TRUSS TIE DOWN LAYOUT ON SHEET 9
 IS CONFUSING WITH UPPER AND LOWER ROOF
 AND FLOOR TRUSS CONNECTORS ALL SPECIFIED
 ON ONE DRAWING. PLEASE SEPARATE INTO
 LOWER ROOF, UPPER ROOF AND FLOOR TRUSS
 LAYOUT PLANS FOR CLARITY.
  
 10) CLARIFY THE TWO #7 ANCHORS THAT ARE
 SPECIFIED NEAR THE CENTER OF THE GIRDER
 TRUSS AT THE LOWER ROOF ON THE LEFT SIDE
 OF THE LAYOUT.
  
 11) THERE ARE INCONSISTANCES IN THE SIZE
 OF THE BUTT GLASS WINDOWS THROUGHOUT THE
 PLANS AND SITE SPECIFIC PRODUCT APPROVAL
 REAR ELEVATION HAS 40"X72", PLAN DETAIL
 HAS 44"X66" + 42-5/8"X66" AND THE SITE
 SPECIFIC PRODUCT APPROVAL HAS 44"X69" +
 39"X69". PLEASE CORRECT.
  
 12) THE LOCAL PRODUCT APPROVAL SUBMITTED
 FOR THE BUTT GLASS WINDOW IS INCOMPLETE.
 SEE RULE 9B-72. INDICATE METHOD 1 OR
 METHOD 2. INDICATE THE CATEGORY OF
 PRODUCT. THE APPLICANT SHOULD BE THE
 COMPANY ASSEMBLING THE PRODUCT. LIST AN
 APPROVED THIRD PARTY QUALITY ASSURANCE
 ENTITY. LIST ALL THE INFORMATION THAT IS
 REQUIRED FOR AN EVALUATION REPORT FROM A
 FLORIDA PROFESSIONAL ENGINEER AS LISTED
 FOR ITEM #5 IN 9B-72.040. SEE ATTACHMENT
 SPECIFY ANY LIMITATIONS (SUCH AS IMPACT
 PROTECTION REQUIRED). LIST THE
 REQUIREMENTS THE PRODUCT COMPLIES WITH
 INCLUDING CODE SECTION NUMBERS AND
 REFERENCE STANDARDS, SUCH AS FBC 1606,
 1707, 2406.2 AND TAS 202. SUBMIT TEST
 REPORTS, TECHNICAL DOCUMENTS,
 CALCULATIONS, ETC. WHICH IS THE BASIS
 FOR THE RATIONAL ANALYSIS. PROVIDE A
 DETAILED REPORT INDICATING HOW THE
 CONCLUSIONS WERE REACHED. BUTT GLAZING
 ON ARCHITECTURAL PLANS IS AT 90 DEGREE
 ANGLE. SPECIFY WHAT ANGLE OR ANGLES ARE
 ALLOWED BY PRODUCT APPROVAL.
  
 13) SUBMIT PRODUCT APPROVALS, KEY PLAN
 AND INSTALLATION SCHEDULE FOR STORM
 PANELS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-02-10 Cont ID  
Sent By csiegber Date 2004-03-01 Time 12:08 Rev Time 2.50
Received By rmcdouga Date 2004-02-10 Time 10:15 Sent To  
Notes
2004-02-10 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) FBC* 1804.2.2AREA OF QUESTIONABLE
 SOIL.SUBMIT A GEOTECHNICAL REPORT
 TO VERIFY THE SAFE BEARING CAPACITY OF
 THE SOIL.
  
 3)1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
 ON SHEET 9 THE VALUES FOR THE USP
 META 16 CONNECTOR IS TOO HIGH, IT IS
 LISTED IN USP CATALOG AS 1200#. THE
 VALUE OF THE SIMPSON META 16 IS LISTED
 IN THE HIGH WIND RESISTANT CONSTRUCTION
 CATALOG (WITHOUT STRESS INCREASE) AS
 1115#. THIS CHANGE WILL AFFECT THE ROOF
 GIRDER TRUSS REQUIRING 2356# OF UPLIFT.
 PLEASE CORRECT.
  
 4) THE DIMENSIONS LISTED ON THE BUTT
 GLASS DETAIL SHEET OF THE PLANS HAS
 DISCREPANCIES WITH THE SIZES OF THE
 GLASS PANELS AND THE SIZES SHOWN ON THE
 PLAN. INDICATE THE SPECIFIC G.E. SEALANT
 THAT IS TO BE USED (I.E. G.E. #1200).
 SUBMITTALS FOR WINDOWS ARE REQUIRED TO
 COMPLY WITH RULE 9B-72. PLEASE SUBMIT
 THE APPROPRIATE PRODUCT APPROVAL.
 PRODUCT APPROVALS FOR THE STOREFRONT
 FRAMES ARE ALSO REQUIRED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL. SEE
 ATTACHMENT AND WWW.FLORIDABUILDING.ORG.
  
 5) THE WINDLOAD PRESSURES FOR THE 2068
 DOOR TO BATH #2 ARE NOT LISTED ON THE
 ELEVATIONS. SUBMIT PRODUCT APPROVAL WITH
 INSTALLATION INSTRUCTIONS FOR THIS DOOR.
  
 6) SUBMIT PRODUCT APPROVALS FOR THE 8070
 OVERHEAD GARAGE DOOR. THE PRODUCT
 APPROVAL SUBMITTED HAS A MINIMUM SIZE
 LIMIT OF 10'W X 6'H.
  
 7) THE PRODUCT APPROVAL FOR THE COLLIER
 GARAGE DOOR DOES NOT HAVE THE CORRECT
 SUBMITTAL FORM. THE PROPER FORM HAS BEEN
 ATTACHED. SEE RULE 9B-72.
  
 8) SUBMIT STATE PRODUCT APPROVALS FOR
 TRUSS CONNECTORS THAT WILL BE USED IN
 THIS STRUCTURE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-01-14 Cont ID  
Sent By btrobaug Date 2004-01-14 Time 14:46 Rev Time 0.50
Received By btrobaug Date 2004-01-14 Time 14:36 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-04-16 Cont ID  
Sent By csiegber Date 2004-04-16 Time 08:12 Rev Time 0.00
Received By csiegber Date 2004-04-16 Time 08:12 Sent To B
Notes
2004-04-16 00:00:00TO RM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-04-06 Cont ID  
Sent By csiegber Date 2004-04-06 Time 14:17 Rev Time 0.00
Received By csiegber Date 2004-04-06 Time 14:17 Sent To B
Notes
2004-04-06 00:00:00TO RM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-04-02 Cont ID  
Sent By csiegber Date 2004-04-02 Time 11:21 Rev Time 0.00
Received By csiegber Date 2004-04-02 Time 11:21 Sent To B
Notes
2004-04-02 00:00:00TO RM DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-03-25 Cont ID  
Sent By csiegber Date 2004-03-25 Time 17:04 Rev Time 0.00
Received By csiegber Date 2004-03-25 Time 17:04 Sent To B
Notes
2004-03-25 00:00:00TO RM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-01 Cont ID  
Sent By csiegber Date 2004-03-01 Time 12:08 Rev Time 0.00
Received By csiegber Date 2004-03-01 Time 12:08 Sent To B
Notes
2004-03-01 00:00:00TO RM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-10 Cont ID  
Sent By mmclean Date 2004-01-08 Time 16:20 Rev Time 0.00
Received By rmcdouga Date 2004-01-05 Time 14:18 Sent To  
Notes
2004-01-09 00:00:00TO SFD RACK/E
2004-01-05 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-01-29 Cont ID  
Sent By btrobaug Date 2004-01-14 Time 14:46 Rev Time 0.50
Received By hmoser Date 2004-01-29 Time 18:55 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-01-24 Cont ID  
Sent By kstevens Date 2004-01-24 Time 13:48 Rev Time 0.50
Received By kstevens Date 2004-01-24 Time 13:48 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-01-08 Cont ID  
Sent By mmclean Date 2004-01-08 Time 16:20 Rev Time 0.00
Received By mmclean Date 2004-01-08 Time 16:20 Sent To I
Notes
***NONE***