| Plan Review Stops For Permit 04010006 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-04-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-04-08 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-04-08 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2005-04-08 00:00:00 | REVISED PAGES A6-A9 ARE OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-03-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-21 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-21 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2005-03-21 00:00:00 | OWENS CORNING SHINGLES APPROVED FOR USE | | | ABOVE 33 FEET BY NEIL MELICK, B.O. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-15 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-15 |
Time |
07:10 |
Sent To |
|
|
| Notes |
| 2005-03-21 00:00:00 | CONTRACTOR TO BRING IN NEW ENERGY CALCS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-02-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-02-11 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
mamini |
Date |
2005-01-28 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2004-02-11 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04010006 (8 UNIT) | | | ADD: 1100 N CONGRESS | | | CONT: WCI N CONGRESS | | | CONTACT PERSON: DOUG BERK | | | TEL: (561)262-3684 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | ARCH: WCI ARCHITECTURE & LAND PLANNING | | | CONTACT: PETER SYNOYANNIS | | | (954) 575-4200 | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | THE COMMENTS FROM 04010005 (4) UNIT | | | BUILDING ARE APPLICIABLE ACCEPT FOR THE | | | FAIR HOUSING. | | | | | | 1)903.8.2 FLOR ST STATUTE 553.895(2) | | | ALL RESIDENTIAL BUILD. 3 OR MORE STORIES | | | TALL WHETHER DESIGNATED AS TOWNHOUSE, | | | CONDOMINIUMS, "APARTMENT HOUSES, | | | TENEMENTS, GARDEN APARTMENTS OR BY ANY | | | OTHER NAME SHALL BE SUPPLIED BY FIRE | | | SPRINKLERS MEETING NFPA 101. | | | PROVIDE 3 COPIES OF FIRE SPRINKLER | | | PLANS TO BE INCLUDED WITH THE BUILDING | | | PLANS. | | | | | | 2) PROVIDE THE MEAN ROOF HEIGHT OF THE | | | BUILDING FROM "GRADE" TO INCLUDE 1/2 THE | | | HEIGHT OF THE TRUSSES OFF OF THE HEIGH- | | | EST BEAM. APPROX- 38'-4 1/2". | | | | | | 3) SHEET S-4 TRUSS PLAN DOES NOT INDI- | | | CATE THE TRUSS OR GIRDER LOADS, VERTICAL | | | HORIZONTAL AND GRAVITY LOADS TO BE | | | RESISTED. THE TRUSS ANCHOR LEGOND | | | "E-H" DOES NOT GIVE ANY VALUE FOR THE | | | FASTENER!!!!!!!!!!!!!!!!!!!!!!!!!!!! | | | | | | 4) SHEET S-3 INDICATES PRECAST LINTELS | | | ARETO BE USED, PROVIDE LINTEL SCHEDULE | | | AND ALLOWABLE LOADS VS SPANS. | | | | | | 5) SHEET S-5 WALL AND ROOF PRESSURE | | | ZONES INDICATE LOW PRESSURES! SINCE THE | | | MEAN ROOF HEIGHT IS > 35' A HEIGHT | | | ADJUSTMENT FACTOR IS REQUIRED OF 1.09 | | | SEE TABLE 1606.2D. | | | | | | 6) SHEET S-5 ROOF NAILING SCHEDULE | | | ZONE# 3 NAILS ARE TO BE "RING SHANK". | | | WEST PALM BEACH AMENDMENT TABLE 2306.1. | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | JIM WITMER | | | BUILDING PLAN REVIEW | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-02-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-09 |
Time |
19:30 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-02-09 |
Time |
19:30 |
Sent To |
|
|
| Notes |
| 2005-02-09 00:00:00 | ELEC OK, STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-01-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-12 |
Time |
14:07 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-01-12 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2004-01-12 00:00:00 | ************* UNSAT ***************** | | | | | | 1)NOTE: PLANS REFERENCE THE 1999 NEC, | | | PLEASE SEE THAT WE ARE UNDER THE 2002 | | | NEC. | | | | | | 2)NOTE: PLEASE NOTE, ALL PLANS DRAWN | | | BY AN ARCHITECT/ENGINEER CONTAIN- | | | -ING A TITLE BLOCK: MUST BE SIGNED, | | | DATED AND SEALD BY THAT ARCH/ENG. | | | PER FS 481.221 471.025 | | | FAC 61G15-23.002, 61G1-16.004 | | | | | | 3 )NOTE: PLEASE SEE MISSING REQ'D EGRESS | | | LIGHTING AND/OR CLARIFY EGRESS LIGHTING | | | PER 210.70 AND LS-101 5-8 | | | | | | 4) NOTE: PLEASE LIST ALL THE REQ'D | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE. PER 210.52D, 210.11C3 | | | | | | 5) NOTE: PLEASE SHOW GROUNDING ELETRODE | | | SYSTEM PER 250.50. FOOTER STEEL/COLD | | | WATER/ ETC. SIZE ALL PER 250.66 | | | | | | 6)NOTE: PLEASE INCLUDE ALL LICENSE #'S | | | AS REQ'D UNDER FAC 61G15-23.002/FS 471 | | | PLEASE ALSO SEE FS 471.023 | | | | | | 7)NOTE: PLEASE SEE RISER, SHOWS EMT | | | BEING INSTALLED FOR DIRECT BURIAL. | | | PLEASE SEE THAT THIS IS NOT PERMITTED. | | | SEE 348-5 LOCAL AMENDMENTS. | | | PLEASE ALSO SEE NEC 358 | | | | | | 8)NOTE: PLEASE SEE FHAR CFR 100.205 | | | FOR ALL HEIGHT REQ'MENTS. PLEASE SHOW | | | ON PLANS. | | | | | | 9)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | SHOWN FOR UNIT MAINS, BUT NOT FOR 1200A | | | MAIN. | | | | | | 10) NOTE: PLEASE SEE MISSING RECEPTS FOR | | | FRONT AND/OR REAR OF DWELLING. | | | 210.52EREAR? | | | | | | 11)NOTE:PLEASE SEE MISSING RECEPT REQ'D | | | FOR A/C EQUIPMENT. 210.63 | | | | | | PLEASE SEE COMMENTS FROM OTHER REVIEWERS | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2005-01-28 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-01-28 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
mamini |
Date |
2005-01-28 |
Time |
13:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2004-01-08 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-01-08 |
Time |
14:48 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-01-08 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2004-01-08 00:00:00 | PASSED: | | | 1. SEE PERMIT # 03101412 FOR UNDERGROUND | | | UTILITIES AND SITE WORK (PALN REVIEW). | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-03-02 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-03-02 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-03-02 |
Time |
14:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-01-09 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-09 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-09 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2004-01-09 00:00:00 | 1) NO FIRE SPRINKLER PLANS PROVIDED | | | WITH DRAWINGS. | | | | | | 2) BUILDING ADDRESSES REQUIRED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-04-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-06 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-06 |
Time |
11:44 |
Sent To |
B |
|
| Notes |
| 2005-04-06 00:00:00 | TO "RMCDOUGAL" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-02-01 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-28 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2005-03-02 00:00:00 | 3/2/05 MOVED TO BD#54-ADARROUGH | | 2005-01-28 00:00:00 | TO "COMM BD#37/RESUB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-01-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-13 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-02 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2004-01-02 00:00:00 | TO COMM BD#34 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2005-02-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-02-07 |
Time |
06:52 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-02-07 |
Time |
06:52 |
Sent To |
|
|
| Notes |
| 2005-02-07 00:00:00 | SUBMITTAL - ENERGY & MANUAL J | | | CALCULATIONS ALONG WITH A SIGNED,SEALED | | | LETTER FROM THE ENGINEER INDICATING THE | | | O.A. DUCT WILL BE CONSTRUCTED OF METAL | | | PER THE MECHANICAL CODE. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2005-02-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-02-01 |
Time |
07:16 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2005-02-01 |
Time |
06:51 |
Sent To |
|
|
| Notes |
| 2005-02-01 00:00:00 | DENIED: | | | COMMENTS FROM REVIEW DATED 3-25-04 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-03-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-25 |
Time |
11:14 |
Rev Time |
1.40 |
| Received By |
pkrauss |
Date |
2004-03-25 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2004-03-25 00:00:00 | DENIED: | | | 1.PLEASE NOTE, DETAIL OF UL DESIGN | | | L528 IN THE UL DIRECTORY DOES NOT | | | INDICATE ANY PENETRATIONS THROUGH THIS | | | ASSEMBLY.PLEASE PROVIDE UL LISTING | | | FOR THE PENETRATIONS THROUGH THE RATED | | | ASSEMBLY. | | | | | | 2.PLEASE CLARIFY RATING ON PLAN SHEET | | | A-10 DETAIL #4, THE 1HR RATING IS AT THE | | | PARTITION WALL TO THE UNDERSIDE OF THE | | | CEILING CORRECT?IF THIS IS CORRECT, | | | THE FIRE DAMPER INDICATED ON PLAN SHEET | | | M-1 IS NOT REQUIRED BECAUSE THE WALL | | | DOES NOT CONTINUE ABOVE THE CEILING. | | | | | | 3.CLARIFY O.A. DUCT, IS APPEARS TO BE | | | ABOVE THE CEILING AND DOES NOT PENETRATE | | | THE BOTTOM MEMBRANE OF THE ASSEMBLY OR | | | AT THE POINT OF ENTRY, FIRE DAMPER NOT | | | REQUIRED. | | | | | | 4.PLANS SHALL BE SIGNED BY THE | | | ENGINEER NOT STAMPED WITH THEIR S | | | SIGNATURE PER FS 471.025. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-22 |
Time |
11:11 |
Rev Time |
1.20 |
| Received By |
pkrauss |
Date |
2004-01-22 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2004-01-22 00:00:00 | DENIED: | | | 1.PLANS ARE NOT SIGNED, SEALED, AND | | | DATED BY THE ENGINEER AS REQUIRED BY FS | | | 471.025 & THE FAC 61G15-23.002. | | | | | | 2.PLAN SHEET A-9 & A-13.1 DETAIL 1 & | | | 2, INDICATE 1 HOUR FIRE RATED | | | FLOOR/CEILING & CEILING/ROOF | | | ASSEMBLIES.PENETRATIONS THROUGH RATED | | | ASSEMBLIES SHALL COMPY WITH 2001 FBC(M) | | | 607.2. | | | | | | 3.DUCTS PENETRATING MORE THAN ONE | | | STORY SHALL BE PROTECTED BY A SHAFT | | | ENCLOSURE PER 2001 FBC(M) 607.4. | | | PLEASE PROVIDE DETAIL OF SHAFT | | | ENCLOSURE. | | | | | | 4.PLEASE INDICATE PROTECTION OF | | | EXHAUST DUCT WORK PENETRATING 1 HOUR | | | CEILING/ROOF ASSEMBLY. (PLAN SHEET M-2) | | | | | | 5.PLAN SHEET RETURN AIR JUMPERS ARE | | | NOT SIZED PROPERLY.PLEASE NOTE, | | | MASTER BEDROOM IS TO INCLUDE ALL AIR TO | | | THE MASTER SUITE PER 2001 FBC(M) 601.4 | | | EXCEPTION 1 AND 4 (SEE THE ATTACHED | | | SCHEDULE FOR PROPER SIZING). | | | | | | 6.PLEASE PROVIDE OUTSIDE AIR | | | CALCULATIONS PER 2001 FBC(M) 403.3. | | | | | | 7.INDICATE OUTSIDE AIR INTAKE, DUCT | | | SIZE, MATERIAL, AND LAYOUT. | | | | | | 8.ENERGY AND MANUAL J CALCULATIONS | | | REQUIRED FOR APPROVAL PER 2001 FBC | | | CHAPTER 13. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-03-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-03 |
Time |
06:56 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2005-03-03 |
Time |
06:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-22 |
Time |
13:46 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-01-22 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2004-01-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMIN. CODE | | | FLORIDA STATUTES | | | | | | 1) A SANITARY AND A WATER RISER DIAGRAM | | | ARE REQUIRED PER SECTION 104.2.1. | | | 2) PROFESSIONAL ENGINEER SHALL SIGN HIS | | | NAME AND AFFIX HIS SEAL TO ALL PLANS, | | | SPECIFICATIONS, REPORTS AND FINAL BID | | | DOCUMENTS PROVIDED TO THE OWNER OR THE | | | OWNER'S REPRESENTATIVE, OR OTHER DOCU- | | | MENTS PREPARED OR ISSUED BY SAID REGIS- | | | TRANT AND BEING FILED FOR PUBLIC RECORD. | | | THE DATE THAT THE SIGNATURE AND SEAL IS | | | AFFIXED AS PROVIDED HEREIN SHALL BE EN- | | | TERED ON SAID PLANS, SPECIFICATIONS, RE- | | | PORTS, OR OTHER DOCUMENTS IMMEDIATELY | | | UNDER THE SIGNATURE OF THE PROFESSIONAL | | | ENGINEER, FAC 61G15-23.002(1) | | | *** | | | EACH SHEET OF PLANS AND PRINTS WHICH | | | MUST BE SEALED UNDER THE PROVISIONS OF | | | CHAPTER 471 SHALL BE SEALED, SIGNED AND | | | DATED BY THE PROFESSIONAL ENGINEER IN | | | RESPONSIBLE CHARGE. FAC 61G15-23.002(2) | | | *** | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | | SHEET. IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | | EERS, ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME AND LICENSE NUMBER, AS WELL | | | AS, THE NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. A TITLE BLOCK | | | WILL SATISFY THIS REQUIREMENT. FAC | | | 61G15-23.002(2) | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2005-04-07 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2005-04-07 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2005-04-07 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2005-02-14 |
Time |
14:36 |
Rev Time |
0.20 |
| Received By |
eschneid |
Date |
2005-02-14 |
Time |
14:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-12-12 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-13 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2003-12-12 |
Time |
11:43 |
Sent To |
I |
|
| Notes |
| 2004-02-13 00:00:00 | 2ND REQUEST - PER ERIC SCHNEIDER SENIOR | | | PLANNER 1- NO LANDSCAPE PLANS WERE | | | INCLUDED, NEED TO PROVIDE ONE FOR PERMIT | | | 2 - SITE PLAN SHEET 1 OR 5 IS NOT THE | | | ONE THE CITY COMMISSION APPROVED.NEED | | | TO SUBMIT THE 9/26/03 REVISED ONE ITEMS | | | AFFECTED ARE PARKING DATA IS MISSING. | | | 3 - ENTRY SIGN LOCATION SHOWN ON SHEETS | | | 1,3 & 5 DO NOT MEET SETBACKS. RESIDENTAL | | | DEVELOPMENT ENTRY SIGNS ARE REQUIRED TO | | | HAVE A 20' SETBACK FROM THE ROW. |
|
|