| Plan Review Stops For Permit 04010028 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-04-29 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-04-29 |
Time |
10:30 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2004-04-29 |
Time |
10:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-02-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-29 |
Time |
06:58 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2004-02-20 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-02-19 |
Time |
06:27 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2004-01-27 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2004-01-27 00:00:00 | 1.PLEASE SIGN ENERGY CALCULATIONS AND | | | RESUBMIT. | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-04-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-23 |
Time |
16:07 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-04-23 |
Time |
16:07 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-03-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-04-22 |
Time |
11:14 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-03-05 |
Time |
05:25 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-02-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-26 |
Time |
17:04 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-02-19 |
Time |
06:16 |
Sent To |
B |
|
| Notes |
| 2004-02-19 00:00:00 | ************ UNSAT ******************* | | | | | | 1)NOTE: PLEASE SEE LOAD SHOWN FOR AHU | | | ON PANEL SCHEDULE, SHOWS 5KW, YET LOAD | | | CALCULATIONS DO NOT CORRELATE. | | | | | | 2)NOTE: PLEASE SHOW LOAD CALC FOR EACH | | | PANEL AND THEN SERVICE. | | | PLEASE SEE LOAD SHOWN FOR WAHT APPEARS | | | TO BE EACH PANEL @ 113 A'S, YET OCP IS | | | 100A'S? | | | | | | 3)NOTE: PLEASE SEE PANELS, SHOWN AS 42 | | | CIR, 150A PANELS ARE NOT MADE W/ 42 CIR. | | | | | | 4)NOTE: PLEASE SEE MISSING FRONT AND | | | REAR RECEPTS PER 210.52E | | | | | | 5)NOTE: PLEASE SEE MISSING RECEPT FOR | | | A/C COND UNIT. 210.63. RECEPT FOR REAR | | | OF DWELLING MAY MEET REQUIREMENT. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-01-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-09 |
Time |
10:46 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-01-12 |
Time |
13:25 |
Sent To |
M |
|
| Notes |
| 2004-01-12 00:00:00 | ************ UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE THAT NO MAINS ARE | | | SHOWN 225.31. | | | MAINS ARE TO BE GROUPED PER 230.72 | | | | | | 2)NOTE: PLEASE INCLUDE EQUIPMENT GROUND- | | | -ING FROM MAINS TO PANELS. 250.110, | | | 250.24, 250.122 | | | | | | 3)NOTE: PLEASE SEE 2002 NEC FOR RQUIRE- | | | -MENT FOR ARC FAULT PROTECTION. | | | | | | 4)NOTE: PLEASE SUBMIT AIC RATING FOR NEW | | | MAINS/ PANELS ETC. 110.9 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-04-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-04-22 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-04-22 |
Time |
11:14 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-02-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-26 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-26 |
Time |
17:04 |
Sent To |
E |
|
| Notes |
| 2004-02-26 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-02-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-09 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-09 |
Time |
10:46 |
Sent To |
E |
|
| Notes |
| 2004-02-09 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-01-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-05 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-05 |
Time |
11:16 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-04-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-29 |
Time |
06:57 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-04-29 |
Time |
06:44 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-03-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-23 |
Time |
16:13 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-03-10 |
Time |
08:29 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-01-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-02-19 |
Time |
06:16 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-01-15 |
Time |
12:04 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2004-01-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-23 |
Time |
16:07 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-01-15 |
Time |
17:53 |
Sent To |
B |
|
| Notes |
| 2004-01-15 00:00:00 | NO PLUMBING PLANS SUBMITTED - 1 AUTO- | | | MATIC CLOTHES WASHER CONNECTION PER | | | DWELLING REQD. OR 1 CONNECTION FOR UP TO | | | 20 UNITS IN COMMON AREA. |
|
|