| Plan Review Stops For Permit 04010014 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-06-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-06-21 |
Time |
08:43 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-06-21 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2004-06-21 00:00:00 | SOILS, DOOR PA |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-30 |
Time |
10:16 |
Rev Time |
2.50 |
| Received By |
shill |
Date |
2004-04-28 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2004-04-28 00:00:00 | PROVISO - SUBMIT SOILS & DOOR PRODUCT | | | APPROVAL BEFORE PERMIT IS PICKED UP |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-03-31 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-15 |
Time |
14:06 |
Rev Time |
3.00 |
| Received By |
shill |
Date |
2004-03-31 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2004-03-31 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.)ITEMS #1, 3, 4, 5, 6, 7, 8 ON THE | | | PREVIOUS LIST WERE NOT ADDRESSED (NOC, | | | HISTORIC, SF ON APP, FEES, SIGN OWNER/ | | | AGENT LINE OF ENERGY CALC, RECEIPT FOR | | | IMPACT FEES). | | | | | | 2.)THE PRODUCT APPROVAL SUBMITTED FOR | | | THE FRONT DOOR IS FOR A NON-IMPACT | | | GLAZED DOOR.THE PLAN SHOWS AN OPAQUE | | | DOOR.ONE MEANS OF ESCAPE IN THE EVENT | | | OF A HURRICANE MUST BE PROVIDED, FBC | | | 1005.4.5.ALL OF THE EXTERIOR DOORS | | | ARE GLAZED REQUIRING SHUTTERS, SO NO | | | MEANS OF ESCAPE HAS BEEN PROVIDED. | | | ADDRESS. | | | | | | 3.)THE STANLEY DOOR FLORIDA PRODUCT | | | APPROVAL NUMBER IS 1397.SUBMIT TWO | | | LEGIBLE COPIES OF THE TEST REPORT. | | | THE TEST REPORT IS AVAILABLE FOR | | | DOWNLOAD FROM WWW.FLORIDABUILDING.ORG | | | OR WWW.MIAMIDADE.GOV. | | | | | | 4.)SEE THE PREVIOUS LIST, ITEM #13. | | | IF THIS FORM, ENCLOSED, IS NOT COMPLETED | | | THEN A SEPARATE PERMIT FOR HURRICANE | | | SHUTTERS WILL BE REQUIRED. | | | | | | 5.)THE TAMKO ROOF PRODUCT APPROVALS | | | SUBMITTED ARE FOR A POURED GYPSUM DECK. | | | THE APPLICATION FOR THIS JOB IS A | | | WOOD DECK.THE GAF PRODUCT APPROVALS | | | SUBMITTED ARE CODE COMPLIANT. | | | | | | 6.)THE MODEL 180/280/381, 16' IS | | | HIGHLIGHTED ON THE GARAGE DOOR PRODUCT | | | APPROVAL, SEE SHEET 3 OF 9.THIS | | | PRODUCT HAS A DESIGN LIMITATION OF -37, | | | THE DESIGN PRESSURE FOR THE GARAGE DOOR | | | IS -39.ADDRESS. | | | | | | 7.)WINDOWS ANCHORS DETAIL, SHEET 7, | | | STILL HAVE A 2" TAPCON.WHEN USING A | | | 1X BUCK, THE TAPCON IS TO HAVE A 1 1/4" | | | EMBEDMENT THROUGH THE CONCRETE, SEE | | | THE PRODUCT APPROVAL AND FBC1707.4.4.2. | | | | | | 8.)THE PREMDOOR ENTRY DOOR PRODUCT | | | APPROVAL SUBMITTED IS FOR AN INSWING | | | DOOR, PLAN SPECIFIES OUTSWING. | | | | | | 9.)THE FOLLOWING PRODUCT APPROVALS | | | WERE NOT SUBMITTED:SLIDING GLASS DOORS | | | MULLIONS, ARCHED FIXED WINDOW, FRONT | | | DOOR. | | | | | | 10.) THE NOC IS EXPIRED (OVER 90 DAYS | | | WITHOUT COMMENCING WORK), FS713.13. | | | THE SAME DOCUMENT CAN BE REFILED WITH | | | A NEW DATE AT THE CLERK'S OFFICE. | | | | | | 11.)SEE PREVIOUS LIST, SHEET 7 | | | SPECIFIES A 2' OVERHANG.ALSO REFERS | | | TO SFC, GOVERNING CODE IS FBC2001. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-02-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-17 |
Time |
12:57 |
Rev Time |
3.00 |
| Received By |
shill |
Date |
2004-02-06 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2004-02-06 00:00:00 | *****CORRECTIONS***** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE | | | A PERMIT CAN BE ISSUED FS713.13.THE | | | NOC PROVIDED IS EXPIRED (OVER 90 DAYS | | | WITHOUT COMMENCING WORK). | | | | | | 2.)IF ALL PRODUCT APPROVALS REQUIRED | | | ARE NOT PROPERLY SUBMITTED BEFORE PERMIT | | | ISSUANCE, SEPARATE PERMITS FOR THOSE | | | ITEMS WILL BE REQUIRED. | | | | | | 3.)HAVE ANY NEW REVISED SHEETS STAMPED | | | BY HISTORIC BEFORE RESUBMITTAL. | | | | | | 4.)THE SQUARE FOOTAGE ON THE | | | APPLICATION DOES NOT MATCH THE PLAN. | | | REVISE. | | | | | | 5.)ADDITIONAL FEES DUE, $516.43, SEE | | | ATTACHED BZ235304 (VALUE ADJUSTMENT). | | | | | | 6.)HAVE AN INDIVIDUAL SIGN THE | | | OWNER/AGENT LINE OF THE ENERGY CALC, | | | FBC13-101.2. | | | | | | 7.)PROVIDE A SOILS INVESTIGATION | | | REPORT, FBC1804.2.2. | | | | | | 8.)PROVIDE THE RECEIPT FOR THE IMPACT | | | FEES. | | | | | | 9.)FLORIDA STATEWIDE OR SITE SPECIFIC | | | PRODUCT APPROVALS REQUIRED IN ADDITION | | | TO THE TEST REPORTS.PRINT THE COVER | | | SHEET FROM THE WEBSITE, CIRCLE THE | | | PRODUCT YOU ARE USING. | | | WWW.FLORIDABUILDING.ORG | | | | | | 10.) THE PRODUCT APPROVALS FOR THE | | | SINGLE HUNG WINDOW ARE NOT LEGIBLE. | | | YOU MAY BE ABLE TO DOWNLOAD THIS REPORT | | | FROM EITHER WWW.FLORIDABUILDING.ORG OR | | | WWW.MIAMIDADE.GOV (FIND A DEPT, BUILDING | | | CODE COMPLIANCE, PRODUCT CONTROL SEARCH) | | | | | | 11.) THE FOLLOWING PRODUCT APPROVALS | | | ARE REQUIRED: FRONT DOOR, MULLIONS, | | | ARCH FIXED GLASS, GARAGE DOOR, ROOF | | | TILE, SLIDING GLASS DOOR, IMPACT | | | PROTECTION, SINGLE HUNG WINDOW, ROOF. | | | | | | 12.) THE DOOR PRODUCT APPROVAL IS FOR | | | INSWING, THE DOOR IS SHOWN AS AN | | | OUTSWING. | | | | | | 13.)IMPACT PROTECTION REQUIRED | | | FBC1606.1.4.SUBMIT PRODUCT APPROVALS | | | AS WELL AS THE HURRICANE SHUTTER | | | INSTALLATION SCHEDULE ATTACHED.IF THIS | | | IS NOT SUBMITTED A SEPARATE PERMIT WILL | | | BE REQUIRED FOR SHUTTERS. | | | | | | 14.)29" CLEARANCE REQUIRED FOR THE | | | BATHROOM DOOR TO COMPLY WITH FBC11-11(1) | | | | | | 15.) SPECIFY ATTIC ACCESS TO COMPLY WITH | | | FBC2309.6. | | | | | | 16.)ROOF DOWNSPOUTS TO COMPLY WITH | | | FBC1503.4.4. | | | | | | 17.)CONFIRM THAT THE WINDOW BUCK | | | DETAIL IS CONSISTENT WITH THE PRODUCT | | | APPROVAL, WHICH IS ILLEGIBLE.IT | | | APPEARS TO REQUIRE A 1 1/2" EMBEDMENT, | | | THE DETAIL PROVIDE STATES "PER PRODUCT | | | APPROVAL" BUT ALSO GIVES A TAPCON LENGTH | | | OF 2" WHICH WOULD NOT COMPLY. | | | | | | 18.)I COULD NOT FIND THE SIMPSON | | | HUS26 IN THE HIGH WIND CATALOG WHICH | | | DOES NOT INCLUDE THE STRESS INCREASE | | | FOR STEEL.ADDRESS. | | | | | | 19.)SPECIFY TRUSS CONNECTOR (WALL | | | SECTION, SHEET 2). | | | | | | 20.)SHEET 7 SPECIFIES A 2' OVERHANG | | | AND A SQUARE FOOT AREA NOT CONSISTENT | | | WITH THE PLAN. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-06-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-24 |
Time |
14:53 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-06-24 |
Time |
14:32 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-03-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-05 |
Time |
11:35 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-03-04 |
Time |
17:38 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-01-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-04 |
Time |
15:42 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2004-01-08 |
Time |
13:14 |
Sent To |
M |
|
| Notes |
| 2004-01-08 00:00:00 | | | | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE MAKE THE FOLLOWING CHANGES FOR | | | CODE COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} THE A/C AREA SHOWN IN THE TOTAL AREA | | | BOX ON SHEETS 5/5,7/7,LOAD CALCS AND | | | PERMIT APPLICATION DO NOT | | | CORRELATE.PLEASE CHANGE TO REFLECT THE | | | CORRECT SQUARE FOOTAGES. | | | | | | 2} THE ELECTRICAL NOTES ON SHEET 5/7 | | | SHOULD REFLECT THE FOLLOWING: | | | #2 SHOULD REFERENCE THE FLORIDA | | | BUILDING CODE,NOT SFBC. | | | #4 SHOULD INDICATE THE SMOKE DETECTORS | | | BEING FED FROM AN ARC FAULT PROTECTED | | | CIRCUIT PER 210.12. | | | #7 REFERENCES AN OUT OF DATE ARTICLE, | | | PLEASE REFER TO 2002 NEC. | | | #17 SHOULD REFER TO ALL OUTLETS NOT | | | JUST RECEPTACLES,SEE 210.12 AND ALSO | | | ART. 100 FOR DEFINITION OF "OUTLET". | | | | | | 3} THE GARAGE MUST HAVE A GFI RECEPTACLE | | | PER210.8(A)(2). | | | | | | 4} PLEASE NOTE, ALL PLANS DRAWN | | | BY AN ARCHITECT/ENGINEER CONTAIN- | | | -ING A TITLE BLOCK: MUST BE SIGNED, | | | DATED AND SEALD BY THAT ARCH/ENG. | | | PER FS 481.221 471.025 | | | FAC 61G15-23.002, 61G1-16.004 | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-06-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-24 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-24 |
Time |
11:04 |
Sent To |
E |
|
| Notes |
| 2005-06-24 00:00:00 | TO "BTROBAUG" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-04-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-30 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-30 |
Time |
10:16 |
Sent To |
B |
|
| Notes |
| 2004-04-30 00:00:00 | TO SH DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-04-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-15 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-15 |
Time |
14:06 |
Sent To |
B |
|
| Notes |
| 2004-04-15 00:00:00 | TO SH DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-03-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-04 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-04 |
Time |
15:42 |
Sent To |
E |
|
| Notes |
| 2004-03-04 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-02-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-07 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-02 |
Time |
12:52 |
Sent To |
|
|
| Notes |
| 2004-01-08 00:00:00 | TO SFD RACK/E | | 2004-01-05 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-03-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-17 |
Time |
12:56 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2004-03-17 |
Time |
12:11 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-03-13 |
Time |
11:22 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-01-14 |
Time |
10:19 |
Sent To |
P |
|
| Notes |
| 2004-01-14 00:00:00 | DENIED: | | | MECHANICAL PLANS DO NOT MATCH BUILDING | | | FLOOR PLAN.THE MECHANICAL PLAN SHOWS | | | THE WALL BETWEEN THE AHU AND THE | | | RESIDENCE HAVING A 1HR RATING.PLEASE | | | REVISE MECHANICAL PLAN TO REFLECT THAT | | | OF THE BUILDING FLOOR PLAN. | | | | | | RETURN AIR DUCT IS NOT SIZED PROPERLY. | | | PLEASE SEE THE ATTACHED SCHEDULE FOR | | | REQUIRED RETURN AIR.PLEASE NOTE THE | | | MASTER BEDROOM RETURN AIR IS BASED UPON | | | THE TOTAL OF SUPPLY AIR TO THE MASTER | | | SUITE.PLAN INDICATES A 10" SUPPLY | | | WHICH WOULD REQUIRE A MINIMUM OF 13" | | | RETURN. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-03-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-03-13 |
Time |
11:22 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2004-03-13 |
Time |
11:22 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-01-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-05 |
Time |
11:35 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-01-15 |
Time |
09:53 |
Sent To |
B |
|
| Notes |
| 2004-01-15 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLA. ADMIN. CODE | | | FLA. STATUTES. | | | | | | 1) SHT 6/7 SANITARY RISER DIAGRAM DOES | | | NOT MEET CODE REQUIREMENTS. | | | A) MASTER BATH - W/C SHALL BE VENTED BY | | | WET VENT AND BE TIED INTO THE BATHROOM | | | GROUP. PUMPING ACTION FROM WASH MACHINE | | | WILL EFFECT WATER CLOSET TRAP SEAL. | | | B) MASTER BATH - NO DRY HORIZONTAL DRY | | | VENTS ALLOWED. SECTION 905.3 | | | C) TUB NOT VENTED IN SECOND BATH. SEC- | | | TION 901.2.1 | | | D) SEE RED LINE CORRECTIONS ON PLUMBING | | | LAYOUT AND RISER DIAGRAM. | | | 2) PLANS SUBMITTED BY AN ENGINEER SHALL | | | BE SIGNED, SEALED AND DATED BY THE | | | ENGINEER. FAC 61G15-23.002(1) & FS 471 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-01-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-07 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-01-07 |
Time |
14:36 |
Sent To |
I |
|
| Notes |
|
|