Plan Review Details - Permit 04010014
Plan Review Stops For Permit 04010014
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-06-21 Cont ID  
Sent By shill Date 2004-06-21 Time 08:43 Rev Time 0.50
Received By shill Date 2004-06-21 Time 08:43 Sent To  
Notes
2004-06-21 00:00:00SOILS, DOOR PA

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-04-28 Cont ID  
Sent By csiegber Date 2004-04-30 Time 10:16 Rev Time 2.50
Received By shill Date 2004-04-28 Time 14:52 Sent To  
Notes
2004-04-28 00:00:00PROVISO - SUBMIT SOILS & DOOR PRODUCT
 APPROVAL BEFORE PERMIT IS PICKED UP

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-03-31 Cont ID  
Sent By csiegber Date 2004-04-15 Time 14:06 Rev Time 3.00
Received By shill Date 2004-03-31 Time 12:44 Sent To  
Notes
2004-03-31 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
  
 1.)ITEMS #1, 3, 4, 5, 6, 7, 8 ON THE
 PREVIOUS LIST WERE NOT ADDRESSED (NOC,
 HISTORIC, SF ON APP, FEES, SIGN OWNER/
 AGENT LINE OF ENERGY CALC, RECEIPT FOR
 IMPACT FEES).
  
 2.)THE PRODUCT APPROVAL SUBMITTED FOR
 THE FRONT DOOR IS FOR A NON-IMPACT
 GLAZED DOOR.THE PLAN SHOWS AN OPAQUE
 DOOR.ONE MEANS OF ESCAPE IN THE EVENT
 OF A HURRICANE MUST BE PROVIDED, FBC
 1005.4.5.ALL OF THE EXTERIOR DOORS
 ARE GLAZED REQUIRING SHUTTERS, SO NO
 MEANS OF ESCAPE HAS BEEN PROVIDED.
 ADDRESS.
  
 3.)THE STANLEY DOOR FLORIDA PRODUCT
 APPROVAL NUMBER IS 1397.SUBMIT TWO
 LEGIBLE COPIES OF THE TEST REPORT.
 THE TEST REPORT IS AVAILABLE FOR
 DOWNLOAD FROM WWW.FLORIDABUILDING.ORG
 OR WWW.MIAMIDADE.GOV.
  
 4.)SEE THE PREVIOUS LIST, ITEM #13.
 IF THIS FORM, ENCLOSED, IS NOT COMPLETED
 THEN A SEPARATE PERMIT FOR HURRICANE
 SHUTTERS WILL BE REQUIRED.
  
 5.)THE TAMKO ROOF PRODUCT APPROVALS
 SUBMITTED ARE FOR A POURED GYPSUM DECK.
 THE APPLICATION FOR THIS JOB IS A
 WOOD DECK.THE GAF PRODUCT APPROVALS
 SUBMITTED ARE CODE COMPLIANT.
  
 6.)THE MODEL 180/280/381, 16' IS
 HIGHLIGHTED ON THE GARAGE DOOR PRODUCT
 APPROVAL, SEE SHEET 3 OF 9.THIS
 PRODUCT HAS A DESIGN LIMITATION OF -37,
 THE DESIGN PRESSURE FOR THE GARAGE DOOR
 IS -39.ADDRESS.
  
 7.)WINDOWS ANCHORS DETAIL, SHEET 7,
 STILL HAVE A 2" TAPCON.WHEN USING A
 1X BUCK, THE TAPCON IS TO HAVE A 1 1/4"
 EMBEDMENT THROUGH THE CONCRETE, SEE
 THE PRODUCT APPROVAL AND FBC1707.4.4.2.
  
 8.)THE PREMDOOR ENTRY DOOR PRODUCT
 APPROVAL SUBMITTED IS FOR AN INSWING
 DOOR, PLAN SPECIFIES OUTSWING.
  
 9.)THE FOLLOWING PRODUCT APPROVALS
 WERE NOT SUBMITTED:SLIDING GLASS DOORS
 MULLIONS, ARCHED FIXED WINDOW, FRONT
 DOOR.
  
 10.) THE NOC IS EXPIRED (OVER 90 DAYS
 WITHOUT COMMENCING WORK), FS713.13.
 THE SAME DOCUMENT CAN BE REFILED WITH
 A NEW DATE AT THE CLERK'S OFFICE.
  
 11.)SEE PREVIOUS LIST, SHEET 7
 SPECIFIES A 2' OVERHANG.ALSO REFERS
 TO SFC, GOVERNING CODE IS FBC2001.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-02-06 Cont ID  
Sent By pkrauss Date 2004-03-17 Time 12:57 Rev Time 3.00
Received By shill Date 2004-02-06 Time 13:05 Sent To  
Notes
2004-02-06 00:00:00*****CORRECTIONS*****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE
 A PERMIT CAN BE ISSUED FS713.13.THE
 NOC PROVIDED IS EXPIRED (OVER 90 DAYS
 WITHOUT COMMENCING WORK).
  
 2.)IF ALL PRODUCT APPROVALS REQUIRED
 ARE NOT PROPERLY SUBMITTED BEFORE PERMIT
 ISSUANCE, SEPARATE PERMITS FOR THOSE
 ITEMS WILL BE REQUIRED.
  
 3.)HAVE ANY NEW REVISED SHEETS STAMPED
 BY HISTORIC BEFORE RESUBMITTAL.
  
 4.)THE SQUARE FOOTAGE ON THE
 APPLICATION DOES NOT MATCH THE PLAN.
 REVISE.
  
 5.)ADDITIONAL FEES DUE, $516.43, SEE
 ATTACHED BZ235304 (VALUE ADJUSTMENT).
  
 6.)HAVE AN INDIVIDUAL SIGN THE
 OWNER/AGENT LINE OF THE ENERGY CALC,
 FBC13-101.2.
  
 7.)PROVIDE A SOILS INVESTIGATION
 REPORT, FBC1804.2.2.
  
 8.)PROVIDE THE RECEIPT FOR THE IMPACT
 FEES.
  
 9.)FLORIDA STATEWIDE OR SITE SPECIFIC
 PRODUCT APPROVALS REQUIRED IN ADDITION
 TO THE TEST REPORTS.PRINT THE COVER
 SHEET FROM THE WEBSITE, CIRCLE THE
 PRODUCT YOU ARE USING.
 WWW.FLORIDABUILDING.ORG
  
 10.) THE PRODUCT APPROVALS FOR THE
 SINGLE HUNG WINDOW ARE NOT LEGIBLE.
 YOU MAY BE ABLE TO DOWNLOAD THIS REPORT
 FROM EITHER WWW.FLORIDABUILDING.ORG OR
 WWW.MIAMIDADE.GOV (FIND A DEPT, BUILDING
 CODE COMPLIANCE, PRODUCT CONTROL SEARCH)
  
 11.) THE FOLLOWING PRODUCT APPROVALS
 ARE REQUIRED: FRONT DOOR, MULLIONS,
 ARCH FIXED GLASS, GARAGE DOOR, ROOF
 TILE, SLIDING GLASS DOOR, IMPACT
 PROTECTION, SINGLE HUNG WINDOW, ROOF.
  
 12.) THE DOOR PRODUCT APPROVAL IS FOR
 INSWING, THE DOOR IS SHOWN AS AN
 OUTSWING.
  
 13.)IMPACT PROTECTION REQUIRED
 FBC1606.1.4.SUBMIT PRODUCT APPROVALS
 AS WELL AS THE HURRICANE SHUTTER
 INSTALLATION SCHEDULE ATTACHED.IF THIS
 IS NOT SUBMITTED A SEPARATE PERMIT WILL
 BE REQUIRED FOR SHUTTERS.
  
 14.)29" CLEARANCE REQUIRED FOR THE
 BATHROOM DOOR TO COMPLY WITH FBC11-11(1)
  
 15.) SPECIFY ATTIC ACCESS TO COMPLY WITH
 FBC2309.6.
  
 16.)ROOF DOWNSPOUTS TO COMPLY WITH
 FBC1503.4.4.
  
 17.)CONFIRM THAT THE WINDOW BUCK
 DETAIL IS CONSISTENT WITH THE PRODUCT
 APPROVAL, WHICH IS ILLEGIBLE.IT
 APPEARS TO REQUIRE A 1 1/2" EMBEDMENT,
 THE DETAIL PROVIDE STATES "PER PRODUCT
 APPROVAL" BUT ALSO GIVES A TAPCON LENGTH
 OF 2" WHICH WOULD NOT COMPLY.
  
 18.)I COULD NOT FIND THE SIMPSON
 HUS26 IN THE HIGH WIND CATALOG WHICH
 DOES NOT INCLUDE THE STRESS INCREASE
 FOR STEEL.ADDRESS.
  
 19.)SPECIFY TRUSS CONNECTOR (WALL
 SECTION, SHEET 2).
  
 20.)SHEET 7 SPECIFIES A 2' OVERHANG
 AND A SQUARE FOOT AREA NOT CONSISTENT
 WITH THE PLAN.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-06-24 Cont ID  
Sent By btrobaug Date 2005-06-24 Time 14:53 Rev Time 0.50
Received By btrobaug Date 2005-06-24 Time 14:32 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-03-05 Cont ID  
Sent By btrobaug Date 2004-03-05 Time 11:35 Rev Time 0.50
Received By btrobaug Date 2004-03-04 Time 17:38 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-01-08 Cont ID  
Sent By csiegber Date 2004-03-04 Time 15:42 Rev Time 1.00
Received By btrobaug Date 2004-01-08 Time 13:14 Sent To M
Notes
2004-01-08 00:00:00 
 UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CHANGES FOR
 CODE COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} THE A/C AREA SHOWN IN THE TOTAL AREA
 BOX ON SHEETS 5/5,7/7,LOAD CALCS AND
 PERMIT APPLICATION DO NOT
 CORRELATE.PLEASE CHANGE TO REFLECT THE
 CORRECT SQUARE FOOTAGES.
  
 2} THE ELECTRICAL NOTES ON SHEET 5/7
 SHOULD REFLECT THE FOLLOWING:
 #2 SHOULD REFERENCE THE FLORIDA
 BUILDING CODE,NOT SFBC.
 #4 SHOULD INDICATE THE SMOKE DETECTORS
 BEING FED FROM AN ARC FAULT PROTECTED
 CIRCUIT PER 210.12.
 #7 REFERENCES AN OUT OF DATE ARTICLE,
 PLEASE REFER TO 2002 NEC.
 #17 SHOULD REFER TO ALL OUTLETS NOT
 JUST RECEPTACLES,SEE 210.12 AND ALSO
 ART. 100 FOR DEFINITION OF "OUTLET".
  
 3} THE GARAGE MUST HAVE A GFI RECEPTACLE
 PER210.8(A)(2).
  
 4} PLEASE NOTE, ALL PLANS DRAWN
 BY AN ARCHITECT/ENGINEER CONTAIN-
 -ING A TITLE BLOCK: MUST BE SIGNED,
 DATED AND SEALD BY THAT ARCH/ENG.
 PER FS 481.221 471.025
 FAC 61G15-23.002, 61G1-16.004
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-06-24 Cont ID  
Sent By adarroug Date 2005-06-24 Time 11:04 Rev Time 0.00
Received By adarroug Date 2005-06-24 Time 11:04 Sent To E
Notes
2005-06-24 00:00:00TO "BTROBAUG" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-04-30 Cont ID  
Sent By csiegber Date 2004-04-30 Time 10:16 Rev Time 0.00
Received By csiegber Date 2004-04-30 Time 10:16 Sent To B
Notes
2004-04-30 00:00:00TO SH DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-04-15 Cont ID  
Sent By csiegber Date 2004-04-15 Time 14:06 Rev Time 0.00
Received By csiegber Date 2004-04-15 Time 14:06 Sent To B
Notes
2004-04-15 00:00:00TO SH DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-04 Cont ID  
Sent By csiegber Date 2004-03-04 Time 15:42 Rev Time 0.00
Received By csiegber Date 2004-03-04 Time 15:42 Sent To E
Notes
2004-03-04 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-06 Cont ID  
Sent By mmclean Date 2004-01-07 Time 14:36 Rev Time 0.00
Received By csiegber Date 2004-01-02 Time 12:52 Sent To  
Notes
2004-01-08 00:00:00TO SFD RACK/E
2004-01-05 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-03-17 Cont ID  
Sent By pkrauss Date 2004-03-17 Time 12:56 Rev Time 0.33
Received By pkrauss Date 2004-03-17 Time 12:11 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-01-14 Cont ID  
Sent By jleech Date 2004-03-13 Time 11:22 Rev Time 0.35
Received By pkrauss Date 2004-01-14 Time 10:19 Sent To P
Notes
2004-01-14 00:00:00DENIED:
 MECHANICAL PLANS DO NOT MATCH BUILDING
 FLOOR PLAN.THE MECHANICAL PLAN SHOWS
 THE WALL BETWEEN THE AHU AND THE
 RESIDENCE HAVING A 1HR RATING.PLEASE
 REVISE MECHANICAL PLAN TO REFLECT THAT
 OF THE BUILDING FLOOR PLAN.
  
 RETURN AIR DUCT IS NOT SIZED PROPERLY.
 PLEASE SEE THE ATTACHED SCHEDULE FOR
 REQUIRED RETURN AIR.PLEASE NOTE THE
 MASTER BEDROOM RETURN AIR IS BASED UPON
 THE TOTAL OF SUPPLY AIR TO THE MASTER
 SUITE.PLAN INDICATES A 10" SUPPLY
 WHICH WOULD REQUIRE A MINIMUM OF 13"
 RETURN.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-03-13 Cont ID  
Sent By jleech Date 2004-03-13 Time 11:22 Rev Time 0.50
Received By jleech Date 2004-03-13 Time 11:22 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-01-15 Cont ID  
Sent By btrobaug Date 2004-03-05 Time 11:35 Rev Time 0.50
Received By kstevens Date 2004-01-15 Time 09:53 Sent To B
Notes
2004-01-15 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FLA. ADMIN. CODE
 FLA. STATUTES.
  
 1) SHT 6/7 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS.
 A) MASTER BATH - W/C SHALL BE VENTED BY
 WET VENT AND BE TIED INTO THE BATHROOM
 GROUP. PUMPING ACTION FROM WASH MACHINE
 WILL EFFECT WATER CLOSET TRAP SEAL.
 B) MASTER BATH - NO DRY HORIZONTAL DRY
 VENTS ALLOWED. SECTION 905.3
 C) TUB NOT VENTED IN SECOND BATH. SEC-
 TION 901.2.1
 D) SEE RED LINE CORRECTIONS ON PLUMBING
 LAYOUT AND RISER DIAGRAM.
 2) PLANS SUBMITTED BY AN ENGINEER SHALL
 BE SIGNED, SEALED AND DATED BY THE
 ENGINEER. FAC 61G15-23.002(1) & FS 471
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-01-07 Cont ID  
Sent By mmclean Date 2004-01-07 Time 14:36 Rev Time 0.00
Received By mmclean Date 2004-01-07 Time 14:36 Sent To I
Notes
***NONE***